Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-35589375

RESUMO

INTRODUCTION: Selecting the ideal contact to apply subthalamic nucleus deep brain stimulation (STN-DBS) in Parkinson's disease is time-consuming and reliant on clinical expertise. The aim of this cohort study was to assess whether neuronal signals (beta oscillations and evoked resonant neural activity (ERNA)), and the anatomical location of electrodes, can predict the contacts selected by long-term, expert-clinician programming of STN-DBS. METHODS: We evaluated 92 hemispheres of 47 patients with Parkinson's disease receiving chronic monopolar and bipolar STN-DBS. At each contact, beta oscillations and ERNA were recorded intraoperatively, and anatomical locations were assessed. How these factors, alone and in combination, predicted the contacts clinically selected for chronic deep brain stimulation at 6 months postoperatively was evaluated using a simple-ranking method and machine learning algorithms. RESULTS: The probability that each factor individually predicted the clinician-chosen contact was as follows: ERNA 80%, anatomy 67%, beta oscillations 50%. ERNA performed significantly better than anatomy and beta oscillations. Combining neuronal signal and anatomical data did not improve predictive performance. CONCLUSION: This work supports the development of probability-based algorithms using neuronal signals and anatomical data to assist programming of deep brain stimulation.

2.
Neurobiol Dis ; 130: 104522, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31276793

RESUMO

Deep brain stimulation is an established therapy for Parkinson's disease; however, its effectiveness is hindered by limited understanding of therapeutic mechanisms and the lack of a robust feedback signal for tailoring stimulation. We recently reported that subthalamic nucleus deep brain stimulation evokes a neural response resembling a decaying high-frequency (200-500 Hz) oscillation that typically has a duration of at least 10 ms and is localizable to the dorsal sub-region. As the morphology of this response suggests a propensity for the underlying neural circuitry to oscillate at a particular frequency, we have named it evoked resonant neural activity. Here, we determine whether this evoked activity is modulated by therapeutic stimulation - a critical attribute of a feedback signal. Furthermore, we investigated whether any related changes occurred in spontaneous local field potentials. Evoked and spontaneous neural activity was intraoperatively recorded from 19 subthalamic nuclei in patients with Parkinson's disease. Recordings were obtained before therapeutic stimulation and during 130 Hz stimulation at increasing amplitudes (0.67-3.38 mA), 'washout' of therapeutic effects, and non-therapeutic 20 Hz stimulation. Therapeutic efficacy was assessed using clinical bradykinesia and rigidity scores. The frequency and amplitude of evoked resonant neural activity varied with the level of 130 Hz stimulation (p < .001). This modulation coincided with improvement in bradykinesia and rigidity (p < .001), and correlated with spontaneous beta band suppression (p < .001). Evoked neural activity occupied a similar frequency band to spontaneous high-frequency oscillations (200-400 Hz), both of which decreased to around twice the 130 Hz stimulation rate. Non-therapeutic stimulation at 20 Hz evoked, but did not modulate, resonant activity. These results indicate that therapeutic deep brain stimulation alters the frequency of evoked and spontaneous oscillations recorded in the subthalamic nucleus that are likely generated by loops within the cortico-basal ganglia-thalamo-cortical network. Evoked resonant neural activity therefore has potential as a tool for providing insight into brain network function and has key attributes of a dynamic feedback signal for optimizing therapy.


Assuntos
Encéfalo/fisiopatologia , Estimulação Encefálica Profunda , Potenciais Evocados/fisiologia , Neurônios/fisiologia , Doença de Parkinson/fisiopatologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
3.
Ann Neurol ; 83(5): 1027-1031, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29727475

RESUMO

Deep brain stimulation (DBS) is a rapidly expanding treatment for neurological and psychiatric conditions; however, a target-specific biomarker is required to optimize therapy. Here, we show that DBS evokes a large-amplitude resonant neural response focally in the subthalamic nucleus. This response is greatest in the dorsal region (the clinically optimal stimulation target for Parkinson disease), coincides with improved clinical performance, is chronically recordable, and is present under general anesthesia. These features make it a readily utilizable electrophysiological signal that could potentially be used for guiding electrode implantation surgery and tailoring DBS therapy to improve patient outcomes. Ann Neurol 2018;83:1027-1031.


Assuntos
Estimulação Encefálica Profunda , Doença de Parkinson/terapia , Núcleo Subtalâmico/cirurgia , Resultado do Tratamento , Estimulação Encefálica Profunda/métodos , Eletrodos Implantados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/fisiopatologia , Núcleo Subtalâmico/fisiopatologia
4.
Brain Commun ; 4(1): fcac003, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35169708

RESUMO

Selecting the ideal contact to apply subthalamic nucleus deep brain stimulation in Parkinson's disease can be an arduous process, with outcomes highly dependent on clinician expertise. This study aims to assess whether neuronal signals recorded intraoperatively in awake patients, and the anatomical location of contacts, can assist programming. In a cohort of 14 patients with Parkinson's disease, implanted with subthalamic nucleus deep brain stimulation, the four contacts on each lead in the 28 hemispheres were ranked according to proximity to a nominated ideal anatomical location and power of the following neuronal signals: evoked resonant neural activity, beta oscillations and high-frequency oscillations. We assessed how these rankings predicted, on each lead: (i) the motor benefit from deep brain stimulation applied through each contact and (ii) the 'ideal' contact to apply deep brain stimulation. The ranking of contacts according to each factor predicted motor benefit from subthalamic nucleus deep brain stimulation, as follows: evoked resonant neural activity; r 2 = 0.50, Akaike information criterion 1039.9, beta; r 2 = 0.50, Akaike information criterion 1041.6, high-frequency oscillations; r 2 = 0.44, Akaike information criterion 1057.2 and anatomy; r 2 = 0.49, Akaike information criterion 1048.0. Combining evoked resonant neural activity, beta and high-frequency oscillations ranking data yielded the strongest predictive model (r 2 = 0.61, Akaike information criterion 1021.5). The 'ideal' contact (yielding maximal benefit) was ranked first according to each factor in the following proportion of hemispheres; evoked resonant neural activity 18/28, beta 17/28, anatomy 16/28, high-frequency oscillations 7/28. Across hemispheres, the maximal available deep brain stimulation benefit did not differ from that yielded by contacts chosen by clinicians for chronic therapy or contacts ranked first according to evoked resonant neural activity. Evoked resonant neural activity, beta oscillations and anatomy similarly predicted how motor benefit from subthalamic nucleus deep brain stimulation varied across contacts on each lead. This could assist programming by providing a probability ranking of contacts akin to a 'monopolar survey'. However, these factors identified the 'ideal' contact in only a proportion of hemispheres. More advanced signal processing and anatomical techniques may be needed for the full automation of contact selection.

5.
J Neurosurg ; : 1-10, 2021 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-34891136

RESUMO

OBJECTIVE: Deep brain stimulation (DBS) surgery is commonly performed with the patient awake to facilitate assessments of electrode positioning. However, awake neurosurgery can be a barrier to patients receiving DBS. Electrode implantation can be performed with the patient under general anesthesia (GA) using intraoperative imaging, although such techniques are not widely available. Electrophysiological features can also aid in the identification of target neural regions and provide functional evidence of electrode placement. Here we assess the presence and positional variation under GA of spontaneous beta and high-frequency oscillation (HFO) activity, and evoked resonant neural activity (ERNA), a novel evoked response localized to the subthalamic nucleus. METHODS: ERNA, beta, and HFO were intraoperatively recorded from DBS leads comprising four individual electrodes immediately after bilateral awake implantation into the subthalamic nucleus of 21 patients with Parkinson's disease (42 hemispheres) and after subsequent GA induction deep enough to perform pulse generator implantation. The main anesthetic agent was either propofol (10 patients) or sevoflurane (11 patients). RESULTS: GA reduced the amplitude of ERNA, beta, and HFO activity (p < 0.001); however, ERNA amplitudes remained large in comparison to spontaneous local field potentials. Notably, a moderately strong correlation between awake ERNA amplitude and electrode distance to an "ideal" therapeutic target within dorsal STN was preserved under GA (awake: ρ = -0.73, adjusted p value [padj] < 0.001; GA: ρ = -0.69, padj < 0.001). In contrast, correlations were diminished under GA for beta (awake: ρ = -0.45, padj < 0.001; GA: ρ = -0.13, padj = 0.12) and HFO (awake: ρ = -0.69, padj < 0.001; GA: ρ = -0.33, padj < 0.001). The largest ERNA occurred at the same electrode (awake vs GA) for 35/42 hemispheres (83.3%) and corresponded closely to the electrode selected by the clinician for chronic therapy at 12 months (awake ERNA 77.5%, GA ERNA 82.5%). The largest beta amplitude occurred at the same electrode (awake vs GA) for only 17/42 (40.5%) hemispheres and 21/42 (50%) for HFO. The electrode measuring the largest awake beta and HFO amplitudes corresponded to the electrode selected by the clinician for chronic therapy at 12 months in 60% and 70% of hemispheres, respectively. However, this correspondence diminished substantially under GA (beta 20%, HFO 35%). CONCLUSIONS: ERNA is a robust electrophysiological signal localized to the dorsal subthalamic nucleus subregion that is largely preserved under GA, indicating it could feasibly guide electrode implantation, either alone or in complementary use with existing methods.

6.
Anesthesiology ; 113(2): 292-304, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20613470

RESUMO

BACKGROUND: The purpose of this study was to evaluate a new, physiologically inspired method for the analysis of the electroencephalogram during propofol-remifentanil anesthesia. Based on fixed-order autoregressive moving-average modeling, this method was hypothesized to be capable of dissociating the effects that hypnotic and analgesic agents have on brain electrical activity. METHODS: Raw electroencephalographic waves from a previously published study were reanalyzed. In this study, 45 American Society of Anesthesiologists status I patients were randomly allocated to one of three groups according to a specific target effect-site remifentanil concentration (0, 2, and 4 ng/ml). All patients received stepwise-increased targeted effect-site concentrations of propofol (CePROP). At each step change in target CePROP, the Observer's Assessment of Alertness/Sedation score was evaluated. Raw electroencephalograph was continuously acquired from frontal electrodes. Electroencephalography traces were analyzed using a fixed-order autoregressive moving average model to give derived measures of Cortical State and Cortical Input. Response surfaces were visualized and modeled using Hierarchical Linear Modeling. RESULTS: Cortical State (a measure of cortical responsiveness) and Cortical Input (a measure of the magnitude of cortical input) were shown to respond differently to CePROP and effect-site remifentanil concentration. Cortical Input decreased significantly with increasing effect-site remifentanil concentration, whereas Cortical State remained unchanged with increasing effect-site remifentanil concentration but decreased with increasing CePROP. CONCLUSION: Because Cortical State responds principally to variations in CePROP, it is a potential measure of hypnosis, whereas the dependence of Cortical Input on effect-site remifentanil concentration suggests that it may be useful as a measure of analgesic efficacy and the nociceptive-antinociceptive balance.


Assuntos
Anestesia Intravenosa , Eletroencefalografia/efeitos dos fármacos , Lobo Frontal/efeitos dos fármacos , Lobo Frontal/fisiologia , Piperidinas/farmacologia , Propofol/farmacologia , Adulto , Anestesia Intravenosa/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Remifentanil
7.
Front Hum Neurosci ; 14: 54, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32292333

RESUMO

The Seventh Annual Deep Brain Stimulation (DBS) Think Tank held on September 8th of 2019 addressed the most current: (1) use and utility of complex neurophysiological signals for development of adaptive neurostimulation to improve clinical outcomes; (2) Advancements in recent neuromodulation techniques to treat neuropsychiatric disorders; (3) New developments in optogenetics and DBS; (4) The use of augmented Virtual reality (VR) and neuromodulation; (5) commercially available technologies; and (6) ethical issues arising in and from research and use of DBS. These advances serve as both "markers of progress" and challenges and opportunities for ongoing address, engagement, and deliberation as we move to improve the functional capabilities and translational value of DBS. It is in this light that these proceedings are presented to inform the field and initiate ongoing discourse. As consistent with the intent, and spirit of this, and prior DBS Think Tanks, the overarching goal is to continue to develop multidisciplinary collaborations to rapidly advance the field and ultimately improve patient outcomes.

8.
J Neurosci Methods ; 317: 113-120, 2019 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-30776378

RESUMO

BACKGROUND: Parkinsonian rigidity is identified on clinical examination as resistance to passive movement. Measurement of rigidity commonly relies on ordinal rating scales (MDS-UPDRS), however instrumented objective measures may provide greater mechanistic insight. NEW METHOD: We present a palm-worn instrument to objectively quantify rigidity on a continuous scale. The device employs a miniature motor to flex the third digit of the hand about the metacarpophalangeal joint whilst transducers record flexion/extension forces. We aim to determine congruence with the MDS-UPDRS, investigate sensitivity to the impact of deep brain stimulation (DBS) and contralateral movement, and make comparisons with healthy individuals. Eight participants with Parkinson's disease underwent evaluation during conditions: on and off DBS, and with and without contralateral limb movement to activate rigidity. During each DBS condition, wash-in/out effects were tracked using both our instrument and two blinded clinical raters. Sixteen healthy volunteers (age-matched/young) served as controls. RESULTS: Rigidity measured using our instrument had moderate agreement with the MDS-UPDRS and showed differences between therapeutic state, activation conditions, and disease/healthy cohorts. Rigidity gradually worsened over a one-hour period after DBS cessation, but improved more rapidly with DBS resumption. COMPARISON WITH EXISTING METHODS: Previous attempts to quantify rigidity include manual approaches where a clinician is required to manipulate limbs while sensors passively gather information, or large automated instruments to move the wrist or elbow. CONCLUSION: Given its ability to track changes in rigidity due to therapeutic intervention, our technique could have applications where continuous measurement is required or where a suitably qualified rater is absent.


Assuntos
Monitorização Fisiológica/métodos , Rigidez Muscular/diagnóstico , Doença de Parkinson/diagnóstico , Dispositivos Eletrônicos Vestíveis , Estimulação Encefálica Profunda , Estudos de Viabilidade , Feminino , Mãos , Humanos , Masculino , Pessoa de Meia-Idade , Rigidez Muscular/complicações , Doença de Parkinson/complicações , Doença de Parkinson/terapia
9.
Physiol Meas ; 40(1): 014004, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30650391

RESUMO

OBJECTIVE: Quantification of bradykinesia (slowness of movement) is crucial for the treatment and monitoring of Parkinson's disease. Subjective observational techniques are the de-facto 'gold standard', but such clinical rating scales suffer from poor sensitivity and inter-rater variability. Although various technologies have been developed for assessing bradykinesia in recent years, most still require considerable expertise and effort to operate. Here we present a novel method to utilize an inexpensive off-the-shelf hand-tracker (Leap Motion) to quantify bradykinesia. APPROACH: Eight participants with Parkinson's disease receiving benefit from deep brain stimulation were recruited for the study. Participants were assessed 'on' and 'off' stimulation, with the 'on' condition repeated to evaluate reliability. Participants performed wrist pronation/supination, hand open/close, and finger-tapping tasks during each condition. Tasks were simultaneously captured by our software and rated by three clinicians. A linear regression model was developed to predict clinical scores and its performance was assessed with leave-one-subject-out cross validation. MAIN RESULTS: Aggregate bradykinesia scores predicted by our method were in strong agreement (R = 0.86) with clinical scores. The model was able to differentiate therapeutic states and comparison between the test-retest conditions yielded no significant difference (p  = 0.50). SIGNIFICANCE: These findings demonstrate that our method can objectively quantify bradykinesia in agreement with clinical observation and provide reliable measurements over time. The hardware is readily accessible, requiring only a modest computer and our software to perform assessments, thus making it suitable for both clinic- and home-based symptom tracking.


Assuntos
Custos e Análise de Custo , Hipocinesia/complicações , Hipocinesia/fisiopatologia , Monitorização Fisiológica/economia , Monitorização Fisiológica/instrumentação , Movimento , Doença de Parkinson/complicações , Adulto , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Processamento de Sinais Assistido por Computador
10.
Comput Biol Med ; 38(10): 1121-30, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18834978

RESUMO

A number of commonly used anesthetics, including nitrous oxide (N2O), are poorly detected by current electroencephalography (EEG)-based measures of anesthetic depth such as the bispectral index. Based on a previously elaborated theory of electrocortical rhythmogenesis we developed a physiologically inspired method of EEG analysis that was hypothesized to be more sensitive in detecting and characterizing N2O effect than the bispectral index, through its combined EEG estimates of cortical input and cortical state. By evaluating sevoflurane-induced loss of consciousness in the presence of low brain concentrations of N2O in 38 elective surgical patients, N2O was associated with a statistically significant reduction in the input the frontal cortex received from other cortical and subcortical areas. In contrast the bispectral index responded only to low, but not to high, concentrations of N2O.


Assuntos
Encéfalo/efeitos dos fármacos , Modelos Biológicos , Óxido Nitroso/farmacologia , Pressão Sanguínea , Encéfalo/fisiologia , Eletroencefalografia , Frequência Cardíaca , Humanos , Oxigênio/sangue
11.
Invest Ophthalmol Vis Sci ; 58(10): 3962-3974, 2017 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-28793152

RESUMO

Purpose: Retinal prostheses provide vision to blind patients by eliciting phosphenes through electrical stimulation. This study explored whether character identification and image localization could be achieved through direct multiple-electrode stimulation with a suprachoroidal retinal prosthesis. Methods: Two of three retinitis pigmentosa patients implanted with a suprachoroidal electrode array were tested on three psychophysical tasks. Electrode patterns were stimulated to elicit perception of simple characters, following which percept localization was tested using either static or dynamic images. Eye tracking was used to assess the association between accuracy and eye movements. Results: In the character identification task, accuracy ranged from 2.7% to 93.3%, depending on the patient and character. In the static image localization task, accuracy decreased from near perfect to <20% with decreasing contrast (patient 1). Patient 2 scored up to 70% at 100% contrast. In the dynamic image localization task, patient 1 recognized the trajectory of the image up to speeds of 64 deg/s, whereas patient 2 scored just above chance. The degree of eye movement in both patients was related to accuracy and, to some extent, stimulus direction. Conclusions: The ability to identify characters and localize percepts demonstrates the capacity of the suprachoroidal device to provide meaningful information to blind patients. The variation in scores across all tasks highlights the importance of using spatial cues from phosphenes, which becomes more difficult at low contrast. The use of spatial information from multiple electrodes and eye-movement compensation is expected to improve performance outcomes during real-world prosthesis use in a camera-based system. (ClinicalTrials.gov number, NCT01603576.).


Assuntos
Estimulação Elétrica/métodos , Eletrodos Implantados , Reconhecimento Visual de Modelos/fisiologia , Retina/fisiopatologia , Retinose Pigmentar/cirurgia , Próteses Visuais , Adulto , Feminino , Humanos , Masculino , Psicofísica , Retinose Pigmentar/fisiopatologia , Movimentos Sacádicos/fisiologia , Adulto Jovem
12.
Invest Ophthalmol Vis Sci ; 58(7): 3231-3239, 2017 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-28660276

RESUMO

Purpose: With a retinal prosthesis connected to a head-mounted camera, subjects can perform low vision tasks using a combination of electrode discrimination and head-directed localization. The objective of the present study was to investigate the contribution of retinotopic electrode discrimination (perception corresponding to the arrangement of the implanted electrodes with respect to their position beneath the retina) to visual performance for three recipients of a 24-channel suprachoroidal retinal implant. Proficiency in retinotopic discrimination may allow good performance with smaller head movements, and identification of this ability would be useful for targeted rehabilitation. Methods: Three participants with retinitis pigmentosa performed localization and grating acuity assessments using a suprachoroidal retinal prosthesis. We compared retinotopic and nonretinotopic electrode mapping and hypothesized that participants with measurable acuity in a normal retinotopic condition would be negatively impacted by the nonretinotopic condition. We also expected that participants without measurable acuity would preferentially use head movement over retinotopic information. Results: Only one participant was able to complete the grating acuity task. In the localization task, this participant exhibited significantly greater head movements and significantly lower localization scores when using the nonretinotopic electrode mapping. There was no significant difference in localization performance or head movement for the remaining two subjects when comparing retinotopic to nonretinotopic electrode mapping. Conclusions: Successful discrimination of retinotopic information is possible with a suprachoroidal retinal prosthesis. Head movement behavior during a localization task can be modified using a nonretinotopic mapping. Behavioral comparisons using retinotopic and nonretinotopic electrode mapping may be able to highlight deficiencies in retinotopic discrimination, with a view to address these deficiencies in a rehabilitation environment. (ClinicalTrials.gov number, NCT01603576).


Assuntos
Cegueira/reabilitação , Eletrodos Implantados , Retinose Pigmentar/complicações , Próteses Visuais , Cegueira/fisiopatologia , Potenciais Evocados Visuais/fisiologia , Feminino , Movimentos da Cabeça , Humanos , Masculino , Pessoa de Meia-Idade , Retinose Pigmentar/fisiopatologia , Acuidade Visual/fisiologia
13.
Invest Ophthalmol Vis Sci ; 57(11): 4948-4961, 2016 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-27654422

RESUMO

Purpose: Phosphenes are the fundamental building blocks for presenting meaningful visual information to the visually impaired using a bionic eye device. The aim of this study was to characterize the size, shape, and location of phosphenes elicited using a suprachoroidal retinal prosthesis. Methods: Three patients with profound vision loss due to retinitis pigmentosa were implanted with a suprachoroidal electrode array, which was used to deliver charge-balanced biphasic constant-current pulses at various rates, amplitudes, and durations to produce phosphenes. Tasks assessing phosphene appearance, location, overlap, and the patients' ability to recognize phosphenes were performed using a custom psychophysics setup. Results: Phosphenes were reliably elicited in all three patients, with marked differences in the reported appearances between patients and between electrodes. Phosphene shapes ranged from simple blobs to complex forms with multiple components in both space and time. Phosphene locations within the visual field generally corresponded to the retinotopic position of the stimulating electrodes. Overlap between phosphenes elicited from adjacent electrodes was observed with one patient, which reduced with increasing electrode separation. In a randomized recognition task, two patients correctly identified the electrode being stimulated for 57.2% and 23% of trials, respectively. Conclusions: Phosphenes of varying complexity were successfully elicited in all three patients, indicating that the suprachoroidal space is an efficacious site for electrically stimulating the retina. The recognition scores obtained with two patients suggest that a suprachoroidal implant can elicit phosphenes containing unique information. This information may be useful when combining phosphenes into more complex and meaningful images that provide functional vision.

14.
J Neural Eng ; 13(3): 036013, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27108845

RESUMO

OBJECTIVE: One strategy to improve the effectiveness of prosthetic vision devices is to process incoming images to ensure that key information can be perceived by the user. This paper presents the first comprehensive results of vision function testing for a suprachoroidal retinal prosthetic device utilizing of 20 stimulating electrodes. Further, we investigate whether using image filtering can improve results on a light localization task for implanted participants compared to minimal vision processing. No controlled implanted participant studies have yet investigated whether vision processing methods that are not task-specific can lead to improved results. APPROACH: Three participants with profound vision loss from retinitis pigmentosa were implanted with a suprachoroidal retinal prosthesis. All three completed multiple trials of a light localization test, and one participant completed multiple trials of acuity tests. The visual representations used were: Lanczos2 (a high quality Nyquist bandlimited downsampling filter); minimal vision processing (MVP); wide view regional averaging filtering (WV); scrambled; and, system off. MAIN RESULTS: Using Lanczos2, all three participants successfully completed a light localization task and obtained a significantly higher percentage of correct responses than using MVP ([Formula: see text]) or with system off ([Formula: see text]). Further, in a preliminary result using Lanczos2, one participant successfully completed grating acuity and Landolt C tasks, and showed significantly better performance ([Formula: see text]) compared to WV, scrambled and system off on the grating acuity task. SIGNIFICANCE: Participants successfully completed vision tasks using a 20 electrode suprachoroidal retinal prosthesis. Vision processing with a Nyquist bandlimited image filter has shown an advantage for a light localization task. This result suggests that this and targeted, more advanced vision processing schemes may become important components of retinal prostheses to enhance performance. ClinicalTrials.gov Identifier: NCT01503576.


Assuntos
Corioide/fisiologia , Visão Ocular/fisiologia , Próteses Visuais , Cegueira/psicologia , Cegueira/reabilitação , Eletrodos Implantados , Feminino , Humanos , Luz , Masculino , Pessoa de Meia-Idade , Desempenho Psicomotor , Retinose Pigmentar/psicologia , Retinose Pigmentar/reabilitação , Resultado do Tratamento , Transtornos da Visão/psicologia , Transtornos da Visão/reabilitação , Acuidade Visual , Percepção Visual
16.
IEEE J Transl Eng Health Med ; 3: 3800111, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-27170910

RESUMO

To evaluate the efficacy of a suprachoroidal retinal prosthesis, a highly configurable external neurostimulator is required. In order to meet functional and safety specifications, it was necessary to develop a custom device. A system is presented which can deliver charge-balanced, constant-current biphasic pulses, with widely adjustable parameters, to arbitrary configurations of output electrodes. This system is shown to be effective in eliciting visual percepts in a patient with approximately 20 years of light perception vision only due to retinitis pigmentosa, using an electrode array implanted in the suprachoroidal space of the eye. The flexibility of the system also makes it suitable for use in a number of other emerging clinical neurostimulation applications, including epileptic seizure suppression and closed-loop deep brain stimulation. Clinical trial registration number NCT01603576 (www.clinicaltrials.gov).

17.
Invest Ophthalmol Vis Sci ; 55(10): 6467-81, 2014 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-25205858

RESUMO

PURPOSE: The suprachoroidal location for a retinal prosthesis provides advantages over other locations in terms of a simplified surgical procedure and a potentially more stable electrode-neural interface. The aim of this study was to assess the factors affecting perceptual thresholds, and to optimize stimulus parameters to achieve the lowest thresholds in patients implanted with a suprachoroidal retinal prosthesis. METHODS: Three patients with profound vision loss from retinitis pigmentosa were implanted with a suprachoroidal array. Perceptual thresholds measured on individual electrodes were analyzed as a function of stimulus (return configuration, pulse polarity, pulse width, interphase gap, and rate), electrode (area and number of ganged electrodes), and clinical (retinal thickness and electrode-retina distance) parameters. RESULTS: A total of 92.8% of 904 measurements made up to 680 days post implantation yielded thresholds (range, 44-436 nanocoulombs [nC]) below the safe charge limit. Thresholds were found to vary between individuals and to depend significantly on electrode-retina distance, negligibly on retinal thickness, and not on electrode area or the number of ganged electrodes. Lowest thresholds were achieved when using a monopolar return, anodic-first polarity, short pulse widths (100 µs) combined with long interphase gaps (500 µs), and high stimulation rates (≥400 pulses per second [pps]). CONCLUSIONS: With suprachoroidal stimulation, anodic-first pulses with a monopolar return are most efficacious. To enable high rates, an appropriate combination of pulse width and interphase gap must be chosen to ensure low thresholds and electrode voltages. Electrode-retina distance needs to be monitored carefully owing to its influence on thresholds. These results inform implantable stimulator specifications for a suprachoroidal retinal prosthesis. (ClinicalTrials.gov number, NCT01603576.).


Assuntos
Potenciais Evocados Visuais/fisiologia , Retina/cirurgia , Retinose Pigmentar/cirurgia , Córtex Visual/fisiopatologia , Percepção Visual/fisiologia , Próteses Visuais , Adulto , Estimulação Elétrica , Feminino , Humanos , Masculino , Microeletrodos , Pessoa de Meia-Idade , Desenho de Prótese , Retina/fisiopatologia , Retinose Pigmentar/fisiopatologia , Resultado do Tratamento , Adulto Jovem
18.
PLoS One ; 9(12): e115239, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25521292

RESUMO

UNLABELLED: Retinal visual prostheses ("bionic eyes") have the potential to restore vision to blind or profoundly vision-impaired patients. The medical bionic technology used to design, manufacture and implant such prostheses is still in its relative infancy, with various technologies and surgical approaches being evaluated. We hypothesised that a suprachoroidal implant location (between the sclera and choroid of the eye) would provide significant surgical and safety benefits for patients, allowing them to maintain preoperative residual vision as well as gaining prosthetic vision input from the device. This report details the first-in-human Phase 1 trial to investigate the use of retinal implants in the suprachoroidal space in three human subjects with end-stage retinitis pigmentosa. The success of the suprachoroidal surgical approach and its associated safety benefits, coupled with twelve-month post-operative efficacy data, holds promise for the field of vision restoration. TRIAL REGISTRATION: Clinicaltrials.gov NCT01603576.


Assuntos
Procedimentos Cirúrgicos Oftalmológicos/instrumentação , Retinose Pigmentar/cirurgia , Próteses Visuais/efeitos adversos , Corioide/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Oftalmológicos/métodos , Complicações Pós-Operatórias , Esclera/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA