Ann Acad Med Singap ; 16(4): 583-5, 1987 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-3328553

RESUMO

One hundred and fifty blood bank donors were sero-surveyed for legionella antibodies by indirect immunofluorescence test using a polyvalent antigen group (1 to 4). 20% of the group surveyed had an antibody titre greater than or equal to 16 to the organism. This paper also reports a study on 166 hospitalised acute pneumonia patients. The sera from these patients were screened for L. pneumophila antibodies; 5 of the patients had significant antibody titre greater than or equal to 256 which is diagnostic of legionellosis.


Assuntos
Anticorpos Antibacterianos/análise , Doadores de Sangue , Legionella/imunologia , Doença dos Legionários/epidemiologia , Imunofluorescência , Humanos , Doença dos Legionários/diagnóstico , Doença dos Legionários/imunologia , Singapura