RESUMO
PURPOSE: Due to host-mediated adverse reaction to metallic debris, there is an increasing need for noninvasive assessment of the soft tissue surrounding large joint arthroplasties. Quantitative T2 mapping can be beneficial for tissue characterization and early diagnosis of tissue pathology but current T2 mapping techniques lack the capability to image near metal hardware. A novel multi-spectral T2 mapping technique is proposed to address this unmet need. METHODS: A T2 mapping pulse sequence based on routinely implemented 3D multi-spectral imaging (3D-MSI) pulse sequences is described and demonstrated. The 3D-MSI pulse sequence is altered to acquire images at 2 echo times. Phantom and knee experiments were performed to assess the quantitative capabilities of the sequence in comparison to a commercially available T2 mapping sequence. The technique was demonstrated for use within a clinical protocol in 2 total hip arthroplasty (THA) cases to assess T2 variations within the periprosthetic joint space. RESULTS: The proposed multi-spectral T2 mapping technique agreed, within experimental errors, with T2 values derived from a commercially available clinical standard of care T2 mapping sequence. The same level of agreement was observed in quantitative phantoms and in vivo experiments. In THA cases, the method was able to assess variations of T2 within the synovial envelope immediately adjacent to implant interfaces. CONCLUSIONS: The proposed 3D-MSI T2 mapping sequence was successfully demonstrated in assessing tissue T2 variations near metal implants.
Assuntos
Imageamento Tridimensional/métodos , Prótese do Joelho , Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Metais , Humanos , Imagens de FantasmasRESUMO
PURPOSE: The presence of metallic debris near total hip arthroplasty can have a significant impact on longitudinal patient management. Methods for magnetic resonance imaging-based quantification of metallic debris near painful total hip replacements are described and applied to cohorts of symptomatic and control subject cases. METHODS: A combination of metal artifact reduction, off-resonance mapping, off-resonance background removal, and spatial clustering methods are utilized to quantify off-resonance signatures in cases of suspected metallosis. These methods are applied to a cohort of symptomatic hip arthroplasties composed of cobalt-chromium alloys. Magnetostatic simulations and theoretical principles are used to illuminate the potential sources of the measured off-resonance effects. Reported metrics from histological tissue assays extracted during surgical revision procedures are also correlated with the proposed magnetic resonance imaging-based quantification results. RESULTS: The presented methods identified quantifiable metallosis signatures in more than 70% of the symptomatic and none of the control cases. Preliminary correlations of the MR data with direct histological evaluation of retrieved tissue samples indicate that the observed off-resonance effect may be related to tissue necrosis. CONCLUSIONS: Magnetostatic simulations, theoretical principles, and preliminary histological trends suggest that disassociated cobalt is the source of the observed off-resonance signature. Magn Reson Med 79:1628-1637, 2018. © 2017 International Society for Magnetic Resonance in Medicine.