Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 18(5): 315-324, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28719019

RESUMO

As technology continues to develop, external beam radiation therapy is being employed, with increased conformity, to treat smaller targets. As this occurs, the dosimetry methods and tools employed to quantify these fields for treatment also have to evolve to provide increased spatial resolution. The team at the University of Wollongong has developed a pixelated silicon detector prototype known as the dose magnifying glass (DMG) for real-time small-field metrology. This device has been tested in photon fields and IMRT. The purpose of this work was to conduct the initial performance tests with proton radiation, using beam energies and modulations typically associated with proton radiosurgery. Depth dose and lateral beam profiles were measured and compared with those collected using a PTW parallel-plate ionization chamber, a PTW proton-specific dosimetry diode, EBT3 Gafchromic film, and Monte Carlo simulations. Measurements of the depth dose profile yielded good agreement when compared with Monte Carlo, diode and ionization chamber. Bragg peak location was measured accurately by the DMG by scanning along the depth dose profile, and the relative response of the DMG at the center of modulation was within 2.5% of that for the PTW dosimetry diode for all energy and modulation combinations tested. Real-time beam profile measurements of a 5 mm 127 MeV proton beam also yielded FWHM and FW90 within ±1 channel (0.1 mm) of the Monte Carlo and EBT3 film data across all depths tested. The DMG tested here proved to be a useful device at measuring depth dose profiles in proton therapy with a stable response across the entire proton spread-out Bragg peak. In addition, the linear array of small sensitive volumes allowed for accurate point and high spatial resolution one-dimensional profile measurements of small radiation fields in real time to be completed with minimal impact from partial volume averaging.


Assuntos
Terapia com Prótons/instrumentação , Radiocirurgia/instrumentação , Desenho de Equipamento , Método de Monte Carlo , Radiometria/instrumentação , Radiocirurgia/métodos , Silício
2.
J Appl Clin Med Phys ; 16(6): 51-64, 2015 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-26699554

RESUMO

The small fields and sharp gradients typically encountered in proton radiosurgery require high spatial resolution dosimetric measurements, especially below 1-2 cm diameters. Radiochromic film provides high resolution, but requires postprocessing and special handling. Promising alternatives are diode detectors with small sensitive volumes (SV) that are capable of high resolution and real-time dose acquisition. In this study we evaluated the PTW PR60020 proton dosimetry diode using radiation fields and beam energies relevant to radiosurgery applications. Energies of 127 and 157 MeV (9.7 to 15 cm range) and initial diameters of 8, 10, 12, and 20mm were delivered using single-stage scattering and four modulations (0, 15, 30, and 60mm) to a water tank in our treatment room. Depth dose and beam profile data were compared with PTW Markus N23343 ionization chamber, EBT2 Gafchromic film, and Monte Carlo simulations. Transverse dose profiles were measured using the diode in "edge-on" orientation or EBT2 film. Diode response was linear with respect to dose, uniform with dose rate, and showed an orientation-dependent (i.e., beam parallel to, or perpendicular to, detector axis) response of less than 1%. Diodevs. Markus depth-dose profiles, as well as Markus relative dose ratio vs. simulated dose-weighted average lineal energy plots, suggest that any LET-dependent diode response is negligible from particle entrance up to the very distal portion of the SOBP for the energies tested. Finally, while not possible with the ionization chamber due to partial volume effects, accurate diode depth-dose measurements of 8, 10, and 12 mm diameter beams were obtained compared to Monte Carlo simulations. Because of the small SV that allows measurements without partial volume effects and the capability of submillimeter resolution (in edge-on orientation) that is crucial for small fields and high-dose gradients (e.g., penumbra, distal edge), as well as negligible LET dependence over nearly the full the SOBP, the PTW proton diode proved to be a useful high-resolution, real-time metrology device for small proton field radiation measurements such as would be encountered in radiosurgery applications.


Assuntos
Terapia com Prótons/métodos , Radiometria/instrumentação , Radiocirurgia/métodos , Simulação por Computador , Humanos , Transferência Linear de Energia , Modelos Lineares , Método de Monte Carlo , Terapia com Prótons/instrumentação , Radiocirurgia/instrumentação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Água , Filme para Raios X
3.
Radiat Res ; 172(1): 30-41, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19580505

RESUMO

This study compared the effects of photons (gamma rays), protons and simulated solar particle event protons (sSPE) on the expression of profibrotic factors/extracellular matrix (ECM) regulators in lung tissue after whole-body irradiation. TGF-beta1, matrix metalloproteinase 2 and 9 (MMP-2, -9), and tissue inhibitor of metalloproteinase 1 and 2 (TIMP-1, -2) were assessed on days 4 and 21 in lungs from C57BL/6 mice exposed to 0 Gy or 2 Gy photons (0.7 Gy/min), protons (0.9 Gy/min) and sSPE (0.056 Gy/h). RT-PCR, histological and immunohistochemical techniques were used. The most striking changes included (1) up-regulation of TGF-beta1 by photons and sSPE, but not protons, at both times, (2) MMP-2 enhancement by photons and sSPEs, (3) TIMP-1 up-regulation by photons at both times, and (4) more collagen accumulation after exposure to either photons or sSPE than after exposure to protons. The findings demonstrate that expression of important ECM regulators was highly dependent upon the radiation regimen as well as the time after exposure. The data further suggest that irradiation during an SPE may increase an astronaut's risk for pulmonary complications. The greater perturbations after photon exposure compared to proton exposure have clinical implications and warrant further investigation.


Assuntos
Radiação Cósmica , Proteínas da Matriz Extracelular/efeitos da radiação , Pulmão/metabolismo , Pulmão/efeitos da radiação , Fótons , Prótons , Animais , Colágeno/metabolismo , Proteínas da Matriz Extracelular/metabolismo , Feminino , Raios gama , Antígenos Comuns de Leucócito/metabolismo , Leucócitos/metabolismo , Pulmão/patologia , Metaloproteinase 2 da Matriz/metabolismo , Metaloproteinase 9 da Matriz/metabolismo , Camundongos , Camundongos Endogâmicos C57BL , RNA Mensageiro/metabolismo , Inibidor Tecidual de Metaloproteinase-1/metabolismo , Inibidor Tecidual de Metaloproteinase-2/metabolismo , Fator de Crescimento Transformador beta1/metabolismo
4.
J Appl Physiol (1985) ; 106(6): 1935-42, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19342437

RESUMO

Spaceflight conditions have a significant impact on a number of physiological functions due to psychological stress, radiation, and reduced gravity. To explore the effect of the flight environment on immunity, C57BL/6NTac mice were flown on a 13-day space shuttle mission (STS-118). In response to flight, animals had a reduction in liver, spleen, and thymus masses compared with ground (GRD) controls (P < 0.005). Splenic lymphocyte, monocyte/macrophage, and granulocyte counts were significantly reduced in the flight (FLT) mice (P < 0.05). Although spontaneous blastogenesis of splenocytes in FLT mice was increased, response to lipopolysaccharide (LPS), a B-cell mitogen derived from Escherichia coli, was decreased compared with GRD mice (P < 0.05). Secretion of IL-6 and IL-10, but not TNF-alpha, by LPS-stimulated splenocytes was increased in FLT mice (P < 0.05). Finally, many of the genes responsible for scavenging reactive oxygen species were upregulated after flight. These data indicate that exposure to the spaceflight environment can increase anti-inflammatory mechanisms and change the ex vivo response to LPS, a bacterial product associated with septic shock and a prominent Th1 response.


Assuntos
Expressão Gênica , Imunidade/fisiologia , Mioglobina/genética , Estresse Oxidativo/genética , Voo Espacial , Animais , Citocinas/metabolismo , Feminino , Contagem de Leucócitos , Lipopolissacarídeos/farmacologia , Fígado/patologia , Ativação Linfocitária/imunologia , Contagem de Linfócitos , Camundongos , Análise de Sequência com Séries de Oligonucleotídeos , Tamanho do Órgão , RNA Mensageiro/metabolismo , Baço/efeitos dos fármacos , Baço/metabolismo , Baço/patologia , Timo/patologia , Regulação para Cima
5.
J Appl Physiol (1985) ; 106(1): 194-202, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18988762

RESUMO

The immune system is highly sensitive to stressors present during spaceflight. The major emphasis of this study was on the T lymphocytes in C57BL/6NTac mice after return from a 13-day space shuttle mission (STS-118). Spleens and thymuses from flight animals (FLT) and ground controls similarly housed in animal enclosure modules (AEM) were evaluated within 3-6 h after landing. Phytohemagglutinin-induced splenocyte DNA synthesis was significantly reduced in FLT mice when based on both counts per minute and stimulation indexes (P < 0.05). Flow cytometry showed that CD3(+) T and CD19(+) B cell counts were low in spleens from the FLT group, whereas the number of NK1.1(+) natural killer (NK) cells was increased (P < 0.01 for all three populations vs. AEM). The numerical changes resulted in a low percentage of T cells and high percentage of NK cells in FLT animals (P < 0.05). After activation of spleen cells with anti-CD3 monoclonal antibody, interleukin-2 (IL-2) was decreased, but IL-10, interferon-gamma, and macrophage inflammatory protein-1alpha were increased in FLT mice (P < 0.05). Analysis of cancer-related genes in the thymus showed that the expression of 30 of 84 genes was significantly affected by flight (P < 0.05). Genes that differed from AEM controls by at least 1.5-fold were Birc5, Figf, Grb2, and Tert (upregulated) and Fos, Ifnb1, Itgb3, Mmp9, Myc, Pdgfb, S100a4, Thbs, and Tnf (downregulated). Collectively, the data show that T cell distribution, function, and gene expression are significantly modified shortly after return from the spaceflight environment.


Assuntos
Citocinas/metabolismo , Ativação Linfocitária , Voo Espacial , Baço/imunologia , Linfócitos T/imunologia , Timo/imunologia , Ausência de Peso , Animais , Linfócitos B/imunologia , Citocinas/genética , Replicação do DNA , Feminino , Citometria de Fluxo , Perfilação da Expressão Gênica , Regulação Neoplásica da Expressão Gênica , Células Matadoras Naturais/imunologia , Ativação Linfocitária/genética , Contagem de Linfócitos , Camundongos , Camundongos Endogâmicos C57BL , Fatores de Tempo
6.
Anticancer Res ; 29(1): 107-18, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19331139

RESUMO

BACKGROUND: Metalloporphyrin antioxidants can protect tissues against radiation-induced damage. However, for effective use in radiotherapy as normal tissue radioprotectants, they must not protect the cancer. The major objectives were to evaluate the effects of Mn (III) tetrakis (N-ethylpyridinium-2-yl) porphyrin (MnTE-2-PyP) on tumor response to radiation and to explore mechanisms responsible for the observed effects. MATERIALS AND METHODS: C57BL/6 mice were subcutaneously (s.c.) injected with RM-9 prostate tumor cells on day 0 and grouped according to treatment with MnTE-2-PyP (s.c. 6 mg/kg/day beginning on day 1 for 16 maximum days), 10 Gray (Gy) single fraction radiation on day 7, a combination of both or neither. Subsets per group and non-tumor bearing controls were evaluated for leukocyte populations, red blood cell (RBC) and platelet characteristics and cytokines on day 12; the remaining mice were followed for tumor growth. RESULTS: Although radiation alone significantly slowed tumor growth and the addition of MnTE-2-PyP resulted in slightly slower tumor progression, the difference between radiation and radiation plus drug was not statistically significant. However, the treatment with drug alone significantly elevated T (helper, Th and cyotoxic, Tc) and natural killer (NK) cells in the spleen, B-cells in the blood and spleen, and the capacity to produce interleukin-2. The addition of the drug to radiation did not ameliorate the depression seen in all the major leukocyte types, but did protect against radiation-induced decreases in RBC counts, hemoglobin and hematocrit. Vascular endothelial growth factor (VEGF) increased in the plasma from both the irradiated groups and a trend for increased transforming growth factor-beta1 (TGF-beta1) was noted with radiation alone. CONCLUSION: MnTE-2-PyP did not protect RM-9 prostate tumors against radiation damage and was not toxic under the conditions used. The drug-induced enhancement of certain immune parameters suggests that MnTE-2-PyP may be beneficial not only as a normal tissue radioprotectant, but also as a facilitator of antitumor immunity.


Assuntos
Antioxidantes/farmacologia , Metaloporfirinas/farmacologia , Neoplasias da Próstata/radioterapia , Protetores contra Radiação/farmacologia , Animais , Plaquetas/efeitos dos fármacos , Plaquetas/efeitos da radiação , Peso Corporal/efeitos dos fármacos , Peso Corporal/efeitos da radiação , Modelos Animais de Doenças , Eritrócitos/efeitos dos fármacos , Eritrócitos/efeitos da radiação , Interleucina-2/biossíntese , Leucócitos/efeitos dos fármacos , Leucócitos/imunologia , Leucócitos/efeitos da radiação , Subpopulações de Linfócitos/efeitos dos fármacos , Subpopulações de Linfócitos/imunologia , Subpopulações de Linfócitos/efeitos da radiação , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Tamanho do Órgão/efeitos dos fármacos , Tamanho do Órgão/efeitos da radiação , Neoplasias da Próstata/sangue , Neoplasias da Próstata/imunologia , Baço/efeitos dos fármacos , Baço/imunologia , Baço/efeitos da radiação , Fator de Crescimento Transformador beta1/sangue , Fator A de Crescimento do Endotélio Vascular/sangue
7.
Int J Radiat Biol ; 85(3): 250-61, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19296339

RESUMO

PURPOSE: To evaluate cluster of differentiation 4(+) (CD4(+)) T cell gene expression and related parameters after whole-body exposure to proton radiation as it occurs in the spaceflight environment. MATERIALS AND METHODS: C57BL/6 mice were irradiated to total doses of 0, 0.01, 0.05, and 0.1 gray (Gy) at 0.1 cGy/h. On day 0 spleens were harvested from a subset in the 0, 0.01 and 0.1 Gy groups; (CD4(+)) T cells were isolated; and expression of 84 genes relevant to T helper (Th) cell function was determined using reverse transcriptase-polymerase chain reaction (RT-PCR). Remaining mice were euthanized on days 0, 4, and 21 for additional analyses. RESULTS: Genes with >2-fold difference and p < 0.05 compared to 0 Gy were noted. After 0.01 Gy, five genes were up-regulated (Ccr5, Cd40, Cebpb, Igsf6, Tnfsf4) and three were down-regulated (Il4ra, Mapk8, Nfkb1). After 0.1 Gy there were nine up-regulated genes (Ccr4, Cd40, Cebpb, Cxcr3, Socs5, Stat4, Tbx21, Tnfrsf4, Tnfsf4); none were down-regulated. On day 0 after 0.01 Gy, CD4(+) T cell counts and CD4:CD8 ratio were low in the spleen (p < 0.05). Spontaneous DNA synthesis in both spleen and blood was lowest in the 0.01 Gy group on day 0; on days 4 and 21 all p values were >0.1. CONCLUSION: The data show that the pattern of gene expression in CD4(+) T cells after protracted low-dose proton irradiation was significantly modified and highly dependent upon total dose. The findings also suggest that low-dose radiation, especially 0.01 Gy, may enhance CD4(+) T cell responsiveness.


Assuntos
Linfócitos T CD4-Positivos/efeitos da radiação , Regulação da Expressão Gênica/efeitos da radiação , Prótons , Animais , Linfócitos T CD4-Positivos/metabolismo , DNA/biossíntese , DNA/sangue , Relação Dose-Resposta à Radiação , Feminino , Perfilação da Expressão Gênica , Contagem de Leucócitos , Camundongos , Camundongos Endogâmicos C57BL , Baço/citologia , Baço/metabolismo , Baço/efeitos da radiação
8.
Phys Med Biol ; 64(11): 115024, 2019 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-30844767

RESUMO

We performed experiments using a triplet of quadrupole permanent magnets to focus protons and compared their dose distributions with unfocused collimated beams using energies and field sizes typically employed in proton radiosurgery. Experiments were performed in a clinical treatment room wherein small-diameter proton beams were focused by a magnet triplet placed immediately upstream of a water tank. The magnets consisted of segments of Sm2Co17 rare-earth permanent magnetic material adhered into Halbach cylinders with nominal field gradients of 100, 150, 200, and 250 T m-1. Unmodulated beams with initial diameters of 3 mm-20 mm were delivered using a single scattering system with nominal energies of 127 and 157 MeV (respective ranges of ~10 cm and 15 cm in water), commonly used for proton radiosurgery at our institution. For comparison, small-diameter unfocused collimated beams were similarly delivered. Transverse and depth dose distributions were measured using radiochromic film and a diode detector, respectively, and compared between the focused and unfocused beams (UNF). The focused beams produced low-eccentricity beam spots (defined by the 80% dose contour) at Bragg depth, with full width at 80% maximum dose values ranging from 3.8 to 7.6 mm. When initial focused beam diameters were larger than matching unfocused diameters (19 of 29 cases), the focused beams peak-to-entrance dose ratios were 13% to 73% larger than UNF. In addition, in 17 of these cases the efficiency of dose delivery to the target was 1.3× to 3.3× larger. Both peak-to-entrance dose ratios and efficiency tended to increase with initial beam diameter, while efficiency also tended to increase with magnet gradient. These experimental results are consistent with our previous Monte Carlo (MC) studies and suggest that a triplet of quadrupole Halbach cylinders could be clinically useful for irradiating small-field radiosurgical targets with fewer beams, lower entrance dose, and shorter treatment times.


Assuntos
Fenômenos Magnéticos , Prótons , Radiocirurgia/métodos , Método de Monte Carlo , Água
9.
Radiat Res ; 169(3): 280-7, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18302490

RESUMO

The health consequences of exposure to low-dose radiation combined with a solar particle event during space travel remain unresolved. The goal of this study was to determine whether protracted radiation exposure alters gene expression and oxidative burst capacity in the liver, an organ vital in many biological processes. C57BL/6 mice were whole-body irradiated with 2 Gy simulated solar particle event (SPE) protons over 36 h, both with and without pre-exposure to low-dose/low-dose-rate photons ((57)Co, 0.049 Gy total at 0.024 cGy/h). Livers were excised immediately after irradiation (day 0) or on day 21 thereafter for analysis of 84 oxidative stress-related genes using RT-PCR; genes up or down-regulated by more than twofold were noted. On day 0, genes with increased expression were: photons, none; simulated SPE, Id1; photons + simulated SPE, Bax, Id1, Snrp70. Down-regulated genes at this same time were: photons, Igfbp1; simulated SPE, Arnt2, Igfbp1, Il6, Lct, Mybl2, Ptx3. By day 21, a much greater effect was noted than on day 0. Exposure to photons + simulated SPE up-regulated completely different genes than those up-regulated after either photons or the simulated SPE alone (photons, Cstb; simulated SPE, Dctn2, Khsrp, Man2b1, Snrp70; photons + simulated SPE, Casp1, Col1a1, Hspcb, Il6st, Rpl28, Spnb2). There were many down-regulated genes in all irradiated groups on day 21 (photons, 13; simulated SPE, 16; photons + simulated SPE, 16), with very little overlap among groups. Oxygen radical production by liver phagocytes was significantly enhanced by photons on day 21. The results demonstrate that whole-body irradiation with low-dose-rate photons, as well as time after exposure, had a great impact on liver response to a simulated solar particle event.


Assuntos
Radiação Cósmica , Fígado/metabolismo , Fígado/efeitos da radiação , Espécies Reativas de Oxigênio/metabolismo , Energia Solar , Simulação de Ambiente Espacial/métodos , Irradiação Corporal Total/métodos , Animais , Relação Dose-Resposta à Radiação , Feminino , Camundongos , Camundongos Endogâmicos C57BL , Estresse Oxidativo/fisiologia , Estresse Oxidativo/efeitos da radiação , Fótons , Doses de Radiação , Voo Espacial
10.
Med Phys ; 35(12): 5708-12, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19175128

RESUMO

Three dimensional grid phantoms offer a number of advantages for measuring imaging related spatial inaccuracies for image guided surgery and radiotherapy. The authors examined the use of rapid prototyping technology for directly fabricating 3D grid phantoms from CAD drawings. We tested three different fabrication process materials, photopolymer jet with acrylic resin (PJ/AR), selective laser sintering with polyamide (SLS/P), and fused deposition modeling with acrylonitrile butadiene styrene (FDM/ABS). The test objects consisted of rectangular arrays of control points formed by the intersections of posts and struts (2 mm rectangular cross section) and spaced 8 mm apart in the x, y, and z directions. The PJ/AR phantom expanded after immersion in water which resulted in permanent warping of the structure. The surface of the FDM/ABS grid exhibited a regular pattern of depressions and ridges from the extrusion process. SLS/P showed the best combination of build accuracy, surface finish, and stability. Based on these findings, a grid phantom for assessing machine-dependent and frame-induced MR spatial distortions was fabricated to be used for quality assurance in stereotactic neurosurgical and radiotherapy procedures. The spatial uniformity of the SLS/P grid control point array was determined by CT imaging (0.6 x 0.6 x 0.625 mm3 resolution) and found suitable for the application, with over 97.5% of the control points located within 0.3 mm of the position specified in CAD drawing and none of the points off by more than 0.4 mm. Rapid prototyping is a flexible and cost effective alternative for development of customized grid phantoms for medical physics quality assurance.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Controle de Qualidade , Resinas Acrílicas/química , Butadienos/química , Diagnóstico por Imagem/métodos , Desenho de Equipamento , Humanos , Nylons/química , Imagens de Fantasmas , Polímeros , Poliestirenos/química , Planejamento da Radioterapia Assistida por Computador , Software , Técnicas Estereotáxicas , Tomografia Computadorizada por Raios X/métodos
11.
In Vivo ; 22(2): 159-69, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18468399

RESUMO

UNLABELLED: The goal of this study was to evaluate, for the first time, the response of bone marrow-derived cell populations to protons mimicking a space radiation environment. MATERIALS AND METHODS: C57BL/6 mice were exposed to 2 Gray (Gy) simulated solar particle event protons (sSPE) over 36 h; energies ranged from 15 to 215 MeV/n and were administered in 10 MeV increments. Acute 2 Gy irradiation with photons (gamma-rays) and protons were administered to different groups at 0.7 Gy/min and 0.9 Gy/min, respectively, for comparison with sSPE. The animals were euthanized on days 4 and 21 post-exposure for analyses. RESULTS: Exposure to radiation, regardless of regimen, resulted in immune depression and other abnormalities in cell populations residing in the blood and spleen; the extent of the radiation damage was somewhat dependent upon body compartment and time postexposure. However, variations were also noted among the three radiation regimens in a number of measurements: relative spleen mass, basal DNA synthesis by leukocytes, white blood cell counts and three-part differentials (lymphocytes, granulocytes, monocytes-macrophages), lymphocyte subpopulations (CD4+ T, CD8+ T, B and NK cells) and erythrocyte and thrombocyte characteristics. CONCLUSION: The data demonstrate that exposure to proton radiation mimicking a solar explosion induces abnormalities in leukocytes, erythrocytes and platelets that may have adverse health consequences. However, the damaging effects of sSPE on leukocytes and platelets were generally less pronounced compared to the other radiation regimens. Results obtained with photons (gamma-rays, X-rays) and monoenergetic protons at space-relevant total doses may not necessarily predict biological responses after exposure to a solar particle event.


Assuntos
Sistema Hematopoético/efeitos da radiação , Prótons/efeitos adversos , Lesões por Radiação , Atividade Solar , Simulação de Ambiente Espacial/métodos , Animais , Plaquetas/efeitos da radiação , Radiação Cósmica , DNA/efeitos da radiação , Relação Dose-Resposta à Radiação , Eritrócitos/efeitos da radiação , Leucócitos/efeitos da radiação , Camundongos , Camundongos Endogâmicos C57BL , Fótons , Baço/efeitos da radiação , Fatores de Tempo
12.
Phys Med Biol ; 63(5): 055010, 2018 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-29369047

RESUMO

The purpose of this project is to investigate the advantages in dose distribution and delivery of proton beams focused by a triplet of quadrupole magnets in the context of potential radiosurgery treatments. Monte Carlo simulations were performed using various configurations of three quadrupole magnets located immediately upstream of a water phantom. Magnet parameters were selected to match what can be commercially manufactured as assemblies of rare-earth permanent magnetic materials. Focused unmodulated proton beams with a range of ~10 cm in water were target matched with passive collimated beams (the current beam delivery method for proton radiosurgery) and properties of transverse dose, depth dose and volumetric dose distributions were compared. Magnetically focused beams delivered beam spots of low eccentricity to Bragg peak depth with full widths at the 90% reference dose contour from ~2.5 to 5 mm. When focused initial beam diameters were larger than matching unfocused beams (10 of 11 cases) the focused beams showed 16%-83% larger peak-to-entrance dose ratios and 1.3 to 3.4-fold increases in dose delivery efficiency. Peak-to-entrance and efficiency benefits tended to increase with larger magnet gradients and larger initial diameter focused beams. Finally, it was observed that focusing tended to shift dose in the water phantom volume from the 80%-20% dose range to below 20% of reference dose, compared to unfocused beams. We conclude that focusing proton beams immediately upstream from tissue entry using permanent magnet assemblies can produce beams with larger peak-to-entrance dose ratios and increased dose delivery efficiencies. Such beams could potentially be used in the clinic to irradiate small-field radiosurgical targets with fewer beams, lower entrance dose and shorter treatment times.


Assuntos
Magnetismo , Método de Monte Carlo , Imagens de Fantasmas , Prótons , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos
13.
Technol Cancer Res Treat ; 6(4 Suppl): 1-7, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17668945

RESUMO

From October 18 to 20, 2006, a symposium, Developing and Understanding a Hospital-based Proton Facility: Bringing Physics Into Medicine, was held at the Renaissance Esmeralda Resort and Spa, Indian Wells, California. The event was offered by the Department of Radiation Medicine at Loma Linda University (LLU), supported by the Telemedicine and Advanced Technology Research Center (TATRC) and the United States Army Medical Research and Materiel Command (USAMRMC). The meeting was intended to discuss factors involved in planning, developing, and operating a hospital-based proton treatment center. It brought together some of the most distinguished physicists, radiation biologists, and radiation oncologists in the world, and more than 100 individuals participated in the three-day educational offering. This overview reports on the event and introduces several papers written by many of the speakers from their presentations, for publication in this issue of Technology in Cancer Research and Treatment. Both the symposium and the papers are appropriate for this journal: exploitation of technology was one of the underlying themes of the symposium.


Assuntos
Departamentos Hospitalares , Neoplasias/radioterapia , Serviço Hospitalar de Radiologia , California , Arquitetura Hospitalar , Prótons
14.
Technol Cancer Res Treat ; 6(4 Suppl): 35-9, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17668950

RESUMO

Ionizing radiation therapy is one of the primary modalities for treating cancers. Ideally, the particle selected to deliver ionizing radiation for routine therapy should control the disease, cause minimal side effects, and be affordable. Two major properties for judging the utility of a particle, physical controllability and selective cell destruction, influence the decision for selection. The proton, at present, has the best combination of capabilities for routine radiation therapy. Heavier ions require further study to determine their role in patient treatment.


Assuntos
Partículas Elementares/uso terapêutico , Radioterapia/métodos , Elétrons , Hélio , Humanos , Mésons , Nêutrons , Fótons , Prótons , Dosagem Radioterapêutica
15.
Anticancer Res ; 27(5A): 3101-9, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17970050

RESUMO

BACKGROUND: Antioxidants have the potential to protect normal tissues against radiation-induced damage, but must not protect tumor cells during radiotherapy. The major objectives were to determine whether a metalloporphyrin antioxidant affects prostate tumor response to radiation and identify possible mechanisms of interaction. MATERIALS AND METHODS: C57BL/6 mice with RM-9 tumor were treated with manganese (III) meso-tetrakis (1,3-diethylimidazolium-2-yl) porphyrin (MnTDE-2-ImP) and 10 gray (Gy) radiation. Tumor volume was quantified and a subset/group was evaluated for hypoxia-inducible factor-1alpha (HIF-1alpha), bone marrow-derived cell populations and cytokines. RESULTS: The addition of MnTDE-2-ImP transiently increased tumor response compared to radiation alone. The group receiving drug plus radiation had reduced intratumoral HIF-1alpha and decreased capacity to secrete TNF-alpha, whereas production of IL-4 was increased. There were no toxicities associated with combination treatment. CONCLUSION: The results demonstrate that MnTDE-2-ImP did not protect the RM-9 prostate tumor against radiation; instead, radiation effectiveness was modestly increased. Possible mechanisms include reduction of radiation-induced HIF-1alpha and an altered cytokine profile.


Assuntos
Metaloporfirinas/farmacologia , Neoplasias da Próstata/tratamento farmacológico , Neoplasias da Próstata/radioterapia , Protetores contra Radiação/farmacologia , Animais , Antioxidantes/farmacologia , Linfócitos B/efeitos dos fármacos , Linfócitos B/efeitos da radiação , Peso Corporal/efeitos dos fármacos , Peso Corporal/efeitos da radiação , Terapia Combinada , Modelos Animais de Doenças , Subunidade alfa do Fator 1 Induzível por Hipóxia/biossíntese , Células Matadoras Naturais/efeitos dos fármacos , Células Matadoras Naturais/efeitos da radiação , Contagem de Leucócitos , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Tamanho do Órgão/efeitos dos fármacos , Tamanho do Órgão/efeitos da radiação , Neoplasias da Próstata/sangue , Baço/anatomia & histologia , Baço/efeitos dos fármacos , Baço/patologia , Baço/efeitos da radiação , Linfócitos T/efeitos dos fármacos , Linfócitos T/efeitos da radiação
16.
Int J Radiat Oncol Biol Phys ; 64(5): 1367-70, 2006 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-16488552

RESUMO

PURPOSE: To evaluate patient tolerance of intrarectal balloons used during conformal prostate irradiation. METHODS AND MATERIALS: A retrospective analysis was performed on 3,561 patients who underwent conformal radiation for prostate cancer. Therapy consisted of proton irradiation of the prostate and seminal vesicles and X-ray treatment of the pelvis when warranted. The number of treatments in which the balloon was tolerated was recorded. Results were stratified according to method of irradiation (protons alone vs. combined proton/X-ray) and method of planning (2D vs. 3D planning of X-ray fields in patients undergoing combination treatment). RESULTS: Of all the patients evaluated, 3,474 (97.6%) tolerated the balloon throughout treatment; 87 (2.4%) declined the balloon for 1 or more treatments and tolerated the balloon for 85.5% of their treatments. Chi-square analysis revealed a significant tolerance advantage in those who received protons alone compared with combination treatment (99.5% vs. 95.7%; p < 0.001). In patients undergoing combination treatment, chi-square analysis did not reveal significant tolerance differences in patients undergoing 3D vs. 2D planning for pelvic X-ray fields (95.74% vs. 95.72%; p = 0.990). CONCLUSIONS: Intrarectal balloons are well tolerated over a course of conformal prostate irradiation.


Assuntos
Cateteres de Demora/efeitos adversos , Neoplasias da Próstata/radioterapia , Radioterapia Conformacional/instrumentação , Reto , Distribuição de Qui-Quadrado , Humanos , Imobilização/instrumentação , Masculino , Terapia com Prótons , Estudos Retrospectivos
17.
Int J Radiat Oncol Biol Phys ; 64(2): 425-34, 2006 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-16257131

RESUMO

PURPOSE: Various radiation techniques and modalities have been used to treat pituitary adenomas. This report details our experience with proton treatment of these tumors. METHODS AND MATERIALS: Forty-seven patients with pituitary adenomas treated with protons, who had at least 6 months of follow-up, were included in this analysis. Forty-two patients underwent a prior surgical resection; 5 were treated with primary radiation. Approximately half the tumors were functional. The median dose was 54 cobalt-gray equivalent. RESULTS: Tumor stabilization occurred in all 41 patients available for follow-up imaging; 10 patients had no residual tumor, and 3 had greater than 50% reduction in tumor size. Seventeen patients with functional adenomas had normalized or decreased hormone levels; progression occurred in 3 patients. Six patients have died; 2 deaths were attributed to functional progression. Complications included temporal lobe necrosis in 1 patient, new significant visual deficits in 3 patients, and incident hypopituitarism in 11 patients. CONCLUSION: Fractionated conformal proton-beam irradiation achieved effective radiologic, endocrinological, and symptomatic control of pituitary adenomas. Significant morbidity was uncommon, with the exception of postradiation hypopituitarism, which we attribute in part to concomitant risk factors for hypopituitarism present in our patient population.


Assuntos
Adenoma/radioterapia , Neoplasias Hipofisárias/radioterapia , Terapia com Prótons , Adenoma/metabolismo , Adenoma/mortalidade , Hormônio Adrenocorticotrópico/metabolismo , Adulto , Fracionamento da Dose de Radiação , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Hipofisárias/metabolismo , Neoplasias Hipofisárias/mortalidade , Radioterapia Conformacional , Estudos Retrospectivos , Tireotropina/metabolismo
18.
Technol Cancer Res Treat ; 5(2): 73-9, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16551127

RESUMO

Of the many ionizing particles discovered so far, only a few are reasonable to consider for radiation therapy. These include photons, protons, neutrons, electrons, mesons, antiprotons, and ions heavier than hydrogen. Most of these particles are used therapeutically to destroy or inactivate malignant and sometimes benign cells. Since the late 1930s, accelerators have been developed that have expanded radiation oncologists' abilities to produce various ionizing particle beams. Over the past decade, radiation oncologists have become increasingly interested in pursuing particles other than the conventional photons that have been used almost exclusively since X-rays were discovered in 1895. Physicians recognize that normal-tissue morbidity from all forms of anti-cancer treatment is the primary factor limiting the success of those treatments. In radiation therapy, all particles mentioned above can destroy any cancer cell; controlling the beam in three dimensions, thus providing the physician with the capability of avoiding normal-tissue injury, is the fundamental deficiency in the use of X-rays (photons). Heavy charged particles possess near-ideal characteristics for exercising control in three dimensions; their primary differences are due to the number of protons contained within their nuclei. As their number of protons increase (atomic number) their ionization density (LET) increases. In selecting the optimal particle for therapy from among the heavy charged particles, one must carefully consider the ionization density created by each specific particle. Ionization density creates both advantages and disadvantages for patient treatment; these factors must be matched with the patients' precise clinical needs. The current state of the art involves studying the clinical advantages and disadvantages of the lightest ion, the proton, as compared to other particles used or contemplated for use. Full analysis must await adequate data developed from long-term studies to determine the precise role of each potential particle for human use. It is expected that one particle beam will emerge as the mainstream for treating human disease, and a small number of particles may emerge in an adjunctive role.


Assuntos
Neoplasias/radioterapia , Medicina Nuclear/métodos , Radioterapia/métodos , Humanos , Radiação Ionizante
19.
Technol Cancer Res Treat ; 5(2): 135-46, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16551133

RESUMO

The dose of radiation that can be safely delivered to cancers residing in sensitive areas such as the lungs is limited by concern for normal tissue damage. Therapies that target tumor vasculature have potential to enhance the efficacy of radiotherapy, with minimal risk for toxicity. We constructed a unique plasmid, pXLG-mEndo, containing the mouse endostatin gene. A significantly greater anti-tumor effect was obtained against Lewis lung carcinoma (LLC) in mice when pXLG-mEndo was combined with radiation compared to radiation alone. Here we report results of cellular and cytokine assessments performed one day after treatment. These analyses were done to obtain baseline data on leukocytes that affect angiogenesis, as well as anti-tumor immunity, and to detect possible treatment-related toxicities. White blood cell counts were dramatically elevated in blood and spleens of untreated tumor-bearing mice, primarily due to granulocytosis. Overall, the effect of radiation was more evident than that of the plasmids (pXLG-mEndo and parental pWS4); radiosensitivity of specific lymphocyte subsets was variable (B > T > NK; CD8+ Tc > CD4+ Th). Tumor presence resulted in dramatically elevated interleukin-2 (IL-2) and decreased tumor necrosis factor-alpha (TNF-alpha) in supernatants of activated splenocytes, but had no significant effect on interferon-gamma (IFN-gamma). Administration of pXLG-mEndo, radiation, or both modified the tumor-induced aberrations in IL-2 and TNF-alpha; IFN-gamma production was decreased by radiation. Red blood cell counts, hemoglobin, and hematocrit were low in tumor-bearing mice, but there were no treatment-related differences among groups. Platelet counts were reduced, whereas their volumes were increased in tumor-bearing mice; both parameters were only slightly affected by either pXLG-mEndo or control plasmid injection, however. The data demonstrate in the Lewis lung carcinoma model that tumor-localized endostatin gene therapy and radiation had significant effects on cells and cytokines that can influence angiogenesis, tumor growth, and immune status.


Assuntos
Carcinoma Pulmonar de Lewis/terapia , Endostatinas/uso terapêutico , Terapia Genética , Neovascularização Patológica/terapia , Animais , Carcinoma Pulmonar de Lewis/irrigação sanguínea , Carcinoma Pulmonar de Lewis/imunologia , Terapia Combinada , Feminino , Vetores Genéticos , Interferon gama/metabolismo , Interferon gama/efeitos da radiação , Interleucina-2/metabolismo , Contagem de Leucócitos , Leucócitos/imunologia , Leucócitos/metabolismo , Leucócitos/patologia , Camundongos , Camundongos Endogâmicos C57BL , Projetos Piloto , Baço/citologia , Baço/imunologia , Baço/metabolismo , Fator de Necrose Tumoral alfa/metabolismo
20.
Technol Cancer Res Treat ; 5(3): 281-4, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16700624

RESUMO

Primary B cell lymphomas of the skull base are uncommon and lack well-defined treatment guidelines. We report a case of diffuse, large B-cell lymphoma of the cavernous sinus with sphenoid sinus and clivial extension, treated with partial resection, chemotherapy, and proton beam irradiation. To our knowledge, this is the first report of a skull-base lymphoma treated with protons. A 53-year-old female presented with a two-month history of diplopia, persistent headaches, and paresthesia over the left side of her mouth. A skull MRI revealed an enhancing mass in the right cavernous sinus and right sphenoid sinus. Transsphenoidal subtotal resection of the mass confirmed the presence of a diffuse, large B-cell lymphoma. Treatment consisted of CHOP-R chemotherapy and locoregional radiation with protons. Locoregional radiation of the lesion required moderate doses, below the radiation tolerance of adjacent normal structures. Conformal protons were utilized to minimize the volume of normal brain receiving radiation. Conformal proton beam radiotherapy to a moderate dose proved valuable in this case because it minimized the volume of normal brain receiving low to moderate doses of radiation.


Assuntos
Linfoma de Células B/radioterapia , Prótons , Neoplasias da Base do Crânio/radioterapia , Anticorpos Monoclonais/uso terapêutico , Anticorpos Monoclonais Murinos , Antineoplásicos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Seio Cavernoso/diagnóstico por imagem , Seio Cavernoso/patologia , Terapia Combinada , Ciclofosfamida/uso terapêutico , Diplopia , Doxorrubicina/uso terapêutico , Feminino , Cefaleia , Humanos , Linfoma de Células B/diagnóstico , Linfoma de Células B/tratamento farmacológico , Pessoa de Meia-Idade , Prednisona/uso terapêutico , Rituximab , Neoplasias da Base do Crânio/diagnóstico , Neoplasias da Base do Crânio/tratamento farmacológico , Tomografia Computadorizada por Raios X , Vincristina/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA