Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Dis Colon Rectum ; 46(12): 1606-16; discussion 1616-8, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14668584

RESUMO

PURPOSE: This multicenter study evaluated the safety and efficacy of radio-frequency energy delivery to the anal canal for the treatment of fecal incontinence. METHODS: Fifty patients at five centers were enrolled. All reported fecal incontinence at least once per week for three months, and medical and/or surgical management failed to help their symptoms. At baseline and at six months, patients completed questionnaires (Cleveland Clinic Florida Fecal Incontinence score (0-20), fecal incontinence-related quality of life, Short Form-36, and visual analog scale) and underwent anorectal manometry, endoanal ultrasound, and pudendal nerve terminal motor latency testing. On an outpatient basis using local anesthesia, radio-frequency energy was delivered via an anoscopic device with multiple needle electrodes (Secca system) to create thermal lesions deep to the mucosa of the anal canal. RESULTS: Forty-three females and seven males (aged 61.1 +/- 13.4 (mean +/- standard deviation); range, 30-80 years) were treated. Mean duration of fecal incontinence was 14.9 years. Treatment time was 37 +/- 9 minutes. At six months, the mean Cleveland Clinic Florida Fecal Incontinence score improved from 14.5 to 11.1 (P < 0.0001). All parameters in the Fecal Incontinence Quality of Life scales were improved (lifestyle (from 2.5-3.1; P < 0.0001); coping (from 1.9-2.4; P < 0.0001), depression (from 2.8-3.3; P = 0.0004); embarrassment (from 1.9-2.5; P < 0.0001)). Responders, as assessed by a systematic referenced analog scale, reported a median 70 percent resolution of symptoms. The mean Short Form-36 social function improved from 64.3 to 76 (P = 0.003). There were no changes in endoanal ultrasound or pudendal nerve terminal motor latency assessment, or in anal manometry. Complications included mucosal ulceration (one superficial, one with underlying muscle injury) and delayed bleeding (n = 1). CONCLUSION: This multicenter trial demonstrates that radio-frequency energy can be safely delivered to the lower rectum and anal canal. The Secca procedure significantly improved the Cleveland Clinic Florida Fecal Incontinence score and the overall quality of life for most patients having undergone the procedure.


Assuntos
Canal Anal/fisiologia , Ablação por Cateter/métodos , Incontinência Fecal/cirurgia , Reto/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Canal Anal/inervação , Canal Anal/cirurgia , Anestesia Local , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Manometria , Pessoa de Meia-Idade , Pacientes Ambulatoriais , Qualidade de Vida , Reto/inervação , Reto/cirurgia , Índice de Gravidade de Doença , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA