Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
J Magn Reson Imaging ; 2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37728325

RESUMO

BACKGROUND: The biomechanical properties of deep and superficial cartilage may be different, yet in vivo MRI validation is required. PURPOSE: To compare the effect of mechanical loading on deep and superficial cartilage in young healthy adults using ultrashort echo time (UTE)-T2* mapping. STUDY TYPE: Prospective, intervention. SUBJECTS: Thirty-one healthy adults (54.8% females, median age = 23 years). FIELD STRENGTH/SEQUENCE: 3-T, PD-FS, and UTE sequences with four echo times (TEs = 0.1, 0.5, 2.8, and 4.0 msec; 0.6 mm isotropic spatial resolution) of the left knee, acquired before and after loading exercise. ASSESSMENT: Quantitative UTE-T2* maps of the entire knee were generated using UTE images of four TEs. In deep and superficial cartilage of patella, medial and lateral femur, medial and lateral tibia cartilage (PC, MFC, LFC, MTC, and LTC), which were segmented manually, cartilage thickness and T2* values before and after loading were measured, extracted, taken averages of, and compared. Scan-rescan repeatability was evaluated. Body weight and body mass index (BMI) data were collected. Physical activity levels were evaluated using International Physical Activity Questionnaire. STATISTICAL TESTS: Paired sample t-tests, paired Wilcoxon Mann-Whitney tests, Pearson and Spearman correlation analyses, Kruskal-Wallis tests with post-hoc Bonferroni correction. A P-value <0.05 was considered statistically significant. RESULTS: The scan-rescan repeatability was good (RMSA-CV < 10%). After exercise, deep cartilage exhibited no significant differences in cartilage thickness (PPC = 0.576, PMTC = 0.991, PMFC = 0.899, PLTC = 0.861, PLFC = 0.290) and T2* values (PPC = 0.914, PMTC = 0.780, PMFC = 0.754, PLTC = 0.327, PLFC = 0.811), which both significantly decreased in superficial PC, MFC, LFC, and MTC. The T2* values of superficial MTC and deep MFC were moderately correlated with higher body weight (ρ = 0.431) and lower BMI (ρ = -0.499), respectively. DATA CONCLUSION: Deep and superficial cartilage may respond differently to mechanical loading as assessed by UTE-T2*. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 3.

2.
Arch Orthop Trauma Surg ; 143(6): 2965-2971, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35767038

RESUMO

BACKGROUND: The anteroposterior (ap) radiograph of the pelvis is decisive in the diagnosis of different pathologies of the hip joint. Technical advantages have reduced the radiation dose of pelvic CT to levels comparable to radiographs. The purpose of this study was to validate if standard radiographic parameters (lateral center edge angle, medial center edge angle, acetabular index, acetabular arc, extrusion index, crossover sign and posterior wall sign) can accurately be determined on radiograph-like projections reconstructed from the CT dataset pre- and postoperatively. METHODS: A consecutive series of patient with symptomatic dysplasia of the hip and a full radiologic workup (radiographs and CT scan pre- and postoperatively) who underwent periacetabular osteotomy were included. Standard radiographic parameters were compared between radiographs and radiograph-like projections by two authors pre- and postoperatively. RESULTS: A total of 16 hips (32 radiographs/32 radiograph-like projections) were included in the study. No significant difference was found between the radiographs and radiograph-like images for all parameter for both examiners. ICC between radiograph and radiograph-like projections for all investigated parameters showed good to excellent reliability (0.78-0.99) pre- and postoperatively. CONCLUSION: Radiograph-like projections show comparable results to radiographs with regard to the important investigated parameters (lateral center edge angle, medial center edge angle, acetabular index, acetabular arc, extrusion index, crossover sign and posterior wall sign). Thus, ultra-low-dose CT scans may reduce the need for conventional radiographs in pre- and postoperative analyses of 3-dimensional hip pathologies in the future, as the advantages increasingly outweigh the disadvantages.


Assuntos
Acetábulo , Articulação do Quadril , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Acetábulo/patologia , Pelve , Tomografia Computadorizada por Raios X
3.
Proc Biol Sci ; 289(1972): 20220015, 2022 04 13.
Artigo em Inglês | MEDLINE | ID: mdl-35414239

RESUMO

In mammals, body-size responses to warming climates are diverse, and the mechanisms underlying these different responses have been little investigated. Using temporal and spatial datasets of three rodent species distributed across different climatic zones in China, we investigated temporal and spatial trends of body size (length and mass), identified the critical drivers of these trends, and inferred the potential causes underlying the distinct body-size responses to the critical drivers. We found that body mass of all species remained stable over time and across space. Body length, however, increased in one species over time and in two species across space. Generally, body-length variation was predicted best by minimum ambient temperature. Moreover, in two species, body length changed linearly with temperature differences between ancestral and colonization areas. These distinct temperature-length patterns may jointly be caused by species-specific temperature sensitivities and experienced magnitudes of warming. We hypothesize that species or populations distributed across distinct temperature gradients evolved different intrinsic temperature sensitivities, which affect how their body sizes respond to warming climates. Our results suggest that size trends associated with climate change should be explored at higher temporal and spatial resolutions, and include clades of species with similar distributions.


Assuntos
Mudança Climática , Roedores , Animais , Tamanho Corporal , Temperatura Corporal , Temperatura
4.
Proc Natl Acad Sci U S A ; 116(8): 2860-2865, 2019 02 19.
Artigo em Inglês | MEDLINE | ID: mdl-30728294

RESUMO

Benthic foraminifera populate a diverse range of marine habitats. Their ability to use alternative electron acceptors-nitrate (NO3-) or oxygen (O2)-makes them important mediators of benthic nitrogen cycling. Nevertheless, the metabolic scaling of the two alternative respiration pathways and the environmental determinants of foraminiferal denitrification rates are yet unknown. We measured denitrification and O2 respiration rates for 10 benthic foraminifer species sampled in the Peruvian oxygen minimum zone (OMZ). Denitrification and O2 respiration rates significantly scale sublinearly with the cell volume. The scaling is lower for O2 respiration than for denitrification, indicating that NO3- metabolism during denitrification is more efficient than O2 metabolism during aerobic respiration in foraminifera from the Peruvian OMZ. The negative correlation of the O2 respiration rate with the surface/volume ratio is steeper than for the denitrification rate. This is likely explained by the presence of an intracellular NO3- storage in denitrifying foraminifera. Furthermore, we observe an increasing mean cell volume of the Peruvian foraminifera, under higher NO3- availability. This suggests that the cell size of denitrifying foraminifera is not limited by O2 but rather by NO3- availability. Based on our findings, we develop a mathematical formulation of foraminiferal cell volume as a predictor of respiration and denitrification rates, which can further constrain foraminiferal biogeochemical cycling in biogeochemical models. Our findings show that NO3- is the preferred electron acceptor in foraminifera from the OMZ, where the foraminiferal contribution to denitrification is governed by the ratio between NO3- and O2.

5.
Eur Radiol ; 31(9): 6793-6801, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33710371

RESUMO

OBJECTIVES: To compare ultra-low-dose CT (ULD-CT) of the osseous pelvis with tin filtration to standard clinical CT (CT), and to assess the quality of computed virtual pelvic radiographs (VRs). METHODS: CT protocols were optimized in a phantom and three pelvic cadavers. Thirty prospectively included patients received both standard CT (automated tube voltage selection and current modulation) and tin-filtered ULD-CT of the pelvis (Sn140kV/50mAs). VRs of ULD-CT data were computed using an adapted cone beam-based projection algorithm and were compared to digital radiographs (DRs) of the pelvis. CT and DR dose parameters and quantitative and qualitative measures (1 = worst, 4 = best) were compared. CT and ULD-CT were assessed for osseous pathologies. RESULTS: Dose reduction of ULD-CT was 84% compared to CT, with a median effective dose of 0.38 mSv (quartile 1-3: 0.37-0.4 mSv) versus 2.31 mSv (1.82-3.58 mSv; p < .001), respectively. Mean dose of DR was 0.37 mSv (± 0.14 mSv). The median signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of bone were significantly higher for CT (64.3 and 21.5, respectively) compared to ULD-CT (50.4 and 18.8; p ≤ .01), while ULD-CT was significantly more dose efficient (figure of merit (FOM) 927.6) than CT (FOM 167.6; p < .001). Both CT and ULD-CT were of good image quality with excellent depiction of anatomy, with a median score of 4 (4-4) for both methods (p = .1). Agreement was perfect between both methods regarding the prevalence of assessed osseous pathologies (p > .99). VRs were successfully calculated and were equivalent to DRs. CONCLUSION: Tin-filtered ULD-CT of the pelvis at a dose equivalent to standard radiographs is adequate for assessing bone anatomy and osseous pathologies and had a markedly superior dose efficiency than standard CT. KEY POINTS: • Ultra-low-dose pelvic CT with tin filtration (0.38 mSv) can be performed at a dose of digital radiographs (0.37 mSv), with a dose reduction of 84% compared to standard CT (2.31 mSv). • Tin-filtered ultra-low-dose CT had lower SNR and CNR and higher image noise than standard CT, but showed clear depiction of anatomy and accurate detection of osseous pathologies. • Virtual pelvic radiographs were successfully calculated from ultra-low-dose CT data and were equivalent to digital radiographs.


Assuntos
Ossos Pélvicos , Estanho , Humanos , Ossos Pélvicos/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia , Tomografia Computadorizada por Raios X
6.
Forensic Sci Med Pathol ; 16(4): 595-604, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32920765

RESUMO

Compared to computed tomography (CT), magnetic resonance imaging (MRI) provides superior visualization of the soft tissue. Recently, the first 7 Tesla (7 T) MRI scanner was approved for clinical use, which will facilitate access to these ultra-high-field MRI scanners for noninvasive examinations and scientific studies on decedents. 7 T MRI has the potential to provide a higher signal-to-noise ratio (SNR), a characteristic that can be directly exploited to improve image quality and invest in attempts to increase resolution. Therefore, evaluating the diagnostic potential of 7 T MRI for forensic purposes, such as assessments of fatal gunshot wounds, was deemed essential. In this article, we present radiologic findings obtained for craniocerebral gunshot wounds in three decedents. The decedents were submitted to MRI examinations using a 7 T MRI scanner that has been approved for clinical use and a clinical 3 T MRI scanner for comparison. We focused on detecting tiny injuries beyond the wound tract caused by temporary cavitation, such as microbleeds. Additionally, 7 T T2-weighted MRI highlighted a dark (hypo intense) zone beyond the permanent wound tract, which was attributed to increased amounts of paramagnetic blood components in damaged tissue. Microbleeds were also detected adjacent to the wound tract in the white matter on 7 T MRI. Based on the findings of radiologic assessments, the advantages and disadvantages of postmortem 7 T MRI compared to 3 T MRI are discussed with regard to investigations of craniocerebral gunshot wounds as well as the potential role of 7 T MRI in the future of forensic science.


Assuntos
Balística Forense , Traumatismos Cranianos Penetrantes/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ferimentos por Arma de Fogo/diagnóstico por imagem , Adulto , Idoso , Encéfalo/diagnóstico por imagem , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X
7.
Environ Sci Technol ; 53(17): 10258-10268, 2019 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-31432678

RESUMO

Carbon dioxide (CO2) capture and storage (CCS) has been discussed as a potentially significant mitigation option for the ongoing climate warming. Natural CO2 release sites serve as natural laboratories to study subsea CO2 leakage in order to identify suitable analytical methods and numerical models to develop best-practice procedures for the monitoring of subseabed storage sites. We present a new model of bubble (plume) dynamics, advection-dispersion of dissolved CO2, and carbonate chemistry. The focus is on a medium-sized CO2 release from 294 identified small point sources around Panarea Island (South-East Tyrrhenian Sea, Aeolian Islands, Italy) in water depths of about 40-50 m. This study evaluates how multiple CO2 seep sites generate a temporally variable plume of dissolved CO2. The model also allows the overall flow rate of CO2 to be estimated based on field measurements of pH. Simulations indicate a release of ∼6900 t y-1 of CO2 for the investigated area and highlight an important role of seeps located at >20 m water depth in the carbon budget of the Panarea offshore gas release system. This new transport-reaction model provides a framework for understanding potential future leaks from CO2 storage sites.


Assuntos
Dióxido de Carbono , Água , Carbonatos , Ilhas , Itália
8.
Anal Chem ; 90(4): 2409-2413, 2018 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-29397690

RESUMO

Poly(vinyl chloride) (PVC) is today one of the most important commodity polymers. Its broad range of applications is due to the presence of plasticizers whose concentration largely impacts the microscopic and the macroscopic properties. Quantifying the concentration of plasticizer in PVC products is therefore of fundamental importance. Thus, in this paper, the applicability of terahertz (THz) time-domain spectroscopy for the characterization of plasticized PVC is for the first time evaluated in a systematic way. It could be demonstrated that the method is able to distinguish between PVC samples with different types and concentrations of plasticizers. Furthermore, a simple, fast, and efficient method is introduced to quantify the concentration of plasticizer in PVC samples of known plasticizer type but different thermal histories. The presented results are of key importance due to the need of reliable noninvasive and nondestructive analytical methods which can deliver onsite information about the remaining plasticizer concentration inside PVC products. Furthermore, it is expected that the proposed approach can be easily extended to other plasticized polymers.

9.
J Environ Manage ; 195(Pt 1): 4-15, 2017 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-27666648

RESUMO

The world's commitment towards land degradation neutrality (LDN) became enshrined in various international agreements and decisions throughout the year 2015. The challenge now becomes one of addressing its operation, in order to achieve these new policy goals and targets by the year 2030. Advancing LDN demands attention to what the concept seeks to achieve, as well as unravelling the perspectives of the key multi-lateral environmental agreements through which progress can be made. The three Rio Conventions (the UN Convention to Combat Desertification (UNCCD), the UN Framework Convention on Climate Change (UNFCCC) and the Convention on Biological Diversity (CBD)) all play key roles in shaping the international LDN governance and implementation context. Their different but related foci create a number of challenges and opportunities for advancing LDN. In this paper we critically analyze the literature to elucidate potential challenges and opportunities in moving LDN towards implementation, considering the mandates and objectives of all three Rio Conventions. We first unpack the concept of LDN's aspirations. We highlight the importance of the definitions and terminology used, and the relationships between those definitions, terms and the actors using them, as well as their implications in framing the range of policy actions and synergies that could benefit progress towards multiple Sustainable Development Goals. We then examine the LDN pilot project spearheaded by the UNCCD to identify key lessons for LDN implementation. Synthesizing these lessons, we present a portfolio of blended interventions that seeks to address the aspirations of the UNCCD, UNFCCC and CBD in the LDN space, identifying synergistic options for national actions to move towards LDN. Overall, our analysis provides insights in advancing LDN from its current position as a policy target, towards synergetic action.


Assuntos
Mudança Climática , Ecossistema , Conservação dos Recursos Naturais , Projetos Piloto , Nações Unidas
10.
Quant Imaging Med Surg ; 14(6): 4141-4154, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38846278

RESUMO

Background: Bone erosion in the sacroiliac joint (SIJ) is highly specific for the diagnosis of axial spondyloarthritis (axSpA) and may indicate early disease progression. The 3D ultrashort echo time (3D-UTE) technique excels in providing clear contrast between the articular cartilage and the bone cortex interface. Additionally, it is emerging as a promising quantitative tool for detecting early cartilage changes. Therefore, this study aimed to evaluate the diagnostic performance of 3D-UTE sequences in identifying bone erosion in the SIJ of patients with axSpA and to clarify the potential of cartilage T2* values as a quantitative biomarker for axSpA. Methods: This prospective study employed convenience and consecutive sampling methods to recruit patients diagnosed with axSpA in Peking University Third Hospital who met the Assessment of Spondyloarthritis International Society (ASAS) criteria and also an equal number of healthy volunteers. After providing informed consent, all participants underwent 3D-UTE sequences and conventional T2* mapping of the SIJs. Two radiologists separately interpreted the bone erosion of each SIJ on 3D-UTE sequences. Erosion detection of SIJs via computed tomography (CT) served as the standard of reference. The T2* values of the cartilage were measured and compared, and the diagnostic efficacy of the T2* value for axSpA diagnosis was evaluated. Results: A total of 32 patients and 32 healthy volunteers were included. The 3D-UTE sequence, as separately assessed by two reviewers in terms of its ability to detect erosions, exhibited a notable level of accuracy. For the two reviewers, the respective diagnostic sensitivities were 94.7% and 92.9%, the specificities were 97.4% and 96.5%, positive predictive values were 96.7% and 95.4%, the negative predictive values were 95.9% and 94.5%, the accuracies were 96.2% and 94.9%, and the areas under the curve (AUCs) were 96.1% and 94.7%. For the detection of erosions, the interreader κ value was 0.949. The T2* values of the SIJ cartilage were significantly higher in patients with axSpA than in healthy volunteers. The intraobserver intraclass correlation coefficients (ICCs) for T2* measurements ranged between 80.5% and 82.2%. Meanwhile, the interobserver ICCs for UTE-T2* and gradient echo T2* measurements were 81.5% and 80.8%, respectively. The AUCs of the UTE-T2* values for discriminating patients with axSpA from the healthy volunteers of the two readers were 73.3% and 71.6%, respectively. Conclusions: 3D-UTE sequences can be used as a reliable morphological imaging technique for detecting bone erosion in the SIJ. Additionally, UTE-T2* values of the cartilage may offer a quantitative method for identifying patients with axSpA.

11.
Invest Radiol ; 59(4): 328-336, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37707864

RESUMO

OBJECTIVES: The aim of this study was to quantify and compare fat fraction (FF) and muscle volume between patients with failed and intact rotator cuff (RC) repair as well as a control group with nonsurgical conservative treatment to define FF cutoff values for predicting the outcome of RC repair. MATERIALS AND METHODS: Patients with full-thickness RC tears who received magnetic resonance imaging (MRI) before and after RC repair including a 2-point Dixon sequence were retrospectively screened. Patients with retear of 1 or more tendons diagnosed on MRI (Sugaya IV-V) were enrolled and matched to patients with intact RC repair (Sugaya I-II) and to a third group with conservatively treated RC tears. Two radiologists evaluated morphological features (Cofield, Patte, and Goutallier), as well as the integrity of the RC after repair (Sugaya). Fat fractions were calculated from the 2-point Dixon sequence, and the RC muscles were segmented semiautomatically to calculate FFs and volume for each muscle. Receiver operator characteristics curves were used to determine FF cutoff values that best predict RC retears. RESULTS: In total, 136 patients were enrolled, consisting of 3 groups: 41 patients had a failed RC repair (58 ± 7 years, 16 women), 50 patients matched into the intact RC repair group, and 45 patients were matched into the conservative treatment group. Receiver operator characteristics curves showed reliable preoperative FF cutoff values for predicting retears at 6.0% for the supraspinatus muscle (0.83 area under the curve [AUC]), 7.4% for the infraspinatus muscle (AUC 0.82), and 8.3% for the subscapularis muscle (0.94 AUC). CONCLUSIONS: Preoperative quantitative FF calculated from 2-point Dixon MRI can be used to predict the risk of retear after arthroscopic RC repair with cutoff values between 6% and 8.3%.


Assuntos
Lesões do Manguito Rotador , Manguito Rotador , Humanos , Feminino , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/cirurgia , Manguito Rotador/patologia , Estudos Retrospectivos , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Lesões do Manguito Rotador/patologia , Tendões , Imageamento por Ressonância Magnética/métodos , Resultado do Tratamento
12.
Invest Radiol ; 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38598670

RESUMO

OBJECTIVES: The aim of this study was to qualitatively and quantitatively assess changes in bovine flexor tendons before and after collagen degradation and at different angles in relation to the static B0 field using 3-dimensional ultra-short echo time (UTE) magnetization transfer (MT) imaging within a clinically feasible acquisition time. MATERIALS AND METHODS: Eight bovine flexor tendons were examined at 3 T magnetic resonance imaging including 3-dimensional UTE MT and UTE T2* research application sequences (acquired within 4:04 and 6:38 minutes, respectively) before and after enzyme-induced degradation. The tendons were divided into 2 groups: group 1 (controls) treated with phosphate-buffered saline and group 2 treated with collagenase I to induce collagen degeneration. Magnetic resonance imaging was repeated at 0, 27, 55, and 90 degrees to the B0 field. To calculate quantitative tissue properties, all tendons were semiautomatically segmented, and changes in quantitative UTE T2* and UTE MT ratios (MTRs) were compared at different angles and between groups. In addition to descriptive statistics, the coefficient of variation was calculated to compare UTE MT and UTE T2* imaging. RESULTS: Ultra-short echo time MTR showed a significantly lower coefficient of variation compared with UTE T2* values, indicating a more robust imaging method (UTE MTR 9.64%-11.25%, UTE T2* 18.81%-24.06%, P < 0.001). Both methods showed good performance in detecting degenerated tendons using histopathology as reference standard, with UTE MT imaging having a better area under the curve than UTE T2* mapping (0.918 vs 0.865). Falsely high UTE T2* values were detected at the 55 degrees acquisition angle, whereas UTE MTR values were robust, that is, insensitive to the MAE. CONCLUSIONS: Ultra-short echo time MT imaging is a reliable method for quantifying tendon degeneration that is robust to the MAE and can be acquired in a clinically reasonable time.

13.
J Craniomaxillofac Surg ; 52(1): 117-126, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37891089

RESUMO

This study aimed to compare preoperative data relevant to third molar surgery based on radiographic orthopantomography (OPG) and orthopantomogram-like MR images (MR-OPG), using five different MR protocols. X-ray-based OPG and OPG-like MRI reconstructions from DESS, SPACE-STIR, SPACE-SPAIR, T1-VIBE-Dixon, and UTE sequences were acquired in 11 patients undergoing third molar surgery, using a 15-channel mandibular coil. Qualitative (image quality, susceptibility to artifacts, positional relationship, contact/non-contact of the inferior alveolar nerve (IAN), relationship to maxillary sinus, IAN continuity, root morphology) and quantitative (tooth length, retromolar distance, distance to the IAN, and distance to the mandible margin) parameters of the maxillary and mandibular third molars were assessed regarding inter-reader agreement and quantitative discrepancies by three calibrated readers. Radiation-free MR-OPGs generated within clinically tolerable acquisition times, which exhibited high image quality and low susceptibility to artifacts, showed no significant differences compared with X-ray-based OPGs regarding the assessment of quantitative parameters. UTE MR-OPGs provided radiographic-like images and were best suited for assessing qualitative preoperative data (positional relationship, nerve contact/non-contact, and dental root morphology) relevant to third molar surgery. For continuous and focal nerve imaging, DESS MR-OPG was superior. MR-OPGs could represent a shift towards indication-specific and modality-oriented perioperative imaging in high-risk oral and maxillofacial surgery.


Assuntos
Dente Impactado , Traumatismos do Nervo Trigêmeo , Humanos , Dente Serotino/diagnóstico por imagem , Dente Serotino/cirurgia , Raios X , Radiografia Panorâmica/métodos , Imageamento por Ressonância Magnética/métodos , Dente Impactado/cirurgia , Extração Dentária , Espectroscopia de Ressonância Magnética , Nervo Mandibular , Mandíbula/diagnóstico por imagem , Mandíbula/cirurgia , Mandíbula/inervação , Traumatismos do Nervo Trigêmeo/diagnóstico por imagem
14.
Bone ; 181: 117031, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38311304

RESUMO

INTRODUCTION: Conventional bone imaging methods primarily use X-ray techniques to assess bone mineral density (BMD), focusing exclusively on the mineral phase. This approach lacks information about the organic phase and bone water content, resulting in an incomplete evaluation of bone health. Recent research highlights the potential of ultrashort echo time magnetic resonance imaging (UTE MRI) to measure cortical porosity and estimate BMD based on signal intensity. UTE MRI also provides insights into bone water distribution and matrix organization, enabling a comprehensive bone assessment with a single imaging technique. Our study aimed to establish quantifiable UTE MRI-based biomarkers at clinical field strength to estimate BMD and microarchitecture while quantifying bound water content and matrix organization. METHODS: Femoral bones from 11 cadaveric specimens (n = 4 males 67-92 yrs of age, n = 7 females 70-95 yrs of age) underwent dual-echo UTE MRI (3.0 T, 0.45 mm resolution) with different echo times and high resolution peripheral quantitative computed tomography (HR-pQCT) imaging (60.7 µm voxel size). Following registration, a 4.5 mm HR-pQCT region of interest was divided into four quadrants and used across the multi-modal images. Statistical analysis involved Pearson correlation between UTE MRI porosity index and a signal-intensity technique used to estimate BMD with corresponding HR-pQCT measures. UTE MRI was used to calculate T1 relaxation time and a novel bound water index (BWI), compared across subregions using repeated measures ANOVA. RESULTS: The UTE MRI-derived porosity index and signal-intensity-based estimated BMD correlated with the HR-pQCT variables (porosity: r = 0.73, p = 0.006; BMD: r = 0.79, p = 0.002). However, these correlations varied in strength when we examined each of the four quadrants (subregions, r = 0.11-0.71). T1 relaxometry and the BWI exhibited variations across the four subregions, though these differences were not statistically significant. Notably, we observed a strong negative correlation between T1 relaxation time and the BWI (r = -0.87, p = 0.0006). CONCLUSION: UTE MRI shows promise for being an innocuous method for estimating cortical porosity and BMD parameters while also giving insight into bone hydration and matrix organization. This method offers the potential to equip clinicians with a more comprehensive array of imaging biomarkers to assess bone health without the need for invasive or ionizing procedures.


Assuntos
Osso Cortical , Imageamento por Ressonância Magnética , Masculino , Feminino , Humanos , Criança , Estudos de Viabilidade , Microtomografia por Raio-X , Osso Cortical/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Água
15.
Invest Radiol ; 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38960863

RESUMO

OBJECTIVES: The aim of this study was to compare the image quality of 7 T turbo spin echo (TSE) knee images acquired with varying factors of parallel-imaging acceleration reconstructed with deep learning (DL)-based and conventional algorithms. MATERIALS AND METHODS: This was a prospective single-center study. Twenty-three healthy volunteers underwent 7 T knee magnetic resonance imaging. Two-, 3-, and 4-fold accelerated high-resolution fat-signal-suppressing proton density (PD-fs) and T1-weighted coronal 2D TSE acquisitions with an encoded voxel volume of 0.31 × 0.31 × 1.5 mm3 were acquired. Each set of raw data was reconstructed with a DL-based and a conventional Generalized Autocalibrating Partially Parallel Acquisition (GRAPPA) algorithm. Three readers rated image contrast, sharpness, artifacts, noise, and overall quality. Friedman analysis of variance and the Wilcoxon signed rank test were used for comparison of image quality criteria. RESULTS: The mean age of the participants was 32.0 ± 8.1 years (15 male, 8 female). Acquisition times at 4-fold acceleration were 4 minutes 15 seconds (PD-fs, Supplemental Video is available at http://links.lww.com/RLI/A938) and 3 minutes 9 seconds (T1, Supplemental Video available at http://links.lww.com/RLI/A939). At 4-fold acceleration, image contrast, sharpness, noise, and overall quality of images reconstructed with the DL-based algorithm were significantly better rated than the corresponding GRAPPA reconstructions (P < 0.001). Four-fold accelerated DL-reconstructed images scored significantly better than 2- to 3-fold GRAPPA-reconstructed images with regards to image contrast, sharpness, noise, and overall quality (P ≤ 0.031). Image contrast of PD-fs images at 2-fold acceleration (P = 0.087), image noise of T1-weighted images at 2-fold acceleration (P = 0.180), and image artifacts for both sequences at 2- and 3-fold acceleration (P ≥ 0.102) of GRAPPA reconstructions were not rated differently than those of 4-fold accelerated DL-reconstructed images. Furthermore, no significant difference was observed for all image quality measures among 2-fold, 3-fold, and 4-fold accelerated DL reconstructions (P ≥ 0.082). CONCLUSIONS: This study explored the technical potential of DL-based image reconstruction in accelerated 2D TSE acquisitions of the knee at 7 T. DL reconstruction significantly improved a variety of image quality measures of high-resolution TSE images acquired with a 4-fold parallel-imaging acceleration compared with a conventional reconstruction algorithm.

16.
Artigo em Inglês | MEDLINE | ID: mdl-38997121

RESUMO

BACKGROUND AND PURPOSE: Assessing treatment success of intracranial aneurysms treated with Woven EndoBridge (WEB) devices using MRI is important in follow-up imaging. Depicting both the device configuration as well as reperfusion is challenging due to susceptibility artefacts. We evaluated the usefulness of contrast-enhanced 3D-Ultrashort Echo-Time (UTE) sequence in this setting. MATERIALS AND METHODS: In this prospective study, 12 patients (9 female) with 15 treated aneurysms were included. These 12 patients underwent 18 MRI examinations. Follow-up UTE-MRI controls were performed on the same 3-Tesla scanner. We compared the visualization of device configuration, artifact-related virtual stenosis of the parent vessel and WEB occlusion scale in 3D isotropic UTE-MRI post-contrast with standard time-of-flight (TOF) MR-angiography with (CE) and without intravenous contrast as well as DSA. Two interventional neuroradiologists rated the images separately and in consensus. RESULTS: Visualization of the WEB device position and configuration was rated superior or highly superior using the UTE sequence in 17/18 MRIs compared to TOF-MRA. Artifact-related virtual stenosis of the parent vessel was significantly lower in UTE-MRI compared to TOF and CE-TOF. Reperfusion was visible in 8/18 controls in DSA. TOF was able to grade reperfusion correctly in 16 cases, CE-TOF in 16 cases and UTE in 17 cases. CONCLUSIONS: Contrast-enhanced UTE is a novel MRI sequence that shows benefit compared to standard sequences in non-invasive and radiation-free follow-up imaging of intracranial aneurysms treated using the WEB-device. ABBREVIATIONS: ACoA = anterior communicating artery, BA = basilar artery, CEA = contrast enhanced angiography, ICA = internal carotid artery, MCA = middle cerebral artery, PCom = posterior communicating artery TOF-CE = contrast enhanced time-of-flight angiography, UTE = ultra-short echo time, WEB = woven endobridge.

17.
J Neurol ; 2024 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-39003428

RESUMO

BACKGROUND AND OBJECTIVES: In multiple sclerosis (MS), slowly expanding lesions were shown to be associated with worse disability and prognosis. Their timely detection from cross-sectional data at early disease stages could be clinically relevant to inform treatment planning. Here, we propose to use multiparametric, quantitative MRI to allow a better cross-sectional characterization of lesions with different longitudinal phenotypes. METHODS: We analysed T1 and T2 relaxometry maps from a longitudinal cohort of MS patients. Lesions were classified as enlarging, shrinking, new or stable based on their longitudinal volumetric change using a newly developed automated technique. Voxelwise deviations were computed as z-scores by comparing individual patient data to T1, T2 and T2/T1 normative values from healthy subjects. We studied the distribution of microstructural properties inside lesions and within perilesional tissue. RESULTS AND CONCLUSIONS: Stable lesions exhibited the highest T1 and T2 z-scores in lesion tissue, while the lowest values were observed for new lesions. Shrinking lesions presented the highest T1 z-scores in the first perilesional ring while enlarging lesions showed the highest T2 z-scores in the same region. Finally, a classification model was trained to predict the longitudinal lesion type based on microstructural metrics and feature importance was assessed. Z-scores estimated in lesion and perilesional tissue from T1, T2 and T2/T1 quantitative maps carry discriminative and complementary information to classify longitudinal lesion phenotypes, hence suggesting that multiparametric MRI approaches are essential for a better understanding of the pathophysiological mechanisms underlying disease activity in MS lesions.

18.
Artigo em Inglês | MEDLINE | ID: mdl-23749328

RESUMO

Thermophilic desert ants-Cataglyphis, Ocymyrmex, and Melophorus species inhabiting the arid zones of the Palaearctic region, southern Africa and central Australia, respectively-are solitary foragers, which have been considered to lack any kind of chemical recruitment. Here we show that besides mainly employing the solitary mode of food retrieval Ocymyrmex robustior regularly exhibits group recruitment to food patches that cannot be exploited individually. Running at high speed to recruitment sites that may be more than 60 m apart from the nest a leading ant, the recruiter, is followed by a loose and often quite dispersed group of usually 2-7 recruits, which often overtake the leader, or may lose contact, fall back and return to the nest. As video recordings show the leader, while continually keeping her gaster in a downward position, intermittently touches the surface of the ground with the tip of the gaster most likely depositing a volatile pheromone signal. These recruitment events occur during the entire diurnal activity period of the Ocymyrmex foragers, that is, even at surface temperatures of more than 60 °C. They may provide promising experimental paradigms for studying the interplay of orientation by chemical signals and path integration as well as other visual guidance routines.


Assuntos
Formigas/fisiologia , Comportamento Animal/fisiologia , Comportamento de Retorno ao Território Vital/fisiologia , Orientação/fisiologia , Animais , Clima Desértico
19.
Magn Reson Imaging ; 103: 48-53, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37385353

RESUMO

Increasing the temporal resolution of the blood­oxygen level-dependent (BOLD) response is usually accompanied by a decrease in repetition time and therefore also a reduction of the magnetic resonance (MR) signal due to incomplete T1 relaxation and thus a loss of signal-to-noise ratio (SNR). A previous data reordering method can achieve higher temporal sampling rate without the loss of SNR but at the cost of increased scan time. In this proof-of-principle work, we show that combining HiHi reshuffling with multiband acceleration allows us to measure the in vivo BOLD response with a 75-ms sampling rate that is decoupled from the acquisition repetition time (here 1.5 s and hence higher SNR) while covering the entire forebrain with 60 2-mm slices in a ~ 35-min scan. We provide single-voxel time-courses of the BOLD responses in the primary visual and primary motor cortices in three fMRI experiments on a 7 T scanner - 1 male (scanned twice on different days for test-retest reproducibility) and 1 female participant.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Masculino , Feminino , Imageamento por Ressonância Magnética/métodos , Razão Sinal-Ruído , Reprodutibilidade dos Testes , Processamento de Imagem Assistida por Computador/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Mapeamento Encefálico/métodos
20.
Polymers (Basel) ; 15(8)2023 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-37112071

RESUMO

The increasing demand for renewable raw materials and lightweight composites leads to an increasing request for natural fiber composites (NFC) in series production. In order to be able to use NFC competitively, they must also be processable with hot runner systems in injection molding series production. For this reason, the influences of two hot runner systems on the structural and mechanical properties of Polypropylene with 20 wt.% regenerated cellulose fibers (RCF) were investigated. Therefore, the material was processed into test specimens using two different hot runner systems (open and valve gate) and six different process settings. The tensile tests carried out showed very good strength for both hot runner systems, which were max. 20% below the reference specimen processed with a cold runner and, however, significantly influenced by the different parameter settings. Fiber length measurements with the dynamic image analysis showed approx. 20% lower median values of GF and 5% lower of RCF through the processing with both hot runner systems compared to the reference, although the influence of the parameter settings was small. The X-ray microtomography performed on the open hot runner samples showed the influences of the parameter settings on the fiber orientation. In summary, it was shown that RCF composites can be processed with different hot runner systems in a wide process window. Nevertheless, the specimens of the setting with the lowest applied thermal load showed the best mechanical properties for both hot runner systems. It was furthermore shown that the resulting mechanical properties of the composites are not only due to one structural property (fiber length, orientation, or thermally induced changes in fiber properties) but are based on a combination of several material- and process-related properties.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA