1.
J Clin Lab Anal ; 32(1)2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28220976

RESUMO

BACKGROUND: There has been an increasing desire for the use of point-of-care testing (POCT) by both primary care clinicians and patients. This study aimed to evaluate the performance of a new POCT analyzer for hemoglobin A1c (HbA1c) testing. METHODS: We assessed the accuracy, precision, and linearity of the POCT HbA1c analyzer (A1C EZ 2.0) with the Tosoh G8 Analyzer as comparative instrument, following the Clinical and Laboratory Standards Institute (CLSI) protocols. We evaluated sensitivity and specificity of the A1C EZ 2.0 in the clinical diagnosis of diabetes among 842 subjects from 79 communities in Beijing, China. RESULTS: Using regression analysis, the slope of the A1C EZ 2.0 vs the Tosoh G8 Analyzer was 0.9938, with an intercept of 0.0964 and a concordance correlation coefficient of 0.978. For precision, the reproducibility of CV (CVT ) were 3.7% and 2.7% at a lower (36 mmol/mol (5.4%)) and higher (107 mmol/mol (11.9%)) level of HbA1c respectively. The area under the receiver operating characteristic (ROC) curve for clinical diagnosis of diabetes was 0.911 with the HbA1c cut-off value of 44 mmol/mol (6.14%). At the HbA1c level of 48 mmol/mol (6.5%), the sensitivity and specificity were76.1% and 86.6%. CONCLUSION: The A1C EZ 2.0 has a high accuracy and precision, with a wide range of linearity, compared to a comparative laboratory instrument. It met analytical quality specifications and could be suitable for the clinical management of diabetes mellitus.


Assuntos
Diabetes Mellitus/diagnóstico , Hemoglobinas Glicadas/análise , Testes Imediatos , Adulto , Análise Química do Sangue/métodos , Diabetes Mellitus/sangue , Feminino , Humanos , Modelos Lineares , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Lab Med ; 48(2): 148-153, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-28371852

RESUMO

BACKGROUND: To assess the usefulness of commutable secondary reference materials with International Federation of Clinical Chemistry (IFCC)-assigned values, for improving the quality of hemoglobin A1c (HbA 1c ) determination. METHODS: We recalibrated and evaluated 3 point-of-care-test (POCT) devices via 3 different method-specific central laboratory analyzers that were calibrated using commutable specimens with IFCC-assigned values. The staff members who performed POCT were also evaluated before and after training. RESULTS: HbA 1c levels measured with POCT devices showed significantly lesser bias after external mathematical calibration. The interlaboratory CVs for HbA 1c measurements decreased from 12% to 4% after training of POCT-device-operating personnel in the NycoCard group. The CVs in the DCA Vantage and Afinion groups also improved after training. CONCLUSION: Calibration of laboratory devices by specimens with IFCC-assigned values and by external mathematical calibration could improve the accuracy of POCT HbA 1c measurements. Also, standardized training could improve precision in POCT HbA 1c measurements, especially for semiautomated HbA 1c POCT devices.


Assuntos
Análise Química do Sangue/normas , Hemoglobinas Glicadas/análise , Sistemas Automatizados de Assistência Junto ao Leito/normas , Calibragem , Humanos , Modelos Lineares , Valores de Referência
3.
Nan Fang Yi Ke Da Xue Xue Bao ; 37(4): 494-498, 2016 Apr 20.
Artigo em Zh | MEDLINE | ID: mdl-28446402

RESUMO

OBJECTIVE: To investigate the role of interleukin-17 (IL-17) in alveolar fluid clearance in mice with acute lung injury (ALI) and explore the possible mechanism. METHODS: Sixteen IL-17-knockout mice and 16 wild-type mice were both randomized for intratracheal instillation of PBS (control) on lipopolysaccharide (LPS) to induce ALI. Forty-eight hours after the treatments, the wet-dry ratio (W/D) of the lungs, IL-8 in the bronchoalveolar lavage fluid (BALF) and histopathological changes of the lung tissues were examined. The expressions of epithelial sodium channel α subunit (α-ENaC) was detected with Western blotting and liver kinase B1 (LKB1) was detected with immunohistochemistry. RESULTS: Compared with wild-type mice treated with LPS, IL-17 knockout mice showed significantly decreased W/D of the lungs (9.739∓3.3 vs 5.351∓0.56) and IL-8 level in the BALF (67.50∓7.33 vs 41.00∓3.16 pg/mL) following LPS challenge. Pathological examination revealed reduced alveolar edema fluid aggregations and lower lung injury score in IL-17 knockout mice with also higher expression levels of ENaC and LKB1 compared with the wild-type mice. CONCLUSION: Knocking out IL-17 in mice not only alleviates inflammation of the lung tissue following ALI but also reduces the loss of ENaC protein and promotes alveolar fluid clearance, mechanism of which is probably associated with LKB1.


Assuntos
Lesão Pulmonar Aguda/metabolismo , Líquido da Lavagem Broncoalveolar/química , Interleucina-17/metabolismo , Proteínas Quinases Ativadas por AMP , Animais , Canais Epiteliais de Sódio/metabolismo , Técnicas de Inativação de Genes , Interleucina-17/genética , Interleucina-8/metabolismo , Lipopolissacarídeos , Pulmão/patologia , Camundongos , Proteínas Serina-Treonina Quinases/metabolismo
4.
Huan Jing Ke Xue ; 35(2): 592-6, 2014 Feb.
Artigo em Zh | MEDLINE | ID: mdl-24812952

RESUMO

The correlation of substrate structure and hydraulic characteristics was studied by numerical simulation combined with experimental method. The numerical simulation results showed that the permeability coefficient of matrix had a great influence on hydraulic efficiency in subsurface flow constructed wetlands. The filler with a high permeability coefficient had a worse flow field distribution in the constructed wetland with single layer structure. The layered substrate structure with the filler permeability coefficient increased from surface to bottom could avoid the short-circuited flow and dead-zones, and thus, increased the hydraulic efficiency. Two parallel pilot-scale constructed wetlands were built according to the numerical simulation results, and tracer experiments were conducted to validate the simulation results. The tracer experiment result showed that hydraulic characteristics in the layered constructed wetland were obviously better than that in the single layer system, and the substrate effective utilization rates were 0.87 and 0.49, respectively. It was appeared that numerical simulation would be favorable for substrate structure optimization in subsurface flow constructed wetlands.


Assuntos
Eliminação de Resíduos Líquidos/métodos , Áreas Alagadas , Modelos Teóricos
5.
Clin Chim Acta ; 433: 249-53, 2014 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-24675057

RESUMO

BACKGROUND: POCT for HbA1C is widely used in China. However, the lack of traceability of POCT leads to poor comparability of patient results. METHODS: The first step was the evaluation of the precision of NycoCard and DCA by using two-level patient specimens. The second step was the calibration of the central laboratory instrument G8 HBA1C Variant with samples whose values had been assigned by an IFCC reference method. The third step was the assignment of values to 50 fresh whole blood patient specimens by this calibrated G8. The fourth step was to use these 50 fresh whole blood patient specimens to calibrate and to revise the POCT instruments. The fifth step was to confirm whether these 50 specimens were required through mathematical calculations. RESULTS: The low and high CVs at levels were 3.61% and 1.85% for NycoCard but 1.71% and 2.85% for DCA. The linear equation of NycoCard to calibrated G8 and that of DCA to calibrated G8 were Y=0.8530X+0.6409 and Y=0.8995X+0.3891, respectively, and the correlation coefficient for every POCT instrument was greater than 0.985. By external calibration of POCT instruments, the mean deviation detected by NycoCard was reduced from -4.0±3.4mmol/mol to 0.5±3.9mmol/mol, and that by DCA went down to 0.2±3.3mmol/mol. The minimum specimen size for the external calibration of POCT instrument was 10. CONCLUSION: POCT measurement traceability can be established by external calibration. Using an external calibration mode improves the comparability of POCT patient results.


Assuntos
Análise Química do Sangue/normas , Hemoglobinas Glicadas/análise , Sistemas Automatizados de Assistência Junto ao Leito/normas , Calibragem , Humanos , Padrões de Referência