Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Med Microbiol ; 73(5)2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38771623

RESUMO

The emergent fungal pathogen Candida auris is increasingly recognised as an important cause of healthcare-associated infections globally. It is highly transmissible, adaptable, and persistent, resulting in an organism with significant outbreak potential that risks devastating consequences. Progress in the ability to identify C. auris in clinical specimens is encouraging, but laboratory diagnostic capacity and surveillance systems are lacking in many countries. Intrinsic resistance to commonly used antifungals, combined with the ability to rapidly acquire resistance to therapy, substantially restricts treatment options and novel agents are desperately needed. Despite this, outbreaks can be interrupted, and mortality avoided or minimised, through the application of rigorous infection prevention and control measures with an increasing evidence base. This review provides an update on epidemiology, the impact of the COVID-19 pandemic, risk factors, identification and typing, resistance profiles, treatment, detection of colonisation, and infection prevention and control measures for C. auris. This review has informed a planned 2024 update to the United Kingdom Health Security Agency (UKHSA) guidance on the laboratory investigation, management, and infection prevention and control of Candida auris. A multidisciplinary response is needed to control C. auris transmission in a healthcare setting and should emphasise outbreak preparedness and response, rapid contact tracing and isolation or cohorting of patients and staff, strict hand hygiene and other infection prevention and control measures, dedicated or single-use equipment, appropriate disinfection, and effective communication concerning patient transfers and discharge.


Assuntos
Antifúngicos , COVID-19 , Candida auris , Candidíase , Controle de Infecções , Humanos , Candidíase/prevenção & controle , Candidíase/epidemiologia , Candidíase/tratamento farmacológico , Candidíase/microbiologia , Controle de Infecções/métodos , Candida auris/efeitos dos fármacos , COVID-19/prevenção & controle , COVID-19/epidemiologia , Antifúngicos/uso terapêutico , Antifúngicos/farmacologia , Inglaterra/epidemiologia , Infecção Hospitalar/prevenção & controle , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/microbiologia , SARS-CoV-2 , Farmacorresistência Fúngica , Candida/efeitos dos fármacos , Candida/classificação , Candida/isolamento & purificação , Surtos de Doenças/prevenção & controle
2.
Artigo em Inglês | MEDLINE | ID: mdl-37082739

RESUMO

Objectives: Upper gastrointestinal endoscopies are aerosol-generating procedures, increasing the risk of spreading airborne pathogens. We aim to quantify the mitigation of airborne particles via improved ventilation, specifically laminar flow theatres and portable high-efficiency particulate air (HEPA) filters, during and after upper gastrointestinal endoscopies. Methods: This observational study included patients undergoing routine upper gastrointestinal endoscopy in a standard endoscopy room with 15-17 air changes per hour, a standard endoscopy room with a portable HEPA filtration unit, and a laminar flow theatre with 300 air changes per hour. A particle counter (diameter range 0.3 µm-25 µm) took measurements 10 cm from the mouth. Three analyses were performed: whole procedure particle counts, event-based counts, and air clearance estimation using post-procedure counts. Results: Compared to a standard endoscopy room, for whole procedures we observe a 28.5x reduction in particle counts in laminar flow (p < 0.001) but no significant effect of HEPA filtration (p = 0.50). For event analysis, we observe for lateral flow theatres reduction in particles >5 µm for oral extubation (12.2x, p < 0.01), reduction in particles <5 µm for coughing/gagging (6.9x, p < 0.05), and reduction for all sizes in anesthetic throat spray (8.4x, p < 0.01) but no significant effect of HEPA filtration. However, we find that in the fallow period between procedures HEPA filtration reduces particle clearance times by 40%. Conclusions: Laminar flow theatres are highly effective at dispersing aerosols immediately after production and should be considered for high-risk cases where patients are actively infectious or the supply of personal protective equipment is limited. Portable HEPA filers can safely reduce the fallow time between procedures by 40%.

4.
Infect Prev Pract ; 3(2): 100125, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34368742

RESUMO

BACKGROUND: Carbapenemase Producing Enterobacterales (CPE) are a global health concern. Nosocomial outbreaks have been reported globally with patient-to-patient transmission felt to be the most frequent route of cross-transmission. AIM: To describe the investigation and control of an outbreak of healthcare-associated New Delhi Metallo-beta-lactamase (NDM) CPE on a haematology ward, over 2 months. METHODS: Four patients acquired CPE; all had gastrointestinal tract colonisation with two subsequently developing bacteraemias. The outbreak team performed a retrospective review, prospective case finding and environmental sampling using swabs, settle plates, air and water sampling. Immediate control measures were implemented including appropriate isolation of cases and additional ward cleaning with chlorine disinfectant, ultra-violet light decontamination and hydrogen peroxide. FINDINGS: Following two cases of nosocomial acquired CPE prospective case finding identified two further cases. 4.6% of the initial environmental samples were positive for CPE including from waste water sites, the ward sluice and the ward kitchen. Three of the four CPE isolates were identical on pulse field gel electrophoresis (PFGE) typing. Detection of the CPE from the ward kitchen environmental samples suggests a possible role for cross transmission. CONCLUSION: This is the first CPE outbreak report to highlight the role of a ward kitchen as a possible source of cross-transmission. In view of this we suggest ward kitchens are reviewed and investigated in nosocomial CPE outbreaks.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA