Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 31(Pt 1): 55-64, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37930257

RESUMO

X-ray photon correlation spectroscopy (XPCS) holds strong promise for observing atomic-scale dynamics in materials, both at equilibrium and during non-equilibrium transitions. Here an in situ XPCS study of the relaxor ferroelectric PbMg1/3Nb2/3O3 (PMN) is reported. A weak applied AC electric field generates strong response in the speckle of the diffuse scattering from the polar nanodomains, which is captured using the two-time correlation function. Correlated motions of the Bragg peak are also observed, which indicate dynamic tilting of the illuminated volume. This tilting quantitatively accounts for the observed two-time speckle correlations. The magnitude of the tilting would not be expected solely from the modest applied field, since PMN is an electrostrictive material with no linear strain response to the field. A model is developed based on non-uniform static charging of the illuminated surface spot by the incident micrometre-scale X-ray beam and the electrostrictive material response to the combination of static and dynamic fields. The model qualitatively explains the direction and magnitude of the observed tilting, and predicts that X-ray-induced piezoresponse could be an important factor in correctly interpreting results from XPCS and nanodiffraction studies of other insulating materials under applied AC field or varying X-ray illumination.

2.
Phys Chem Chem Phys ; 26(26): 18089-18101, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38895844

RESUMO

Structure at the nanoscale in the organic phase of liquid-liquid extraction systems is often tied to separation performance. However, the weak interactions that drive extractant assembly lead to poorly defined structures that are challenging to identify. Here, we investigate the mechanism of water extraction for a malonamide extractant commonly applied to f-element separations. We measure extractant concentration fluctuations in the organic phase with small angle X-ray scattering (SAXS) before and after contact with water at fine increments of extractant concentration, finding no qualitative changes upon water uptake that might suggest significant nanoscopic reorganization of the solution. The critical composition for maximum fluctuation intensity is consistent with small water-extractant adducts. The extractant concentration dependence of water extraction is consistent with a power law close to unity in the low concentration regime, suggesting the formation of 1 : 1 water-extractant adducts as the primary extraction mechanism at low concentration. At higher extractant concentrations, the power law slope increases slightly, which we find is consistent with activity effects modeled using Flory-Huggins theory without introduction of additional extractant-water species. Molecular dynamics simulations are consistent with these findings. The decrease in interfacial tension with increasing extractant concentration shows a narrow plateau region, but it is not correlated with any change in fluctuation or water extraction trends, further suggesting no supramolecular organization such as reverse micellization. This study suggests that water extraction in this system is particularly simple: it relies on a single mechanism at all extractant concentrations, and only slightly enhances the concentration fluctuations characteristic of the dry binary extractant/diluent mixture.

3.
Phys Chem Chem Phys ; 25(24): 16389-16403, 2023 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-37293887

RESUMO

Extractant aggregation in liquid-liquid extraction organic phases impacts extraction energetics and is related to the deleterious efficiency-limiting liquid-liquid phase transition known as third phase formation. Using small angle X-ray scattering, we find that structural heterogeneities across a wide range of compositions in binary mixtures of malonamide extractants and alkane diluents are well described by Ornstein-Zernike scattering. This suggests that structure in these simplified organic phases originates from the critical point associated with the liquid-liquid phase transition. To confirm this, we measure the temperature dependence of the organic phase structure, finding critical exponents consistent with the 3D Ising model. Molecular dynamics simulations were also consistent with this mechanism for extractant aggregation. Due to the absence of water or any other polar solutes required to form reverse-micellar-like nanostructures, these fluctuations are inherent to the binary extractant/diluent mixture. We also show how the molecular structure of the extractant and diluent modulate these critical concentration fluctuations by shifting the critical temperature: critical fluctuations are suppressed by increasing extractant alkyl tail lengths or decreasing diluent alkyl chain lengths. This is consistent with how extractant and diluent molecular structure are known to impact metal and acid loading capacity in many-component LLE organic phases, suggesting phase behavior of practical systems may be effectively studied in simplified organic phases. Overall, the explicit connection between molecular structure, aggregation and phase behavior demonstrated here will enable the design of more efficient separations processes.

4.
Phys Rev Lett ; 127(5): 058001, 2021 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-34397240

RESUMO

We report observations of nanosecond nonuniform colloidal dynamics in a free flowing liquid jet using ultrafast x-ray speckle visibility spectroscopy. Utilizing a nanosecond double-bunch mode, the Linac Coherent Light Source free electron laser produced pairs of femtosecond coherent hard x-ray pulses. By exploring anisotropy in the visibility of summed speckle patterns which relates to the correlation functions, we evaluate not only the average particle flow rate in a colloidal nanoparticle jet, but also the nonuniform flow field within. The methodology presented here establishes the foundation for the study of nano- and atomic-scale inhomogeneous fluctuations in complex matter using x-ray free electron laser sources.

5.
Nano Lett ; 18(2): 811-819, 2018 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-29345956

RESUMO

III-As nanowires are candidates for near-infrared light emitters and detectors that can be directly integrated onto silicon. However, nanoscale to microscale variations in structure, composition, and strain within a given nanowire, as well as variations between nanowires, pose challenges to correlating microstructure with device performance. In this work, we utilize coherent nanofocused X-rays to characterize stacking defects and strain in a single InGaAs nanowire supported on Si. By reconstructing diffraction patterns from the 21̅1̅0 Bragg peak, we show that the lattice orientation varies along the length of the wire, while the strain field along the cross-section is largely unaffected, leaving the band structure unperturbed. Diffraction patterns from the 011̅0 Bragg peak are reproducibly reconstructed to create three-dimensional images of stacking defects and associated lattice strains, revealing sharp planar boundaries between different crystal phases of wurtzite (WZ) structure that contribute to charge carrier scattering. Phase retrieval is made possible by developing multiangle Bragg projection ptychography (maBPP) to accommodate coherent nanodiffraction patterns measured at arbitrary overlapping positions at multiple angles about a Bragg peak, eliminating the need for scan registration at different angles. The penetrating nature of X-ray radiation, together with the relaxed constraints of maBPP, will enable the in operando imaging of nanowire devices.

6.
J Synchrotron Radiat ; 25(Pt 4): 1036-1047, 2018 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-29979165

RESUMO

In anticipation of the increased use of coherent X-ray methods and the need to upgrade beamlines to match improved source quality, here the coherence properties of the X-rays delivered by beamline 12ID-D at the Advanced Photon Source have been characterized. The measured X-ray divergence, beam size, brightness and coherent flux at energies up to 26 keV are compared with the calculated values from the undulator source, and the effects of beamline optics such as a mirror, monochromator and compound refractive lenses are evaluated. Diffraction patterns from slits as a function of slit width are analyzed using wave propagation theory to obtain the beam divergence and thus coherence length. Imaging of the source using a compound refractive lens was found to be the most accurate method for determining the vertical divergence. While the brightness and coherent flux obtained without a monochromator (`pink beam') agree well with those calculated for the source, those measured with the monochromator were a factor of three to six lower than the source, primarily because of vertical divergence introduced by the monochromator. The methods described herein should be widely applicable for measuring the X-ray coherence properties of synchrotron beamlines.

7.
J Chem Phys ; 146(14): 144702, 2017 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-28411601

RESUMO

The surface orientation can have profound effects on the atomic-scale processes of crystal growth and is essential to such technologies as GaN-based light-emitting diodes and high-power electronics. We investigate the dependence of homoepitaxial growth mechanisms on the surface orientation of a hexagonal crystal using kinetic Monte Carlo simulations. To model GaN metal-organic vapor phase epitaxy, in which N species are supplied in excess, only Ga atoms on a hexagonal close-packed (HCP) lattice are considered. The results are thus potentially applicable to any HCP material. Growth behaviors on c-plane (0001) and m-plane (011¯0) surfaces are compared. We present a reciprocal space analysis of the surface morphology, which allows extraction of growth mode boundaries and direct comparison with surface X-ray diffraction experiments. For each orientation, we map the boundaries between 3-dimensional, layer-by-layer, and step flow growth modes as a function of temperature and growth rate. Two models for surface diffusion are used, which produce different effective Ehrlich-Schwoebel step-edge barriers and different adatom diffusion anisotropies on m-plane surfaces. Simulation results in agreement with observed GaN island morphologies and growth mode boundaries are obtained. These indicate that anisotropy of step edge energy, rather than adatom diffusion, is responsible for the elongated islands observed on m-plane surfaces. Island nucleation spacing obeys a power-law dependence on growth rate, with exponents of -0.24 and -0.29 for the m- and c-plane, respectively.

8.
J Synchrotron Radiat ; 19(Pt 6): 1056-60, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23093770

RESUMO

The Hard X-ray Nanoprobe Beamline (or Nanoprobe Beamline) is an X-ray microscopy facility incorporating diffraction, fluorescence and full-field imaging capabilities designed and operated by the Center for Nanoscale Materials and the Advanced Photon Source at Sector 26 of the Advanced Photon Source at Argonne National Laboratory. This facility was constructed to probe the nanoscale structure of biological, environmental and material sciences samples. The beamline provides intense focused X-rays to the Hard X-ray Nanoprobe (or Nanoprobe) which incorporates Fresnel zone plate optics and a precision laser sensing and control system. The beamline operates over X-ray energies from 3 to 30 keV, enabling studies of most elements in the periodic table, with a particular emphasis on imaging transition metals.

9.
Phys Rev Lett ; 108(8): 087601, 2012 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-22463572

RESUMO

We show that light drives large-amplitude structural changes in thin films of the prototypical ferroelectric PbTiO3 via direct coupling to its intrinsic photovoltaic response. Using time-resolved x-ray scattering to visualize atomic displacements on femtosecond time scales, photoinduced changes in the unit-cell tetragonality are observed. These are driven by the motion of photogenerated free charges within the ferroelectric and can be simply explained by a model including both shift and screening currents, associated with the displacement of electrons first antiparallel to and then parallel to the ferroelectric polarization direction.

10.
J Chem Phys ; 137(5): 054708, 2012 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-22894372

RESUMO

Reaction pathways for complete decomposition of ammonia on the InN (0001) surface are investigated using first principles calculations. We show that while the initial NH(3) decomposition on this surface can proceed by H dissociation, its further decomposition is most favorable by H transfer. The calculated low diffusion barriers for the decomposed species on the surface imply that the metal-organic chemical vapor deposition growth of InN is a reaction-limited process rather than diffusion-limited at low adsorbate coverage.

11.
Opt Express ; 19(16): 15069-76, 2011 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-21934868

RESUMO

Hard x-ray microscopy with nanometer resolution will open frontiers in the study of materials and devices, environmental sciences, and life sciences by utilizing the unique characterization capabilities of x-rays. Here we report two-dimensional nanofocusing by multilayer Laue lenses (MLLs), a type of diffractive optics that is in principle capable of focusing x-rays to 1 nm. We demonstrate focusing to a 25 × 27 nm(2) FWHM spot with an efficiency of 2% at a photon energy of 12 keV, and to a 25 × 40 nm(2) FWHM spot with an efficiency of 17% at a photon energy of 19.5 keV.


Assuntos
Microscopia/métodos , Nanotecnologia/métodos , Animais , Desenho de Equipamento , Humanos , Lentes , Microscopia Eletrônica de Varredura/métodos , Microscopia de Fluorescência/métodos , Óptica e Fotônica/métodos , Fótons , Raios X
12.
Rev Sci Instrum ; 92(2): 023908, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33648142

RESUMO

Solid-phase epitaxy (SPE) and other three-dimensional epitaxial crystallization processes pose challenging structural and chemical characterization problems. The concentration of defects, the spatial distribution of elastic strain, and the chemical state of ions each vary with nanoscale characteristic length scales and depend sensitively on the gas environment and elastic boundary conditions during growth. The lateral or three-dimensional propagation of crystalline interfaces in SPE has nanoscale or submicrometer characteristic distances during typical crystallization times. An in situ synchrotron hard x-ray instrument allows these features to be studied during deposition and crystallization using diffraction, resonant scattering, nanobeam and coherent diffraction imaging, and reflectivity. The instrument incorporates a compact deposition system allowing the use of short-working-distance x-ray focusing optics. Layers are deposited using radio-frequency magnetron sputtering and evaporation sources. The deposition system provides control of the gas atmosphere and sample temperature. The sample is positioned using a stable mechanical design to minimize vibration and drift and employs precise translation stages to enable nanobeam experiments. Results of in situ x-ray characterization of the amorphous thin film deposition process for a SrTiO3/BaTiO3 multilayer illustrate implementation of this instrument.

13.
Nat Commun ; 12(1): 1721, 2021 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-33741925

RESUMO

The stacking sequence of hexagonal close-packed and related crystals typically results in steps on vicinal {0001} surfaces that have alternating A and B structures with different growth kinetics. However, because it is difficult to experimentally identify which step has the A or B structure, it has not been possible to determine which has faster adatom attachment kinetics. Here we show that in situ microbeam surface X-ray scattering can determine whether A or B steps have faster kinetics under specific growth conditions. We demonstrate this for organo-metallic vapor phase epitaxy of (0001) GaN. X-ray measurements performed during growth find that the average width of terraces above A steps increases with growth rate, indicating that attachment rate constants are higher for A steps, in contrast to most predictions. Our results have direct implications for understanding the atomic-scale mechanisms of GaN growth and can be applied to a wide variety of related crystals.

14.
Phys Rev Lett ; 105(16): 167601, 2010 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-21231014

RESUMO

Polarization switching in ferroelectrics has been thought to occur only through the nucleation and growth of new domains. Here we use in situ synchrotron x-ray scattering to monitor switching controlled by applied chemical potential. In sufficiently thin PbTiO3 films, nucleation is suppressed and switching occurs by a continuous mechanism, i.e., by uniform decrease and inversion of the polarization without domain formation. The observed lattice parameter shows that the electric field in the film during switching reaches the theoretical intrinsic coercive field.

15.
Sci Rep ; 10(1): 5054, 2020 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-32193442

RESUMO

The ability to deliver two coherent X-ray pulses with precise time-delays ranging from a few femtoseconds to nanoseconds enables critical capabilities of probing ultra-fast phenomena in condensed matter systems at X-ray free electron laser (FEL) sources. Recent progress made in the hard X-ray split-and-delay optics developments now brings a very promising prospect for resolving atomic-scale motions that were not accessible by previous time-resolved techniques. Here, we report on characterizing the spatial and temporal coherence properties of the hard X-ray FEL beam after propagating through split-and-delay optics. Speckle contrast analysis of small-angle scattering measurements from nanoparticles reveals well-preserved transverse coherence of the beam. Measuring intensity fluctuations from successive X-ray pulses also reveals that only single or double temporal modes remain in the transmitted beam, corresponding to nearly Fourier transform limited pulses.

16.
Rev Sci Instrum ; 79(5): 053104, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18513058

RESUMO

A multilayer Laue lens (MLL) is an x-ray focusing optic fabricated from a multilayer structure consisting of thousands of layers of two different materials produced by thin-film deposition. The sequence of layer thicknesses is controlled to satisfy the Fresnel zone plate law and the multilayer is sectioned to form the optic. An improved MLL geometry can be created by growing each layer with an in-plane thickness gradient to form a wedge, so that every interface makes the correct angle with the incident beam for symmetric Bragg diffraction. The ultimate hard x-ray focusing performance of a wedged MLL has been predicted to be significantly better than that of a nonwedged MLL, giving subnanometer resolution with high efficiency. Here, we describe a method to deposit the multilayer structure needed for an ideal wedged MLL and report our initial deposition results to produce these structures.

17.
Rev Sci Instrum ; 78(4): 046103, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17477694

RESUMO

We report a process to fabricate multilayer Laue lenses (MLL's) by sectioning and thinning multilayer films. This method can produce a linear zone plate structure with a very large ratio of zone depth to width (e.g., >1000), orders of magnitude larger than can be attained with photolithography. Consequently, MLL's are advantageous for efficient nanofocusing of hard x rays. MLL structures prepared by the technique reported here have been tested at an x-ray energy of 19.5 keV, and a diffraction-limited performance was observed. The present article reports the fabrication techniques that were used to make the MLL's.

18.
Science ; 356(6339): 739-742, 2017 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-28522531

RESUMO

Polycrystalline material properties depend on the distribution and interactions of their crystalline grains. In particular, grain boundaries and defects are crucial in determining their response to external stimuli. A long-standing challenge is thus to observe individual grains, defects, and strain dynamics inside functional materials. Here we report a technique capable of revealing grain heterogeneity, including strain fields and individual dislocations, that can be used under operando conditions in reactive environments: grain Bragg coherent diffractive imaging (gBCDI). Using a polycrystalline gold thin film subjected to heating, we show how gBCDI resolves grain boundary and dislocation dynamics in individual grains in three-dimensional detail with 10-nanometer spatial and subangstrom displacement field resolution. These results pave the way for understanding polycrystalline material response under external stimuli and, ideally, engineering particular functions.

19.
Rev Sci Instrum ; 88(3): 035113, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28372371

RESUMO

We describe an instrument that exploits the ongoing revolution in synchrotron sources, optics, and detectors to enable in situ studies of metal-organic vapor phase epitaxy (MOVPE) growth of III-nitride materials using coherent x-ray methods. The system includes high-resolution positioning of the sample and detector including full rotations, an x-ray transparent chamber wall for incident and diffracted beam access over a wide angular range, and minimal thermal sample motion, giving the sub-micron positional stability and reproducibility needed for coherent x-ray studies. The instrument enables surface x-ray photon correlation spectroscopy, microbeam diffraction, and coherent diffraction imaging of atomic-scale surface and film structure and dynamics during growth, to provide fundamental understanding of MOVPE processes.

20.
Nat Mater ; 8(9): 702-3, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19701213
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA