Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 494
Filtrar
1.
Am J Physiol Cell Physiol ; 326(3): C917-C934, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38284123

RESUMO

The tissue inhibitors of matrix metalloproteinases (TIMPs) are a family of four matrisome proteins classically defined by their roles as the primary endogenous inhibitors of metalloproteinases (MPs). Their functions however are not limited to MP inhibition, with each family member harboring numerous MP-independent biological functions that play key roles in processes such as inflammation and apoptosis. Because of these multifaceted functions, TIMPs have been cited in diverse pathophysiological contexts. Herein, we provide a comprehensive overview of the MP-dependent and -independent roles of TIMPs across a range of pathological conditions. The potential therapeutic and biomarker applications of TIMPs in these disease contexts are also considered, highlighting the biomedical promise of this complex and often misunderstood protein family.


Assuntos
Metaloproteinases da Matriz , Inibidores Teciduais de Metaloproteinases , Inibidores Teciduais de Metaloproteinases/metabolismo , Metaloproteinases da Matriz/metabolismo , Matriz Extracelular/metabolismo
2.
Am Heart J ; 274: 1-10, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38649085

RESUMO

BACKGROUND: Recurrent ventricular tachycardia (VT) in patients with prior myocardial infarction is associated with adverse quality of life and clinical outcomes, despite the presence of implanted defibrillators (ICDs). Suppression of recurrent VT can be accomplished with antiarrhythmic drug therapy or catheter ablation. The Ventricular Tachycardia Antiarrhythmics or Ablation In Structural Heart Disease 2 (VANISH2) trial is designed to determine whether ablation is superior to antiarrhythmic drug therapy as first line therapy for patients with ischemic cardiomyopathy and VT. METHODS: The VANISH2 trial enrolls patients with prior myocardial infarction and VT (with one of: ≥1 ICD shock; ≥3 episodes treated with antitachycardia pacing (ATP) and symptoms; ≥5 episodes treated with ATP regardless of symptoms; ≥3 episodes within 24 hours; or sustained VT treated with electrical cardioversion or pharmacologic conversion). Enrolled patients are classified as either sotalol-eligible, or amiodarone-eligible, and then are randomized to either catheter ablation or to that antiarrhythmic drug therapy, with randomization stratified by drug-eligibility group. Drug therapy, catheter ablation procedures and ICD programming are standardized. All patients will be followed until two years after randomization. The primary endpoint is a composite of mortality at any time, appropriate ICD shock after 14 days, VT storm after 14 days, and treated sustained VT below detection of the ICD after 14 days. The outcomes will be analyzed according to the intention-to-treat principle using survival analysis techniques RESULTS: The results of the VANISH2 trial are intended to provide data to support clinical decisions on how to suppress VT for patients with prior myocardial infarction. CLINICALTRIALS: gov registration NCT02830360.


Assuntos
Antiarrítmicos , Cardiomiopatias , Ablação por Cateter , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/terapia , Antiarrítmicos/uso terapêutico , Ablação por Cateter/métodos , Cardiomiopatias/complicações , Cardiomiopatias/terapia , Isquemia Miocárdica/complicações , Masculino , Feminino , Desfibriladores Implantáveis , Pessoa de Meia-Idade , Amiodarona/uso terapêutico , Resultado do Tratamento , Sotalol/uso terapêutico , Terapia Combinada
3.
Am J Pathol ; 193(10): 1336-1352, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37572947

RESUMO

Tissue inhibitors of metalloproteinases (TIMPs) are a conserved family of proteins that were originally identified as cytokine-like erythroid growth factors. Subsequently, TIMPs were characterized as endogenous inhibitors of matrixin proteinases. These proteinases are the primary mediators of extracellular matrix turnover in pathologic conditions, such as cancer invasion and metastasis. Thus, TIMPs were immediately recognized as important regulators of tissue homeostasis. However, TIMPs also demonstrate unique biological activities that are independent of metalloproteinase regulation. Although often overlooked, these non-protease-mediated TIMP functions demonstrate a variety of direct cellular effects of potential therapeutic value. TIMP2 is the most abundantly expressed TIMP family member, and ongoing studies show that its tumor suppressor activity extends beyond protease inhibition to include direct modulation of tumor, endothelial, and fibroblast cellular responses in the tumor microenvironment. Recent data suggest that TIMP2 can suppress both primary tumor growth and metastatic niche formation. TIMP2 directly interacts with cellular receptors and matrisome elements to modulate cell signaling pathways that result in reduced proliferation and migration of neoplastic, endothelial, and fibroblast cell populations. These effects result in enhanced cell adhesion and focal contact formation while reducing tumor and endothelial proliferation, migration, and epithelial-to-mesenchymal transitions. These findings are consistent with TIMP2 homeostatic functions beyond simple inhibition of metalloprotease activity. This review examines the ongoing evolution of TIMP2 function, future perspectives in TIMP research, and the therapeutic potential of TIMP2.


Assuntos
Neoplasias , Inibidor Tecidual de Metaloproteinase-2 , Humanos , Inibidor Tecidual de Metaloproteinase-2/metabolismo , Neoplasias/metabolismo , Inibidor Tecidual de Metaloproteinase-1/metabolismo , Proteólise , Homeostase , Peptídeo Hidrolases/metabolismo , Inibidores Teciduais de Metaloproteinases/metabolismo , Inibidor Tecidual de Metaloproteinase-3/metabolismo , Microambiente Tumoral
4.
J Cardiovasc Electrophysiol ; 35(5): 994-1004, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38501333

RESUMO

INTRODUCTION: When ventricular tachycardia (VT) recurs after standard RF ablation (sRFA) some patients benefit from repeat sRFA, whereas others warrant advanced methods such as intramural needle ablation (INA). Our objectives are to assess the utility of repeat sRFA and to clarify the benefit of INA when repeat sRFA fails in patients with VT due to structural heart disease. METHODS: In consecutive patients who were prospectively enrolled in a study for INA for recurrent sustained monomorphic VT despite sRFA, repeat sRFA was considered first. INA was performed during the same procedure if repeat sRFA failed or no targets for sRFA were identified. RESULTS: Of 85 patients enrolled, acute success with repeat sRFA was achieved in 30 patients (35%), and during the 6-month follow-up, 87% (20/23) were free of VT hospitalization, 78% were free of any VT, and 7 were lost to follow-up. INA was performed in 55 patients (65%) after sRFA failed, or no endocardial targets were found abolished or modified inducible VT in 35/55 patients (64%). During follow-up, 72% (39/54) were free of VT hospitalization, 41% were free of any VT, and 1 was lost to follow-up. Overall, 59 out of 77 (77%) patients were free of hospitalization and 52% were free of any VT. Septal-origin VTs were more likely to need INA, whereas RV and papillary muscle VTs were less likely to require INA. CONCLUSIONS: Repeat sRFA was beneficial in 23% (18/77) of patients with recurrent sustained VT who were referred for INA. The availability of INA increased favorable outcomes to 52%.


Assuntos
Ablação por Cateter , Cicatriz , Recidiva , Reoperação , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Ablação por Cateter/efeitos adversos , Cicatriz/fisiopatologia , Cicatriz/diagnóstico , Cicatriz/cirurgia , Cicatriz/etiologia , Fatores de Tempo , Potenciais de Ação , Agulhas , Frequência Cardíaca , Fatores de Risco , Resultado do Tratamento
5.
Circ Res ; 130(11): 1698-1722, 2022 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-35617362

RESUMO

There is increasing evidence regarding the prevalence of genetic cardiomyopathies, for which arrhythmias may be the first presentation. Ventricular and atrial arrhythmias presenting in the absence of known myocardial disease are often labelled as idiopathic, or lone. While ventricular arrhythmias are well-recognized as presentation for arrhythmogenic cardiomyopathy in the right ventricle, the scope of arrhythmogenic cardiomyopathy has broadened to include those with dominant left ventricular involvement, usually with a phenotype of dilated cardiomyopathy. In addition, careful evaluation for genetic cardiomyopathy is also warranted for patients presenting with frequent premature ventricular contractions, conduction system disease, and early onset atrial fibrillation, in which most detected genes are in the cardiomyopathy panels. Sudden death can occur early in the course of these genetic cardiomyopathies, for which risk is not adequately tracked by left ventricular ejection fraction. Only a few of the cardiomyopathy genotypes implicated in early sudden death are recognized in current indications for implantable cardioverter defibrillators which otherwise rely upon a left ventricular ejection fraction ≤0.35 in dilated cardiomyopathy. The genetic diagnoses impact other aspects of clinical management such as exercise prescription and pharmacological therapy of arrhythmias, and new therapies are coming into clinical investigation for specific genetic cardiomyopathies. The expansion of available genetic information and implications raises new challenges for genetic counseling, particularly with the family member who has no evidence of a cardiomyopathy phenotype and may face a potentially negative impact of a genetic diagnosis. Discussions of risk for both probands and relatives need to be tailored to their numeric literacy during shared decision-making. For patients presenting with arrhythmias or cardiomyopathy, extension of genetic testing and its implications will enable cascade screening, intervention to change the trajectory for specific genotype-phenotype profiles, and enable further development and evaluation of emerging targeted therapies.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Cardiomiopatia Dilatada , Cardiomiopatias/diagnóstico , Cardiomiopatias/genética , Cardiomiopatias/terapia , Cardiomiopatia Dilatada/diagnóstico , Cardiomiopatia Dilatada/genética , Cardiomiopatia Dilatada/terapia , Morte Súbita , Morte Súbita Cardíaca/prevenção & controle , Humanos , Volume Sistólico , Função Ventricular Esquerda
6.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38367008

RESUMO

AIMS: Failure of radiofrequency (RF) ablation of ventricular arrhythmias is often due to inadequate lesion size. Irrigated RF ablation with half-normal saline (HNS) has the potential to increase lesion size and reduce sodium delivery to the patient if the same volume of RF irrigant were used for normal saline (NS) and HNS but could increase risks related to steam pops and lesion size. This study aims to assess periprocedural complications and acute ablation outcome of ventricular arrhythmias ablation with HNS. METHODS AND RESULTS: Prospective assessment of outcomes was performed in 1024 endocardial and/or epicardial RF ablation procedures in 935 consecutive patients (median age 64 years, 71.2% men, 73.4% cardiomyopathy, 47.2% sustained ventricular tachycardia). Half-normal saline was selected at the discretion of the treating physician. Radiofrequency ablation power was generally titrated to a ≤15â€…Ω impedance fall with intracardiac echocardiography monitoring. Half-normal saline was used in 900 (87.9%) and NS in 124 (12.1%) procedures. Any adverse event within 30 days occurred in 13.0% of patients treated with HNS RF ablation including 4 (0.4%) strokes/transient ischaemic attacks and 34 (3.8%) pericardial effusions requiring treatment (mostly related to epicardial access). Two steam pops with perforation required surgical repair (0.2%). Patients who received NS irrigation had less severe disease and arrhythmias. In multivariable models, adverse events and acute success of the procedure were not related to the type of irrigation. CONCLUSION: Half-normal saline irrigation RF ablation with power guided by impedance fall and intracardiac echocardiography has an acceptable rate of complications and acute ablation success while administering half of the saline load expected for NS irrigation.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Taquicardia Ventricular , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Solução Salina/efeitos adversos , Vapor , Estudos Prospectivos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Taquicardia Ventricular/cirurgia , Irrigação Terapêutica/efeitos adversos
7.
J Cardiovasc Electrophysiol ; 34(11): 2403-2405, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37787011

RESUMO

INTRODUCTION: Intracardiac echocardiography (ICE) reveals mobile thrombus on implantable electronic device leads in some patients undergoing electrophysiologic procedures. METHODS: ICE was performed in a patient undergoing ventricular tachycardia (VT) ablation. RESULTS: ICE showed extensive mobile thrombi on the implantable cardioverter defibrillator lead. Radiofrequency catheter ablation of VT from perimitral scar was safely performed via a retrograde aortic approach. After the procedure, chronic anticoagulation was initiated. CT-angiography of the chest 2 months later showed no pulmonary emboli. CONCLUSIONS: The significance of these thrombi, as related to chronic pulmonary embolization, warrants further study.


Assuntos
Ablação por Cateter , Cardiopatias , Taquicardia Ventricular , Trombose , Humanos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Vento , Cardiopatias/cirurgia , Trombose/diagnóstico por imagem , Trombose/etiologia , Ablação por Cateter/métodos , Cabelo , Resultado do Tratamento
8.
Carcinogenesis ; 43(5): 405-418, 2022 06 04.
Artigo em Inglês | MEDLINE | ID: mdl-35436325

RESUMO

Tissue inhibitors of metalloproteinases (TIMPs) are a conserved family of proteins that were originally identified as endogenous inhibitors of matrixin and adamalysin endopeptidase activity. The matrixins and adamalysins are the major mediators of extracellular matrix (ECM) turnover, thus making TIMPs important regulators of ECM structure and composition. Despite their high sequence identity and relative redundancy in inhibitory profiles, each TIMP possesses unique biological characteristics that are independent of their regulation of metalloproteinase activity. As our understanding of TIMP biology has evolved, distinct roles have been assigned to individual TIMPs in cancer progression. In this respect, data regarding TIMP2's role in cancer have borne conflicting reports of both tumor suppressor and, to a lesser extent, tumor promoter functions. TIMP2 is the most abundant TIMP family member, prevalent in normal and diseased mammalian tissues as a constitutively expressed protein. Despite its apparent stable expression, recent work highlights how TIMP2 is a cell stress-induced gene product and that its biological activity can be dictated by extracellular posttranslational modifications. Hence an understanding of TIMP2 molecular targets, and how its biological functions evolve in the progressing tumor microenvironment may reveal new therapeutic opportunities. In this review, we discuss the continually evolving functions of TIMP proteins, future perspectives in TIMP research, and the therapeutic utility of this family, with a particular focus on TIMP2.


Assuntos
Neoplasias , Inibidores Teciduais de Metaloproteinases , Animais , Matriz Extracelular/metabolismo , Mamíferos , Neoplasias/tratamento farmacológico , Neoplasias/genética , Neoplasias/metabolismo , Proteólise , Inibidores Teciduais de Metaloproteinases/genética , Microambiente Tumoral/genética
9.
Magn Reson Med ; 87(6): 2885-2900, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35142398

RESUMO

PURPOSE: Develop a deflectable intracardiac MR imaging (ICMRI) guiding-sheath to accelerate imaging during MR-guided electrophysiological (EP) interventions for radiofrequency (500 kHz) ablation (RFA) of arrythmia. Requirements include imaging at three to five times surface-coil SNR in cardiac chambers, vascular insertion, steerable-active-navigation into cardiac chambers, operation with ablation catheters, and safe levels of MR-induced heating. METHODS: ICMRI's 6 mm outer-diameter (OD) metallic-braided shaft had a 2.6 mm OD internal lumen for ablation-catheter insertion. Miniature-Baluns (MBaluns) on ICMRI's 1 m shaft reduced body-coil-induced heating. Distal section was a folded "star"-shaped imaging-coil mounted on an expandable frame, with an integrated miniature low-noise-amplifier overcoming cable losses. A handle-activated movable-shaft expanded imaging-coil to 35 mm OD for imaging within cardiac-chambers. Four MR-tracking micro-coils enabled navigation and motion-compensation, assuming a tetrahedron-shape when expanded. A second handle-lever enabled distal-tip deflection. ICMRI with a protruding deflectable EP catheter were used for MR-tracked navigation and RFA using a dedicated 3D-slicer user-interface. ICMRI was tested at 3T and 1.5T in swine to evaluate (a) heating, (b) cardiac-chamber access, (c) imaging field-of-view and SNR, and (d) intraprocedural RFA lesion monitoring. RESULTS: The 3T and 1.5T imaging SNR demonstrated >400% SNR boost over a 4 × 4 × 4 cm3 FOV in the heart, relative to body and spine arrays. ICMRI with MBaluns met ASTM/IEC heating limits during navigation. Tip-deflection allowed navigating ICMRI and EP catheter into atria and ventricles. Acute-lesion long-inversion-time-T1-weighted 3D-imaging (TWILITE) ablation-monitoring using ICMRI required 5:30 min, half the time needed with surface arrays alone. CONCLUSION: ICMRI assisted EP-catheter navigation to difficult targets and accelerated RFA monitoring.


Assuntos
Ablação por Cateter , Imageamento por Ressonância Magnética , Animais , Arritmias Cardíacas , Ablação por Cateter/métodos , Desenho de Equipamento , Átrios do Coração , Imageamento por Ressonância Magnética/métodos , Suínos
10.
Am J Pathol ; 191(12): 2219-2230, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34428424

RESUMO

Transdifferentiation (or activation) of hepatic stellate cells (HSCs) to myofibroblasts is a key event in liver fibrosis. Activated HSCs in the tumor microenvironment reportedly promote tumor progression. This study analyzed the effect of an inhibitor of HSC activation, retinol-binding protein-albumin domain III fusion protein (R-III), on protumorigenic functions of HSCs. Although conditioned medium collected from activated HSCs enhanced the migration, invasion, and proliferation of the hepatocellular carcinoma cell line Hepa-1c1c7, this effect was not observed in Hepa-1c1c7 cells treated with conditioned medium from R-III-exposed HSCs. In a subcutaneous tumor model, larger tumors with increased vascular density were formed in mice transplanted with Hepa-1c1c7+HSC than in mice transplanted with Hepa-1c1c7 cells alone. Intriguingly, when Hepa-1c1c7+HSC-transplanted mice were injected intravenously with R-III, a reduction in vascular density and extended tumor necrosis were observed. In an orthotopic tumor model, co-transplantation of HSCs enhanced tumor growth, angiogenesis, and regional metastasis accompanied by increased peritumoral lymphatic vessel density, which was abolished by R-III. In vitro study showed that R-III treatment affected the synthesis of pro-angiogenic and anti-angiogenic factors in activated HSCs, which might be the potential mechanism underlying the R-III effect. These findings suggest that the inhibition of HSC activation abrogates HSC-induced tumor angiogenesis and growth, which represents an attractive therapeutic strategy.


Assuntos
Carcinoma Hepatocelular/patologia , Células Estreladas do Fígado/efeitos dos fármacos , Neoplasias Hepáticas/patologia , Proteínas Recombinantes de Fusão/farmacologia , Albuminas/química , Albuminas/farmacologia , Albuminas/uso terapêutico , Animais , Antineoplásicos/farmacologia , Antineoplásicos/uso terapêutico , Carcinoma Hepatocelular/irrigação sanguínea , Carcinoma Hepatocelular/terapia , Transformação Celular Neoplásica/efeitos dos fármacos , Células Cultivadas , Regulação para Baixo/efeitos dos fármacos , Feminino , Células Estreladas do Fígado/fisiologia , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/terapia , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Neovascularização Patológica/genética , Neovascularização Patológica/prevenção & controle , Domínios e Motivos de Interação entre Proteínas/fisiologia , Proteínas Recombinantes de Fusão/uso terapêutico , Proteínas de Ligação ao Retinol/farmacologia , Proteínas de Ligação ao Retinol/uso terapêutico , Microambiente Tumoral/efeitos dos fármacos , Ensaios Antitumorais Modelo de Xenoenxerto
11.
Europace ; 24(4): 598-605, 2022 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-34791165

RESUMO

AIM: To describe clinical characteristics, procedural details, specific challenges, and outcomes in patients with HeartMate3™ (HM3), a left ventricular assist device system with a magnetically levitated pump, undergoing ventricular tachycardia ablation (VTA). METHODS AND RESULTS: Data were collected from patients with an HM3 system who underwent VTA in seven tertiary centres. Data included baseline patient characteristics, procedural data, mortality, and arrhythmia-free survival. The study cohort included 19 patients with cardiomyopathy presenting with ventricular tachycardia (VT) (53% with VT storm). Ventricular tachycardias were induced in 89% of patients and a total of 41 VTs were observed. Severe electromagnetic interference was present on the surface electrocardiogram. Hence, VT localization required analysis of intra-cardiac signals or the use of filter in the 40-20 Hz range. The large house pump HM3 design obscured the cannula inflow and therefore multi imaging modalities were necessary to avoid catheter entrapment in the cannula. A total of 32 VTs were mapped and were successfully ablated (31% to the anterior wall, 38% to the septum and only 9% to the inflow cannula region). Non-inducibility of any VT was reached in 11 patients (58%). Over a follow-up of 429 (interquartile range 101-692) days, 5 (26%) patients underwent a redo VT ablation due to recurrent VTA and 2 (11%) patients died. CONCLUSIONS: Ventricular tachycardia ablation in patients with HM3 is feasible and safe when done in the appropriate setup. Long-term arrhythmia-free survival is acceptable but not well predicted by non-inducibility at the end of the procedure.


Assuntos
Cardiomiopatias , Ablação por Cateter , Coração Auxiliar , Taquicardia Ventricular , Cardiomiopatias/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Recidiva , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
12.
Mol Cell ; 53(2): 317-29, 2014 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-24462205

RESUMO

The stability and activity of numerous signaling proteins in both normal and cancer cells depends on the dimeric molecular chaperone heat shock protein 90 (Hsp90). Hsp90's function is coupled to ATP binding and hydrolysis and requires a series of conformational changes that are regulated by cochaperones and numerous posttranslational modifications (PTMs). SUMOylation is one of the least-understood Hsp90 PTMs. Here, we show that asymmetric SUMOylation of a conserved lysine residue in the N domain of both yeast (K178) and human (K191) Hsp90 facilitates both recruitment of the adenosine triphosphatase (ATPase)-activating cochaperone Aha1 and, unexpectedly, the binding of Hsp90 inhibitors, suggesting that these drugs associate preferentially with Hsp90 proteins that are actively engaged in the chaperone cycle. Importantly, cellular transformation is accompanied by elevated steady-state N domain SUMOylation, and increased Hsp90 SUMOylation sensitizes yeast and mammalian cells to Hsp90 inhibitors, providing a mechanism to explain the sensitivity of cancer cells to these drugs.


Assuntos
Trifosfato de Adenosina/metabolismo , Chaperoninas/metabolismo , Proteínas de Choque Térmico HSP90/metabolismo , Proteínas de Saccharomyces cerevisiae/metabolismo , Saccharomyces cerevisiae/metabolismo , Proteínas de Choque Térmico HSP90/química , Proteínas de Choque Térmico HSP90/fisiologia , Humanos , Estrutura Terciária de Proteína , Sumoilação
13.
J Cardiovasc Electrophysiol ; 32(2): 409-416, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33355965

RESUMO

INTRODUCTION: Patients with prior cardiac surgery may represent a subgroup of patients with ventricular tachycardia (VT) that may be more difficult to control with catheter ablation. METHODS: We evaluated 1901 patients with ischemic and nonischemic cardiomyopathy who underwent VT ablation at 12 centers. Clinical characteristics and VT radiofrequency ablation procedural outcomes were assessed and compared between those with and without prior cardiac surgery. Kaplan-Meier analysis was used to estimate freedom from recurrent VT and survival. RESULTS: There were 578 subjects (30.4%) with prior cardiac surgery identified in the cohort. Those with prior cardiac surgery were older (66.4 ± 11.0 years vs. 60.5 ± 13.9 years, p < .01), with lower left ventricular ejection fraction (30.2 ± 11.5% vs. 34.8 ± 13.6%, p < .01) and more ischemic heart disease (82.5% vs. 39.3%, p < .01) but less likely to undergo epicardial mapping or ablation (9.0% vs. 38.1%, p<.01) compared to those without prior surgery. When epicardial mapping was performed, a significantly greater proportion required surgical intervention for access (19/52 [36.5%] vs. 14/504 [2.8%]; p < .01). Procedural complications, including epicardial access-related complications, were lower (5.7% vs. 7.0%, p < .01) in patients with versus without prior cardiac surgery. VT-free survival (75.1% vs. 74.1%, p = .805) and survival (86.5% vs. 87.9%, p = .397) were not different between those with and without prior heart surgery, regardless of etiology of cardiomyopathy. VT recurrence was associated with increased mortality in patients with and without prior cardiac surgery. CONCLUSION: Despite different clinical characteristics and fewer epicardial procedures, the safety and efficacy of VT ablation in patients with prior cardiac surgery is similar to others in this cohort. The incremental yield of epicardial mapping in predominant ischemic cardiomyopathy population prior heart surgery may be low but appears safe in experienced centers.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ablação por Cateter , Taquicardia Ventricular , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ablação por Cateter/efeitos adversos , Humanos , Pericárdio/cirurgia , Recidiva , Volume Sistólico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento , Função Ventricular Esquerda
14.
Europace ; 23(9): 1338-1349, 2021 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-33864080

RESUMO

Ventricular arrhythmias (VAs) can originate from different anatomical locations of the right ventricle. Ventricular arrhythmias originating from right ventricle have unique electrocardiographic (ECG) characteristics that can be utilized to localize the origin of the arrhythmia. This is crucial in pre-procedural planning particularly for ablation treatments. Moreover, non-ischaemic structural heart diseases, such as infiltrative and congenital heart diseases, are associated with the VAs that exhibit particular ECG findings. This article comprehensively reviews discriminatory ECG characteristics of VAs in the right ventricle with and without structural right ventricular diseases.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Eletrocardiografia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia
15.
Biochemistry ; 59(32): 2922-2933, 2020 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-32702237

RESUMO

Matrix metalloprotease (MMP) activation contributes to the degradation of the extracellular matrix (ECM), resulting in a multitude of pathologies. Low-density lipoprotein receptor-related protein 1 (LRP1) is a multifaceted endocytic and signaling receptor that is responsible for internalization and lysosomal degradation of diverse proteases, protease inhibitors, and lipoproteins along with numerous other proteins. In this study, we identified MMP-1 as a novel LRP1 ligand. Binding studies employing surface plasmon resonance revealed that both proMMP-1 and active MMP-1 bind to purified LRP1 with equilibrium dissociation constants (KD) of 19 and 25 nM, respectively. We observed that human aortic smooth muscle cells readily internalize and degrade 125I-labeled proMMP-1 in an LRP1-mediated process. Our binding data also revealed that all tissue inhibitors of metalloproteases (TIMPs) bind to LRP1 with KD values ranging from 23 to 33 nM. Interestingly, the MMP-1/TIMP-1 complex bound to LRP1 with an affinity (KD = 0.6 nM) that was 30-fold higher than that of either component alone, revealing that LRP1 prefers the protease:inhibitor complex as a ligand. Of note, modification of lysine residues on either proMMP-1 or TIMP-1 ablated the ability of the MMP-1/TIMP-1 complex to bind to LRP1. LRP1's preferential binding to enzyme:inhibitor complexes was further supported by the higher binding affinity for proMMP-9/TIMP-1 complexes than for either of these two components alone. LRP1 has four clusters of ligand-binding repeats, and MMP-1, TIMP-1, and MMP-1/TIMP-1 complexes bound to cluster III most avidly. Our results reveal an important role for LRP1 in controlling ECM homeostasis by regulating MMP-1 and MMP-9 levels.


Assuntos
Proteína-1 Relacionada a Receptor de Lipoproteína de Baixa Densidade/metabolismo , Metaloproteinase 1 da Matriz/metabolismo , Inibidor Tecidual de Metaloproteinase-1/metabolismo , Animais , Aorta/citologia , Linhagem Celular , Endocitose , Ativação Enzimática , Regulação da Expressão Gênica , Humanos , Masculino , Camundongos , Miócitos de Músculo Liso/metabolismo , Ligação Proteica
16.
Carcinogenesis ; 41(3): 313-325, 2020 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-31621840

RESUMO

Metastasis is the primary cause of treatment failures and mortality in most cancers. Triple-negative breast cancer (TNBC) is refractory to treatment and rapidly progresses to disseminated disease. We utilized an orthotopic mouse model that molecularly and phenotypically resembles human TNBC to study the effects of exogenous, daily tissue inhibitor of metalloproteinase-2 (TIMP-2) treatment on tumor growth and metastasis. Our results demonstrated that TIMP-2 treatment maximally suppressed primary tumor growth by ~36-50% and pulmonary metastasis by >92%. Immunostaining assays confirmed disruption of the epithelial to mesenchymal transition (EMT) and promotion of vascular integrity in primary tumor tissues. Immunostaining and RNA sequencing analysis of lung tissue lysates from tumor-bearing mice identified significant changes associated with metastatic colony formation. Specifically, TIMP-2 treatment disrupts periostin localization and critical cell-signaling pathways, including canonical Wnt signaling involved in EMT, as well as PI3K signaling, which modulates proliferative and metastatic behavior through p27 phosphorylation/localization. In conclusion, our study provides evidence in support of a role for TIMP-2 in suppression of triple-negative breast cancer growth and metastasis through modulation of the epithelial to mesenchymal transition, vascular normalization, and signaling pathways associated with metastatic outgrowth. Our findings suggest that TIMP-2, a constituent of the extracellular matrix in normal tissues, may have both direct and systemic antitumor and metastasis suppressor effects, suggesting potential utility in the clinical management of breast cancer progression.


Assuntos
Carcinogênese/genética , Proliferação de Células/genética , Inibidor Tecidual de Metaloproteinase-2/genética , Neoplasias de Mama Triplo Negativas/genética , Animais , Linhagem Celular Tumoral , Movimento Celular/genética , Modelos Animais de Doenças , Transição Epitelial-Mesenquimal/genética , Feminino , Humanos , Metástase Neoplásica , Fosfatidilinositol 3-Quinases , Análise de Sequência de RNA , Neoplasias de Mama Triplo Negativas/patologia , Via de Sinalização Wnt/genética , Ensaios Antitumorais Modelo de Xenoenxerto
18.
Europace ; 22(8): 1216-1223, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32514579

RESUMO

AIMS: Cardiac amyloidosis (CA) is associated with increased mortality due to arrhythmias, heart failure, and electromechanical dissociation. However, the role of an implantable cardioverter-defibrillator (ICD) remains unclear. We conducted case-control study to assess survival in CA patients with and without a primary prevention ICD and compared outcomes to an age, sex, and device implant year-matched non-CA group with primary prevention ICD. METHODS AND RESULTS: There were 91 subjects with CA [mean age= 71.2 ± 10.2, female 22.0%, 49 AL with Mayo Stage 2.9 ± 1.0, 41 transthyretin amyloidosis (ATTR), 1 other] followed by Vanderbilt Amyloidosis centre. Patients with ICD (n = 23) were compared with those without (n = 68) and a non-amyloid group with ICD (n = 46). All subjects with ICD had implantation for primary prevention. Mean left ventricular ejection fraction was 36.2% ± 14.4% in CA with ICD, 41.0% ± 10.6% in CA without ICD, and 33.5% ± 14.4% in non-CA patients. Over 3.5 ± 3.1 years, 6 (26.1%) CA, and 12 (26.1%) non-CA subjects received ICD therapies (P = 0.71). Patients with CA had a significantly higher mortality (43.9% vs. 17.4%, P = 0.002) compared with the non-CA group. Mean time from device implantation to death was 21.8 months in AL and 22.8 months in ATTR patients. There was no significant difference in mortality between CA patients who did and did not receive an ICD (39.0% vs. 46.0%, P = 0.59). CONCLUSIONS: Despite comparable event rates patients with CA had a significantly higher mortality and ICDs were not associated with longer survival. With the emergence of effective therapy for AL amyloidosis, further study of ICD is needed in this group.


Assuntos
Amiloidose , Desfibriladores Implantáveis , Idoso , Idoso de 80 Anos ou mais , Amiloidose/diagnóstico , Amiloidose/terapia , Estudos de Casos e Controles , Morte Súbita Cardíaca , Feminino , Humanos , Pessoa de Meia-Idade , Fatores de Risco , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
19.
Europace ; 22(11): 1680-1687, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32830247

RESUMO

AIMS: Catheter ablation is an effective treatment for post-infarction ventricular tachycardia (VT). However, some patients may experience a worsened arrhythmia phenotype after ablation. We aimed to determine the prevalence and prognostic impact of arrhythmia exacerbation (AE) after post-infarction VT ablation. METHODS AND RESULTS: A total of 1187 consecutive patients (93% men, median age 68 years, median ejection fraction 30%) who underwent post-infarction VT ablation at six centres were included. Arrhythmia exacerbation was defined as post-ablation VT storm or incessant VT in patients without prior similar events. During follow-up (median 717 days), 426 (36%) patients experienced VT recurrence. Events qualifying as AE occurred in 67 patients (6%). Median times to VT recurrence with and without AE were 238 [interquartile range (IQR) 35-640] days and 135 (IQR 22-521) days, respectively (P = 0.25). Almost half of the patients (46%) who experienced AE experienced it within 6 months of the index procedure. Patients with AE had had longer ablation times during the ablation procedures compared to the rest of the patients (median 42 vs. 34 min, P = 0.02). Among patients with VT recurrence, the risk of death or heart transplantation was significantly higher in patients with than without AE (hazard ratio 1.99, 95% CI 1.28-3.10; P = 0.002) after adjusting for age, gender, ejection fraction, cardiac resynchronization therapy, post-ablation non-inducibility, and post-ablation amiodarone use. CONCLUSION: Arrhythmia exacerbation after ablation of infarct-related VT is infrequent but is independently associated with an adverse long-term outcome among patients who experience a VT recurrence. The mechanisms and mitigation strategies of AE after catheter ablation require further investigation.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Idoso , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Infarto , Masculino , Prevalência , Prognóstico , Recidiva , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/etiologia , Resultado do Tratamento
20.
Europace ; 22(3): 450-495, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31995197

RESUMO

Ventricular arrhythmias are an important cause of morbidity and mortality and come in a variety of forms, from single premature ventricular complexes to sustained ventricular tachycardia and fibrillation. Rapid developments have taken place over the past decade in our understanding of these arrhythmias and in our ability to diagnose and treat them. The field of catheter ablation has progressed with the development of new methods and tools, and with the publication of large clinical trials. Therefore, global cardiac electrophysiology professional societies undertook to outline recommendations and best practices for these procedures in a document that will update and replace the 2009 EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias. An expert writing group, after reviewing and discussing the literature, including a systematic review and meta-analysis published in conjunction with this document, and drawing on their own experience, drafted and voted on recommendations and summarized current knowledge and practice in the field. Each recommendation is presented in knowledge byte format and is accompanied by supportive text and references. Further sections provide a practical synopsis of the various techniques and of the specific ventricular arrhythmia sites and substrates encountered in the electrophysiology lab. The purpose of this document is to help electrophysiologists around the world to appropriately select patients for catheter ablation, to perform procedures in a safe and efficacious manner, and to provide follow-up and adjunctive care in order to obtain the best possible outcomes for patients with ventricular arrhythmias.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Eletrofisiologia Cardíaca , Consenso , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA