Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 144
Filtrar
1.
Acta Oncol ; 59(11): 1357-1364, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32686979

RESUMO

PURPOSE: To assess the relationship between F-18-fluoro-ethyl-tyrosine positron emission tomography (FET-PET) parameters of relapsing oligodendroglioma and progression-free survival. MATERIAL AND METHODS: The relationship of clinical parameters, FET-PET parameters (SUVmax, TBRmax, BTV, time-activity curves) and progression-free survival was analyzed using univariate and multivariate analysis in 42 adult patients with relapsing oligodendroglioma. Kaplan-Meier analysis was used to assess survival. RESULTS: Patients who did not undergo surgical resection of their relapsing tumor had significantly lower PFS if the tumor exhibited an SUVmax above 3.40 than those with an SUVmax below 3.40 (13.1 ± 2.3 months vs. 47.3 ± 6.0 months, respectively, p < .001). Patients who underwent surgery had similar PFS as the aforementioned non-operated patients with low SUVmax (53.6 ± 6.7 months, p = .948). The same was true for TBRmax using a threshold of 3.03 (PFS 12.5 ± 2.4 months vs. 44.0 ± 6.3 months / 53.6 ± 6.7 months, respectively; p < .001 / p = .825). Also, subjects with BTV below 10 cm3 that did not undergo surgery had a similar PFS as subjects who underwent surgery (40.2 ± 6.0 months vs. 52.4 ± 8.9 months, respectively, p = .587). Subjects with BTV above 10 cm3 and without surgery had a significantly worse PFS (13.8 ± 3.3 months, p < .001). Multivariate analysis showed that the prognostication by clinical parameters is improved by adding TBRmax to the model (AUC 0.945 (95% CI: 0.881-1.000), true classification rate 88.1%). CONCLUSION: FET-PET may provide added value for the prognostication of relapsing oligodendroglioma in addition to clinical parameters.


Assuntos
Neoplasias Encefálicas , Glioma , Oligodendroglioma , Adulto , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia , Humanos , Recidiva Local de Neoplasia/diagnóstico por imagem , Oligodendroglioma/diagnóstico por imagem , Oligodendroglioma/cirurgia , Tomografia por Emissão de Pósitrons , Prognóstico , Tirosina
2.
Eur J Nucl Med Mol Imaging ; 46(6): 1359-1368, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30426151

RESUMO

BACKGROUND: To evaluate the diagnostic accuracy of positron emission tomography/computed tomography with 18F-fluorodeoxyglucose (PET/CT), contrast-enhanced CT (CE-CT), and a combined imaging approach (CE-PET/CT) in patients with suspected vascular graft infection (VGI). METHODS: PET/CT and CE-CT were performed prospectively in 23 patients with suspected VGI. Diagnostic accuracy for PET/CT was assessed by using previously suggested cut-off points for maximum standardized uptake values (SUVmax) measured in the vicinity of the graft. Using a new 4-point scale for visual grading, two readers independently assessed the diagnostic accuracy for CE-CT and combined CE-PET/CT. Microbiological culture, obtained after open biopsy or graft explantation, and clinical follow-up of the patients served as the standard of reference. RESULTS: Sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV), and accuracy of PET/CT for the diagnosis of VGI was 100%, 50%, 100%, 72.2%, and 78.3%, using the most favorable SUVmax cut-off ≥ 4.9. Respective values for CE-CT were 100%, 50%, 100%, 72.2%, and 78.3% for reader 1, and 92.3%, 80%, 88.9%, 85.7%, and 86.9% for reader 2; while respective values for combined CE-PET/CT were 100%, 70%, 100%, 81.3%, and 86.9% for reader 1, and 100%, 80%, 100%, 86.7%, and 91.3% for reader 2. Additionally, imaging provided a conclusive clinical diagnosis in patients without graft infection (i.e., other sites of infection): five of ten patients with CE-CT, six of ten patients with PET/CT, and seven of ten patients with combined CE-PET/CT. CONCLUSION: The diagnostic accuracy of combined CE-PET/CT in patients with suspected VGI is very high. The combination of the high sensitivity of PET/CT in detecting metabolically active foci in infection, and the high specificity of CE-CT in detecting anatomic alterations, appears to be the reason why combined imaging outperforms stand-alone imaging in diagnosing VGI and may be supportive in future decision-making of difficult cases of suspected VGI. Clinical Trials.gov Identifier: NCT01821664.


Assuntos
Prótese Vascular/microbiologia , Meios de Contraste/química , Fluordesoxiglucose F18/análise , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Infecções Relacionadas à Prótese/diagnóstico por imagem , Veias/transplante , Idoso , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Complicações Pós-Operatórias , Valor Preditivo dos Testes , Estudos Prospectivos , Infecções Relacionadas à Prótese/microbiologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
3.
Eur J Nucl Med Mol Imaging ; 45(1): 20-30, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29032394

RESUMO

PURPOSE: Sensitive visualization of recurrent prostate cancer foci is a challenge in patients with early biochemical recurrence (EBR). The recently established 68Ga-PSMA-11 PET/CT has significantly improved the detection rate with published values of up to 55% for patients with a serum PSA concentration between 0.2-0.5 ng/mL. The increased soft tissue contrast in the pelvis using simultaneous 68Ga-PSMA-11 PET/MRI might further improve the detection rate in patients with EBR and low PSA values over PET/CT. METHODS: We retrospectively analyzed a cohort of 56 consecutive patients who underwent a 68Ga-PSMA-11 PET/MRI for biochemical recurrence in our institution between April and December 2016 with three readers. Median PSA level was 0.99 ng/mL (interquartile range: 3.1 ng/mL). Detection of PSMA-positive lesions within the prostate fossa, local and distant lymph nodes, bones, or visceral organs was recorded. Agreement among observers was evaluated with Fleiss's kappa (k). RESULTS: Overall, in 44 of 56 patients (78.6%) PSMA-positive lesions were detected. In four of nine patients (44.4%) with a PSA < 0.2 ng/mL, suspicious lesions were detected (two pelvic and one paraaortic lymph nodes, and two bone metastases). In eight of 11 patients (72.7%) with a PSA between 0.2 and < 0.5 ng/mL, suspicious lesions were detected (two local recurrences, six lymph nodes, and one bone metastasis). Five out of 20 patients with a PSA < 0.5 ng/mL had extrapelvic disease. In 12 of 15 patients (80.0%) with a PSA between 0.5 and < 2.0 ng/mL, suspicious lesions were detected (four local recurrences, nine lymph nodes, and four bone metastases). In 20 of 21 patients (95.2%) with a PSA >2.0 ng/mL, suspicious lesions were detected. The overall interreader agreement for cancer detection was excellent (κ = 0.796, CI 0.645-0.947). CONCLUSIONS: Our data show that 68Ga-PSMA-11 PET/MRI has a high detection rate for recurrent prostate cancer even at very low PSA levels <0.5 ng/mL. Furthermore, even at those low levels extrapelvic disease can be localized in 25% of the cases and local recurrence alone is seen only in 10%.


Assuntos
Ácido Edético/análogos & derivados , Imageamento por Ressonância Magnética/métodos , Recidiva Local de Neoplasia/diagnóstico por imagem , Oligopeptídeos , Tomografia por Emissão de Pósitrons/métodos , Neoplasias da Próstata/diagnóstico por imagem , Compostos Radiofarmacêuticos , Idoso , Idoso de 80 Anos ou mais , Isótopos de Gálio , Radioisótopos de Gálio , Humanos , Imageamento por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Imagem Multimodal/normas , Recidiva Local de Neoplasia/patologia , Tomografia por Emissão de Pósitrons/normas , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia
4.
Eur J Nucl Med Mol Imaging ; 45(11): 1987-1997, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29948106

RESUMO

PURPOSE: 18F-FDG PET/CT (PET/CT) is a useful tool for the diagnosis of aortic graft infection (AGI), but has rarely been used to influence therapeutic decisions during follow-up. We aimed to study the role of PET/CT in the long-term monitoring of patients. METHODS: Participants of the prospective Vascular Graft Infection Cohort Study (VASGRA) were included if they had microbiologically proven AGI. We quantified the metabolic activity in PET/CT by using maximum standardized uptake value (SUVmax) and further classified it as being focal or diffuse. Multivariable linear regression models were fit using generalized estimating equations to investigate factors associated with SUVmax over time. RESULTS: Sixty-eight participants with AGI contributed to 266 PET/CTs including 36 examinations performed after stop of antimicrobial therapy. Higher C-reactive protein (CRP) (adjusted coefficient per log10 mg/L 0.05 [95% C.I. 0.02-0.08]) was associated with higher SUVmax. CRP, metabolic and clinical findings informed the decision to either start (medians of SUVmax 7.1 and CRP 31.5 mg/L; 100% focal uptake), escalate (SUVmax 9.5; CRP 31.5; 100% focal uptake), continue (SUVmax 6.0; CRP 9.95 mg/L; 90% focal uptake), or stop (SUVmax 4.3; CRP 3.5 mg/L; 61% focal uptake) antibiotic treatment. Of note, decisions to escalate or continue antibiotic treatment were taken despite normal CRP values in 12.5 and 35.7% of PET/CTs, respectively. CONCLUSIONS: Consecutive PET/CTs could influence the clinical decision-making in patients with AGI in the near future. More studies on the use of PET/CT in case of aortic graft infection may offer the potential for individualized treatment approaches. CLINICALTRIALS. GOV IDENTIFIER: NCT01821664.


Assuntos
Aorta/cirurgia , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/terapia , Enxerto Vascular/efeitos adversos , Idoso , Feminino , Humanos , Achados Incidentais , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/etiologia
5.
AJR Am J Roentgenol ; 208(4): 777-784, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28177655

RESUMO

OBJECTIVE: The purpose of this study was to determine whether use of iterative image reconstruction algorithms improves the accuracy of coronary CT angiography (CCTA) compared with intravascular ultrasound (IVUS) in semiautomated plaque burden assessment. MATERIALS AND METHODS: CCTA and IVUS images of seven coronary arteries were acquired ex vivo. CT images were reconstructed with filtered back projection (FBP) and adaptive statistical (ASIR) and model-based (MBIR) iterative reconstruction algorithms. Cross-sectional images of the arteries were coregistered between CCTA and IVUS in 1-mm increments. In CCTA, fully automated (without manual corrections) and semiautomated (allowing manual corrections of vessel wall boundaries) plaque burden assessments were performed for each of the reconstruction algorithms with commercially available software. In IVUS, plaque burden was measured manually. Agreement between CCTA and IVUS was determined with Pearson correlation. RESULTS: A total of 173 corresponding cross sections were included. The mean plaque burden measured with IVUS was 63.39% ± 10.63%. With CCTA and the fully automated technique, it was 54.90% ± 11.70% with FBP, 53.34% ± 13.11% with ASIR, and 55.35% ± 12.22% with MBIR. With CCTA and the semiautomated technique mean plaque burden was 54.90% ± 11.76%, 53.40% ± 12.85%, 57.09% ± 11.05%. Manual correction of the semiautomated assessments was performed in 39% of all cross sections and improved plaque burden correlation with the IVUS assessment independently of reconstruction algorithm (p < 0.0001). Furthermore, MBIR was superior to FBP and ASIR independently of assessment method (semiautomated, r = 0.59 for FBP, r = 0.52 for ASIR, r = 0.78 for MBIR, all p < 0.001; fully automated, r = 0.40 for FBP, r = 0.37 for ASIR, r = 0.53 for MBIR, all p < 0.001). CONCLUSION: For the quantification of plaque burden with CCTA, MBIR led to better correlation with IVUS than did traditional reconstruction algorithms such as FBP, independently of the use of a fully automated or semiautomated assessment approach. The highest accuracy for quantifying plaque burden with CCTA can be achieved by using MBIR data with semiautomated assessment.


Assuntos
Estenose das Carótidas/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Ultrassonografia de Intervenção/métodos , Adulto , Idoso , Algoritmos , Humanos , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Radiology ; 277(1): 64-72, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25942503

RESUMO

PURPOSE: To investigate the accuracy of x-ray grating interferometry phase-contrast (PC) imaging for the characterization of human coronary artery plaque. MATERIALS AND METHODS: PC and conventional absorption computed tomographic (CT) imaging was performed ex vivo in this institutional review board-approved study in 40 human coronary artery segments by using a synchrotron radiation source. Qualitative analyses and calculations of image quality (McNemar test), plaque components (McNemar test), and plaque classification (Cohen κ test) according to the American Heart Association classification were performed in 38 plaques detected at histopathologic examination (reference standard). Quantitative measurements of plaque components (ie, collagen, lipids, smooth muscle, and calcifications) were compared among PC and absorption images by using analysis of variance for repeated measures with post hoc Bonferroni correction. RESULTS: Image quality was superior in PC (median image score, 1) in all cases (100%) compared with absorption imaging (median image score, 3) (P < .001). Plaque components were detected by means of PC without significant differences (seven of seven calcifications, 22 of 22 plaques with collagen and smooth muscle cells, P > .99; 29 of 29 plaques with lipids, P = .10) with histopathologic findings, whereas absorption imaging was used to detect calcifications (seven of seven, P > .99) without statistical differences only (nine of 29 plaques with lipids, 0 of 22 plaques with collagen and smooth muscle cells, P < .001). Accuracy for plaque stage assessment with PC (early vs advanced) was 100%, and characterization was correct in 33 of 38 plaques (87%), while conventional absorption imaging allowed correct characterization of seven plaques only (18%, P < .001). PC CT numbers were significantly different (P < .05) for all plaque components (mean for calcifications, 1236 HU ± 69; collagen, 78 HU ± 24; lipids, -18 HU ± 23; and smooth muscle cells, 34 HU ± 12), whereas absorption images showed significant differences (P < .001) between calcifications (1336 HU ± 241) and other plaque components, but not for collagen (22 HU ± 13), lipids (-15 HU ± 14), and smooth muscle (13 HU ± 9) (P > .99). CONCLUSION: PC imaging allows accurate characterization of human coronary artery plaques and quantitative assessment of plaque components, thereby outperforming absorption imaging.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Tomografia Computadorizada por Raios X , Adulto , Cadáver , Doença da Artéria Coronariana/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/complicações , Reprodutibilidade dos Testes , Adulto Jovem
7.
Thorac Cardiovasc Surg ; 63(4): 270-6, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25463355

RESUMO

OBJECTIVE: Coronary angiography (CA) remains the standard for preoperative planning for surgical revascularization. However, besides anatomical imaging, current guidelines recommend additional functional imaging before a therapy decision is made. We assess the impact of functional imaging on the strategy of coronary artery bypass grafting (CABG) with particular regards on postoperative patency and myocardial perfusion. METHODS: After CA, 55 patients (47 males/8 females; age: 65.1 ± 9.5 years) underwent perfusion cardiovascular magnetic resonance (CMR) and dual-source computed tomography (DSCT) before isolated CABG (n = 31), CABG and concomitant valve surgery (valve + CABG; n = 10) and isolated valve surgery (n = 14; control). DSCT was used for analysis of significant stenosis, CMR for myocardial-perfusion to discriminate between: no ischemia (normal), ischemia, or scar. The results, unknown to the surgeons, were compared with CA and related to the location and number of distal anastomoses. Nineteen CABG patients underwent follow-up CMR and DSCT (FU: 13 ± 3 months) to compare the preop findings with the postop outcomes. RESULTS: Thirty-nine patients either received CABG alone (n = 31) or a combined procedure (n = 10) with a total of 116 distal anastomoses. DSCT was compared with CA regarding accuracy of coronary stenosis and showed 91% sensitivity, 88% specificity, and negative/positive predictive values of 89/90%. In total, 880 myocardial segments (n = 55, 16 segments/patient) were assessed by CMR. In 17% (149/880) of segments ischemia and in 8% (74/880) scar tissue was found. Interestingly, 14% (16/116) of bypass-anastomoses were placed on non-ischemic myocardium and 3% (4/116) on scar tissue. In a subgroup of 19 patients 304 segments were evaluated. Thirty-nine percent (88/304) of all segments showed ischemia preoperatively, while 94% (83/88) of these ischemic segments did not show any ischemia postoperatively. In regard to performed anastomoses, 79% of all grafts (49/62) were optimally placed, whereas 21% (13/62) were either placed into non-ischemic myocardium or scar tissue, including 10% occluded grafts (6/62). CONCLUSION: In the whole cohort analysis, 17% of grafts were placed in regions with either no ischemia or scar tissue. The subgroup analysis revealed that 94% of all ischemic segments were successfully revascularized after CABG. Thus, functional imaging could be a promising tool in preoperative planning of revascularization strategy. Avoidance of extensive and unnecessary grafting could further optimize outcomes after CABG.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Estenose Coronária/diagnóstico , Estenose Coronária/cirurgia , Técnicas de Apoio para a Decisão , Diagnóstico por Imagem/métodos , Seleção de Pacientes , Idoso , Estudos de Casos e Controles , Angiografia Coronária , Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/complicações , Estenose Coronária/fisiopatologia , Feminino , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/cirurgia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio , Valor Preditivo dos Testes , Fatores de Risco , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Grau de Desobstrução Vascular
8.
NMR Biomed ; 27(7): 795-801, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24737306

RESUMO

The aim of this study was to quantify the response of the myocardial transverse relaxation times (ΔT2*) to hyperoxic respiratory challenge (HRC) at different field strengths in an intra-individual comparison of healthy volunteers and in a patient with coronary artery disease. Blood oxygenation level-dependent (BOLD) cardiovascular MR (CMR) data were acquired in 10 healthy volunteers (five women, five men; mean age, 29 ± 3 years; range, 22-35 years) at 1.5 and 3.0 T. Medical air (21% O2 ), pure oxygen and carbogen (95% O2 , 5% CO2 ) were administered in a block-design temporal pattern to induce normoxia, hyperoxia and hyperoxic hypercapnia, respectively. Average T2* times were derived from measurements by two independent and blind readers in 16 standard myocardial segments on three short-axis slices per patient. Inter- and intra-reader correlations of T2* measurements were good [intra-class correlation coefficient (ICC) = 0.75 and ICC = 0.79, both p < 0.001]. During normoxia, the mean T2* times were 29.9 ± 6.1 ms at 1.5 T and 27.1 ± 6.6 ms at 3.0 T. Both hyperoxic gases induced significant (all p < 0.01) T2* increases (∆T2* hyperoxia: 1.5 T, 12.7%; 3.0 T, 11.2%; hyperoxic hypercapnia: 1.5 T, 13.1%; 3.0 T, 17.7%). Analysis of variance (ANOVA) results indicated a significant (both p < 0.001) effect of the inhaled gases on the T2* times at both 1.5 T (F = 17.74) and 3.0 T (F = 39.99). With regard to the patient imaged at 1.5 T, HRC induced significant T2* increases during hyperoxia and hyperoxic hypercapnia in normal myocardial segments, whereas the T2* response was not significant in ischemic segments (p > 0.23). The myocardial ∆T2* response to HRC can reliably be imaged and quantified with BOLD CMR at both 1.5 and 3.0 T. During HRC, hyperoxia and hyperoxic hypercapnia induce a significant increase in T2*, with ∆T2* being largest at 3.0 T and during hyperoxic hypercapnia in normal myocardial segments.


Assuntos
Ventrículos do Coração/fisiopatologia , Hiperóxia/sangue , Hiperóxia/fisiopatologia , Imageamento por Ressonância Magnética , Miocárdio/patologia , Oxigênio/sangue , Adulto , Idoso de 80 Anos ou mais , Feminino , Ventrículos do Coração/patologia , Humanos , Masculino , Respiração , Adulto Jovem
9.
Eur J Nucl Med Mol Imaging ; 41(4): 649-58, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24346415

RESUMO

PURPOSE: To compare the accuracy of PET/MR imaging with that of FDG PET/CT and to determine the MR sequences necessary for the detection of liver metastasis using a trimodality PET/CT/MR set-up. METHODS: Included in this single-centre IRB-approved study were 55 patients (22 women, age 61 ± 11 years) with suspected liver metastases from gastrointestinal cancer. Imaging using a trimodality PET/CT/MR set-up (time-of-flight PET/CT and 3-T whole-body MR imager) comprised PET, low-dose CT, contrast-enhanced (CE) CT of the abdomen, and MR with T1-W/T2-W, diffusion-weighted (DWI), and dynamic CE imaging. Two readers evaluated the following image sets for liver metastasis: PET/CT (set A), PET/CECT (B), PET/MR including T1-W/T2-W (C), T1-W/T2-W with either DWI (D) or CE imaging (E), and a combination (F). The accuracy of each image set was determined by receiver-operating characteristic analysis using image set B as the standard of reference. RESULTS: Of 120 liver lesions in 21/55 patients (38%), 79 (66%) were considered malignant, and 63/79 (80%) showed abnormal FDG uptake. Accuracies were 0.937 (95% CI 89.5 - 97.9%) for image set A, 1.00 (95% CI 99.9 - 100.0%) for set C, 0.998 (95% CI 99.4 - 100.0%) for set D, 0.997 (95% CI 99.3 - 100.0%) for set E, and 0.995 (95% CI 99.0 - 100.0%) for set F. Differences were significant for image sets D - F (P < 0.05) when including lesions without abnormal FDG uptake. As shown by follow-up imaging after 50 - 177 days, the use of image sets D and both sets E and F led to the detection of metastases in one and three patients, respectively, and further metastases in the contralateral lobe in two patients negative on PET/CECT (P = 0.06). CONCLUSION: PET/MR imaging with T1-W/T2-W sequences results in similar diagnostic accuracy for the detection of liver metastases to PET/CECT. To significantly improve the characterization of liver lesions, we recommend the use of dynamic CE imaging sequences. PET/MR imaging has a diagnostic impact on clinical decision making.


Assuntos
Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Idoso , Protocolos Clínicos , Feminino , Neoplasias Gastrointestinais/patologia , Humanos , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
10.
Eur Radiol ; 24(11): 2810-8, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25052077

RESUMO

OBJECTIVES: To investigate the accuracy of post-mortem diffusion tensor imaging (DTI) for the detection of myocardial infarction (MI) and to demonstrate the feasibility of helix angle (HA) calculation to study remodelling of myofibre architecture. METHODS: Cardiac DTI was performed in 26 deceased subjects prior to autopsy for medicolegal reasons. Fractional anisotropy (FA) and mean diffusivity (MD) were determined. Accuracy was calculated on per-segment (AHA classification), per-territory, and per-patient basis, with pathology as reference standard. HAs were calculated and compared between healthy segments and those with MI. RESULTS: Autopsy demonstrated MI in 61/440 segments (13.9 %) in 12/26 deceased subjects. Healthy myocardial segments had significantly higher FA (p < 0.01) and lower MD (p < 0.001) compared to segments with MI. Multivariate logistic regression demonstrated that FA (p < 0.10) and MD (p = 0.01) with the covariate post-mortem time (p < 0.01) predicted MI with an accuracy of 0.73. Analysis of HA distribution demonstrated remodelling of myofibre architecture, with significant differences between healthy segments and segments with chronic (p < 0.001) but not with acute MI (p > 0.05). CONCLUSIONS: Post-mortem cardiac DTI enables differentiation between healthy and infarcted myocardial segments by means of FA and MD. HA assessment allows for the demonstration of remodelling of myofibre architecture following chronic MI. KEY POINTS: • DTI enables post-mortem detection of myocardial infarction with good accuracy. • A decrease in right-handed helical fibre indicates myofibre remodelling following chronic myocardial infarction. • DTI allows for ruling out myocardial infarction by means of FA. • Post-mortem DTI may represent a valuable screening tool in forensic investigations.


Assuntos
Imagem de Tensor de Difusão/métodos , Ventrículos do Coração/patologia , Imagem Cinética por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico , Miocárdio/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Anisotropia , Autopsia , Feminino , Medicina Legal/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
11.
Eur Radiol ; 24(6): 1276-82, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24599624

RESUMO

OBJECTIVE: To investigate frequent findings in cases of fatal opioid intoxication in whole-body post-mortem computed tomography (PMCT). METHODS: PMCT of 55 cases in which heroin and/or methadone had been found responsible for death were retrospectively evaluated (study group), and were compared with PMCT images of an age- and sex-matched control group. Imaging results were compared with conventional autopsy. RESULTS: The most common findings in the study group were: pulmonary oedema (95 %), aspiration (66 %), distended urinary bladder (42 %), cerebral oedema (49 %), pulmonary emphysema (38 %) and fatty liver disease (36 %). These PMCT findings occurred significantly more often in the study group than in the control group (p < 0.05). The combination of lung oedema, brain oedema and distended urinary bladder was seen in 26 % of the cases in the study group but never in the control group (0 %). This triad, as indicator of opioid-related deaths, had a specificity of 100 %, as confirmed by autopsy and toxicological analysis. CONCLUSIONS: Frequent findings in cases of fatal opioid intoxication were demonstrated. The triad of brain oedema, lung oedema and a distended urinary bladder on PMCT was highly specific for drug-associated cases of death. KEY POINTS: Frequent findings in cases of fatal opioid intoxication were investigated. Lung oedema, brain oedema and full urinary bladder represent a highly specific constellation. This combination of findings in post-mortem CT should raise suspicion of intoxication.


Assuntos
Autopsia/métodos , Patologia Legal/métodos , Dependência de Heroína/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Edema Encefálico/diagnóstico por imagem , Edema Encefálico/etiologia , Cardiomegalia/diagnóstico por imagem , Cardiomegalia/etiologia , Causas de Morte , Feminino , Heroína/efeitos adversos , Dependência de Heroína/complicações , Humanos , Masculino , Metadona/efeitos adversos , Pessoa de Meia-Idade , Entorpecentes/efeitos adversos , Edema Pulmonar/diagnóstico por imagem , Edema Pulmonar/etiologia , Estudos Retrospectivos , Sensibilidade e Especificidade , Bexiga Urinária/diagnóstico por imagem , Imagem Corporal Total/métodos , Adulto Jovem
12.
Forensic Sci Med Pathol ; 10(1): 44-9, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24174274

RESUMO

The aim of this study was to evaluate the reliability of the cardiothoracic ratio (CTR) in postmortem computed tomography (PMCT) and to assess a CTR threshold for the diagnosis of cardiomegaly based on the weight of the heart at autopsy. PMCT data of 170 deceased human adults were retrospectively evaluated by two blinded radiologists. The CTR was measured on axial computed tomography images and the actual cardiac weight was weighed at autopsy. Inter-rater reliability, sensitivity, and specificity were calculated. Receiver operating characteristic curves were calculated to assess enlarged heart weight by CTR. The autopsy definition of cardiomegaly was based on normal values of the Zeek method (within a range of both, one or two SD) and the Smith method (within the given range). Intra-class correlation coefficients demonstrated excellent agreements (0.983) regarding CTR measurements. In 105/170 (62 %) cases the CTR in PMCT was >0.5, indicating enlarged heart weight, according to clinical references. The mean heart weight measured in autopsy was 405 ± 105 g. As a result, 114/170 (67 %) cases were interpreted as having enlarged heart weights according to the normal values of Zeek within one SD, while 97/170 (57 %) were within two SD. 100/170 (59 %) were assessed as enlarged according to Smith's normal values. The sensitivity/specificity of the 0.5 cut-off of the CTR for the diagnosis of enlarged heart weight was 78/71 % (Zeek one SD), 74/55 % (Zeek two SD), and 76/59 % (Smith), respectively. The discriminative power between normal heart weight and cardiomegaly was 79, 73, and 74 % for the Zeek (1SD/2SD) and Smith methods respectively. Changing the CTR threshold to 0.57 resulted in a minimum specificity of 95 % for all three definitions of cardiomegaly. With a CTR threshold of 0.57, cardiomegaly can be identified with a very high specificity. This may be useful if PMCT is used by forensic pathologists as a screening tool for medico-legal autopsies.


Assuntos
Cardiomegalia/diagnóstico por imagem , Coração/diagnóstico por imagem , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X , Adulto , Área Sob a Curva , Autopsia , Cardiomegalia/mortalidade , Cardiomegalia/patologia , Causas de Morte , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Variações Dependentes do Observador , Tamanho do Órgão , Valor Preditivo dos Testes , Curva ROC , Radiografia Torácica/normas , Valores de Referência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/normas
13.
Abdom Imaging ; 38(5): 1136-43, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23503617

RESUMO

PURPOSE: Prospective protocol optimization, determination of image quality and diagnostic performance of virtual non-enhanced images (VNEI) derived from split-bolus dual-energy computed tomography (DECT) urography in patients with urinary stones. METHODS: IRB-approved, prospective study of 100 patients who, after written informed consent, underwent single-energy, non-enhanced CT and split-bolus, contrast-enhanced DECT (30 + 50 mL of contrast media; combined nephro-urographic acquisition). DECT was performed using setting A (80/140 kVp) in the first 20, and setting B (100/140 kVp) in the second 20 patients. Tin filtration was used in all patients. After a pre-analysis of VNEI quality, 60 additional patients were examined using setting B. Two readers qualitatively and quantitatively determined image quality of all weighted-average DECT images regarding urinary tract opacification (n = 100), and all VNEI regarding quality of iodine subtraction and urinary stone detection (n = 80). True nonenhanced (TNEI) images were the standard of reference for statistical analysis (inter-reader variability and diagnostic performance characteristics). RESULTS: The urinary tract was completely opacified in 94% (94/100) of patients. Iodine subtraction was improved (p < 0.01) and image noise of VNEI was lower (p < 0.05) in DECT setting B. On VNEI, 83% (86/104) of urinary stones were correctly identified and 17% (18/104) were missed. Stones missed (2.5 mm, 1-4) were significantly smaller than stones correctly identified (5 mm, 2-27; p < 0.001). Diagnostic accuracy was 98% on a per-renal-unit basis and 96% on a per-patient basis. Inter-reader agreements were excellent (κ = 0.91-1.00; ICC = 0.86-0.99). CONCLUSIONS: Split-bolus DECT urography was technically feasible and quality of VNEI was improved with the 100/140 kVp setting. Detection of urinary stones <4 mm on VNEI was limited.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Cálculos Urinários/diagnóstico por imagem , Urografia/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Técnica de Subtração
15.
Forensic Sci Med Pathol ; 9(3): 327-32, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23512303

RESUMO

The aim of this study was to assess the potential of monoenergetic computed tomography (CT) images to reduce beam hardening artifacts in comparison to standard CT images of dental restoration on dental post-mortem CT (PMCT). Thirty human decedents (15 male, 58 ± 22 years) with dental restorations were examined using standard single-energy CT (SECT) and dual-energy CT (DECT). DECT data were used to generate monoenergetic CT images, reflecting the X-ray attenuation at energy levels of 64, 69, 88 keV, and at an individually adjusted optimal energy level called OPTkeV. Artifact reduction and image quality of SECT and monoenergetic CT were assessed objectively and subjectively by two blinded readers. Subjectively, beam artifacts decreased visibly in 28/30 cases after monoenergetic CT reconstruction. Inter- and intra-reader agreement was good (k = 0.72, and k = 0.73 respectively). Beam hardening artifacts decreased significantly with increasing monoenergies (repeated-measures ANOVA p < 0.001). Artifact reduction was greatest on monoenergetic CT images at OPTkeV. Mean OPTkeV was 108 ± 17 keV. OPTkeV yielded the lowest difference between CT numbers of streak artifacts and reference tissues (-163 HU). Monoenergetic CT reconstructions significantly reduce beam hardening artifacts from dental restorations and improve image quality of post-mortem dental CT.


Assuntos
Artefatos , Restauração Dentária Permanente , Restauração Dentária Temporária , Patologia Legal/métodos , Tomografia Computadorizada por Raios X , Adulto , Idoso , Análise de Variância , Autopsia , Distribuição de Qui-Quadrado , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos
16.
Radiology ; 265(2): 393-401, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23012461

RESUMO

PURPOSE: To establish an ex vivo experimental setup for imaging coronary atherosclerosis with coronary computed tomographic (CT) angiography, intravascular ultrasonography (US), and optical frequency domain imaging (OFDI) and to investigate their ability to help differentiate early from advanced coronary plaques. MATERIALS AND METHODS: All procedures were performed in accordance with local and federal regulations and the Declaration of Helsinki. Approval of the local Ethics Committee was obtained. Overall, 379 histologic cuts from nine coronary arteries from three donor hearts were acquired, coregistered among modalities, and assessed for the presence and composition of atherosclerotic plaque. To assess the discriminatory capacity of the different modalities in the detection of advanced lesions, c statistic analysis was used. Interobserver agreement was assessed with the Cohen κ statistic. RESULTS: Cross sections without plaque at coronary CT angiography and with fibrous plaque at OFDI almost never showed advanced lesions at histopathologic examination (odds ratio [OR]: 0.02 and 0.06, respectively; both P<.0001), while mixed plaque at coronary CT angiography, calcified plaque at intravascular US, and lipid-rich plaque at OFDI were associated with advanced lesions (OR: 2.49, P=.0003; OR: 2.60, P=.002; and OR: 31.2, P<.0001, respectively). OFDI had higher accuracy for discriminating early from advanced lesions than intravascular US and coronary CT angiography (area under the receiver operating characteristic curve: 0.858 [95% confidence interval {CI}: 0.802, 0.913], 0.631 [95% CI: 0.554, 0.709], and 0.679 [95% CI: 0.618, 0.740]; respectively, P<.0001). Interobserver agreement was excellent for OFDI and coronary CT angiography (κ=0.87 and 0.85, respectively) and was good for intravascular US (κ=0.66). CONCLUSION: Systematic and standardized comparison between invasive and noninvasive modalities for coronary plaque characterization in ex vivo specimens demonstrated that coronary CT angiography and intravascular US are reasonably associated with plaque composition and lesion grading according to histopathologic findings, while OFDI was strongly associated. These data may help to develop initial concepts of sequential imaging strategies to identify patients with advanced coronary plaques.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Tomografia de Coerência Óptica/métodos , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia de Intervenção/métodos , Cadáver , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença
17.
Eur Radiol ; 22(10): 2067-75, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22622346

RESUMO

OBJECTIVES: To systematically assess inter-technique and inter-/intra-reader variability of coronary CT angiography (CTA) to measure plaque burden compared with intravascular ultrasound (IVUS) and to determine whether iterative reconstruction algorithms affect variability. METHODS: IVUS and CTA data were acquired from nine human coronary arteries ex vivo. CT images were reconstructed using filtered back projection (FBPR) and iterative reconstruction algorithms: adaptive-statistical (ASIR) and model-based (MBIR). After co-registration of 284 cross-sections between IVUS and CTA, two readers manually delineated the cross-sectional plaque area in all images presented in random order. RESULTS: Average plaque burden by IVUS was 63.7 ± 10.7% and correlated significantly with all CTA measurements (r = 0.45-0.52; P < 0.001), while CTA overestimated the burden by 10 ± 10%. There were no significant differences among FBPR, ASIR and MBIR (P > 0.05). Increased overestimation was associated with smaller plaques, eccentricity and calcification (P < 0.001). Reproducibility of plaque burden by CTA and IVUS datasets was excellent with a low mean intra-/inter-reader variability of <1/<4% for CTA and <0.5/<1% for IVUS respectively (P < 0.05) with no significant difference between CT reconstruction algorithms (P > 0.05). CONCLUSION: In ex vivo coronary arteries, plaque burden by coronary CTA had extremely low inter-/intra-reader variability and correlated significantly with IVUS measurements. Accuracy as well as reader reliability were independent of CT image reconstruction algorithm. KEY POINTS: • IVUS is deemed the gold standard in-vivo coronary plaque assessment • But coronary CT angiography findings correlate strongly with IVUS results • Coronary CT angiography now allows plaque quantification close to IVUS • Iterative image reconstruction algorithms do not alter accuracy or reproducibility • Plaque quantification is more challenging in smaller eccentric calcified lesions.


Assuntos
Algoritmos , Angiografia Coronária/normas , Placa Aterosclerótica/diagnóstico por imagem , Ultrassonografia de Intervenção , Humanos , Processamento de Imagem Assistida por Computador , Técnicas In Vitro , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
19.
Radiology ; 259(3): 704-11, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21467254

RESUMO

PURPOSE: To assess a late gadolinium enhancement (LGE) single-breath-hold three-dimensional (3D) inversion recovery magnetic resonance (MR) imaging sequence for the quantification of myocardial scar mass and transmurality in comparison with a clinically established two-dimensional (2D) sequence. MATERIALS AND METHODS: All patients gave written informed consent to participate in this institutional review board-approved study. Ninety patients (84 men; mean age, 54.4 years ± 10.8 [standard deviation]) with acute (n = 30), subacute (n = 30), or chronic (n = 30) myocardial infarction were included. Imaging was performed by using a 1.5-T clinical MR imaging system. Spatial resolution was identical for 3D and 2D images (1.5 × 1.5 mm(2); section thickness, 8 mm; no section gap). Quantitative comparisons of myocardial mass (in grams), scar mass (in grams), and scar transmurality (on a five-point scale) were performed by using the Pearson correlation and Bland-Altman analysis (for myocardial and scar mass) or κ statistics (for transmurality). RESULTS: There were no significant differences between 2D and 3D data sets in terms of mean myocardial mass (2D: 148.3 g ± 35.1; 3D: 148.1 g ± 34.6; P = .76) and scar tissue mass (2D: 31.8 g ± 14.6; 3D: 31.6 g ± 15.5; P = .39), with strong and significant correlation regarding both myocardial mass (r = 0.982; P < .001) and scar tissue mass (r = 0.980; P < .001). Bland-Altman analysis showed a mean difference of 0.21 g ± 6.64 (range, -19.64 to 18.44 g) for myocardial mass and a mean difference of 0.26 g ± 2.88 (range, -7.15 to 7.74 g) for scar mass between the 2D and 3D data sets. Agreement regarding scar transmurality was good (κ = 0.75). Acquisition time was significantly shorter for 3D data sets (26.7 seconds ± 4.4 vs 367.7 seconds ± 56.4; P < .001). CONCLUSION: Three-dimensional LGE MR imaging enables quantitative evaluation of scar tissue mass and transmurality in patients with acute, subacute, or chronic myocardial infarction at significantly reduced acquisition times compared with 2D LGE MR imaging.


Assuntos
Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico , Doença Aguda , Distribuição de Qui-Quadrado , Doença Crônica , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/patologia , Compostos Organometálicos , Estatísticas não Paramétricas
20.
Eur Radiol ; 21(8): 1628-34, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21373773

RESUMO

OBJECTIVE: To prospectively examine coronary artery plaques as predictors of myocardial ischaemia using cardiac magnetic resonance (CMR). METHODS: Fifty-two patients (46 men; age 64 ± 10) with suspected coronary artery disease (CAD) referred for catheter coronary angiography (CA) underwent CMR and computed tomography coronary angiography (CTCA). All coronary segments were evaluated for morphological stenosis based on CA. Any plaque according to its composition was assessed based on CTCA. RESULTS: Numbers of total and calcified coronary artery plaques represented the best predictors of myocardial ischaemia (AUC = 0.87; [95%CI: 0.77-0.97] and AUC = 0.87; [95%CI: 0.77-0.96], respectively, p = 0.56) with the total plaque number significantly higher in patients with corresponding ischaemia than those without (p < 0.01, p < 0.05 adjusted for pre-test probability and stenosis). Compared with the AUC of coronary stenosis assessment by CA (AUC = 0.90; [95%CI: 0.80-1.00]), AUCs were equivalent using either the total number or the number of calcified plaques alone (p = 0.73 and p = 0.69). Multivariate logistic regression analyses demonstrated the total plaque number as an independent predictor of ischaemia (odds +20%; [95%CI: 1.096-1.368]), improving a model including clinical probability estimates of CAD (c-statistics, 0.66 to 0.89). CONCLUSION: Coronary artery plaque number according to CTCA is a significant, independent predictor of myocardial ischaemia with similar accuracy to stenosis assessment.


Assuntos
Calcinose/diagnóstico , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Imageamento por Ressonância Magnética/métodos , Isquemia Miocárdica/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Idoso , Análise de Variância , Área Sob a Curva , Calcinose/diagnóstico por imagem , Meios de Contraste , Estudos Transversais , Feminino , Humanos , Iohexol/análogos & derivados , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Valor Preditivo dos Testes , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA