Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 162
Filtrar
1.
Anesthesiology ; 139(3): 342-353, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37402248

RESUMO

Opioids are effective analgesics, but they can have harmful adverse effects, such as addiction and potentially fatal respiratory depression. Naloxone is currently the only available treatment for reversing the negative effects of opioids, including respiratory depression. However, the effectiveness of naloxone, particularly after an opioid overdose, varies depending on the pharmacokinetics and the pharmacodynamics of the opioid that was overdosed. Long-acting opioids, and those with a high affinity at the µ-opioid receptor and/or slow receptor dissociation kinetics, are particularly resistant to the effects of naloxone. In this review, the authors examine the pharmacology of naloxone and its safety and limitations in reversing opioid-induced respiratory depression under different circumstances, including its ability to prevent cardiac arrest.


Assuntos
Overdose de Drogas , Parada Cardíaca , Overdose de Opiáceos , Insuficiência Respiratória , Humanos , Naloxona/farmacologia , Naloxona/uso terapêutico , Analgésicos Opioides/efeitos adversos , Antagonistas de Entorpecentes/farmacologia , Antagonistas de Entorpecentes/uso terapêutico , Overdose de Opiáceos/tratamento farmacológico , Insuficiência Respiratória/induzido quimicamente , Insuficiência Respiratória/prevenção & controle , Insuficiência Respiratória/tratamento farmacológico , Overdose de Drogas/tratamento farmacológico , Parada Cardíaca/induzido quimicamente , Parada Cardíaca/tratamento farmacológico , Parada Cardíaca/prevenção & controle
2.
JAMA ; 328(14): 1405-1414, 2022 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-36219407

RESUMO

Importance: Opioids can cause severe respiratory depression by suppressing feedback mechanisms that increase ventilation in response to hypercapnia. Following the addition of boxed warnings to benzodiazepine and opioid products about increased respiratory depression risk with simultaneous use, the US Food and Drug Administration evaluated whether other drugs that might be used in place of benzodiazepines may cause similar effects. Objective: To study whether combining paroxetine or quetiapine with oxycodone, compared with oxycodone alone, decreases the ventilatory response to hypercapnia. Design, Setting, and Participants: Randomized, double-blind, crossover clinical trial at a clinical pharmacology unit (West Bend, Wisconsin) with 25 healthy participants from January 2021 through May 25, 2021. Interventions: Oxycodone 10 mg on days 1 and 5 and the following in a randomized order for 5 days: paroxetine 40 mg daily, quetiapine twice daily (increasing daily doses from 100 mg to 400 mg), or placebo. Main Outcomes and Measures: Ventilation at end-tidal carbon dioxide of 55 mm Hg (hypercapnic ventilation) using rebreathing methodology assessed for paroxetine or quetiapine with oxycodone, compared with placebo and oxycodone, on days 1 and 5 (primary) and for paroxetine or quetiapine alone compared with placebo on day 4 (secondary). Results: Among 25 participants (median age, 35 years [IQR, 30-40 years]; 11 female [44%]), 19 (76%) completed the trial. The mean hypercapnic ventilation was significantly decreased with paroxetine plus oxycodone vs placebo plus oxycodone on day 1 (29.2 vs 34.1 L/min; mean difference [MD], -4.9 L/min [1-sided 97.5% CI, -∞ to -0.6]; P = .01) and day 5 (25.1 vs 35.3 L/min; MD, -10.2 L/min [1-sided 97.5% CI, -∞ to -6.3]; P < .001) but was not significantly decreased with quetiapine plus oxycodone vs placebo plus oxycodone on day 1 (33.0 vs 34.1 L/min; MD, -1.2 L/min [1-sided 97.5% CI, -∞ to 2.8]; P = .28) or on day 5 (34.7 vs 35.3 L/min; MD, -0.6 L/min [1-sided 97.5% CI, -∞ to 3.2]; P = .37). As a secondary outcome, mean hypercapnic ventilation was significantly decreased on day 4 with paroxetine alone vs placebo (32.4 vs 41.7 L/min; MD, -9.3 L/min [1-sided 97.5% CI, -∞ to -3.9]; P < .001), but not with quetiapine alone vs placebo (42.8 vs 41.7 L/min; MD, 1.1 L/min [1-sided 97.5% CI, -∞ to 6.4]; P = .67). No drug-related serious adverse events were reported. Conclusions and Relevance: In this preliminary study involving healthy participants, paroxetine combined with oxycodone, compared with oxycodone alone, significantly decreased the ventilatory response to hypercapnia on days 1 and 5, whereas quetiapine combined with oxycodone did not cause such an effect. Additional investigation is needed to characterize the effects after longer-term treatment and to determine the clinical relevance of these findings. Trial Registration: ClinicalTrials.gov Identifier: NCT04310579.


Assuntos
Analgésicos Opioides , Antidepressivos , Oxicodona , Paroxetina , Fumarato de Quetiapina , Insuficiência Respiratória , Adulto , Analgésicos Opioides/efeitos adversos , Analgésicos Opioides/farmacologia , Antidepressivos/efeitos adversos , Antidepressivos/farmacologia , Benzodiazepinas/efeitos adversos , Benzodiazepinas/farmacologia , Dióxido de Carbono/análise , Método Duplo-Cego , Feminino , Humanos , Hipercapnia/etiologia , Oxicodona/efeitos adversos , Oxicodona/farmacologia , Paroxetina/efeitos adversos , Paroxetina/farmacologia , Fumarato de Quetiapina/efeitos adversos , Fumarato de Quetiapina/farmacologia , Respiração/efeitos dos fármacos , Insuficiência Respiratória/induzido quimicamente , Insuficiência Respiratória/diagnóstico
3.
JAMA ; 326(3): 240-249, 2021 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-34180947

RESUMO

Importance: In 2019, the US Food and Drug Administration (FDA) received a citizen petition indicating that ranitidine contained the probable human carcinogen N-nitrosodimethylamine (NDMA). In addition, the petitioner proposed that ranitidine could convert to NDMA in humans; however, this was primarily based on a small clinical study that detected an increase in urinary excretion of NDMA after oral ranitidine consumption. Objective: To evaluate the 24-hour urinary excretion of NDMA after oral administration of ranitidine compared with placebo. Design, Setting, and Participants: Randomized, double-blind, placebo-controlled, crossover clinical trial at a clinical pharmacology unit (West Bend, Wisconsin) conducted in 18 healthy participants. The study began in June 2020, and the end of participant follow-up was July 1, 2020. Interventions: Participants were randomized to 1 of 4 treatment sequences and over 4 periods received ranitidine (300 mg) and placebo (randomized order) with a noncured-meats diet and then a cured-meats diet. The cured-meats diet was designed to have higher nitrites, nitrates (nitrate-reducing bacteria can convert nitrates to nitrites), and NDMA. Main Outcome and Measure: Twenty-four-hour urinary excretion of NDMA. Results: Among 18 randomized participants (median age, 33.0 [interquartile range {IQR}, 28.3 to 42.8] years; 9 women [50%]; 7 White [39%], 11 African American [61%]; and 3 Hispanic or Latino ethnicity [17%]), 17 (94%) completed the trial. The median 24-hour NDMA urinary excretion values for ranitidine and placebo were 0.6 ng (IQR, 0 to 29.7) and 10.5 ng (IQR, 0 to 17.8), respectively, with a noncured-meats diet and 11.9 ng (IQR, 5.6 to 48.6) and 23.4 ng (IQR, 8.6 to 36.7), respectively, with a cured-meats diet. There was no statistically significant difference between ranitidine and placebo in 24-hour urinary excretion of NDMA with a noncured-meats diet (median of the paired differences, 0 [IQR, -6.9 to 0] ng; P = .54) or a cured-meats diet (median of the paired differences, -1.1 [IQR, -9.1 to 11.5] ng; P = .71). No drug-related serious adverse events were reported. Conclusions and Relevance: In this trial that included 18 healthy participants, oral ranitidine (300 mg), compared with placebo, did not significantly increase 24-hour urinary excretion of NDMA when participants consumed noncured-meats or cured-meats diets. The findings do not support that ranitidine is converted to NDMA in a general, healthy population. Trial Registration: ClinicalTrials.gov Identifier: NCT04397445.


Assuntos
Dimetilnitrosamina/urina , Antagonistas dos Receptores H2 da Histamina/farmacocinética , Ranitidina/farmacocinética , Administração Oral , Adulto , Estudos Cross-Over , Método Duplo-Cego , Feminino , Antagonistas dos Receptores H2 da Histamina/administração & dosagem , Humanos , Masculino , Placebos/farmacocinética , Ranitidina/administração & dosagem
4.
BMC Bioinformatics ; 21(1): 163, 2020 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-32349656

RESUMO

BACKGROUND: While clinical trials are considered the gold standard for detecting adverse events, often these trials are not sufficiently powered to detect difficult to observe adverse events. We developed a preliminary approach to predict 135 adverse events using post-market safety data from marketed drugs. Adverse event information available from FDA product labels and scientific literature for drugs that have the same activity at one or more of the same targets, structural and target similarities, and the duration of post market experience were used as features for a classifier algorithm. The proposed method was studied using 54 drugs and a probabilistic approach of performance evaluation using bootstrapping with 10,000 iterations. RESULTS: Out of 135 adverse events, 53 had high probability of having high positive predictive value. Cross validation showed that 32% of the model-predicted safety label changes occurred within four to nine years of approval (median: six years). CONCLUSIONS: This approach predicts 53 serious adverse events with high positive predictive values where well-characterized target-event relationships exist. Adverse events with well-defined target-event associations were better predicted compared to adverse events that may be idiosyncratic or related to secondary target effects that were poorly captured. Further enhancement of this model with additional features, such as target prediction and drug binding data, may increase accuracy.


Assuntos
Sistemas de Notificação de Reações Adversas a Medicamentos , Biologia Computacional/métodos , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/diagnóstico , Algoritmos , Humanos
5.
Toxicol Appl Pharmacol ; 394: 114961, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-32209365

RESUMO

INTRODUCTION: hERG block potency is widely used to calculate a drug's safety margin against its torsadogenic potential. Previous studies are confounded by use of different patch clamp electrophysiology protocols and a lack of statistical quantification of experimental variability. Since the new cardiac safety paradigm being discussed by the International Council for Harmonisation promotes a tighter integration of nonclinical and clinical data for torsadogenic risk assessment, a more systematic approach to estimate the hERG block potency and safety margin is needed. METHODS: A cross-industry study was performed to collect hERG data on 28 drugs with known torsadogenic risk using a standardized experimental protocol. A Bayesian hierarchical modeling (BHM) approach was used to assess the hERG block potency of these drugs by quantifying both the inter-site and intra-site variability. A modeling and simulation study was also done to evaluate protocol-dependent changes in hERG potency estimates. RESULTS: A systematic approach to estimate hERG block potency is established. The impact of choosing a safety margin threshold on torsadogenic risk evaluation is explored based on the posterior distributions of hERG potency estimated by this method. The modeling and simulation results suggest any potency estimate is specific to the protocol used. DISCUSSION: This methodology can estimate hERG block potency specific to a given voltage protocol. The relationship between safety margin thresholds and torsadogenic risk predictivity suggests the threshold should be tailored to each specific context of use, and safety margin evaluation may need to be integrated with other information to form a more comprehensive risk assessment.


Assuntos
Canal de Potássio ERG1/antagonistas & inibidores , Medição de Risco/métodos , Torsades de Pointes/induzido quimicamente , Teorema de Bayes , Simulação por Computador , Humanos , Modelos Biológicos , Técnicas de Patch-Clamp , Bloqueadores dos Canais de Potássio/farmacologia , Segurança , Torsades de Pointes/fisiopatologia
6.
JAMA ; 323(3): 256-267, 2020 01 21.
Artigo em Inglês | MEDLINE | ID: mdl-31961417

RESUMO

Importance: A prior pilot study demonstrated the systemic absorption of 4 sunscreen active ingredients; additional studies are needed to determine the systemic absorption of additional active ingredients and how quickly systemic exposure exceeds 0.5 ng/mL as recommended by the US Food and Drug Administration (FDA). Objective: To assess the systemic absorption and pharmacokinetics of the 6 active ingredients (avobenzone, oxybenzone, octocrylene, homosalate, octisalate, and octinoxate) in 4 sunscreen products under single- and maximal-use conditions. Design, Setting, and Participants: Randomized clinical trial at a clinical pharmacology unit (West Bend, Wisconsin) was conducted in 48 healthy participants. The study was conducted between January and February 2019. Interventions: Participants were randomized to 1 of 4 sunscreen products, formulated as lotion (n = 12), aerosol spray (n = 12), nonaerosol spray (n = 12), and pump spray (n = 12). Sunscreen product was applied at 2 mg/cm2 to 75% of body surface area at 0 hours on day 1 and 4 times on day 2 through day 4 at 2-hour intervals, and 34 blood samples were collected over 21 days from each participant. Main Outcomes and Measures: The primary outcome was the maximum plasma concentration of avobenzone over days 1 through 21. Secondary outcomes were the maximum plasma concentrations of oxybenzone, octocrylene, homosalate, octisalate, and octinoxate over days 1 through 21. Results: Among 48 randomized participants (mean [SD] age, 38.7 [13.2] years; 24 women [50%]; 23 white [48%], 23 African American [48%], 1 Asian [2%], and 1 of unknown race/ethnicity [2%]), 44 (92%) completed the trial. Geometric mean maximum plasma concentrations of all 6 active ingredients were greater than 0.5 ng/mL, and this threshold was surpassed on day 1 after a single application for all active ingredients. For avobenzone, the overall maximum plasma concentrations were 7.1 ng/mL (coefficient of variation [CV], 73.9%) for lotion, 3.5 ng/mL (CV, 70.9%) for aerosol spray, 3.5 ng/mL (CV, 73.0%) for nonaerosol spray, and 3.3 ng/mL (CV, 47.8%) for pump spray. For oxybenzone, the concentrations were 258.1 ng/mL (CV, 53.0%) for lotion and 180.1 ng/mL (CV, 57.3%) for aerosol spray. For octocrylene, the concentrations were 7.8 ng/mL (CV, 87.1%) for lotion, 6.6 ng/mL (CV, 78.1%) for aerosol spray, and 6.6 ng/mL (CV, 103.9%) for nonaerosol spray. For homosalate, concentrations were 23.1 ng/mL (CV, 68.0%) for aerosol spray, 17.9 ng/mL (CV, 61.7%) for nonaerosol spray, and 13.9 ng/mL (CV, 70.2%) for pump spray. For octisalate, concentrations were 5.1 ng/mL (CV, 81.6%) for aerosol spray, 5.8 ng/mL (CV, 77.4%) for nonaerosol spray, and 4.6 ng/mL (CV, 97.6%) for pump spray. For octinoxate, concentrations were 7.9 ng/mL (CV, 86.5%) for nonaerosol spray and 5.2 ng/mL (CV, 68.2%) for pump spray. The most common adverse event was rash, which developed in 14 participants. Conclusions and Relevance: In this study conducted in a clinical pharmacology unit and examining sunscreen application among healthy participants, all 6 of the tested active ingredients administered in 4 different sunscreen formulations were systemically absorbed and had plasma concentrations that surpassed the FDA threshold for potentially waiving some of the additional safety studies for sunscreens. These findings do not indicate that individuals should refrain from the use of sunscreen. Trial Registration: ClinicalTrials.gov Identifier: NCT03582215.


Assuntos
Propiofenonas/sangue , Absorção Cutânea , Protetores Solares/farmacocinética , Acrilatos/sangue , Acrilatos/farmacocinética , Adulto , Benzofenonas/sangue , Benzofenonas/farmacocinética , Cinamatos/sangue , Cinamatos/farmacocinética , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Propiofenonas/farmacocinética , Salicilatos/sangue , Salicilatos/farmacocinética , Protetores Solares/efeitos adversos
7.
J Cardiovasc Electrophysiol ; 30(5): 709-716, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30740823

RESUMO

INTRODUCTION: We evaluated the association between a novel electrocardiographic (ECG) marker of late, rightward electrocardiographic forces (termed the lead one ratio [LOR]), and left ventricular ejection fraction (LVEF), myocardial scar, and clinical outcomes in patients with left bundle branch block (LBBB). METHODS AND RESULTS: LOR was calculated in patients with LBBB from a derivation cohort (n = 240) and receiver operator characteristic curves identified optimal threshold values for predicting myocardial scar and LVEF less than 35%. An independent validation cohort of patients with LBBB (n = 196) was used to test the association of LOR with the myocardial scar, LVEF, and the likelihood of death, heart transplant or left ventricular assist device (LVAD) implantation. The optimal thresholds in the derivation cohort were LOR less than 13.7 for identification of scar (sensitivity 55%, specificity 80%), and LOR less than 12.1 for LVEF less than 35% (sensitivity 49%, specificity 80%). In the validation cohort, LOR less than 13.7 was not associated with scar size or presence (P > 0.05 for both). LOR less than 12.1 was associated with lower LVEF (30 [20-40] versus 40 [25-55]%; P = 0.002) and predicted LVEF less than 35% in univariable (odds ratio [OR], 2.2 [1.2-4.1]; P = 0.01) and multivariable analysis (OR, 2.2 [1.2-4.3]; P = 0.02). LOR less than 12.1 was associated with scar presence when patients with nonischemic cardiomyopathy were excluded (OR = 7.2 [1.5-33.2]; P = 0.002). LOR less than 12.1 had an adjusted hazard ratio of 1.53 ([1.05-2.21]; P = 0.03) for death, transplant or LVAD implantation. CONCLUSIONS: In conclusion, ECG LOR less than 12.1 predicts reduced-LV systolic function and poorer prognosis in patients with LBBB.


Assuntos
Potenciais de Ação , Bloqueio de Ramo/diagnóstico , Cardiomiopatias/diagnóstico por imagem , Eletrocardiografia , Frequência Cardíaca , Imagem Cinética por Ressonância Magnética , Miocárdio/patologia , Disfunção Ventricular Esquerda/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Bloqueio de Ramo/mortalidade , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/terapia , Cardiomiopatias/mortalidade , Cardiomiopatias/patologia , Cardiomiopatias/terapia , Bases de Dados Factuais , Progressão da Doença , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Transplante de Coração , Coração Auxiliar , Humanos , Masculino , Pessoa de Meia-Idade , North Carolina , Pennsylvania , Valor Preditivo dos Testes , Prognóstico , Implantação de Prótese/instrumentação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Volume Sistólico , Fatores de Tempo , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda
9.
J Electrocardiol ; 54: 1-4, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30782546

RESUMO

OBJECTIVE: To determine the clinical value of correcting the QRS duration for heart rate. BACKGROUND: We recently observed [1] that the QRS duration shortens during spontaneous increases in heart rate. In the current study, we analyzed ECG and pharmacokinetic data of 21 subjects who received quinidine in a recent study [2]. They experienced the expected post-quinidine increase in heart rate, allowing us to determine if quinidine's well-known QRS prolongation might be attenuated due to the concomitant rate increase. METHODS: In a crossover-designed study, after baseline ECG recording, the subjects received quinidine 400 mg orally or placebo, and ECGs and quinidine plasma concentrations were then obtained at 15 prespecified timepoints over 24 h. The previously determined QRS-RR regression slope (0.0125) [1] was used to rate-correct QRS. Change in QRS from baseline (dQRS) and rate-corrected change in QRS from baseline (dQRSc) over time were plotted with the mean quinidine concentration and the correlation of plasma concentration with dQRS and dQRSc was assessed by pairwise correlation and linear regression. RESULTS: There was a statistically significantly greater increase in heart rate at all timepoints combined in the quinidine arm compared with the placebo arm (9.9 ±â€¯6.80 vs. 5.2 ±â€¯7.42, respectively, p < 0.0001). dQRSc was significantly greater at all timepoints combined compared with dQRS (1.99 ±â€¯4.824 vs -0.68 ±â€¯4.640 msec, respectively, p < 0.0001). dQRS correlated poorly with quinidine plasma concentration (p = 0.127), with no clear change in QRS observed. On the other hand, dQRSc correlated well with quinidine concentration (p = 0.010), with a clear rise and fall in dQRSc that mirrored the rise and fall of quinidine concentration. CONCLUSION: Rate correction of the QRS duration improves detection of QRS prolongation in the presence of heart rate change. CONDENSED ABSTRACT: Using the mean QRS - RR slope determined previously in normal volunteers [1], we corrected the QRS duration for its known dependency on heart rate in 21 subjects who received quinidine and experienced the expected post-quinidine increase in heart rate in a recent clinical trial [2]. We found that uncorrected QRS did not correlate with quinidine concentration (p = 0.127), while rate-corrected QRS correlated well (p = 0.010) and mirrored the rise and fall of quinidine concentration. Rate correction of the QRS duration improves detection of QRS prolongation in the presence of heart rate change.


Assuntos
Antiarrítmicos/farmacocinética , Eletrocardiografia , Frequência Cardíaca/efeitos dos fármacos , Quinidina/farmacocinética , Estudos Cross-Over , Humanos
10.
JAMA ; 321(21): 2082-2091, 2019 06 04.
Artigo em Inglês | MEDLINE | ID: mdl-31058986

RESUMO

Importance: The US Food and Drug Administration (FDA) has provided guidance that sunscreen active ingredients with systemic absorption greater than 0.5 ng/mL or with safety concerns should undergo nonclinical toxicology assessment including systemic carcinogenicity and additional developmental and reproductive studies. Objective: To determine whether the active ingredients (avobenzone, oxybenzone, octocrylene, and ecamsule) of 4 commercially available sunscreens are absorbed into systemic circulation. Design, Setting, and Participants: Randomized clinical trial conducted at a phase 1 clinical pharmacology unit in the United States and enrolling 24 healthy volunteers. Enrollment started in July 2018 and ended in August 2018. Interventions: Participants were randomized to 1 of 4 sunscreens: spray 1 (n = 6 participants), spray 2 (n = 6), a lotion (n = 6), and a cream (n = 6). Two milligrams of sunscreen per 1 cm2 was applied to 75% of body surface area 4 times per day for 4 days, and 30 blood samples were collected over 7 days from each participant. Main Outcomes and Measures: The primary outcome was the maximum plasma concentration of avobenzone. Secondary outcomes were the maximum plasma concentrations of oxybenzone, octocrylene, and ecamsule. Results: Among 24 participants randomized (mean age, 35.5 [SD, 1.5] years; 12 (50%] women; 14 [58%] black or African American; 14 [58%]), 23 (96%) completed the trial. For avobenzone, geometric mean maximum plasma concentrations were 4.0 ng/mL (coefficient of variation, 6.9%) for spray 1; 3.4 ng/mL (coefficient of variation, 77.3%) for spray 2; 4.3 ng/mL (coefficient of variation, 46.1%) for lotion; and 1.8 ng/mL (coefficient of variation, 32.1%). For oxybenzone, the corresponding values were 209.6 ng/mL (66.8%) for spray 1, 194.9 ng/mL (52.4%) for spray 2, and 169.3 ng/mL (44.5%) for lotion; for octocrylene, 2.9 ng/mL (102%) for spray 1, 7.8 ng/mL (113.3%) for spray 2, 5.7 ng/mL (66.3%) for lotion, and 5.7 ng/mL (47.1%) for cream; and for ecamsule, 1.5 ng/mL (166.1%) for cream. Systemic concentrations greater than 0.5 ng/mL were reached for all 4 products after 4 applications on day 1. The most common adverse event was rash, which developed in 1 participant with each sunscreen. Conclusions and Relevance: In this preliminary study involving healthy volunteers, application of 4 commercially available sunscreens under maximal use conditions resulted in plasma concentrations that exceeded the threshold established by the FDA for potentially waiving some nonclinical toxicology studies for sunscreens. The systemic absorption of sunscreen ingredients supports the need for further studies to determine the clinical significance of these findings. These results do not indicate that individuals should refrain from the use of sunscreen. Trial Registration: ClinicalTrials.gov Identifier: NCT03582215.


Assuntos
Absorção Cutânea , Protetores Solares/farmacocinética , Acrilatos/sangue , Acrilatos/farmacocinética , Adulto , Benzofenonas/sangue , Benzofenonas/farmacocinética , Canfanos/sangue , Canfanos/farmacocinética , Feminino , Voluntários Saudáveis , Humanos , Masculino , Concentração Máxima Permitida , Projetos Piloto , Propiofenonas/sangue , Propiofenonas/farmacocinética , Creme para a Pele , Ácidos Sulfônicos/sangue , Ácidos Sulfônicos/farmacocinética , Protetores Solares/administração & dosagem , Protetores Solares/análise
11.
Circulation ; 135(14): 1300-1310, 2017 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-28213480

RESUMO

BACKGROUND: Drug-induced QT interval prolongation, a risk factor for life-threatening ventricular arrhythmias, is a potential side effect of many marketed and withdrawn medications. The contribution of common genetic variants previously associated with baseline QT interval to drug-induced QT prolongation and arrhythmias is not known. METHODS: We tested the hypothesis that a weighted combination of common genetic variants contributing to QT interval at baseline, identified through genome-wide association studies, can predict individual response to multiple QT-prolonging drugs. Genetic analysis of 22 subjects was performed in a secondary analysis of a randomized, double-blind, placebo-controlled, crossover trial of 3 QT-prolonging drugs with 15 time-matched QT and plasma drug concentration measurements. Subjects received single doses of dofetilide, quinidine, ranolazine, and placebo. The outcome was the correlation between a genetic QT score comprising 61 common genetic variants and the slope of an individual subject's drug-induced increase in heart rate-corrected QT (QTc) versus drug concentration. RESULTS: The genetic QT score was correlated with drug-induced QTc prolongation. Among white subjects, genetic QT score explained 30% of the variability in response to dofetilide (r=0.55; 95% confidence interval, 0.09-0.81; P=0.02), 23% in response to quinidine (r=0.48; 95% confidence interval, -0.03 to 0.79; P=0.06), and 27% in response to ranolazine (r=0.52; 95% confidence interval, 0.05-0.80; P=0.03). Furthermore, the genetic QT score was a significant predictor of drug-induced torsade de pointes in an independent sample of 216 cases compared with 771 controls (r2=12%, P=1×10-7). CONCLUSIONS: We demonstrate that a genetic QT score comprising 61 common genetic variants explains a significant proportion of the variability in drug-induced QT prolongation and is a significant predictor of drug-induced torsade de pointes. These findings highlight an opportunity for recent genetic discoveries to improve individualized risk-benefit assessment for pharmacological therapies. Replication of these findings in larger samples is needed to more precisely estimate variance explained and to establish the individual variants that drive these effects. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01873950.


Assuntos
Arritmias Cardíacas/etiologia , Síndrome do QT Longo/induzido quimicamente , Adulto , Feminino , Estudo de Associação Genômica Ampla , Humanos , Masculino , Projetos Piloto , Polimorfismo de Nucleotídeo Único , Medição de Risco , Torsades de Pointes/etiologia
12.
J Electrocardiol ; 51(1): 68-73, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28964425

RESUMO

PURPOSE: Performance of ECG beat detectors is traditionally assessed on long intervals (e.g.: 30min), but only incorrect detections within a short interval (e.g.: 10s) may cause incorrect (i.e., missed+false) heart rate limit alarms (tachycardia and bradycardia). We propose a novel performance metric based on distribution of incorrect beat detection over a short interval and assess its relationship with incorrect heart rate limit alarm rates. BASIC PROCEDURES: Six ECG beat detectors were assessed using performance metrics over long interval (sensitivity and positive predictive value over 30min) and short interval (Area Under empirical cumulative distribution function (AUecdf) for short interval (i.e., 10s) sensitivity and positive predictive value) on two ECG databases. False heart rate limit and asystole alarm rates calculated using a third ECG database were then correlated (Spearman's rank correlation) with each calculated performance metric. MAIN FINDINGS: False alarm rates correlated with sensitivity calculated on long interval (i.e., 30min) (ρ=-0.8 and p<0.05) and AUecdf for sensitivity (ρ=0.9 and p<0.05) in all assessed ECG databases. Sensitivity over 30min grouped the two detectors with lowest false alarm rates while AUecdf for sensitivity provided further information to identify the two beat detectors with highest false alarm rates as well, which was inseparable with sensitivity over 30min. PRINCIPAL CONCLUSIONS: Short interval performance metrics can provide insights on the potential of a beat detector to generate incorrect heart rate limit alarms.


Assuntos
Alarmes Clínicos , Eletrocardiografia/instrumentação , Frequência Cardíaca , Bases de Dados Factuais , Eletrocardiografia/normas , Falha de Equipamento , Análise de Falha de Equipamento , Humanos , Teste de Materiais , Monitorização Fisiológica/instrumentação , Padrões de Referência , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador , Estatísticas não Paramétricas
13.
J Electrocardiol ; 51(6S): S25-S30, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30082088

RESUMO

The presence of left bundle branch block (LBBB) is an important predictor of benefit from cardiac resynchronization therapy (CRT). New "strict" electrocardiographic (ECG) criteria for LBBB have been shown to better predict benefit from CRT. The "strict" LBBB criteria include: QRS duration ≥140 ms (men) or ≥130 ms (women), QS- or rS-configurations of the QRS complex in leads V1 and V2, and mid-QRS notching or slurring in ≥2 of leads V1, V2, V5, V6, I and aVL. The "strict" LBBB criteria are not regularly used and most hospital automated ECG systems and physicians still use more conventional LBBB criteria. As part of the 43rd International Society for Computerized Electrocardiology (ISCE) meeting, we conducted an initiative on the automated detection of "strict" LBBB where industry and academic investigators could present their algorithm results on digital 12-lead ECGs with varying QRS morphologies from the MADIT-CRT trial (300 training and 302 test set ECGs that were manually adjudicated for "strict" LBBB presence). The results revealed a 64-82% accuracy, 48-76% sensitivity and 46-87% specificity for automated "strict" LBBB detection from 7 participants. Most mismatches were likely attributed to differences in detection and absence of specific definitions for notches and slurs while differences in QRS duration and S-waves in leads V1 and V2 were less problematic. The full unblinded training and test datasets including all ECG signals are being made available through the Telemetric and Holter ECG Warehouse (THEW) for further exploration.


Assuntos
Bloqueio de Ramo/diagnóstico , Eletrocardiografia/métodos , Sociedades Médicas , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/métodos , Humanos , Guias de Prática Clínica como Assunto
14.
J Electrocardiol ; 51(5): 779-786, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30177312

RESUMO

AIMS: We aimed to improve the electrocardiographic 2009 left bundle branch block (LBBB) Selvester QRS score (2009 LBSS) for scar assessment. METHODS: We retrospectively identified 325 LBBB patients with available ECG and cardiovascular magnetic resonance imaging (CMR) with late gadolinium enhancement from four centers (142 [44%] with CMR scar). Forty-four semi-automatically measured ECG variables pre-selected based on the 2009 LBSS yielded one multivariable model for scar detection and another for scar quantification. RESULTS: The 2009 LBSS achieved an area under the curve (AUC) of 0.60 (95% confidence interval 0.54-0.66) for scar detection, and R2 = 0.04, p < 0.001, for scar quantification. Multivariable modeling improved scar detection to AUC 0.72 (0.66-0.77) and scar quantification to R2 = 0.21, p < 0.001. CONCLUSIONS: The 2009 LBSS detects and quantifies myocardial scar with poor accuracy. Improved models with extensive comparison of ECG and CMR had modest performance, indicating limited room for improvement of the 2009 LBSS.


Assuntos
Bloqueio de Ramo/patologia , Cicatriz/diagnóstico , Eletrocardiografia , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Miocárdio/patologia , Idoso , Área Sob a Curva , Bloqueio de Ramo/complicações , Bloqueio de Ramo/fisiopatologia , Cicatriz/complicações , Feminino , Gadolínio , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
15.
J Electrocardiol ; 51(6): 1071-1076, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30497733

RESUMO

INTRODUCTION: The relationship between left ventricular (LV) ejection fraction (EF) and LV myocardial scar can identify potentially reversible causes of LV dysfunction. Left bundle branch block (LBBB) alters the electrical and mechanical activation of the LV. We hypothesized that the relationship between LVEF and scar extent is different in LBBB compared to controls. METHODS: We compared the relationship between LVEF and scar burden between patients with LBBB and scar (n = 83), and patients with chronic ischemic heart disease and scar but no electrocardiographic conduction abnormality (controls, n = 90), who had undergone cardiovascular magnetic resonance (CMR) imaging at one of three centers. LVEF (%) was measured in CMR cine images. Scar burden was quantified by CMR late gadolinium enhancement (LGE) and expressed as % of LV mass (%LVM). Maximum possible LVEF (LVEFmax) was defined as the function describing the hypotenuse in the LVEF versus myocardial scar extent scatter plot. Dysfunction index was defined as LVEFmax derived from the control cohort minus the measured LVEF. RESULTS: Compared to controls with scar, LBBB with scar had a lower LVEF (median [interquartile range] 27 [19-38] vs 36 [25-50] %, p < 0.001), smaller scar (4 [1-9] vs 11 [6-20] %LVM, p < 0.001), and greater dysfunction index (39 [30-52] vs 21 [12-35] % points, p < 0.001). CONCLUSIONS: Among LBBB patients referred for CMR, LVEF is disproportionately reduced in relation to the amount of scar. Dyssynchrony in LBBB may thus impair compensation for loss of contractile myocardium.


Assuntos
Bloqueio de Ramo/fisiopatologia , Cicatriz/complicações , Miocárdio/patologia , Volume Sistólico , Idoso , Bloqueio de Ramo/complicações , Cicatriz/fisiopatologia , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Estudos Retrospectivos
16.
Artigo em Inglês | MEDLINE | ID: mdl-28248005

RESUMO

BACKGROUND: Myocardial scar burden quantification is an emerging clinical parameter for risk stratification of sudden cardiac death and prediction of ventricular arrhythmias in patients with left ventricular dysfunction. We investigated the relationships among semiautomated Selvester score burden and late gadolinium enhancement-cardiovascular magnetic resonance (LGE-CMR) assessed scar burden and clinical outcome in patients with underlying heart failure, left bundle branch block (LBBB) and implantable cardioverter-defibrillator (ICD) treatment. METHODS: Selvester QRS scoring was performed on all subjects with ischemic and nonischemic dilated cardiomyopathy at Skåne University Hospital Lund (2002-2013) who had undergone LGE-CMR and 12-lead ECG with strict LBBB pre-ICD implantation. RESULTS: Sixty patients were included; 57% nonischemic dilated cardiomyopathy and 43% ischemic cardiomyopathy with mean left ventricular ejection fraction of 27.6% ± 11.7. All patients had scar by Selvester scoring. Sixty-two percent had scar by LGE-CMR (n = 37). The Spearman correlation coefficient for LGE-CMR and Selvester score derived scar was r = .35 (p = .007). In scar negative LGE-CMR, there was evidence of scar by Selvester scoring in all patients (range 3%-33%, median 15%). Fourteen patients (23%) had an event during the follow-up period; 11 (18%) deaths and six adequate therapies (10%). There was a moderate trend indicating that presence of scar increased the risk of clinical endpoints in the LGE-CMR analysis (p = .045). CONCLUSION: There is a modest correlation between LGE-CMR and Selvester scoring verified myocardial scar. CMR based scar burden is correlated to clinical outcome, but Selvester scoring is not. The Selvester scoring algorithm needs to be further refined in order to be clinically relevant and reliable for detailed scar evaluation in patients with LBBB.


Assuntos
Bloqueio de Ramo/fisiopatologia , Cicatriz/fisiopatologia , Meios de Contraste , Eletrocardiografia/métodos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Idoso , Bloqueio de Ramo/complicações , Bloqueio de Ramo/diagnóstico por imagem , Cicatriz/complicações , Efeitos Psicossociais da Doença , Feminino , Gadolínio , Coração/diagnóstico por imagem , Coração/fisiopatologia , Humanos , Masculino , Valor Preditivo dos Testes , Medição de Risco , Índice de Gravidade de Doença
17.
J Electrocardiol ; 50(6): 808-813, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28928044

RESUMO

The ECG plays a critical role in the thorough QT study. This clinical study is part of the assessment of proarrhythmic potential of drugs under the current regulatory paradigm. While the current paradigm has been successful in preventing drugs with unexpected QT prolongation or torsade risk from reaching the market, the focus on QT prolongation has likely resulted in potentially beneficial compounds with minimal torsade risk being dropped from development. The Comprehensive in vitro Proarrhythmia Assay (CiPA) initiative is developing and validating a new mechanistic-based paradigm for cardiac safety evaluation of drugs. The fourth component of CiPA uses ECG data in phase 1 clinical studies to confirm there are no unanticipated ion channel effects compared to nonclinical data. The J-Tpeak interval was identified as the best biomarker for differentiating QTc prolonging drugs with predominant hERG block from drugs with multichannel (hERG plus late sodium and/or calcium block). This manuscript describes ECG methods for J-Tpeak assessment and their relationship with the features of new ECG biomarkers for detecting multichannel effects under CiPA.


Assuntos
Algoritmos , Biomarcadores/análise , Bloqueadores dos Canais de Cálcio/farmacologia , Eletrocardiografia/métodos , Sistema de Condução Cardíaco/efeitos dos fármacos , Canais Iônicos/efeitos dos fármacos , Síndrome do QT Longo/induzido quimicamente , Síndrome do QT Longo/diagnóstico , Bloqueadores dos Canais de Potássio/farmacologia , Bloqueadores dos Canais de Sódio/farmacologia , Torsades de Pointes/induzido quimicamente , Torsades de Pointes/diagnóstico , Arritmias Cardíacas/induzido quimicamente , Arritmias Cardíacas/diagnóstico , Fenômenos Eletrofisiológicos , Frequência Cardíaca/efeitos dos fármacos , Frequência Cardíaca/fisiologia , Humanos , Fenetilaminas/farmacologia , Quinidina/farmacologia , Ranolazina/farmacologia , Sulfonamidas/farmacologia , Verapamil/farmacologia
18.
Europace ; 18(2): 308-14, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25805156

RESUMO

AIMS: The Selvester QRS scoring system uses quantitative criteria from the standard 12-lead electrocardiogram (ECG) to estimate the myocardial scar size of patients, including those with left bundle branch block (LBBB). Automation of the scoring system could facilitate the clinical use of this technique which requires a set of multiple QRS patterns to be identified and measured. METHODS AND RESULTS: We developed a series of algorithms to automatically detect and measure the QRS parameters required for Selvester scoring. The 'QUantitative and Automatic REport of Selvester Score' was designed specifically for the analysis of ECGs from patients meeting new strict criteria for complete LBBB. The algorithms were designed using a training (n = 36) and a validation (n = 180) set of ECGs, consisting of signal-averaged 12-lead ECGs (1000 Hz sampling) recorded from 216 LBBB patients from the MADIT-CRT. We assessed the performance of the methods using expert manually adjudicated ECGs. The average of absolute differences between automatic and adjudicated Selvester scoring was 1.2 ± 1.5 points. The range of average differences for continuous measurements of wave locations and interval durations varied between 0 and 6 ms. Erroneous detection of Q, R, S, R', and S' waves (oversensed or missed) were 3, 1, 1, 16, and 6%, respectively. Seven percent of notches detected in the first 40 ms were misdetected. CONCLUSION: We propose an efficient computerized method for the automatic measurement of the Selvester score in patients with the strict LBBB.


Assuntos
Algoritmos , Bloqueio de Ramo/diagnóstico , Eletrocardiografia/métodos , Sistema de Condução Cardíaco/fisiopatologia , Infarto do Miocárdio/diagnóstico , Miocárdio/patologia , Processamento de Sinais Assistido por Computador , Potenciais de Ação , Automação , Bloqueio de Ramo/patologia , Bloqueio de Ramo/fisiopatologia , Erros de Diagnóstico/prevenção & controle , Humanos , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
19.
Ann Noninvasive Electrocardiol ; 21(1): 49-59, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26806840

RESUMO

BACKGROUND: Increased QRS score and wide spatial QRS-T angle are independent predictors of cardiovascular mortality in the general population. Our main objective was to assess whether a QRS score ≥ 5 and/or QRS-T angle ≥ 105° enable screening of patients for myocardial scar features. METHODS: Seventy-seven patients of age ≤ 70 years with QRS score ≥ 5 and/or spatial QRS-T angle ≥ 105° as well as left ventricular ejection fraction (LVEF) >35% were enrolled in the study. All participants underwent complete clinical examination, signal-averaged ECG (SAECG), 30-minute ambulatory ECG recording for T-wave alternans (TWA), and late gadolinium enhancement cardiac magnetic resonance (LGE-CMR). Relationship between QRS score, QRS-T angle with scar presence and pattern, as well as gray zone, core, and total scar size by LGE-CMR were assessed. RESULTS: Myocardial scar was present in 41 (53%) patients, of whom 19 (46%) exhibited a typical ischemic pattern. QRS score but not QRS-T angle was related to total scar size and gray zone size (R(2) = 0.12, P = 0.002; R(2) = 0.17; P ≤ 0.0001, respectively). Patients with QRS scores ≥ 6 had significantly greater myocardial scar and gray zone size, increased QRS duration and QRS-T angle, a higher prevalence of late potentials (LPs) presence, increased LV end-diastolic volume and decreased LVEF. There was a significant independent and positive association between TWA value and total scar (P = 0.001) and gray zone size (P = 0.01). CONCLUSION: Patients with preserved LVEF and myocardial scar by CMR also have electrocardiographic features that could be involved in ventricular arrhythmogenesis.


Assuntos
Cicatriz/diagnóstico , Eletrocardiografia , Isquemia Miocárdica/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Programas de Rastreamento , Pessoa de Meia-Idade , Volume Sistólico , Adulto Jovem
20.
J Electrocardiol ; 49(6): 837-842, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27524478

RESUMO

Fourteen drugs were removed from the market worldwide because their potential to cause torsade de pointes (torsade), a potentially fatal ventricular arrhythmia. The observation that most drugs that cause torsade block the potassium channel encoded by the human ether-à-go-go related gene (hERG) and prolong the heart rate corrected QT interval (QTc) on the ECG, led to a focus on screening new drugs for their potential to block the hERG potassium channel and prolong QTc. This has been a successful strategy keeping torsadogenic drugs off the market, but has resulted in drugs being dropped from development, sometimes inappropriately. This is because not all drugs that block the hERG potassium channel and prolong QTc cause torsade, sometimes because they block other channels. The regulatory paradigm is evolving to improve proarrhythmic risk prediction. ECG studies can now use exposure-response modeling for assessing the effect of a drug on the QTc in small sample size first-in-human studies. Furthermore, the Comprehensive in vitro Proarrhythmia Assay (CiPA) initiative is developing and validating a new in vitro paradigm for cardiac safety evaluation of new drugs that provides a more accurate and comprehensive mechanistic-based assessment of proarrhythmic potential. Under CiPA, the prediction of proarrhythmic potential will come from in vitro ion channel assessments coupled with an in silico model of the human ventricular myocyte. The preclinical assessment will be checked with an assessment of human phase 1 ECG data to determine if there are unexpected ion channel effects in humans compared to preclinical ion channel data. While there is ongoing validation work, the heart rate corrected J-Tpeak interval is likely to be assessed under CiPA to detect inward current block in presence of hERG potassium channel block.


Assuntos
Cardiologia/normas , Eletrocardiografia/normas , Guias de Prática Clínica como Assunto , Vigilância de Produtos Comercializados/normas , Medição de Risco/normas , Torsades de Pointes/induzido quimicamente , Torsades de Pointes/diagnóstico , Humanos , Segurança do Paciente/normas , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA