Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Ann Surg Oncol ; 30(13): 8419-8427, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37605084

RESUMO

BACKGROUND: Near-infrared (NIR) fluorescence-guided surgery with indocyanine green (ICG) has been demonstrated to provide high sensitivity in sentinel lymph node biopsy (SLNB) for breast cancer but has several limitations, such as unstable pharmacokinetics, limited fluorescence brightness, and undesired diffusion to neighboring tissues. This paper investigates the use of Voluven® as the solvent for ICG fluorescence-guided SLNB (ICG-SLNB). METHODS: The photophysical properties of ICG in water and Voluven® were evaluated in laboratory experiments and in a mouse model. Nine patients with early breast cancer underwent subareolar injection of diluted ICG (0.25 mg/ml) for ICG-SLNB. Six of the nine patients received ICG dissolved in Voluven® (ICG:Voluven®), while three were administered ICG dissolved in water (ICG:water); a repetitive injection-observation protocol was followed for all patients. The mapping image quality was evaluated. RESULTS: Laboratory experiments and in vivo mouse study showed improved fluorescence and better targeting using Voluven® as the solvent. ICG-SLNB with a repetitive injection-observation protocol was successfully performed in all nine patients. ICG:Voluven® administration had an overall better signal-to-background ratio (SBR) in sequential sentinel lymph nodes. The rates of transportation within the lymphatics were also improved using ICG:Voluven® compared with ICG:water. CONCLUSIONS: From basic research to animal models to in-human trial, our study proposes a repetitive injection-observation technique with ICG:Voluven®, which is characterized by better transportation and more stable mapping quality for ICG-SLNB in breast cancer patients.


Assuntos
Neoplasias da Mama , Linfonodo Sentinela , Humanos , Animais , Camundongos , Feminino , Verde de Indocianina , Linfonodo Sentinela/patologia , Neoplasias da Mama/cirurgia , Fluorescência , Biópsia de Linfonodo Sentinela/métodos , Solventes , Água , Corantes , Linfonodos/patologia
3.
Chem Commun (Camb) ; 59(66): 9968-9971, 2023 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-37501643

RESUMO

We designed polymer dot-magnetic nanoparticle nanohybrids for signal enhancement in a test strip platform. Besides, the multicolor emissions of the Pdots embed multiplexing ability for this test strip. Two mycotoxins, aflatoxin B1 and zearalenone, were tested with the determined limits of detection of 2.15 ng mL-1 and 4.87 ng mL-1, respectively.


Assuntos
Nanopartículas de Magnetita , Micotoxinas , Zearalenona , Micotoxinas/análise , Polímeros , Imunoensaio , Limite de Detecção , Aflatoxina B1/análise , Contaminação de Alimentos/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA