Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 239
Filtrar
1.
Am Heart J ; 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38838970

RESUMO

BACKGROUND: The impact of prosthesis-patient mismatch (PPM) on major endpoints after transcatheter aortic valve replacement (TAVR) is controversial and the effects on progression of heart damage are poorly investigated. Therefore, our study aims to evaluate the prevalence and predictors of PPM in a "real world" cohort of patients at intermediate and low surgical risk, its impact on mortality and the clinical-echocardiographic progression of heart damage. METHODS: 963 patients who underwent TAVR procedure between 2017 and 2021, from the RECOVERY-TAVR international multicenter observational registry, were included in this analysis. Multiparametric echocardiographic data of these patients were analyzed at 1-year follow-up (FU). Clinical and echocardiographic features were stratified by presence of PPM and PPM severity, as per the most current international recommendations, using VARC-3 criteria. RESULTS: 18% of patients developed post-TAVR. PPM, and 7.7% of the whole cohort had severe PPM. At baseline, 50.3% of patients with PPM were male (vs 46.2% in the cohort without PPM, p=0.33), aged 82 (IQR 79-85y) years vs 82 (IQR 78-86 p=0.46), and 55.6% had Balloon-Expandable valves implanted (vs 46.8% of patients without PPM, p=0.04); they had smaller left ventricular outflow tract (LVOT) diameter (20 mm, IQR 19-21 vs 20 mm, IQR 20-22, p=0.02), reduced SVi (34.2 vs 38 ml/m2, p<0.01) and transaortic flow rate (190.6 vs 211 ml/s, p<0.01). At pre-discharge FU patients with PPM had more paravalvular aortic regurgitation (moderate-severe AR 15.8% vs 9.2%, p<0.01). At 1-year FU, maladaptive alterations of left ventricular parameters were found in patients with PPM, with a significant increase in end-systolic diameter (33 mm vs 28 mm, p=0.03) and a significant increase in left ventricle end systolic indexed volume in those with moderate and severe PPM (52 IQR 42-64 and 52, IQR 41-64 vs.44 IQR 35-59 in those without, p=0.02)). No evidence of a significant impact of PPM on overall (p=0.71) and CV (p=0.70) mortality was observed. Patients with moderate/severe PPM had worse NYHA functional class at 1 year (NYHA III-IV 13% vs 7.8%, p=0.03). Prosthesis size≤23 mm (OR 11.6, 1.68-80.1) was an independent predictor of PPM, while SVi (OR 0.87, 0.83-0.91, p<0.001) and LVOT diameter (OR 0.79, 0.65-0.95, p=0.01) had protective effect. CONCLUSIONS: PPM was observed in 18% of patients undergoing TAVR. Echocardiographic evaluations demonstrated a PPM-related pattern of early ventricular maladaptive alterations, possibly precursor to a reduction in cardiac function, associated with a significant deterioration in NYHA class at 1 year. These findings emphasize the importance of prevention of PPM of any grade in patients undergoing TAVR procedure, especially in populations at risk.

2.
Cardiovasc Diabetol ; 23(1): 52, 2024 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-38310281

RESUMO

BACKGROUND: The outcomes of percutaneous coronary intervention (PCI) in diabetic patients are still suboptimal, and it is unclear if diabetic patients might derive a benefit from the use of drug-coated balloons. AIMS: To evaluate the impact of diabetes mellitus on the outcomes of patients undergoing PCI with sirolimus-coated balloon (SCB) MagicTouch (Concept Medical, India). METHODS: We conducted a subgroup analysis of the prospective, multicenter, investigator-initiated EASTBOURNE registry, evaluating the performance of MagicTouch SCB in patients with and without diabetes. The study primary endpoint was target lesion revascularization (TLR) at 12-month follow-up. Secondary clinical endpoints were major adverse clinical events (MACE), death, myocardial infarction (MI), and BARC 2-5 bleedings. RESULTS: Among 2,083 enrolled patients, a total of 864 suffered from diabetes (41.5%). Patients with diabetes had a numerically higher occurrence of TLR (6.5% vs. 4.7% HR 1.38, 95%CI 0.91-2.08), all-cause death (3.8% vs. 2.6%, HR 1.81, 95%CI 0.95-3.46), and MACE (12.2% vs. 8.9%; HR 1.26 95%CI 0.92-1.74). The incidence of spontaneous MI was significantly higher among diabetic patients (3.4% vs. 1.5%, HR 2.15 95%CI 1.09-4.25); bleeding events did not significantly differ. The overall incidence of TLR was higher among in-stent restenosis (ISR) as compared to de-novo coronary lesions, irrespectively from diabetes status. CONCLUSIONS: In the EASTBOURNE DIABETES registry, diabetic patients treated with the MagicTouch SCB did not have a significant increase in TLR when compared to non-diabetic patients; moreover, diabetic status did not affect the study device performance in terms of TLR, in both de-novo lesions and ISR.


Assuntos
Doença da Artéria Coronariana , Reestenose Coronária , Diabetes Mellitus , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Sirolimo/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/etiologia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Diabetes Mellitus/induzido quimicamente , Sistema de Registros , Reestenose Coronária/epidemiologia , Reestenose Coronária/etiologia
3.
Catheter Cardiovasc Interv ; 103(1): 209-218, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37957842

RESUMO

BACKGROUND: Balloon post-dilation (BPD) is a widely adopted strategy to optimize acute results of TAVI, with a positive impact on both paravalvular leak and mean gradients. On the other hand, the inflation of the balloon inside prosthetic leaflets may damage them increasing the risk of structural valve deterioration (SVD). Furthermore, the impact of BPD on long-term clinical outcomes and valve hemodynamics is yet unknown. AIMS: To evaluate the impact of BPD on valve durability and long-term clinical outcomes in patients undergoing self-expanding transcatheter valve implantation (TAVI). METHODS: Echocardiographic and clinical data from the ClinicalService (a nation-based data repository and medical care project) were analyzed. Patients were divided into two groups, those who underwent BPD after TAVI and those who did not. Coprimary endpoints were all-cause death and SVD. Cumulative incidence functions for SVD were estimated. RESULTS: Among 1835 patients included in the study, 417 (22.7%) underwent BPD and 1418 (77.3%) did not undergo BPD. No statistically significant differences at 6-year follow-up were found between groups in terms of all-cause mortality (HR: 1.05, 95% CI: 0.9-1.22; p = 0.557) and SVD (2.1% vs. 1.4%, p = 0.381). In addition, BPD did not predispose to higher risk of cardiovascular death, myocardial infarction, valve thrombosis, and endocarditis at 6-year follow-up. CONCLUSIONS: BPD following TAVI with a self-expanding prosthesis does not seem to be associated with an increased risk of adverse clinical outcomes or SVD at 6-year follow-up.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Dilatação , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Desenho de Prótese
4.
Clin Infect Dis ; 76(6): 1003-1012, 2023 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-36331961

RESUMO

BACKGROUND: Echocardiography is the primary imaging modality for diagnosis of infective endocarditis (IE) in prosthetic valve endocarditis (PVE) including IE after transcatheter aortic valve implantation (TAVI). This study aimed to evaluate the characteristics and clinical outcomes of patients with absent compared with evident echocardiographic signs of TAVI-IE. METHODS: Patients with definite TAVI-IE derived from the Infectious Endocarditis after TAVI International Registry were investigated comparing those with absent and evident echocardiographic signs of IE defined as vegetation, abscess, pseudo-aneurysm, intracardiac fistula, or valvular perforation or aneurysm. RESULTS: Among 578 patients, 87 (15.1%) and 491 (84.9%) had absent (IE-neg) and evident (IE-pos) echocardiographic signs of IE, respectively. IE-neg were more often treated via a transfemoral access with a self-expanding device and had higher rates of peri-interventional complications (eg, stroke, major vascular complications) during the TAVI procedure (P < .05 for all). IE-neg had higher rates of IE caused by Staphylococcus aureus (33.7% vs 23.2%; P = .038) and enterococci (37.2% vs 23.8%; P = .009) but lower rates of coagulase-negative staphylococci (4.7% vs 20.0%, P = .001). IE-neg was associated with the same dismal prognosis for in-hospital mortality in a multivariate binary regression analysis (odds ratio: 1.51; 95% confidence interval [CI]: .55-4.12) as well as a for 1-year mortality in Cox regression analysis (hazard ratio: 1.10; 95% CI: .67-1.80). CONCLUSIONS: Even with negative echocardiographic imaging, patients who have undergone TAVI and presenting with positive blood cultures and symptoms of infection are a high-risk patient group having a reasonable suspicion of IE and the need for an early treatment initiation.


Assuntos
Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Incidência , Fatores de Risco , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/etiologia , Endocardite/diagnóstico por imagem , Endocardite/epidemiologia , Ecocardiografia
5.
Catheter Cardiovasc Interv ; 102(6): 1020-1033, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37855169

RESUMO

BACKGROUND: Diabetic patients are at higher risk of recurrent adverse events following percutaneous coronary intervention (PCI) than the nondiabetics. Despite the introduction of new generation drug-eluting stents, their efficacy in the diabetics is still limited. AIMS: To evaluate the efficacy of the Abluminus DES+ biodegradable polymer sirolimus-eluting stent in reducing neointimal hyperplasia in diabetic patients, compared to a durable polymer everolimus-eluting stent (DP-EES). METHODS: A total of 131 patients with diabetes and coronary artery disease were enrolled in six Italian centers and randomized in a 2:1 fashion to PCI with Abluminus DES+ or DP-EES: 85 were assigned to Abluminus DES+ and 46 to DP-EES. The primary endpoint was optimal coherence tomography (OCT)-derived neointimal volume at 9-12 months. Secondary endpoints included OCT-derived neointimal area, neointimal volume obstruction and adverse clinical events. RESULTS: The primary endpoint, neointimal volume, did not differ between Abluminus DES+ and DP-EES (29.11 ± 18.90 mm3 vs. 25.48 ± 17.04 mm3 , p = 0.40) at 9-12-month follow-up. This finding remained consistent after weighing for the sum of stents lengths (1.14 ± 0.68 mm3 vs. 0.99 ± 0.74 mm3 for Abluminus DES+ and DP-EES, respectively, p = 0.38). Similarly, other OCT-derived and clinical secondary endpoints did not significantly differ between the two groups. Rate of target lesion failure was high in both groups (21.2% for Abluminus DES+ and 19.6% for DP-EES). CONCLUSIONS: This preliminary study failed to demonstrate the superiority of the Abluminus DES+ over the DP-EES in diabetic patients in terms of neointimal proliferation.


Assuntos
Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Implantes Absorvíveis , Everolimo/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Sirolimo/efeitos adversos , Tomografia de Coerência Óptica , Resultado do Tratamento
6.
Circulation ; 143(2): 104-116, 2021 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-32975133

RESUMO

BACKGROUND: Mitral valve-in-valve (ViV) and valve-in-ring (ViR) are alternatives to surgical reoperation in patients with recurrent mitral valve failure after previous surgical valve repair or replacement. Our aim was to perform a large-scale analysis examining midterm outcomes after mitral ViV and ViR. METHODS: Patients undergoing mitral ViV and ViR were enrolled in the Valve-in-Valve International Data Registry. Cases were performed between March 2006 and March 2020. Clinical endpoints are reported according to the Mitral Valve Academic Research Consortium (MVARC) definitions. Significant residual mitral stenosis (MS) was defined as mean gradient ≥10 mm Hg and significant residual mitral regurgitation (MR) as ≥ moderate. RESULTS: A total of 1079 patients (857 ViV, 222 ViR; mean age 73.5±12.5 years; 40.8% male) from 90 centers were included. Median STS-PROM score 8.6%; median clinical follow-up 492 days (interquartile range, 76-996); median echocardiographic follow-up for patients that survived 1 year was 772.5 days (interquartile range, 510-1211.75). Four-year Kaplan-Meier survival rate was 62.5% in ViV versus 49.5% for ViR (P<0.001). Mean gradient across the mitral valve postprocedure was 5.7±2.8 mm Hg (≥5 mm Hg; 61.4% of patients). Significant residual MS occurred in 8.2% of the ViV and 12.0% of the ViR patients (P=0.09). Significant residual MR was more common in ViR patients (16.6% versus 3.1%; P<0.001) and was associated with lower survival at 4 years (35.1% versus 61.6%; P=0.02). The rates of Mitral Valve Academic Research Consortium-defined device success were low for both procedures (39.4% total; 32.0% ViR versus 41.3% ViV; P=0.01), mostly related to having postprocedural mean gradient ≥5 mm Hg. Correlates for residual MS were smaller true internal diameter, younger age, and larger body mass index. The only correlate for residual MR was ViR. Significant residual MS (subhazard ratio, 4.67; 95% CI, 1.74-12.56; P=0.002) and significant residual MR (subhazard ratio, 7.88; 95% CI, 2.88-21.53; P<0.001) were both independently associated with repeat mitral valve replacement. CONCLUSIONS: Significant residual MS and/or MR were not infrequent after mitral ViV and ViR procedures and were both associated with a need for repeat valve replacement. Strategies to improve postprocedural hemodynamics in mitral ViV and ViR should be further explored.


Assuntos
Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas/normas , Valva Mitral/cirurgia , Sistema de Registros , Reoperação/normas , Substituição da Valva Aórtica Transcateter/normas , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Próteses Valvulares Cardíacas/tendências , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/tendências , Humanos , Internacionalidade , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Reoperação/tendências , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/tendências
7.
Clin Infect Dis ; 75(4): 638-646, 2022 09 10.
Artigo em Inglês | MEDLINE | ID: mdl-34894124

RESUMO

BACKGROUND: Infective endocarditis (IE) following transcatheter aortic valve replacement (TAVR) has been associated with a dismal prognosis. However, scarce data exist on IE perivalvular extension (PEE) in such patients. METHODS: This multicenter study included 579 patients who had the diagnosis of definite IE at a median of 171 (53-421) days following TAVR. PEE was defined as the presence of an intracardiac abscess, pseudoaneurysm, or fistula. RESULTS: A total of 105 patients (18.1%) were diagnosed with PEE (perivalvular abscess, pseudoaneurysm, fistula, or a combination in 87, 7, 7, and 4 patients, respectively). A history of chronic kidney disease (adjusted odds ratio [ORadj], 2.08; 95% confidence interval [CI]: 1.27-3.41; P = .003) and IE secondary to coagulase-negative staphylococci (ORadj, 2.71; 95% CI: 1.57-4.69; P < .001) were associated with an increased risk of PEE. Surgery was performed at index IE episode in 34 patients (32.4%) with PEE (vs 15.2% in patients without PEE, P < .001). In-hospital and 2-year mortality rates among PEE-IE patients were 36.5% and 69.4%, respectively. Factors independently associated with an increased mortality were the occurrence of other complications (stroke post-TAVR, acute renal failure, septic shock) and the lack of surgery at index IE hospitalization (padj < 0.05 for all). CONCLUSIONS: PEE occurred in about one-fifth of IE post-TAVR patients, with the presence of coagulase-negative staphylococci and chronic kidney disease determining an increased risk. Patients with PEE-IE exhibited high early and late mortality rates, and surgery during IE hospitalization seemed to be associated with better outcomes.


Assuntos
Falso Aneurisma , Endocardite Bacteriana , Endocardite , Insuficiência Renal Crônica , Substituição da Valva Aórtica Transcateter , Abscesso , Falso Aneurisma/complicações , Falso Aneurisma/cirurgia , Coagulase , Endocardite/epidemiologia , Endocardite/etiologia , Endocardite/cirurgia , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/cirurgia , Humanos , Insuficiência Renal Crônica/complicações , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos
9.
Artigo em Inglês | MEDLINE | ID: mdl-36525378

RESUMO

OBJECTIVES: To explore the long-term clinical outcomes following intravascular lithotripsy (IVL) in calcified coronary lesions from a real-world population. BACKGROUND: IVL is a relatively new but promising modality for treating coronary calcified lesions, but there is a dearth of long-term outcome data from real-world patients. METHODS: This was a multicenter, observational study in which we enrolled all patients treated with IVL from November 2018 to February 2021 from eight centers in Europe and the United Kingdom. Procedural success, complications, and clinical outcomes (cardiac death, target vessel myocardial infarction [TVMI], target lesion revascularization [TLR], and MACE [major adverse cardiac events, the composite of cardiac death, TVMI, and TLR]) were assessed. RESULTS: In total, 273 patients with a mean age of 72 ± 9.1 years were treated with IVL. Major comorbidities included diabetes mellitus (n = 110, 40%) and chronic kidney disease (n = 45, 16%). Acute coronary syndrome accounted for 48% (n = 132) of patients, while 52% (n = 141) had stable angina. De novo lesions and in-stent restenosis accounted for 79% and 21% of cases, respectively. Intravascular imaging was used in 33% (n = 90) of patients. An upfront IVL strategy was adopted in 34% (n = 92), while the rest were bailout procedures. Adjuvant rotational atherectomy ("RotaTripsy") was required in 11% (n = 31) of cases. The procedural success was 99%. During a median follow-up of 687 days (interquartile range: 549-787), cardiac death occurred in 5% (n = 14), TVMI in 3% (n = 8), TLR in 6% (n = 16), and MACE rate was 11% (n = 30). CONCLUSION: This is the largest multicenter registry with a long-term follow-up showing the remarkably high procedural success of IVL use in calcified coronary lesions with low rates of hard endpoints and MACE.

10.
Catheter Cardiovasc Interv ; 99(4): 1277-1286, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34939726

RESUMO

OBJECTIVES: To evaluate the prognostic impact of baseline tricuspid annular plane systolic excursion/pulmonary artery systolic pressure (TAPSE/PASP) ratio, as an expression of the right ventricle-pulmonary artery (RV-PA) coupling, in patients with mitral regurgitation (MR) treated with the MitraClip. BACKGROUND: Impaired RV to PA coupling is considered a marker of RV dysfunction. METHODS: From February 2016 to February 2020, a total of 165 patients were evaluated and stratified in two groups according to a prespecified value of TAPSE/PASP ratio ≤ 0.36. RESULTS: The median patients' age was 79 (men: 62.4%). Sixty-three patients (38.1%) presented TAPSE/PASP ≤ 0.36 and were then compared with patients with TAPSE/PASP > 0.36. Functional MR etiology was more frequent in TAPSE/PASP ≤ 0.36 (71.4%; p = 0.046). Acute technical success was achieved in 92.7% of the population, without any significant difference between the two groups of study and with sustained results at 30-day (device success: 85.5%; procedural success: 84.8%). On multivariate Cox regression analysis, after correction for body mass index, chronic kidney disease and left ventricle ejection fraction ≥30% but <50%, TAPSE/PASP ≤ 0.36 remained a sustained predictor of mortality and hospitalization for heart failure at one year after MitraClip (hazard ratio: 3.87; 95% confidence interval: 1.83-8.22; p ≤ 0.001). Kaplan-Meier all-cause mortality and heart failure hospitalization rates at one year were consequently higher in patients with TAPSE/PASP ≤ 0.36 (39.4% vs. 14.8%; log-rank p ≤ 0.001). CONCLUSION: Baseline TAPSE/PASP ratio seems independently associated with all-cause mortality and heart failure hospitalization after MitraClip both in functional and degenerative MR.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Disfunção Ventricular Direita , Ventrículos do Coração , Humanos , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Prognóstico , Artéria Pulmonar/diagnóstico por imagem , Resultado do Tratamento , Função Ventricular Direita
11.
J Interv Cardiol ; 2022: 9609970, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35418809

RESUMO

Objectives: To investigate the safety and clinical efficacy of tirofiban during primary percutaneous coronary interventions (pPCI). Background: Gp IIb/IIIa inhibitors (GPI) use during pPCI has declined over years, mainly for the increased hemorrhagic risk associated to their use and for the availability of potent, fast-acting oral antiplatelet drugs. However, several pharmacodynamic studies showed suboptimal platelet inhibition with P2Y12-blockers, such as prasugrel or ticagrelor. Methods: Patients with ST-segment elevation myocardial infarction (STEMI) undergoing pPCI were prospectively enrolled in a multicenter registry conducted in high-volume centers in Italy. All patients received intraprocedural tirofiban. The primary safety endpoint was the occurrence of in-hospital bleedings according to the Bleeding Academic Research Consortium definition. In-hospital major adverse coronary events (MACE, defined as death, reinfarction, stent thrombosis, and target vessel revascularization), final TIMI flow, myocardial blush grade, and ST-segment resolution were also evaluated. Results: A total of 472 patients (mean age 61 ± 11 years, 83% males) were enrolled in 16 Italian centers from October 2015 to June 2018. Mean basal thrombus grade score was 3.47 ± 1.25. PCI was performed by transradial approach in 88% of patients. We observed a very low rate of 30 days BARC bleedings (2.1%) and MACE (0.8%). Complete (>70%) ST-segment resolution was observed in 67% of patients. Conclusions: In the FASTER registry, the use of tirofiban during primary PCI, performed with a transradial approach in most cases, in patients with high thrombus burden was associated with high rates of complete ST-segment resolution and low rates of in-hospital bleeding and MACE.


Assuntos
Intervenção Coronária Percutânea , Trombose , Idoso , Feminino , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária/efeitos adversos , Sistema de Registros , Reperfusão , Trombose/etiologia , Tirofibana/efeitos adversos , Resultado do Tratamento , Tirosina/efeitos adversos
12.
Clin Infect Dis ; 73(11): e3750-e3758, 2021 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-33733675

RESUMO

BACKGROUND: Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. METHODS: Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). RESULTS: Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; P = .12), but the rate of early IE was lower in the CC (2.29‰ vs 4.89‰, P < .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE ( CC: 67.7%; HC: 69.6%; P = .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; P = .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; P = .036) and in-hospital (26.6% vs 36.4%; P = .016) and 1-year (37.8% vs 53.5%; P < .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (P < .05 for all). CONCLUSIONS: Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time.


Assuntos
Endocardite Bacteriana , Endocardite , Substituição da Valva Aórtica Transcateter , Endocardite/epidemiologia , Endocardite/etiologia , Endocardite/cirurgia , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/cirurgia , Humanos , Incidência , Complicações Pós-Operatórias/epidemiologia , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 98(6): E847-E854, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-33960624

RESUMO

AIMS: The aim of this proof-of-concept study was to investigate safety and efficacy of a CT-scan based patient-specific algorithm to maximize coronary clearance and secondarily to achieve anatomically correct commissural alignment with the Acurate Neo device. METHOD AND RESULTS: A total of 45 consecutive patients undergoing TAVR with the Acurate Neo THV were prospectively enrolled in the study. Mean age was 81.6 ± 5.5 years, mean STS score was 6.1 ± 3.7. Device success rate was 100%. Aim of the technique was to rotationally deploy the TAVR device with a commissure lying on the bisector between the coronary ostia as calculated on the pre-procedural CT-scan. At post-TAVR CT-scan, coronary clearance was achieved in 98% of patients with no cases of severe coronary artery overlap. In 42 out of 45 patients, THV was aligned or, at most, mildly misaligned; there were 2 cases of moderate misalignment without any case of severe misalignment. Post-TAVR selective coronary artery engagement was attempted and succeeded in all patients (100%). CONCLUSION: Our CT-scan based patient-specific algorithm is safe and proven to be effective in avoiding coronary artery overlap and providing commissural alignment with Acurate Neo in all treated patients.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Resultado do Tratamento
14.
Catheter Cardiovasc Interv ; 98(1): E145-E152, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33155757

RESUMO

OBJECTIVE: This study sought to investigate the procedural and mid-term outcomes of transcatheter aortic valve implantation for failed surgical bioprostheses (TAVI-ViV) with Portico device. BACKGROUND: Limited evidence coming from early experience on Portico system does not allow to fully assess safety and efficacy of this device in this ViV patients. METHODS: From January 2016 up to June 2019, 56 consecutive patients undergoing TAVI-ViV with Portico were prospectively included in our institutional TAVI database. RESULTS: The prevalent mechanism of failure was stenosis (58.9%); true internal diameter (ID) was <21 mm in 71.4% of cases. Device success rate were 69.6% with 14 (25%) patients showing a residual gradient ≥20 mmHg, 2 (3.6%) a PVL ≥ moderate and 1 (1.8%) required a second THV implantation due to device embolization. At 1-year follow-up 5 patients (8.9%) died whereas moderate SVD was reported in 2 (3.6%). Patients with a post-procedural mean gradient ≥20 mmHg showed a significantly higher rate of CV hospitalization (21.4% vs. 2.4%, p = .02) whereas no differences in procedural and 1-year outcomes were noticed according to true ID diameter or degeneration mode. Chimney stenting (ChT) was performed in 23 (41%) patients without significant differences in procedural and 1-year outcomes compared to non-ChT group. CONCLUSIONS: TAVI-ViV with Portico valve was associated with good procedural and 1-year outcomes, even in patients with features of high procedural and anatomical complexity.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
15.
Catheter Cardiovasc Interv ; 97(1): E135-E145, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32400068

RESUMO

OBJECTIVES: To investigate paravalvular leak (PVL) and devices success rates according to aortic angle (AA) in patients undergoing transcatheter aortic valve implantation (TAVI) with three new-generation self-expanding devices. BACKGROUND: The impact of aortic angle (AA) on TAVI device success and PVL rates is controversial. METHODS: This retrospective study included 392 patients submitted to TAVI for severe aortic stenosis with Portico, Evolut-R and Acurate-NEO, and available AA measurements at computed tomography (CT) angiography. AA was calculated from the implantation projection and was defined as the angle between the plane of aortic annulus and an ideal horizontal plane. Aorta was defined horizontal if AA>57° (75th percentile). RESULTS: In the horizontal group, the rates of moderate/severe PVL was higher in the Evolut-R group (20.8%), which was also characterized by a lower implant compared to that of Acurate-NEO, whereas device success was comparable among the three devices. AA was a significant predictor of moderate/severe PVLs (AUC 0.72, p = .002) only in the Evolut-R population. On multivariate analysis, calcium volume 850HU, bicuspid aortic valve, and implantation depth at the level of left coronary cusp were independent predictors of moderate/severe PVL. On univariate analysis in the horizontal aorta population, implantation depth was confirmed among the most significant predictors of moderate/severe PVL. CONCLUSIONS: Despite comparable device success rates, horizontal aorta represented a technical challenge only in the Evolut-R subgroup, which showed higher rates of moderate/severe PVL than Portico and Acurate-NEO, and was associated with a low implant.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Aorta , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Complicações Pós-Operatórias , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
16.
Catheter Cardiovasc Interv ; 98(2): 225-235, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32936532

RESUMO

BACKGROUND: The recently introduced intravascular lithotripsy (IVL) appears promising and relatively safer than conventional approaches when dealing with calcified lesions. Although there are published reports on this novel technology, data from the real world are limited. In this study, we aim to report on the experience of IVL from a real-world population derived from six European centers that undertake high-volume complex coronary interventions. METHODS AND RESULTS: We enrolled all patients treated with IVL between November 2018 and February 2020 at six centers. Procedural success and complications were assessed along with clinical outcomes, which included: cardiac death, target vessel myocardial infarction (TVMI), target lesion revascularisation (TLR), and major adverse cardiac event (MACE) (composite of cardiac death, TVMI, and TLR). Hundred and ninety patients (200 lesions) with a mean age of 72 years were treated using IVL. Diabetes and chronic kidney disease were present in 50% (n = 95) and 16% (n = 30) of cases, respectively. Acute-coronary syndromes accounted for 91 (48%) of the cases. Most were de-novo lesions (77%; n = 154). Upfront use of IVL occurred in 26% of cases, while the rest were bail-out procedures due to inadequate predilatation with conventional balloons. Adjuvant rotational atherectomy was needed in 17% of cases. Procedural success was achieved in 99% of cases with a complication rate of 3%. During the median follow-up of 222 days, there was two cardiac deaths (1%), one case of TVMI (0.5%), 3 TLR (1.5%) taking the MACE rate to 2.6%. CONCLUSION: Use of IVL appears to be safe and effective in dealing with calcified-coronary lesions. A high success rate was observed with low procedural complications and event rates.


Assuntos
Aterectomia Coronária , Doença da Artéria Coronariana , Litotripsia , Calcificação Vascular , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Humanos , Litotripsia/efeitos adversos , Stents , Resultado do Tratamento , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia
17.
Catheter Cardiovasc Interv ; 98(4): 756-764, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33991385

RESUMO

OBJECTIVES: To evaluate outcome and its predictors of bioprosthetic valve fracture (BVF) in patients undergoing valve-in-valve transcatheter aortic valve replacement (VIV-TAVR). BACKGROUND: BVF is feasible and reduces transvalvular gradients in VIV-TAVR-procedures, but follow-up-data and information on factors influencing the outcome are missing. METHODS: The 81 cases of BVF-VIV-TAVR were collected from 14 international centers. RESULTS: Predominantly transcatheter heart valve (THV) was implanted first, followed by BVF. VARC-2 defined device success was 93%, most failures were attributed to residual high gradients. Mean gradients decreased from 37 ± 13 mmHg to 10.8 ± 5.9 mmHg (p < 0.001). BVF reduced the gradient by 16 mmHg. During follow-up (FU, 281 ± 164 days) mean gradient remained stable (10.8 ± 5.9 mmHg at discharge, 12.4 ± 6.3 mmHg at FU, p = ns). In-hospital major adverse events occurred in 3.7%. Event-free survival at 276 ± 237.6 days was 95.4%. The linear mixed model identified balloon-expandable valves (BEV), Mitroflow surgical valve, stenotic surgical bioprostheses and balloon only 1 mm larger than the true internal diameter of the surgical valve as predictors for higher gradients. CONCLUSIONS: BVF is safe and can significantly reduce gradients, which remain stable at FU. BEV, Mitroflow surgical valve, stenotic bioprostheses and balloon larger than the true internal diameter of the surgical valve of only 1 mm are predictors for higher final gradients.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Seguimentos , Hemodinâmica , Humanos , Desenho de Prótese , Falha de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
18.
Catheter Cardiovasc Interv ; 97(3): 411-420, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-32198845

RESUMO

OBJECTIVES: We aimed to evaluate the use of bare metal stent (BMS) implantation in current percutaneous coronary intervention (PCI) era, focusing on indications for use and clinical outcomes. BACKGROUND: Limited data on BMS usage in current clinical practice are available. METHODS: All patients who underwent PCI with at least one BMS implantation in 18 Italian centers from January 1, 2013 to December 31, 2017, were included in our registry. Rates of BMS use and reasons for BMS implantations were reported for the overall study period and for each year. Primary outcomes were mortality, bleeding (Bleeding Academic Research Consortium-BARC and Thrombolysis in Myocardial Infarction-TIMI non-CABG definitions), and major adverse cardiac events (MACE) defined as the composite of all-cause and cardiac death, any myocardial infarction, target vessel revascularization, or any stent thrombosis. RESULTS: Among 58,879 patients undergoing PCI in the study period, 2,117 (3.6%) patients (mean age 73 years, 69.7% males, 73.3% acute coronary syndrome) were treated with BMS implantation (2,353 treated lesions). The rate of BMS implantation progressively decreased from 10.1% (2013) to 0.3% (2017). Main reasons for BMS implantation were: ST-elevation myocardial infarction (STEMI) (23.1%), advanced age (24.4%), and physician's perception of high-bleeding risk (34.0%). At a mean follow-up of 2.2 ± 1.5 years, all-cause and cardiac mortality were 25.6 and 12.7%, respectively; MACE rate was 35.3%, any bleeding rate was 13.0% (BARC 3-5 bleeding 6.3%, TIMI non-CABG major bleeding 6.1%). CONCLUSION: In a large, contemporary, real-world, multicenter registry, BMS use progressively reduced over the last 5 years. Main reasons for BMS implantation were STEMI, advanced age, and physician's perception of high-bleeding risk. High rates of mortality and MACE were observed in this real-world high-risk population.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Feminino , Humanos , Itália , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Sistema de Registros , Stents , Resultado do Tratamento
19.
Echocardiography ; 38(11): 1913-1923, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34755379

RESUMO

BACKGROUND: Mitral valve (MV) repair with MitraClip system is a safe treatment option for high-risk patients with significant mitral regurgitation (MR). We aimed to characterize, by three-dimensional echocardiography (3D-E), changes occurring in MV after implantation of third generation MitraClip XTR device, with specific reference to the underlying MR mechanism (functional vs degenerative, FMR vs DMR). METHODS: We prospectively enrolled 59 patients, who underwent intra-procedural 3D-E before and after device deployment. Three-D datasets were analyzed off-line, using a dedicated semiautomatic software, to obtain parametric quantification of mitral anatomy. RESULTS: Post-procedural MR of mild or lesser degree was achieved in 40 patients (68%), with no differences between FMR and DMR (p 0.9). After MitraClip XTR implantation, the FMR group experienced an immediate annular resizing, with reduction of antero-posterior diameter (p 0.024) and sphericity index (p 0.017), next to a recovery of physiological saddle-shape, defined by lower non-planar angle (p ≤0.001) and higher annulus height to commissural width ratio (p ≤0.001). On the opposite, the DMR group revealed a significant decrease of maximum annular velocity (p 0.027), addressing a mechanic effect of the device deployment. Finally, baseline anterior mitral leaflet angle was found as an independent predictor of acute procedural result (OR 6.7, [CI 1.01-44.33], p 0.049). CONCLUSIONS: MitraClip XTR implantation acts in restoring the original mitral geometry, with distinctive effects according to MR mechanism. Three-D parametric quantification of MV sheds new light on changes occurring in the valvular apparatus, and helps identifying possible new predictors of acute procedural success.


Assuntos
Ecocardiografia Tridimensional , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Ecocardiografia Transesofagiana , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
20.
Eur Heart J ; 41(20): 1876-1886, 2020 05 21.
Artigo em Inglês | MEDLINE | ID: mdl-31904800

RESUMO

AIMS: In the last decade, transcatheter aortic valve (TAV) replacement determined a paradigm shift in the treatment of patients with severe symptomatic aortic stenosis. Data on long-term TAV performance are still limited. We sought to evaluate the clinical and haemodynamic outcomes of the CoreValve self-expandable valve up to 8-year follow-up (FU). METHODS AND RESULTS: Nine hundred and ninety inoperable or high-risk patients were treated with the CoreValve TAV in eight Italian Centres from June 2007 to December 2011. The median FU was 4.4 years (interquartile range 1.4-6.7 years). Longest FU reached 11 years. A total of 728 died within 8-year FU (78.3% mortality from Kaplan-Meier curve analysis). A significant functional improvement was observed in the majority of patients and maintained over time, with 79.3% of surviving patients still classified New York Heart Association class ≤ II at 8 years. Echocardiographic data showed that the mean transprosthetic aortic gradient remained substantially unchanged (9 ± 4 mmHg at discharge, 9 ± 5 mmHg at 8 years, P = 0.495). The rate of Grade 0/1 paravalvular leak was consistent during FU with no significant change from post-procedure to FU ≥5 years in paired analysis (P = 0.164). Structural valve deterioration (SVD) and late bioprosthetic valve failure (BVF) were defined according to a modification of the 2017 EAPCI/ESC/EACTS criteria. In cumulative incidence functions at 8 years, moderate and severe SVD were 3.0% [95% confidence interval (CI) 2.1-4.3%] and 1.6% (95% CI 0.6-3.9%), respectively, while late BVF was 2.5% (95% CI 1.2-5%). CONCLUSION: While TAVs are questioned about long-term performance and durability, the results of the present research provide reassuring 8-year evidence on the CoreValve first-generation self-expandable bioprosthesis.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA