Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Microsc ; 287(2): 81-92, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35638174

RESUMO

High-resolution X-ray microscopy (XRM) is gaining interest for biological investigations of extremely small-scale structures. XRM imaging of bones in living mice could provide new insights into the emergence and treatment of osteoporosis by observing osteocyte lacunae, which are holes in the bone of few micrometres in size. Imaging living animals at that resolution, however, is extremely challenging and requires very sophisticated data processing converting the raw XRM detector output into reconstructed images. This paper presents an open-source, differentiable reconstruction pipeline for XRM data which analytically computes the final image from the raw measurements. In contrast to most proprietary reconstruction software, it offers the user full control over each processing step and, additionally, makes the entire pipeline deep learning compatible by ensuring differentiability. This allows fitting trainable modules both before and after the actual reconstruction step in a purely data-driven way using the gradient-based optimizers of common deep learning frameworks. The value of such differentiability is demonstrated by calibrating the parameters of a simple cupping correction module operating on the raw projection images using only a self-supervisory quality metric based on the reconstructed volume and no further calibration measurements. The retrospective calibration directly improves image quality as it avoids cupping artefacts and decreases the difference in grey values between outer and inner bone by 68-94%. Furthermore, it makes the reconstruction process entirely independent of the XRM manufacturer and paves the way to explore modern deep learning reconstruction methods for arbitrary XRM and, potentially, other flat-panel computed tomography systems. This exemplifies how differentiable reconstruction can be leveraged in the context of XRM and, hence, is an important step towards the goal of reducing the resolution limit of in vivo bone imaging to the single micrometre domain.


Assuntos
Processamento de Imagem Assistida por Computador , Microscopia , Animais , Calibragem , Processamento de Imagem Assistida por Computador/métodos , Camundongos , Microscopia/métodos , Estudos Retrospectivos , Raios X
2.
Artigo em Inglês | MEDLINE | ID: mdl-38780830

RESUMO

PURPOSE: Intraoperative cone-beam CT imaging enables 3D validation of implant positioning and fracture reduction for orthopedic and trauma surgeries. However, the emergence of metal artifacts, especially in the vicinity of metallic objects, severely degrades the clinical value of the imaging modality. In previous works, metal artifact avoidance (MAA) methods have been shown to reduce metal artifacts by adapting the scanning trajectory. Yet, these methods fail to translate to clinical practice due to remaining methodological constraints and missing workflow integration. METHODS: In this work, we propose a method to compute the spatial distribution and calibrated strengths of expected artifacts for a given tilted circular trajectory. By visualizing this as an overlay changing with the C-Arm's tilt, we enable the clinician to interactively choose an optimal trajectory while factoring in the procedural context and clinical task. We then evaluate this method in a realistic human cadaver study and compare the achieved image quality to acquisitions optimized using global metrics. RESULTS: We assess the effectiveness of the compared methods by evaluation of image quality gradings of depicted pedicle screws. We find that both global metrics as well as the proposed visualization of artifact distribution enable a drastic improvement compared to standard non-tilted scans. Furthermore, the novel interactive visualization yields a significant improvement in subjective image quality compared to the state-of-the-art global metrics. Additionally we show that by formulating an imaging task, the proposed method allows to selectively optimize image quality and avoid artifacts in the region of interest. CONCLUSION: We propose a method to spatially resolve predicted artifacts and provide a calibrated measure for artifact strength grading. This interactive MAA method proved practical and effective in reducing metal artifacts in the conducted cadaver study. We believe this study serves as a crucial step toward clinical application of an MAA system to improve image quality and enhance the clinical validation of implant placement.

3.
Sci Rep ; 13(1): 5329, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-37005487

RESUMO

Nail psoriasis occurs in about every second psoriasis patient. Both, finger and toe nails can be affected and also severely destroyed. Furthermore, nail psoriasis is associated with a more severe course of the disease and the development of psoriatic arthritis. User independent quantification of nail psoriasis, however, is challenging due to the heterogeneous involvement of matrix and nail bed. For this purpose, the nail psoriasis severity index (NAPSI) has been developed. Experts grade pathological changes of each nail of the patient leading to a maximum score of 80 for all nails of the hands. Application in clinical practice, however, is not feasible due to the time-intensive manual grading process especially if more nails are involved. In this work we aimed to automatically quantify the modified NAPSI (mNAPSI) of patients using neuronal networks retrospectively. First, we performed photographs of the hands of patients with psoriasis, psoriatic arthritis, and rheumatoid arthritis. In a second step, we collected and annotated the mNAPSI scores of 1154 nail photos. Followingly, we extracted each nail automatically using an automatic key-point-detection system. The agreement among the three readers with a Cronbach's alpha of 94% was very high. With the nail images individually available, we trained a transformer-based neural network (BEiT) to predict the mNAPSI score. The network reached a good performance with an area-under-receiver-operator-curve of 88% and an area-under precision-recall-curve (PR-AUC) of 63%. We could compare the results with the human annotations and achieved a very high positive Pearson correlation of 90% by aggregating the predictions of the network on the test set to the patient-level. Lastly, we provided open access to the whole system enabling the use of the mNAPSI in clinical practice.


Assuntos
Artrite Psoriásica , Aprendizado Profundo , Doenças da Unha , Psoríase , Humanos , Artrite Psoriásica/patologia , Estudos Retrospectivos , Índice de Gravidade de Doença , Psoríase/patologia , Doenças da Unha/patologia , Unhas/patologia
4.
Phys Med Biol ; 68(20)2023 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-37779386

RESUMO

Objective.Incorporating computed tomography (CT) reconstruction operators into differentiable pipelines has proven beneficial in many applications. Such approaches usually focus on the projection data and keep the acquisition geometry fixed. However, precise knowledge of the acquisition geometry is essential for high quality reconstruction results. In this paper, the differentiable formulation of fan-beam CT reconstruction is extended to the acquisition geometry.Approach.The CT fan-beam reconstruction is analytically derived with respect to the acquisition geometry. This allows to propagate gradient information from a loss function on the reconstructed image into the geometry parameters. As a proof-of-concept experiment, this idea is applied to rigid motion compensation. The cost function is parameterized by a trained neural network which regresses an image quality metric from the motion-affected reconstruction alone.Main results.The algorithm improves the structural similarity index measure (SSIM) from 0.848 for the initial motion-affected reconstruction to 0.946 after compensation. It also generalizes to real fan-beam sinograms which are rebinned from a helical trajectory where the SSIM increases from 0.639 to 0.742.Significance.Using the proposed method, we are the first to optimize an autofocus-inspired algorithm based on analytical gradients. Next to motion compensation, we see further use cases of our differentiable method for scanner calibration or hybrid techniques employing deep models.


Assuntos
Redes Neurais de Computação , Tomografia Computadorizada por Raios X , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Calibragem , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada de Feixe Cônico , Artefatos
5.
Sci Rep ; 12(1): 17540, 2022 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-36266416

RESUMO

Low-dose computed tomography (CT) denoising algorithms aim to enable reduced patient dose in routine CT acquisitions while maintaining high image quality. Recently, deep learning (DL)-based methods were introduced, outperforming conventional denoising algorithms on this task due to their high model capacity. However, for the transition of DL-based denoising to clinical practice, these data-driven approaches must generalize robustly beyond the seen training data. We, therefore, propose a hybrid denoising approach consisting of a set of trainable joint bilateral filters (JBFs) combined with a convolutional DL-based denoising network to predict the guidance image. Our proposed denoising pipeline combines the high model capacity enabled by DL-based feature extraction with the reliability of the conventional JBF. The pipeline's ability to generalize is demonstrated by training on abdomen CT scans without metal implants and testing on abdomen scans with metal implants as well as on head CT data. When embedding RED-CNN/QAE, two well-established DL-based denoisers in our pipeline, the denoising performance is improved by 10%/82% (RMSE) and 3%/81% (PSNR) in regions containing metal and by 6%/78% (RMSE) and 2%/4% (PSNR) on head CT data, compared to the respective vanilla model. Concluding, the proposed trainable JBFs limit the error bound of deep neural networks to facilitate the applicability of DL-based denoisers in low-dose CT pipelines.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia Computadorizada por Raios X , Humanos , Processamento de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Redes Neurais de Computação , Algoritmos , Razão Sinal-Ruído
6.
Med Phys ; 49(8): 5107-5120, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35583171

RESUMO

BACKGROUND: Computed tomography (CT) is widely used as an imaging tool to visualize three-dimensional structures with expressive bone-soft tissue contrast. However, CT resolution can be severely degraded through low-dose acquisitions, highlighting the importance of effective denoising algorithms. PURPOSE: Most data-driven denoising techniques are based on deep neural networks, and therefore, contain hundreds of thousands of trainable parameters, making them incomprehensible and prone to prediction failures. Developing understandable and robust denoising algorithms achieving state-of-the-art performance helps to minimize radiation dose while maintaining data integrity. METHODS: This work presents an open-source CT denoising framework based on the idea of bilateral filtering. We propose a bilateral filter that can be incorporated into any deep learning pipeline and optimized in a purely data-driven way by calculating the gradient flow toward its hyperparameters and its input. Denoising in pure image-to-image pipelines and across different domains such as raw detector data and reconstructed volume, using a differentiable backprojection layer, is demonstrated. In contrast to other models, our bilateral filter layer consists of only four trainable parameters and constrains the applied operation to follow the traditional bilateral filter algorithm by design. RESULTS: Although only using three spatial parameters and one intensity range parameter per filter layer, the proposed denoising pipelines can compete with deep state-of-the-art denoising architectures with several hundred thousand parameters. Competitive denoising performance is achieved on x-ray microscope bone data and the 2016 Low Dose CT Grand Challenge data set. We report structural similarity index measures of 0.7094 and 0.9674 and peak signal-to-noise ratio values of 33.17 and 43.07 on the respective data sets. CONCLUSIONS: Due to the extremely low number of trainable parameters with well-defined effect, prediction reliance and data integrity is guaranteed at any time in the proposed pipelines, in contrast to most other deep learning-based denoising architectures.


Assuntos
Algoritmos , Tomografia Computadorizada por Raios X , Processamento de Imagem Assistida por Computador/métodos , Redes Neurais de Computação , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos
7.
Sci Rep ; 12(1): 22554, 2022 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-36581647

RESUMO

Historical documents contain essential information about the past, including places, people, or events. Many of these valuable cultural artifacts cannot be further examined due to aging or external influences, as they are too fragile to be opened or turned over, so their rich contents remain hidden. Terahertz (THz) imaging is a nondestructive 3D imaging technique that can be used to reveal the hidden contents without damaging the documents. As noise or imaging artifacts are predominantly present in reconstructed images processed by standard THz reconstruction algorithms, this work intends to improve THz image quality with deep learning. To overcome the data scarcity problem in training a supervised deep learning model, an unsupervised deep learning network (CycleGAN) is first applied to generate paired noisy THz images from clean images (clean images are generated by a handwriting generator). With such synthetic noisy-to-clean paired images, a supervised deep learning model using Pix2pixGAN is trained, which is effective to enhance real noisy THz images. After Pix2pixGAN denoising, 99% characters written on one-side of the Xuan paper can be clearly recognized, while 61% characters written on one-side of the standard paper are sufficiently recognized. The average perceptual indices of Pix2pixGAN processed images are 16.83, which is very close to the average perceptual index 16.19 of clean handwriting images. Our work has important value for THz-imaging-based nondestructive historical document analysis.

8.
Int J Comput Assist Radiol Surg ; 15(11): 1787-1796, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32840721

RESUMO

PURPOSE: During spinal fusion surgery, screws are placed close to critical nerves suggesting the need for highly accurate screw placement. Verifying screw placement on high-quality tomographic imaging is essential. C-arm cone-beam CT (CBCT) provides intraoperative 3D tomographic imaging which would allow for immediate verification and, if needed, revision. However, the reconstruction quality attainable with commercial CBCT devices is insufficient, predominantly due to severe metal artifacts in the presence of pedicle screws. These artifacts arise from a mismatch between the true physics of image formation and an idealized model thereof assumed during reconstruction. Prospectively acquiring views onto anatomy that are least affected by this mismatch can, therefore, improve reconstruction quality. METHODS: We propose to adjust the C-arm CBCT source trajectory during the scan to optimize reconstruction quality with respect to a certain task, i.e., verification of screw placement. Adjustments are performed on-the-fly using a convolutional neural network that regresses a quality index over all possible next views given the current X-ray image. Adjusting the CBCT trajectory to acquire the recommended views results in non-circular source orbits that avoid poor images, and thus, data inconsistencies. RESULTS: We demonstrate that convolutional neural networks trained on realistically simulated data are capable of predicting quality metrics that enable scene-specific adjustments of the CBCT source trajectory. Using both realistically simulated data as well as real CBCT acquisitions of a semianthropomorphic phantom, we show that tomographic reconstructions of the resulting scene-specific CBCT acquisitions exhibit improved image quality particularly in terms of metal artifacts. CONCLUSION: The proposed method is a step toward online patient-specific C-arm CBCT source trajectories that enable high-quality tomographic imaging in the operating room. Since the optimization objective is implicitly encoded in a neural network trained on large amounts of well-annotated projection images, the proposed approach overcomes the need for 3D information at run-time.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Processamento de Imagem Assistida por Computador/métodos , Redes Neurais de Computação , Fusão Vertebral/métodos , Coluna Vertebral/cirurgia , Cirurgia Assistida por Computador/métodos , Artefatos , Humanos , Parafusos Pediculares , Imagens de Fantasmas , Coluna Vertebral/diagnóstico por imagem
9.
IEEE Trans Med Robot Bionics ; 2(3): 437-446, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33763632

RESUMO

Femoroplasty is a proposed alternative therapeutic method for preventing osteoporotic hip fractures in the elderly. Previously developed navigation system for femoroplasty required the attachment of an external X-ray fiducial to the femur. We propose a fiducial-free 2D/3D registration pipeline using fluoroscopic images for robot-assisted femoroplasty. Intraoperative fluoroscopic images are taken from multiple views to perform registration of the femur and drilling/injection device. The proposed method was tested through comprehensive simulation and cadaveric studies. Performance was evaluated on the registration error of the femur and the drilling/injection device. In simulations, the proposed approach achieved a mean accuracy of 1.26±0.74 mm for the relative planned injection entry point; 0.63±0.21° and 0.17±0.19° for the femur injection path direction and device guide direction, respectively. In the cadaver studies, a mean error of 2.64 ± 1.10 mm was achieved between the planned entry point and the device guide tip. The biomechanical analysis showed that even with a 4 mm translational deviation from the optimal injection path, the yield load prior to fracture increased by 40.7%. This result suggests that the fiducial-less 2D/3D registration is sufficiently accurate to guide robot assisted femoroplasty.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA