Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 402
Filtrar
1.
J Card Fail ; 28(1): 71-82, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34474157

RESUMO

BACKGROUND: Durable mechanical circulatory support (MCS) therapy improves survival in patients with advanced heart failure. Knowledge regarding the outcomes experienced by patients with inflammatory cardiomyopathy (CM) who receive durable MCS therapy is limited. METHODS AND RESULTS: We compared patients with inflammatory CM with patients with idiopathic dilated CM enrolled in the STS-INTERMACS registry. Among 19,012 patients, 329 (1.7%) had inflammatory CM and 5978 had idiopathic dilated CM (31.4%). The patients with inflammatory CM were younger, more likely to be White, and women. These patients experienced more preoperative arrhythmias and higher use of temporary MCS. Patients with inflammatory CM had a higher rate of early adverse events (<3 months after device implant), including bleeding, arrhythmias, non-device-related infections, neurologic dysfunction, and respiratory failure. The rate of late adverse events (≥3 months) was similar in the 2 groups. Patients with inflammatory CM had a similar 1-year (80% vs 84%) and 2-year (72% vs 76%, P = .15) survival. Myocardial recovery resulting in device explant was more common among patients with inflammatory CM (5.5% vs 2.3%, P < .001). CONCLUSIONS: Patients with inflammatory CM who received durable MCS appear to have a similar survival compared with patients with idiopathic dilated CM despite a higher early adverse event burden. Our findings support the use of durable MCS in an inflammatory CM population.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Miocardite , Feminino , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Humanos , Miocardite/etiologia , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 99(3): 896-903, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34505737

RESUMO

OBJECTIVES: We sought to report details of the incidence, organisms, clinical course, and outcomes of prosthetic valve endocarditis (PVE) after transcatheter aortic valve replacement (TAVR) in low-risk patients. BACKGROUND: PVE remains a rare but devastating complication of aortic valve replacement. Data regarding PVE after TAVR in low-risk patients are lacking. METHODS: We performed a detailed review of all patients in the low-risk TAVR trials who underwent TAVR from 2016 to 2020 and were adjudicated to have definitive PVE by the independent Clinical Events Committee. RESULTS: We analyzed 396 low-risk patients who underwent TAVR (including 72 with bicuspid valves). PVE occurred in 11 patients at a median 379 days (210, 528) from TAVR. The incidence within the first 30 days was 0%; days 31-365, 1.5%; and after day 365, 2.8%. The most common organism identified was Streptococcus (n = 4/11). Early PVE (≤ 365 days) occurred in five patients, of whom three demonstrated evidence of embolic stroke and two underwent surgical aortic valve re-intervention. Late PVE (> 365 days) occurred in six patients, of whom thee demonstrated evidence of embolic stroke and only one underwent surgical aortic valve re-intervention. Of the six patients with evidence of embolic stroke, two died, two were discharged to rehabilitation, and two were discharged home with home care. CONCLUSIONS: PVE was infrequent following TAVR in low-risk patients but was associated with substantial morbidity and mortality. Embolic stroke complicated the majority of PVE cases, contributing to worse outcomes in these patients. Efforts must be undertaken to minimize PVE in TAVR.


Assuntos
Estenose da Valva Aórtica , Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Endocardite/etiologia , Endocardite Bacteriana/complicações , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/epidemiologia , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
Am Heart J ; 231: 25-31, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33091365

RESUMO

Transcatheter aortic valve replacement (TAVR) has evolved toward a minimalist approach, resulting in shorter hospital stays. Real-world trends of next-day discharge (NDD) TAVR are unknown. This study aimed to evaluate underlying trends and readmissions of NDD TAVR. METHODS: This study was derived from the Nationwide Readmissions Database from 2012 to 2016. International Classification of Diseases, Ninth and Tenth Revisions, codes were used to identify patients. Any discharge within 1 day of admission was identified as NDD. NDD TAVR trends over the years were analyzed, and any admissions within 30 days were considered readmissions. A hierarchical logistic regression model was used to identify predictors of readmission. RESULTS: Of 49,742 TAVR procedures, 3,104 were NDD. The percentage of NDD TAVR increased from 1.5% (46/3,051) in 2012 to 12.2% (2,393/19,613) in 2016. However, the 30-day readmission rate remained the same over the years (8.6%). The patients' mean age was 80.3 ±â€¯8.4 years. Major readmission causes were heart-failure exacerbation (16%), infections (9%), and procedural complications (8%). In 2016, there were significantly higher late conduction disorder and gastrointestinal bleeding readmission rates than in 2012-2015. Significant predictors of readmission were anemia, baseline conduction disease, cardiac arrhythmias, heart failure, chronic kidney disease, chronic obstructive pulmonary disease, neoplastic disorders, and discharge to facility. CONCLUSIONS: The percentage of NDD TAVR increased over the years; however, readmission rates remained the same, with a higher rate of conduction abnormality-related hospitalizations in 2016. Careful discharge planning that includes identification of baseline factors that predict readmission and knowledge of etiologies may further prevent 30-day readmissions.


Assuntos
Alta do Paciente/estatística & dados numéricos , Readmissão do Paciente/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Idoso de 80 Anos ou mais , Anemia/epidemiologia , Arritmias Cardíacas/epidemiologia , Bases de Dados Factuais/estatística & dados numéricos , Progressão da Doença , Feminino , Hemorragia Gastrointestinal/epidemiologia , Sistema de Condução Cardíaco , Insuficiência Cardíaca/epidemiologia , Humanos , Infecções/epidemiologia , Modelos Logísticos , Masculino , Alta do Paciente/tendências , Readmissão do Paciente/tendências , Complicações Pós-Operatórias/epidemiologia , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Insuficiência Renal Crônica/epidemiologia , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/tendências , Estados Unidos
4.
Am Heart J ; 237: 25-33, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33713618

RESUMO

BACKGROUND: Previous studies from the Low Risk TAVR (LRT) trial demonstrated that transcatheter aortic valve replacement (TAVR) is safe and feasible in low-risk patients, with excellent 30-day and 1-year outcomes. The objective of this study was to report clinical outcomes and the impact of 30-day hypoattenuated leaflet thickening (HALT) on structural valve deterioration (SVD) 2 years after TAVR. METHODS: The LRT trial was the first Food and Drug Administration-approved Investigational Device Exemption trial in the United States to evaluate the safety and feasibility of TAVR in low-risk patients with symptomatic severe tricuspid aortic stenosis (AS). Valve hemodynamics and SVD by echo were recorded 30 days, 1 year, and 2 years post-TAVR. RESULTS: The LRT trial enrolled 200 low-risk patients to receive TAVR. Their mean age was 73.6 years and 61.5% were men. At 2-year follow-up, the mortality rate was 4.2%; the cardiovascular death rate was 1.6%. The disabling stroke rate was 1.1%, permanent pacemaker implantation rate was 8.6%, and 4 patients (2.2%) presented with endocarditis (2 between years 1 and 2). Of the 14% of TAVR subjects who had evidence of HALT at 30 days, there was no impact on valve hemodynamics, endocarditis or stroke at 2 years. CONCLUSIONS: TAVR for low-risk patients with symptomatic severe tricuspid AS is safe at 2 years. The presence of HALT at 30 days did not impact the early hemodynamic improvements nor the durability of the valve structure.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Hemodinâmica/fisiologia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia , Estudos de Viabilidade , Feminino , Fluoroscopia , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 98(6): 1152-1158, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-33893757

RESUMO

Refractory angina is considered a devastating condition with limited medical and therapeutic options. The Neovasc Reducer device, when implanted in the coronary sinus, is designed to alleviate anginal symptoms. However, the available clinical data are sparse. The US Food and Drug Administration (FDA) assembled the Circulatory Systems Devices Panel to discuss the Reducer's safety and effectiveness. Because of the coronavirus disease 2019 pandemic, this meeting was held virtually. In this manuscript, we detail the deliberation and discussion among the circulatory panel members, including their final vote.


Assuntos
COVID-19 , Seio Coronário , Humanos , SARS-CoV-2 , Resultado do Tratamento , Estados Unidos , United States Food and Drug Administration
6.
Catheter Cardiovasc Interv ; 98(4): E494-E500, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34032363

RESUMO

BACKGROUND: Women with acute coronary syndrome (ACS) generally present with more comorbidities and experience worse clinical outcomes compared with males. However, it is unclear whether this represents genuine sex-related difference or stems from clinical, procedural and socioeconomic factors. METHODS: We analyzed consecutive patients undergoing percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI), non-STEMI or unstable angina at a single tertiary-care center. Exclusion criteria were unknown sex, age < 18 years and PCI with bare metal stent or without stent placement. The study population was stratified according to sex. The primary endpoint was major adverse cardiac and cerebrovascular events (MACCE) defined as the composite of death, spontaneous myocardial infarction, or stroke at 1 year. Secondary endpoints were individual components of MACCE, target vessel revascularization (TVR) and clinically significant bleeding. RESULTS: Of the 7362 patients included, 5031 (68.3%) were men and 2331 (31.7%) women. Women were older and presented with a higher burden of comorbidities while men had more complex coronary anatomy. The incidence of 1 year MACCE was significantly higher among women (8.0% versus 5.6%; p < 0.01) compared to men. Women also experienced a higher rate of bleeding (2.3% vs. 1.4%; p = 0.02) while there were no differences between groups in terms of TVR (8.1% vs. 7.8%; p-value = 0.83). Differences in outcomes were attenuated after multivariable adjustment. Findings were consistent across ACS subgroups. CONCLUSIONS: In a contemporary ACS population treated with drug-eluting stents, women experienced a higher crude rate of 1-year MACCE. This was no longer apparent after accounting for baseline imbalances.


Assuntos
Síndrome Coronariana Aguda , Stents Farmacológicos , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/cirurgia , Adolescente , Feminino , Humanos , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento
7.
Lancet ; 394(10209): 1629-1637, 2019 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-31570255

RESUMO

BACKGROUND: Near-infrared spectroscopy (NIRS) intravascular ultrasound imaging can detect lipid-rich plaques (LRPs). LRPs are associated with acute coronary syndromes or myocardial infarction, which can result in revascularisation or cardiac death. In this study, we aimed to establish the relationship between LRPs detected by NIRS-intravascular ultrasound imaging at unstented sites and subsequent coronary events from new culprit lesions. METHODS: In this prospective, cohort study (LRP), patients from 44 medical centres were enrolled in Italy, Latvia, Netherlands, Slovakia, UK, and the USA. Patients with suspected coronary artery disease who underwent cardiac catheterisation with possible ad hoc percutaneous coronary intervention were eligible to be enrolled. Enrolled patients underwent scanning of non-culprit segments using NIRS-intravascular ultrasound imaging. The study had two hierarchal primary hypotheses, patient and plaque, each testing the association between maximum 4 mm Lipid Core Burden Index (maxLCBI4mm) and non-culprit major adverse cardiovascular events (NC-MACE). Enrolled patients with large LRPs (≥250 maxLCBI4mm) and a randomly selected half of patients with small LRPs (<250 maxLCBI4mm) were followed up for 24 months. This study is registered with ClinicalTrials.gov, NCT02033694. FINDINGS: Between Feb 21, 2014, and March 30, 2016, 1563 patients were enrolled. NIRS-intravascular ultrasound device-related events were seen in six (0·4%) patients. 1271 patients (mean age 64 years, SD 10, 883 [69%] men, 388 [31%]women) with analysable maxLCBI4mm were allocated to follow-up. The 2-year cumulative incidence of NC-MACE was 9% (n=103). Both hierarchical primary hypotheses were met. On a patient level, the unadjusted hazard ratio (HR) for NC-MACE was 1·21 (95% CI 1·09-1·35; p=0·0004) for each 100-unit increase maxLCBI4mm) and adjusted HR 1·18 (1·05-1·32; p=0·0043). In patients with a maxLCBI4mm more than 400, the unadjusted HR for NC-MACE was 2·18 (1·48-3·22; p<0·0001) and adjusted HR was 1·89 (1·26-2·83; p=0·0021). At the plaque level, the unadjusted HR was 1·45 (1·30-1·60; p<0·0001) for each 100-unit increase in maxLCBI4mm. For segments with a maxLCBI4mm more than 400, the unadjusted HR for NC-MACE was 4·22 (2·39-7·45; p<0·0001) and adjusted HR was 3·39 (1·85-6·20; p<0·0001). INTERPRETATION: NIRS imaging of non-obstructive territories in patients undergoing cardiac catheterisation and possible percutaneous coronary intervention was safe and can aid in identifying patients and segments at higher risk for subsequent NC-MACE. NIRS-intravascular ultrasound imaging adds to the armamentarium as the first diagnostic tool able to detect vulnerable patients and plaques in clinical practice. FUNDING: Infraredx.


Assuntos
Síndrome Coronariana Aguda/etiologia , Placa Aterosclerótica/diagnóstico por imagem , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Ultrassonografia de Intervenção/métodos , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/cirurgia , Idoso , Cateterismo Cardíaco/métodos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Morte , Feminino , Humanos , Itália/epidemiologia , Letônia/epidemiologia , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/cirurgia , Países Baixos/epidemiologia , Intervenção Coronária Percutânea/métodos , Placa Aterosclerótica/complicações , Placa Aterosclerótica/patologia , Eslováquia/epidemiologia , Reino Unido/epidemiologia , Estados Unidos/epidemiologia
8.
Am Heart J ; 222: 112-120, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32028137

RESUMO

Following the December 2018 publication of a meta-analysis by Katsanos et al reporting higher rates of long-term mortality with the utilization of paclitaxel-related devices (balloons and stents) when compared to control in femoropopliteal arteries, the US Food and Drug Administration (FDA) issued a safety alert in January 2019 and further detailed the implications for future clinical use of these devices in March 2019. The FDA convened a public meeting of the Circulatory System Devices Panel of the Medical Devices Advisory Committee in June 2019. This report summarizes the proceedings of this meeting and the panel's response to the 12 questions posed by the FDA related to the potentially increased late mortality of drug-coated balloons and drug-eluting stents with paclitaxel in patients with peripheral arterial disease.


Assuntos
Angioplastia com Balão/métodos , Materiais Revestidos Biocompatíveis , Paclitaxel/farmacologia , Doença Arterial Periférica/cirurgia , Stents , Antineoplásicos Fitogênicos/farmacologia , Congressos como Assunto , Humanos , Desenho de Prótese , Estados Unidos , United States Food and Drug Administration
9.
Am Heart J ; 221: 74-83, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31951847

RESUMO

BACKGROUND: Clinical data support the use of intravascular ultrasound (IVUS)-guided percutaneous coronary intervention (PCI) as being associated with improved outcomes. Nonetheless, global utilization of IVUS remains low. We hypothesize that, in the revascularization of complex lesions, IVUS use is associated with improved outcomes. METHODS: All patients with complex lesions treated with PCI at a single center from 2003 to 2016 were stratified by use of IVUS. Complex lesions were defined as follows: American College of Cardiology/American Heart Association type C lesions, in-stent restenosis, long lesions, bifurcations, severe calcification, left main lesions, and chronic total occlusions. The primary end point was the rate of major adverse cardiac events (MACE) at 1-year follow-up, defined as the composite of all-cause mortality, Q-wave myocardial infarction, and target vessel revascularization. Inverse probability weighting was used in the adjusted analysis. RESULTS: A total of 6,855 patients were included in the final analysis, of whom 67.3% had IVUS and 32.7% had angiography alone. The primary end point occurred in 13.4% of patients treated with IVUS and 18.3% of patients treated with angiography alone (P < .001). Inverse probability weighting-adjusted 1-year MACE rates demonstrated significant reduction with IVUS for each complex lesion type. CONCLUSIONS: Among patients with complex lesions, the use of IVUS was associated with lower MACE 1 year after PCI than angiography alone was. Because of the increased procedural risk in complex lesions, routine utilization of IVUS-guided PCI should be considered in this subset of patients.


Assuntos
Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea/métodos , Ultrassonografia de Intervenção/métodos , Idoso , Aterectomia Coronária , Angiografia Coronária , Stents Farmacológicos , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Mortalidade , Infarto do Miocárdio/epidemiologia , Revascularização Miocárdica/estatística & dados numéricos , Stents , Cirurgia Assistida por Computador/métodos
10.
Am Heart J ; 228: 65-71, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32866927

RESUMO

Intravascular ultrasound (IVUS)-guided percutaneous coronary intervention (PCI) has been shown in clinical trials, registries, and meta-analyses to reduce recurrent major adverse cardiovascular events after PCI. However, IVUS utilization remains low. An increasing number of high-risk or complex coronary artery lesions are treated with PCI, and we hypothesize that the impact of IVUS in guiding treatment of these complex lesions will be of increased importance in reducing major adverse cardiovascular events while remaining cost-effective. The "IMPact on Revascularization Outcomes of intraVascular ultrasound-guided treatment of complex lesions and Economic impact" trial (registered on clinicaltrials.gov: NCT04221815) is a multicenter, international, clinical trial randomizing subjects to IVUS-guided versus angiography-guided PCI in a 1:1 ratio. Patients undergoing PCI involving a complex lesion are eligible for enrollment. Complex lesion is defined as involving at least 1 of the following characteristics: chronic total occlusion, in-stent restenosis, severe coronary artery calcification, long lesion (≥28 mm), or bifurcation lesion. The clinical investigation will be conducted at approximately 120 centers in North America and Europe, enrolling approximately 2,500 to 3,100 randomized subjects with an adaptive design. The primary clinical end point is the rate of target vessel failure at 12 months, defined as the composite of cardiac death, target vessel-related myocardial infarction, and ischemia-driven target vessel revascularization. The co-primary imaging end point is the final post-PCI minimum stent area assessed by IVUS. The primary objective of this study is to assess the impact of IVUS guidance on the PCI treatment of complex lesions.


Assuntos
Doença da Artéria Coronariana , Vasos Coronários/diagnóstico por imagem , Intervenção Coronária Percutânea , Complicações Pós-Operatórias , Risco Ajustado/métodos , Ultrassonografia de Intervenção , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/prevenção & controle , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Cirurgia Assistida por Computador/métodos , Ultrassonografia de Intervenção/economia , Ultrassonografia de Intervenção/métodos
11.
Catheter Cardiovasc Interv ; 93(4): 620-625, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30280475

RESUMO

OBJECTIVES: To compare coronary revascularization appropriateness for non-acute coronary syndrome cases under the 2017 update vs the 2012 appropriate use criteria (AUC). BACKGROUND: In 2017, the 2012 AUC for coronary revascularization were updated. We examined how applying these new 2017 updates to our previous inappropriate cases would change their appropriateness. METHODS: We identified 50 cases of patients who underwent coronary revascularization for stable ischemic heart disease who were deemed inappropriate under the 2012 AUC. Two separate physicians reviewed the cases and applied a new AUC based on the 2017 AUC. Next, if there was a change, the reason was identified. RESULTS: Average age was 64, majority being male (29; 58%). Forty-two (84%) were asymptomatic upon presentation. Most cases (27, 54%) dealt with percutaneous coronary intervention (PCI) of the right coronary artery. After applying the 2017 AUC, 34 of the 50 inappropriate failures (68%) would be changed from "inappropriate" to "may be appropriate care." Of the 34 cases, 25 (73.5%) were changed due to the new AUC no longer expecting the patient to be on ≥2 anti-angina medications prior to PCI. Of the 34 cases, eight (23.5%) were changed due to the new AUC expanding the use of non-invasive modalities. CONCLUSIONS: Applying the 2017 AUC led to a statistically higher number of cases being deemed "may be appropriate." The most common cause for the change included the change in requirement for anti-angina regimen and the expanded role of non-invasive modalities.


Assuntos
Tomada de Decisão Clínica , Definição da Elegibilidade/normas , Fidelidade a Diretrizes/normas , Isquemia Miocárdica/terapia , Seleção de Pacientes , Intervenção Coronária Percutânea/normas , Guias de Prática Clínica como Assunto/normas , Padrões de Prática Médica/normas , Idoso , Técnicas de Apoio para a Decisão , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Intervenção Coronária Percutânea/efeitos adversos , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco
12.
Catheter Cardiovasc Interv ; 94(1): 157-164, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-30985082

RESUMO

OBJECTIVES: To assess the commonly reported complications and failure modes for FilterWire EZ Embolic Protection Devices (EPD) by analyzing the postmarketing surveillance data from the Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) database. BACKGROUND: EPDs prevent distal embolization of atheroembolic materials during percutaneous interventions resulting in reduced microvascular obstruction and improved microcirculation while maintaining tissue perfusion. The FilterWire EZ EPD (Boston Scientific, Natick, MA) is approved for use in interventions of de novo saphenous vein grafts (SVG) and carotid artery stenosis. Robust data on the commonly reported complications and failure modes associated with the FilterWire EZ device are limited. METHODS: The MAUDE database was queried from September 1, 2008, through September 30, 2018, for FilterWire EZ system, yielding 474 reports. After exclusion of duplicate and incomplete reports, 464 device reports were included in the final analysis. RESULTS: Device-related adverse events were most commonly reported for carotid (n = 281) and SVG (n = 101) interventions. The most commonly reported major complications were: ischemic stroke (n = 57), vessel perforation or dissection (n = 12), death (n = 8), and myocardial infarction (n = 5). Minor complications included: hypotension (n = 68), bradycardia (n = 41), and vasospasm (n = 27). The most commonly reported failure modes were: detachment and/or damage of the device components (n = 118), device entrapment (n = 90), and stent-related issues (n = 46). CONCLUSIONS: Analysis of the MAUDE dataset is helpful in identifying the commonly reported adverse events and failure modes of FilterWire EZ devices. This platform serves as an important tool for both physicians and manufacturers to optimize device performance and clinical outcomes.


Assuntos
Estenose das Carótidas/terapia , Transtornos Cerebrovasculares/etiologia , Dispositivos de Proteção Embólica , Embolia/prevenção & controle , Procedimentos Endovasculares/instrumentação , Oclusão de Enxerto Vascular/terapia , Cardiopatias/etiologia , Vigilância de Produtos Comercializados , Falha de Prótese , Veia Safena/transplante , United States Food and Drug Administration , Estenose das Carótidas/diagnóstico por imagem , Ponte de Artéria Coronária/efeitos adversos , Bases de Dados Factuais , Embolia/etiologia , Procedimentos Endovasculares/efeitos adversos , Análise de Falha de Equipamento , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Humanos , Desenho de Prótese , Fatores de Risco , Veia Safena/diagnóstico por imagem , Estados Unidos
13.
Catheter Cardiovasc Interv ; 93(4): 707-712, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30280469

RESUMO

OBJECTIVES: The aim of this study was to determine the prognostic value of contractile reserve (CR) at baseline in patients with low-flow, low-gradient severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: Patients with severe AS, left ventricular dysfunction, and low transaortic gradient are at high risk for mortality during surgical aortic valve replacement (SAVR). Furthermore, patients without CR have been shown to have perioperative mortality comparable to that of patients treated medically for severe AS. METHODS: We retrospectively analyzed patients who underwent TAVR with a diagnosis of low-gradient severe AS (mean transvalvular aortic gradient < 40 mmHg, LVEF < 50%, and AVA ≤ 1.0 cm2 or AVAi ≤ 0.6 cm2 ) and who had a pre-TAVR dobutamine stress echocardiogram (DSE). Patients were stratified by the presence or absence of CR, defined as an increase in stroke volume ≥ 20% during DSE. RESULTS: From 2008 to 2016, 61 patients with low-gradient severe AS underwent TAVR and had pre-TAVR DSE. CR was present in 31 patients (51%) and absent in 30 (49%). There was no significant difference between the two groups in baseline demographics, medical history, access site, or types of valves. All-cause mortality was similar in both groups at 30 days (13% with CR vs 10% without CR, P = 1.00) and 1 year (29% with CR vs 33% without CR, HR 1.20, 95% CI 0.49-2.96, P = 0.69). CONCLUSION: In patients with low-flow, low-gradient severe AS undergoing TAVR, the presence or absence of CR does not predict all-cause mortality at 30 days or 1 year.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Hemodinâmica , Contração Miocárdica , Substituição da Valva Aórtica Transcateter/mortalidade , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Bases de Dados Factuais , Feminino , Humanos , Masculino , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Volume Sistólico , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/mortalidade
14.
Am Heart J ; 196: 74-81, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29421017

RESUMO

BACKGROUND: Clinical indications for transcatheter aortic valve replacement (TAVR) and elements of the implantation procedure, including delivery system miniaturization and novel access options, have evolved over time. The reasons patients are excluded from TAVR also have changed. The impact of these changes on patient referral for and exclusion from TAVR is unknown. METHODS: We retrospectively analyzed patients referred to our center for TAVR from January 2010 to August 2016 to evaluate reasons for patient exclusion. Patients were divided into three groups based on initial screening date for trends in demographics and exclusion: Group 1, 2010-2012; Group 2, 2012-2014; Group 3, 2014 to August 1, 2016. Annual trends for patient exclusion from TAVR were assessed. RESULTS: One thousand nine hundred fifty-three patients were referred and underwent screening for TAVR. The rates at which patients were referred for TAVR were 23.8, 25.9, and 24.5 per month in groups 1, 2, and 3, respectively. Rate of patient exclusion from TAVR decreased from 68% in Group 1 to 38% in Group 3 (P < .001). The largest percentage of patients (29.4%) were initially excluded from TAVR for cardiac reasons, but this trend has decreased over time. Twenty-five percent are excluded for lack of procedural indication. Exclusion from TAVR for vascular access reasons decreased from 7.9% in 2010 to 1.0% in 2016 (P = .017). CONCLUSIONS: Referral numbers have been robust since TAVR became available. The percentage of patients excluded from TAVR has decreased over time. Patients are most commonly excluded from TAVR for concomitant coronary artery disease (CAD), asymptomatic severe AS, moderate AS, or non-cardiac critical illness. Patients with CAD and those with asymptomatic severe AS or moderate AS should be a focus for continued research in TAVR.


Assuntos
Estenose da Valva Aórtica/cirurgia , Hospitais com Alto Volume de Atendimentos/tendências , Seleção de Pacientes , Encaminhamento e Consulta/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estudos de Coortes , Feminino , Humanos , Masculino , Prognóstico , Estudos Retrospectivos , Medição de Risco , Análise de Sobrevida , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Estados Unidos
15.
Am Heart J ; 200: 11-16, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29898837

RESUMO

BACKGROUND: The impact of frailty assessment on outcomes in patients undergoing transcatheter aortic valve replacement (TAVR) remains unclear. Our aim was to evaluate the individual effect of each frailty test and the utility of an additive frailty index score on short- and long-term survival following TAVR. METHODS: Retrospective analysis of consecutive TAVR patients for whom a complete set of frailty tests was obtained: algorithm defined grip strength and 5-m walking tests, body mass index <20 kg/m2, Katz activities of daily living ≤4/6, serum albumin <3.5 g/dL. Frailty status was defined as having 3 or more positive frailty tests. Included were 498 patients with a mean age of 82±8 years. RESULTS: Frailty status, observed in 266 (53%) patients, was associated with both 30-day and 1-year mortality (6% vs. 2%, P=.016; 20% vs. 9%, P<.001; within the respective frailty groups). As compared to 0-2 frailty criteria, a higher frailty index score was associated with increased risk of death at 1 year (OR 2.23; 95% CI 1.14-4.34; P=.019 and OR 3.30; 95% CI 1.36-8.00; P=.008 for 3 and 4-5 frailty criteria met, respectively). In Cox regression analysis, frailty status was correlated with 1-year mortality (HR=2.2; 95%CI 1.25-3.96; P=.007), and a higher frailty index was associated with increased mortality risk (HR=2.0; 95% CI 1.08-3.7; P=.027; and HR=3.07; 95% CI 1.4-6.7; P=.005; for any 3, and 4-5 frailty criteria, respectively). CONCLUSIONS: Frailty status and a higher frailty index score were associated with increased 1-year mortality risk following TAVR.


Assuntos
Fragilidade/diagnóstico , Avaliação Geriátrica/métodos , Medição de Risco/métodos , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Índice de Massa Corporal , Feminino , Força da Mão , Humanos , Masculino , Mortalidade , Cuidados Pré-Operatórios/métodos , Projetos de Pesquisa , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Estados Unidos/epidemiologia , Teste de Caminhada/métodos
16.
Catheter Cardiovasc Interv ; 92(5): 964-971, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-30019839

RESUMO

OBJECTIVES: We aimed to evaluate the true extent of alternate access in a contemporary cohort of transcatheter aortic valve replacement (TAVR) patients. BACKGROUND: Appropriate access selection for TAVR impacts clinical outcomes. Despite device miniaturization, some patients remain ineligible for transfemoral arterial access. METHODS: Five hundred seventy-five consecutive TAVR patients were classified according to iliofemoral artery diameters measured by computed tomography (<5.0 mm, 5.0-5.4 mm, 5.5-5.9 mm, or ≥6 mm) and need for alternate access rate was estimated according to commercially available transcatheter heart valve Instructions For Use (IFU). RESULTS: Based on iliofemoral artery diameters alone, 11.5% of patients were predicted to require alternate access. After patient-level adjustment for the size of the planned THV and severe tortuosity or severe calcification, 14.9% and 20.8% of patients, respectively were predicted to require alternate access. Overall, 87.8% of patients underwent transfemoral TAVR and 12.3% underwent alternate access. There was no difference in the rate of major vascular complications and life threatening or major bleeding between groups, but transfusion rate was higher in smaller vessel groups. CONCLUSIONS: Despite device miniaturization, a substantial minority of contemporary TAVR patients still require alternate access. Most are eligible for newer extrathoracic approaches including transcaval, subclavian, and transcarotid that avoid the morbidity of transthoracic access.


Assuntos
Valva Aórtica/cirurgia , Cateterismo Periférico/métodos , Artéria Femoral , Doença Arterial Periférica/complicações , Substituição da Valva Aórtica Transcateter/métodos , Calcificação Vascular/complicações , Idoso , Idoso de 80 Anos ou mais , Cateteres Cardíacos , Cateterismo Periférico/efeitos adversos , Tomada de Decisão Clínica , Angiografia por Tomografia Computadorizada , Feminino , Artéria Femoral/diagnóstico por imagem , Próteses Valvulares Cardíacas , Humanos , Masculino , Miniaturização , Seleção de Pacientes , Doença Arterial Periférica/diagnóstico por imagem , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Calcificação Vascular/diagnóstico por imagem
18.
Am Heart J ; 189: 103-109, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28625366

RESUMO

BACKGROUND: Safety and effectiveness of transcatheter aortic valve replacement (TAVR) in low-risk patients with symptomatic severe aortic stenosis have not yet been established. HYPOTHESIS: Transcatheter aortic valve replacement is feasible in patients with symptomatic severe aortic stenosis and low risk for surgical aortic valve replacement. DESIGN: The LRT study is the first US Food and Drug Administration-approved Investigational Device Exemption prospective multicenter feasibility trial of TAVR in low-risk patients. Patients determined to be low risk by the Heart Team will be enrolled to undergo TAVR with a commercially available balloon-expandable or self-expandable device. A propensity score-matched, site-specific cohort of historical surgical aortic valve replacement patients will serve as a control group treated during the site's enrollment period or within the prior 3 years. Low-risk patients with symptomatic bicuspid aortic stenosis undergoing TAVR will be enrolled into a separate registry arm. All TAVR patients will undergo 4-dimensional contrast-enhanced cardiac computed tomography 4-6 weeks after implantation to assess for subclinical leaflet thrombosis and will be followed up clinically for 5 years with yearly echocardiography to monitor prosthesis function. SUMMARY: The LRT study will test feasibility of TAVR in low-risk patients with symptomatic severe aortic stenosis in the United States with either tricuspid or bicuspid native aortic valves. Enrollment commenced in 2016 and results are expected in 2018.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Estenose da Valva Aórtica/diagnóstico , Ecocardiografia , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Fatores de Risco , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X , Resultado do Tratamento
19.
Am Heart J ; 192: 98-104, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28938968

RESUMO

BACKGROUND: It has been hypothesized that the outcome post-PCI could be improved by the detection and subsequent treatment of vulnerable patients and lipid-rich vulnerable coronary plaques (LRP). A near-infrared spectroscopy (NIRS) catheter capable of detecting LRP is being evaluated in The Lipid-Rich Plaque Study. STUDY DESIGN: The LRP Study is an international, multicenter, prospective cohort study conducted in patients with suspected coronary artery disease (CAD) who underwent cardiac catheterization with possible ad hoc PCI for an index event. Patient level and plaque level events were detected by follow-up in the subsequent 2 years. Enrollment began in February 2014 and was completed in March 2016; a total of 1,562 patients were enrolled. Adjudication of new coronary event occurrence and de novo culprit lesion location during the 2-year follow-up is performed by an independent clinical end-points committee (CEC) blinded to NIRS-IVUS findings. The first analysis of the results will be performed when at least 20 de novo events have occurred for which follow-up angiographic data and baseline NIRS-IVUS measurements are available. It is expected that results of the study will be announced in 2018. SUMMARY: The LRP Study will test the hypotheses that NIRS-IVUS imaging to detect LRP in patients can identify vulnerable patients and vulnerable plaques. Identification of vulnerable patients will assist future studies of novel systemic therapies; identification of localized vulnerable plaques would enhance future studies of possible preventive measures.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Lipídeos/análise , Estudos Multicêntricos como Assunto/métodos , Placa Aterosclerótica/diagnóstico , Ensaios Clínicos Controlados Aleatórios como Assunto/métodos , Doença da Artéria Coronariana/metabolismo , Humanos , Placa Aterosclerótica/metabolismo , Estudos Prospectivos , Espectroscopia de Luz Próxima ao Infravermelho
20.
Am Heart J ; 184: 141-147, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-28224928

RESUMO

BACKGROUND: Right ventricular (RV) dysfunction was shown to be associated with adverse outcomes in a variety of cardiac patients and is considered a risk factor for adverse outcome according to the updated Valve Academic Research Consortium criteria. OBJECTIVE: Our goal was to assess the impact of RV function at baseline on 1-year mortality among patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR). METHODS: All patients with severe AS treated with TAVR from May 2007 to March 2015 at our center were included in the present study, and baseline and procedural characteristics were recorded for each patient. The patients were categorized according to RV function at baseline as assessed by current guidelines, and a comparison of mortality rates up to 1 year was performed. RESULTS: Among 650 patients, 606 had adequate echocardiogram quality and 146 (24%) had RV dysfunction. There were significant differences between the 2 groups, as patients with RV dysfunction were younger (81±9 vs 84±7 years, P=.01) and were more likely to be male (65% vs 42%, P<.001). In addition, patients with RV dysfunction had higher rates of prior myocardial infarction (26% vs 16%, P=.02) and atrial fibrillation (51% vs 39%, P=.02). Echocardiographic parameters demonstrated higher rates of left ventricular ejection fraction <40% (40% vs 18%, P<.001), tricuspid regurgitation above moderate (16% vs 9%, P=.04), and higher pulmonary artery systolic pressure (50±17 vs 44±16 mm Hg, P<.001) among patients with severe AS and RV dysfunction compared with patients with normal RV function. Despite the unfavorable cardiac function, patients with severe AS undergoing TAVR have similar functional class (P=.22) and mortality rates at 1year (27% vs 23%, log-rank P=.45). CONCLUSIONS: Patients with severe AS and RV dysfunction have similar 1-year mortality and functional class after TAVR to patients with normal RV function. The presence of RV dysfunction does not correlate with outcome in patients with severe AS.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Disfunção Ventricular Direita/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Ecocardiografia , Feminino , Humanos , Masculino , Mortalidade , Prognóstico , Estudos Prospectivos , Volume Sistólico , Resultado do Tratamento , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/fisiopatologia , Disfunção Ventricular Direita/complicações , Disfunção Ventricular Direita/diagnóstico por imagem , Função Ventricular Direita
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA