Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 50(5): 1510-1520, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36650356

RESUMO

PURPOSE: Consistent assessment of bone metastases is crucial for patient management and clinical trials in prostate cancer (PCa). We aimed to develop a fully automated convolutional neural network (CNN)-based model for calculating PET/CT skeletal tumor burden in patients with PCa. METHODS: A total of 168 patients from three centers were divided into training, validation, and test groups. Manual annotations of skeletal lesions in [18F]fluoride PET/CT scans were used to train a CNN. The AI model was evaluated in 26 patients and compared to segmentations by physicians and to a SUV 15 threshold. PET index representing the percentage of skeletal volume taken up by lesions was estimated. RESULTS: There was no case in which all readers agreed on prevalence of lesions that the AI model failed to detect. PET index by the AI model correlated moderately strong to physician PET index (mean r = 0.69). Threshold PET index correlated fairly with physician PET index (mean r = 0.49). The sensitivity for lesion detection was 65-76% for AI, 68-91% for physicians, and 44-51% for threshold depending on which physician was considered reference. CONCLUSION: It was possible to develop an AI-based model for automated assessment of PET/CT skeletal tumor burden. The model's performance was superior to using a threshold and provides fully automated calculation of whole-body skeletal tumor burden. It could be further developed to apply to different radiotracers. Objective scan evaluation is a first step toward developing a PET/CT imaging biomarker for PCa skeletal metastases.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata , Masculino , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Inteligência Artificial , Carga Tumoral , Neoplasias da Próstata/diagnóstico por imagem , Tomografia por Emissão de Pósitrons
2.
Eur J Vasc Endovasc Surg ; 65(6): 896-904, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36921753

RESUMO

OBJECTIVE: The aim of this study was to describe and present the outcomes of a specific treatment protocol for aortic vascular graft and endograft infections (VGEIs) without explantation of the infected graft. METHODS: This was a retrospective, observational single centre cohort study carried out between 2012 and 2022 at a tertiary hospital. An aortic VGEI was defined according to the Management of Aortic Graft Infection Collaboration (MAGIC) criteria. Fitness for graft excision was assessed by a multidisciplinary team and included an evaluation of the patient's general condition, septic status, and anatomical complexity. Antimicrobial treatments were individualised. The primary outcome was survival at the last available follow up; secondary outcomes were antimicrobial treatment duration, infection eradication, treatment failure despite antimicrobial treatment, and the development of aortic fistulation. RESULTS: Fifty patients were included in the study, of whom 42 (84%) had had previous endovascular repair. The median patient age was 72 years (range 51 - 82 years) and median duration of treatment with antimicrobials was 18 months (range 1 - 164 months). Kaplan-Meier analysis estimated the 30 day survival to be 98% (95% confidence interval [CI] 96 - 100), the one year survival rate to be 88% (95% CI 83.4 - 92.6), and the three year survival rate to be 79% (95% CI 72.7 - 84.7). Twenty-four (48%) patients were able to discontinue antibiotic treatment after a median of 16 months (range 4 - 81 months). When categorised according to infected graft location, deaths occurred in four (40%) patients with thoracic, two (40%) with paravisceral, seven (30%) with infrarenal VGEIs, and in one (25%) patient with an aorto-iliac VGEI; no (0%) patient with a thoraco-abdominal VGEI died. CONCLUSION: Identifying the microbiological aetiology in patients with aortic VGEI enables individualised, specific antibiotic treatment, which may be useful in patients with a VGEI excluded from surgery. This single centre retrospective analysis of patients with VGEIs without fistula selected for conservative treatment suggests that conservative management of aortic VGEIs with targeted antibiotic therapy without graft excision is potentially effective, and that antimicrobial treatment will not necessarily be needed indefinitely.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Infecções Relacionadas à Prótese , Humanos , Pré-Escolar , Criança , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Tratamento Conservador/efeitos adversos , Estudos Retrospectivos , Estudos de Coortes , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Relacionadas à Prótese/cirurgia , Antibacterianos/uso terapêutico , Aneurisma da Aorta Abdominal/cirurgia , Fatores de Risco
3.
Acta Oncol ; 62(2): 180-188, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36815676

RESUMO

BACKGROUND: Cervical cancer is the fourth most common female malignancy. [18F]-fluorodeoxyglucose (FDG) positron emission tomography with computed tomography (PET-CT) is routinely performed in patients with locally advanced cervical cancer for staging and treatment response evaluation. With this retrospective, observational cohort study, we wanted to investigate the prognostic value of the maximum standardised uptake value (SUVmax) and the volumetric parameters of metabolic tumour volume (MTV) and total lesion glycolysis (TLG) before and after treatment in women with cervical cancer, with overall survival (OS) and recurrence as outcome measures. METHODS: Women with cervical cancer referred for curative radiotherapy and who underwent two PET-CT scans (before treatment and approximately 7 months post-treatment) were included. SUVmax, MTV and TLG were measured at baseline and post-treatment on the primary tumour, pelvic and distant lymph node metastases, distant organ metastases, and on total tumour burden. The PET parameters were associated with OS by Cox regression and recurrence by multivariable logistic regression. Kaplan-Meier curves and C-index were used to visualise the prognostic potential of the different measures. RESULTS: A total of 133 patients were included. At the primary tumour level and on total tumour burden, age- and clinical-stage adjusted analyses showed a significant association between PET parameters and OS and recurrence when measured post-treatment. At baseline (pre-treatment), MTV and TLG were associated with OS and recurrence, whereas SUVmax was not. C-index from adjusted Cox models on total tumour burden showed higher values for the post-treatment PET compared to baseline. Kaplan-Meier curves demonstrated a greater prognostic potential for MTV and TLG compared to SUVmax, both at baseline and post-treatment. CONCLUSIONS: The FDG PET-CT-derived parameters SUVmax, MTV, and TLG measured post-treatment can predict OS and recurrence in cervical cancer. Parameters measured before treatment had overall lower prognostic potential, and only MTV and TLG showed significant association to OS and recurrence.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias do Colo do Útero , Humanos , Feminino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Fluordesoxiglucose F18/metabolismo , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Estudos Retrospectivos , Prognóstico , Carga Tumoral , Compostos Radiofarmacêuticos , Tomografia por Emissão de Pósitrons , Glicólise
4.
Eur J Nucl Med Mol Imaging ; 49(10): 3412-3418, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35475912

RESUMO

PURPOSE: The aim of this study was to develop and validate an artificial intelligence (AI)-based method using convolutional neural networks (CNNs) for the detection of pelvic lymph node metastases in scans obtained using [18F]PSMA-1007 positron emission tomography-computed tomography (PET-CT) from patients with high-risk prostate cancer. The second goal was to make the AI-based method available to other researchers. METHODS: [18F]PSMA PET-CT scans were collected from 211 patients. Suspected pelvic lymph node metastases were marked by three independent readers. A CNN was developed and trained on a training and validation group of 161 of the patients. The performance of the AI method and the inter-observer agreement between the three readers were assessed in a separate test group of 50 patients. RESULTS: The sensitivity of the AI method for detecting pelvic lymph node metastases was 82%, and the corresponding sensitivity for the human readers was 77% on average. The average number of false positives was 1.8 per patient. A total of 5-17 false negative lesions in the whole cohort were found, depending on which reader was used as a reference. The method is available for researchers at www.recomia.org . CONCLUSION: This study shows that AI can obtain a sensitivity on par with that of physicians with a reasonable number of false positives. The difficulty in achieving high inter-observer sensitivity emphasizes the need for automated methods. On the road to qualifying AI tools for clinical use, independent validation is critical and allows performance to be assessed in studies from different hospitals. Therefore, we have made our AI tool freely available to other researchers.


Assuntos
Medicina Nuclear , Médicos , Neoplasias da Próstata , Inteligência Artificial , Radioisótopos de Gálio , Humanos , Metástase Linfática/diagnóstico por imagem , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Compostos Radiofarmacêuticos
5.
BJU Int ; 129(2): 174-181, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33626220

RESUMO

OBJECTIVE: To determine whether repeated [18 F]fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET-CT) scans can predict increased cancer-specific survival (CSS) after induction chemotherapy followed by radical cystectomy (RC). PATIENTS AND METHODS: Between 2007 and 2018, 86 patients with clinically lymph node (LN)-positive bladder cancer (T1-T4, N1-N3, M0-M1a) were included and underwent a repeated FDG-PET-CT during cisplatin-based induction chemotherapy. The 71 patients that had a response to chemotherapy underwent RC. Response to chemotherapy was evaluated in LNs through repeated FDG-PET-CT and stratified as partial response or complete response using three different methods: maximum standardised uptake value (SUVmax ), adapted Deauville criteria, and total lesion glycolysis (TLG). Progression-free survival (PFS) and CSS were analysed for all three methods by Cox regression analysis. RESULTS: After a median follow-up of 40 months, 15 of the 71 patients who underwent RC had died from bladder cancer. Using SUVmax and the adapted Deauville criteria, multivariable Cox regression analyses adjusting for age, clinical tumour stage and LN stage showed that complete response was associated with increased PFS (hazard ratio [HR] 3.42, 95% confidence interval [CI] 1.20-9.77) and CSS (HR 3.30, 95% CI 1.02-10.65). Using TLG, a complete response was also associated with increased PFS (HR 5.17, 95% CI 1.90-14.04) and CSS (HR 6.32, 95% CI 2.06-19.41). CONCLUSIONS: Complete metabolic response with FDG-PET-CT predicts survival after induction chemotherapy followed by RC in patients with LN-positive bladder cancer and comprises a novel tool in evaluating response to chemotherapy before surgery. This strategy has the potential to tailor treatment in individual patients by identifying significant response to chemotherapy, which motivates the administration of a full course of induction chemotherapy with a higher threshold for suspending treatment due to toxicity and side-effects.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Bexiga Urinária , Cistectomia , Fluordesoxiglucose F18/farmacologia , Humanos , Quimioterapia de Indução , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Metástase Linfática/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Prognóstico , Compostos Radiofarmacêuticos/uso terapêutico , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Neoplasias da Bexiga Urinária/tratamento farmacológico , Neoplasias da Bexiga Urinária/cirurgia
6.
BMC Cancer ; 21(1): 447, 2021 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-33888074

RESUMO

BACKGROUND: This study investigates the patterns of PET-positive lymph nodes (LNs) in anal cancer. The aim was to provide information that could inform future anal cancer radiotherapy contouring guidelines. METHODS: The baseline [18F]-FDG PET-CTs of 190 consecutive anal cancer patients were retrospectively assessed. LNs with a Deauville score (DS) of ≥3 were defined as PET-positive. Each PET-positive LN was allocated to a LN region and a LN sub-region; they were then mapped on a standard anatomy reference CT. The association between primary tumor localization and PET-positive LNs in different regions were analyzed. RESULTS: PET-positive LNs (n = 412) were identified in 103 of 190 patients (54%). Compared to anal canal tumors with extension into the rectum, anal canal tumors with perianal extension more often had inguinal (P < 0.001) and less often perirectal (P < 0.001) and internal iliac (P < 0.001) PET-positive LNs. Forty-two patients had PET-positive LNs confined to a solitary region, corresponding to first echelon nodes. The most common solitary LN region was inguinal (25 of 42; 60%) followed by perirectal (26%), internal iliac (10%), and external iliac (2%). No PET-positive LNs were identified in the ischiorectal fossa or in the inguinal area located posterolateral to deep vessels. Skip metastases above the bottom of the sacroiliac joint were quite rare. Most external iliac PET-positive LNs were located posterior to the external iliac vein; only one was located in the lateral external iliac sub-region. CONCLUSIONS: The results support some specific modifications to the elective clinical target volume (CTV) in anal cancer. These changes would lead to reduced volumes of normal tissue being irradiated, which could contribute to a reduction in radiation side-effects.


Assuntos
Neoplasias do Ânus/diagnóstico , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Neoplasias do Ânus/radioterapia , Fluordesoxiglucose F18 , Humanos , Imageamento Tridimensional , Metástase Linfática , Estadiamento de Neoplasias , Pelve/diagnóstico por imagem , Pelve/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada
7.
BMC Med Imaging ; 19(1): 81, 2019 10 22.
Artigo em Inglês | MEDLINE | ID: mdl-31640584

RESUMO

BACKGROUND: A new generation of positron emission tomography with computed tomography (PET-CT) was recently introduced using silicon (Si) photomultiplier (PM)-based technology. Our aim was to compare the image quality and diagnostic performance of a SiPM-based PET-CT (Discovery MI; GE Healthcare, Milwaukee, WI, USA) with a time-of-flight PET-CT scanner with a conventional PM detector (Gemini TF; Philips Healthcare, Cleveland, OH, USA), including reconstruction algorithms per vendor's recommendations. METHODS: Imaging of the National Electrical Manufacturers Association IEC body phantom and 16 patients was carried out using 1.5 min/bed for the Discovery MI PET-CT and 2 min/bed for the Gemini TF PET-CT. Images were analysed for recovery coefficients for the phantom, signal-to-noise ratio in the liver, standardized uptake values (SUV) in lesions, number of lesions and metabolic TNM classifications in patients. RESULTS: In phantom, the correct (> 90%) activity level was measured for spheres ≥17 mm for Discovery MI, whereas the Gemini TF reached a correct measured activity level for the 37-mm sphere. In patient studies, metabolic TNM classification was worse using images obtained from the Discovery MI compared those obtained from the Gemini TF in 4 of 15 patients. A trend toward more malignant, inflammatory and unclear lesions was found using images acquired with the Discovery MI compared with the Gemini TF, but this was not statistically significant. Lesion-to-blood-pool SUV ratios were significantly higher in images from the Discovery MI compared with the Gemini TF for lesions smaller than 1 cm (p < 0.001), but this was not the case for larger lesions (p = 0.053). The signal-to-noise ratio in the liver was similar between platforms (p = 0.52). Also, shorter acquisition times were possible using the Discovery MI, with preserved signal-to-noise ratio in the liver. CONCLUSIONS: Image quality was better with Discovery MI compared to conventional Gemini TF. Although no gold standard was available, the results indicate that the new PET-CT generation will provide potentially better diagnostic performance.


Assuntos
Interpretação de Imagem Assistida por Computador/instrumentação , Fígado/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Fluordesoxiglucose F18/administração & dosagem , Humanos , Imagens de Fantasmas , Razão Sinal-Ruído , Imagem Corporal Total
8.
BMC Med Imaging ; 18(1): 8, 2018 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-29728144

RESUMO

BACKGROUND: The Bone Scan Index (BSI) is used to quantitatively assess the total tumour burden in bone scans of patients with metastatic prostate cancer. The clinical utility of BSI has recently been validated as a prognostic imaging biomarker. However, the clinical utility of the on-treatment change in BSI is dependent on the reproducibility of bone scans. The objective of this prospective study is to evaluate the intra-patient reproducibility of two bone scan procedures performed at a one-week interval. METHODS: We prospectively studied prostate cancer patients who were referred for bone scintigraphy at our centres according to clinical routine. All patients underwent two whole-body bone scans: one for clinical routine purposes and a second one as a repeated scan after approximately one week. BSI values were obtained for each bone scintigraph using EXINI boneBSI software. RESULTS: A total of 20 patients were enrolled. There was no statistical difference between the BSI values of the first (median = 0.66, range 0-40.77) and second (median = 0.63, range 0-22.98) bone scans (p = 0.41). The median difference in BSI between the clinical routine and repeated scans was - 0.005 (range - 17.79 to 0). The 95% confidence interval for the median value was - 0.1 to 0. A separate analysis was performed for patients with BSI ≤ 10 (n = 17). Differences in BSI were smaller for patients with BSI ≤ 10 compared to the whole cohort (median - 0.1, range - 2.2-0, 95% confidence interval - 0.1 to 0). CONCLUSIONS: The automated BSI demonstrated high intra-individual reproducibility for BSI ≤ 10 in the two repeated bone scans of patients with prostate cancer. The study supports the use of BSI as a quantitative parameter to evaluate the change in total tumour burden in bone scans.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Osso e Ossos/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Osso e Ossos/patologia , Humanos , Masculino , Estudos Prospectivos , Cintilografia , Reprodutibilidade dos Testes , Imagem Corporal Total
10.
Eur J Nucl Med Mol Imaging ; 42(12): 1929-40, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26290421

RESUMO

Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have been made, improving MPI procedures. In this paper, the major changes from the updated 2015 procedural guidelines are highlighted, focusing on the important changes related to new instrumentation with improved image information and the possibility to reduce radiation exposure, which is further discussed in relation to the recent developments of new International Commission on Radiological Protection (ICRP) models. Introduction of the selective coronary vasodilator regadenoson and the use of coronary CT-contrast agents for hybrid imaging with SPECT/CT angiography are other important areas for nuclear cardiology that were not included in the previous guidelines. A large number of minor changes have been described in more detail in the fully revised version available at the EANM home page: http://eanm.org/publications/guidelines/2015_07_EANM_FINAL_myocardial_perfusion_guideline.pdf .


Assuntos
Imagem de Perfusão do Miocárdio/métodos , Guias de Prática Clínica como Assunto , Sociedades Médicas , Tomografia Computadorizada por Raios X/métodos , Adulto , Meios de Contraste , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Relação Dose-Resposta a Droga , Exercício Físico , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Imagem de Perfusão do Miocárdio/efeitos adversos , Imagem de Perfusão do Miocárdio/instrumentação , Purinas/efeitos adversos , Purinas/farmacologia , Pirazóis/efeitos adversos , Pirazóis/farmacologia , Exposição à Radiação , Segurança , Software , Tomografia Computadorizada por Raios X/efeitos adversos , Tomografia Computadorizada por Raios X/instrumentação , Vasodilatadores/efeitos adversos , Vasodilatadores/farmacologia
11.
J Electrocardiol ; 48(4): 558-64, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25705035

RESUMO

INTRODUCTION: About one-third of patients undergoing cardiac resynchronization therapy because of left bundle branch block (LBBB) and heart failure do not improve. Strauss et al. have developed strict criteria to more accurately define complete LBBB in this patient group. The aim of this study was to investigate the prevalence of the manual application of the Strauss criteria for LBBB (QRS ≥ 140 ms in men, ≥ 130 ms in women, along with mid-QRS notching/slurring) in consecutive patients who have been diagnosed with LBBB by the automated Glasgow criteria (QRS ≥ 120 ms). METHOD: In 158 consecutive patients (78 females) diagnosed with LBBB according to the automated Glasgow criteria, the manual Strauss criteria were applied. RESULTS & CONCLUSION: A majority of patients (87%) diagnosed with LBBB using the Glasgow criteria were positive for the Strauss criteria. In 70% (13/20) of the cases of disagreement the reason for disagreement was short QRS duration.


Assuntos
Algoritmos , Bloqueio de Ramo/classificação , Bloqueio de Ramo/diagnóstico , Diagnóstico por Computador/métodos , Eletrocardiografia/métodos , Índice de Gravidade de Doença , Idoso , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
J Nucl Cardiol ; 21(3): 416-23, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24442889

RESUMO

BACKGROUND: The aim of this myocardial perfusion imaging (MPI) study was to compare the diagnostic performance of two computer-aided diagnosis (CAD) systems, EXINI Heart(TM) (EXINI), and PERFEX(TM) (PERFEX) Emory Cardiac Toolbox (ECT), and the summed stress score (SSS) values from both software packages. METHODS: We studied 1,052 consecutive patients who underwent 2-day stress/rest (99m)Tc-sestamibi MPI studies. The reference standard classifications for the MPI studies were obtained from three experienced physicians who separately classified all cases regarding the presence or absence of ischemia and/or infarction. Automatic processing was carried out using EXINI and PERFEX to obtain CAD results and SSS values based on the 17-segment model. RESULTS: The three experts' classifications showed ischemia in 257 patients and abnormal studies, i.e., either ischemia or infarction or both, in 318 patients. Accuracy was significantly higher in EXINI than in PERFEX, regarding both the detection of ischemia (87.4 vs 77.6%; P < 0.0001) and the detection of abnormal studies (91.6 vs 67.9%; P < 0.0001). EXINI's CAD system showed a higher specificity than its SSS values (86.8 vs 73.6%; P < 0.0001) at the same level of sensitivity. CONCLUSIONS: EXINI demonstrated greater diagnostic accuracy for detection of ischemia and abnormal studies than did PERFEX. EXINI CAD also outperformed its SSS analysis.


Assuntos
Algoritmos , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/estatística & dados numéricos , Doença da Artéria Coronariana/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagem de Perfusão do Miocárdio/estatística & dados numéricos , Reconhecimento Automatizado de Padrão/métodos , Software , Adulto , Idoso , Idoso de 80 Anos ou mais , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/métodos , Variações Dependentes do Observador , Reconhecimento Automatizado de Padrão/estatística & dados numéricos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Validação de Programas de Computador
13.
BMC Med Imaging ; 14: 5, 2014 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-24479846

RESUMO

BACKGROUND: The European Society of Cardiology recommends that patients with >10% area of ischemia should receive revascularization. We investigated inter-observer variability for the extent of ischemic defects reported by different physicians and by different software tools, and if inter-observer variability was reduced when the physicians were provided with a computerized suggestion of the defects. METHODS: Twenty-five myocardial perfusion single photon emission computed tomography (SPECT) patients who were regarded as ischemic according to the final report were included. Eleven physicians in nuclear medicine delineated the extent of the ischemic defects. After at least two weeks, they delineated the defects again, and were this time provided a suggestion of the defect delineation by EXINI HeartTM (EXINI). Summed difference scores and ischemic extent values were obtained from four software programs. RESULTS: The median extent values obtained from the 11 physicians varied between 8% and 34%, and between 9% and 16% for the software programs. For all 25 patients, mean extent obtained from EXINI was 17.0% (± standard deviation (SD) 14.6%). Mean extent for physicians was 22.6% (± 15.6%) for the first delineation and 19.1% (± 14.9%) for the evaluation where they were provided computerized suggestion. Intra-class correlation (ICC) increased from 0.56 (95% confidence interval (CI) 0.41-0.72) to 0.81 (95% CI 0.71-0.90) between the first and the second delineation, and SD between physicians were 7.8 (first) and 5.9 (second delineation). CONCLUSIONS: There was large variability in the estimated ischemic defect size obtained both from different physicians and from different software packages. When the physicians were provided with a suggested delineation, the inter-observer variability decreased significantly.


Assuntos
Isquemia Miocárdica/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Software , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Médicos , Radiografia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Validação de Programas de Computador
14.
Clin Physiol Funct Imaging ; 44(4): 332-339, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38563413

RESUMO

BACKGROUND: We developed a fully automated artificial intelligence (AI)AI-based-based method for detecting suspected lymph node metastases in prostate-specific membrane antigen (PSMA)(PSMA) positron emission tomography-computed tomography (PET-CT)(PET-CT) images of prostate cancer patients by using data augmentation that adds synthetic lymph node metastases to the images to expand the training set. METHODS: Synthetic data were derived from original training images to which new synthetic lymph node metastases were added. Thus, the original training set from a previous study (n = 420) was expanded by one synthetic image for every original image (n = 840), which was used to train an AI model. The performance of the AI model was compared to that of nuclear medicine physicians and a previously developed AI model. The human readers were alternately used as a reference and compared to either another reading or AI model. RESULTS: The new AI model had an average sensitivity of 84% for detecting lymph node metastases compared with 78% for human readings. Our previously developed AI method without synthetic data had an average sensitivity of 79%. The number of false positive lesions were slightly higher for the new AI model (average 3.3 instances per patient) compared to human readings and the previous AI model (average 2.8 instances per patient), while the number of false negative lesions was lower. CONCLUSIONS: Creating synthetic lymph node metastases, as a form of data augmentation, on [18F]PSMA-1007F]PSMA-1007 PETPET-CT-CT images improved the sensitivity of an AI model for detecting suspected lymph node metastases. However, the number of false positive lesions increased somewhat.


Assuntos
Glutamato Carboxipeptidase II , Linfonodos , Metástase Linfática , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Valor Preditivo dos Testes , Neoplasias da Próstata , Humanos , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Glutamato Carboxipeptidase II/metabolismo , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Reprodutibilidade dos Testes , Antígenos de Superfície/metabolismo , Inteligência Artificial , Automação , Idoso , Interpretação de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos
15.
Abdom Radiol (NY) ; 49(4): 1042-1050, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38319345

RESUMO

OBJECTIVES: Pre-treatment staging of anal squamous cell carcinoma (ASCC) includes pelvic MRI and [18F]-fluorodeoxyglucose positron emission tomography with computed tomography (PET-CT). MRI criteria to define lymph node metastases (LNMs) in ASCC are currently lacking. The aim of this study was to describe the morphological characteristics of lymph nodes (LNs) on MRI in ASCC patients with PET-CT-positive LNs. METHODS: ASCC patients treated at Skåne University Hospital between 2009 and 2017 were eligible for inclusion if at least one positive LN according to PET-CT and a pre-treatment MRI were present. All PET-CT-positive LNs and PET-CT-negative LNs were retrospectively identified on baseline MRI. Each LN was independently classified according to pre-determined morphological characteristics by two radiologists blinded to clinical patient information. RESULTS: Sixty-seven ASCC patients were included, with a total of 181 PET-CT-positive LNs identified on baseline MRI with a median short-axis diameter of 9.0 mm (range 7.5-12 mm). MRI morphological characteristics of PET-CT-positive LNs included regular contour (87%), round shape (89%), and homogeneous signal intensity on T2-weighed images (67%). An additional 78 PET-CT-negative LNs were identified on MRI. These 78 LNs had a median size of 6.8 mm (range 5.5-8.0 mm). The majority of PET-CT-negative LNs had a regular contour, round shape, and a homogeneous signal that was congruent to the primary tumor. CONCLUSIONS: There are MRI-specific morphological characteristics for pelvic LNs in ASCC. PET-CT-positive and negative LNs share similar morphological features apart from size, with PET-CT-positive LNs being significantly larger. Further studies are needed to determine discrimination criteria for LNM in ASCC.


Assuntos
Carcinoma de Células Escamosas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Estudos Retrospectivos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Fluordesoxiglucose F18 , Imageamento por Ressonância Magnética/métodos , Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/patologia , Estadiamento de Neoplasias , Compostos Radiofarmacêuticos
16.
Osteoporos Sarcopenia ; 10(2): 78-83, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39035229

RESUMO

Objectives: Evaluation of sarcopenia from computed tomography (CT) is often based on measuring skeletal muscle area on a single transverse slice. Automatic segmentation of muscle volume has a lower variance and may be a better proxy for the total muscle volume than single-slice areas. The aim of the study was to determine which abdominal and thoracic anatomical volumes were best at predicting the total muscle volume. Methods: A cloud-based artificial intelligence tool (recomia.org) was used to segment all skeletal muscle of the torso of 994 patients who had performed whole-torso CT 2008-2020 for various clinical indications. Linear regression models for several anatomical volumes and single-slice areas were compared with regard to predicting the total torso muscle volume. Results: The muscle volume from the tip of the coccyx and 25 cm cranially was the best of the abdominal volumes and was significantly better than the L3 slice muscle area (R2 0.935 vs 0.830, P < 0.0001). For thoracic volumes, the muscle volume between the top of the sternum to the lower bound of the Th12 vertebra showed the best correlation with the total volume, significantly better than the Th12 slice muscle area (R2 0.892 vs 0.775, P < 0.0001). Adjusting for body height improved the correlation slightly for all measurements but did not significantly change the ordering. Conclusions: We identified muscle volumes that can be reliably segmented by automated image analysis which is superior to single slice areas in predicting total muscle volume.

17.
EJNMMI Rep ; 8(1): 24, 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39112915

RESUMO

PURPOSE: There is a lack of validated imaging biomarkers for prediction of response to peptide receptor radionuclide therapy (PRRT). The primary objective was to evaluate if tumour burden at baseline PET/CT could predict treatment outcomes to PRRT with [177Lu]Lu-DOTA-TATE. Secondary objectives were to evaluate if there was a correlation between tumour burden and mean tumour absorbed dose (AD) during first cycle, and if mean tumour AD or the relative change of tumour burden at first follow-up PET/CT could predict progression free survival (PFS) or overall survival (OS). METHODS: Patients with gastroenteropancreatic neuroendocrine tumour (GEP-NET) treated with [177Lu]Lu-DOTA-TATE PRRT were retrospectively included. Tumour burden was quantified from [68 Ga]Ga-DOTA-TOC/TATE PET/CT-images at baseline and first follow-up and expressed as; whole-body somatostatin receptor expressing tumour volume (SRETVwb), total lesion somatostatin receptor expression (TLSREwb), largest tumour lesion diameter and highest SUVmax. The relative change of tumour burden was evaluated in three categories. Mean tumour AD was estimated from the first cycle of PRRT. PFS was defined as time from start of PRRT to radiological or clinical progression. OS was evaluated as time to death. Kaplan Meier survival curves and log-rank test were used to compare PFS and OS between different groups. RESULTS: Thirty-one patients had a baseline PET/CT < 6 months before treatment and 25 had a follow-up examination. Median tumour burden was 132 ml (IQR 61-302) at baseline and 71 ml (IQR 36-278) at follow-up. Twenty-two patients had disease progression (median time to progression 17.2 months) and 9 patients had no disease progression (median follow-up 28.7 months). SRETVwb dichotomized by the median at baseline was not associated with longer PFS (p = 0.861) or OS (p = 0.937). Neither TLSREwb, largest tumour lesion or SUVmax showed significant predictive value. There was a moderately strong correlation, however, between SUVmax and mean tumour AD r = 0.705, p < 0.001, but no significant correlation between SRETVwb nor TLSREwb and mean tumour AD. An increase of SRETVwb, TLSREwb or largest tumour lesion at first follow-up PET/CT was significantly correlated with shorter PFS/OS. CONCLUSION: Tumour burden at baseline showed no predictive value of PFS/OS after PRRT in this small retrospective study. An increase of tumour burden was predictive of worse outcome.

18.
Semin Nucl Med ; 54(1): 141-149, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37357026

RESUMO

Prostate-specific membrane antigen (PSMA) positron emission tomography/computed tomography (PET/CT) has emerged as an important imaging technique for prostate cancer. The use of PSMA PET/CT is rapidly increasing, while the number of nuclear medicine physicians and radiologists to interpret these scans is limited. Additionally, there is variability in interpretation among readers. Artificial intelligence techniques, including traditional machine learning and deep learning algorithms, are being used to address these challenges and provide additional insights from the images. The aim of this scoping review was to summarize the available research on the development and applications of AI in PSMA PET/CT for prostate cancer imaging. A systematic literature search was performed in PubMed, Embase and Cinahl according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. A total of 26 publications were included in the synthesis. The included studies focus on different aspects of artificial intelligence in PSMA PET/CT, including detection of primary tumor, local recurrence and metastatic lesions, lesion classification, tumor quantification and prediction/prognostication. Several studies show similar performances of artificial intelligence algorithms compared to human interpretation. Few artificial intelligence tools are approved for use in clinical practice. Major limitations include the lack of external validation and prospective design. Demonstrating the clinical impact and utility of artificial intelligence tools is crucial for their adoption in healthcare settings. To take the next step towards a clinically valuable artificial intelligence tool that provides quantitative data, independent validation studies are needed across institutions and equipment to ensure robustness.


Assuntos
Próstata , Neoplasias da Próstata , Masculino , Humanos , Próstata/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Inteligência Artificial , Radioisótopos de Gálio , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia
19.
Scand J Urol ; 59: 90-97, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38698545

RESUMO

OBJECTIVE: To evaluate whether artificial intelligence (AI) based automatic image analysis utilising convolutional neural networks (CNNs) can be used to evaluate computed tomography urography (CTU) for the presence of urinary bladder cancer (UBC) in patients with macroscopic hematuria. METHODS: Our study included patients who had undergone evaluation for macroscopic hematuria. A CNN-based AI model was trained and validated on the CTUs included in the study on a dedicated research platform (Recomia.org). Sensitivity and specificity were calculated to assess the performance of the AI model. Cystoscopy findings were used as the reference method. RESULTS: The training cohort comprised a total of 530 patients. Following the optimisation process, we developed the last version of our AI model. Subsequently, we utilised the model in the validation cohort which included an additional 400 patients (including 239 patients with UBC). The AI model had a sensitivity of 0.83 (95% confidence intervals [CI], 0.76-0.89), specificity of 0.76 (95% CI 0.67-0.84), and a negative predictive value (NPV) of 0.97 (95% CI 0.95-0.98). The majority of tumours in the false negative group (n = 24) were solitary (67%) and smaller than 1 cm (50%), with the majority of patients having cTaG1-2 (71%). CONCLUSIONS: We developed and tested an AI model for automatic image analysis of CTUs to detect UBC in patients with macroscopic hematuria. This model showed promising results with a high detection rate and excessive NPV. Further developments could lead to a decreased need for invasive investigations and prioritising patients with serious tumours.


Assuntos
Inteligência Artificial , Hematúria , Tomografia Computadorizada por Raios X , Neoplasias da Bexiga Urinária , Urografia , Humanos , Hematúria/etiologia , Hematúria/diagnóstico por imagem , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Neoplasias da Bexiga Urinária/complicações , Masculino , Idoso , Feminino , Tomografia Computadorizada por Raios X/métodos , Urografia/métodos , Pessoa de Meia-Idade , Redes Neurais de Computação , Sensibilidade e Especificidade , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Adulto
20.
Eur Heart J Imaging Methods Pract ; 2(1): qyae051, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-39224107

RESUMO

Aims: Non-invasive diagnosis of amyloid transthyretin (ATTR) cardiac amyloidosis using planar scintigraphy and single-photon emission computed tomography-computed tomography (SPECT-CT) with [99mTc]Tc-3,3-diphosphono-1,2-propanodicarboxylic acid ([99mTc]Tc-DPD) has high specificity and sensitivity. However, the introduction of ring-configured cadmium zinc telluride (CZT) gamma cameras warrants an update in the acquisition method since these systems are not able to perform planar scintigraphy. We aimed to verify the use of reprojected planar images from SPECT-CT as a replacement for planar scintigraphy in evaluating ATTR-amyloidosis. Methods and results: The study examined 30 patients referred for clinically indicated [99mTc]Tc-DPD scintigraphy who were scanned with both a conventional gamma camera and a ring-configured CZT gamma camera. Planar scintigraphy from the conventional gamma camera was compared with reprojected planar images from the ring-configured CZT gamma camera. The images were evaluated in regard to image quality and Perugini visual score in a blinded fashion by three nuclear medicine physicians. Heart-to-contralateral (H/CL) ratios were calculated. There were 27 patients who had an identical Perugini score in planar and reprojected planar images, yielding a strong level of agreement and inter-rater reliability among the three readers. The H/CL ratios showed a strong correlation ratio (r = 0.98, P < 0.0001). A shift towards lower image quality was seen for the reprojected images. Conclusion: Reprojected planar images generated from a ring-configured CZT gamma camera combined with SPECT-CT can be used to score ATTR amyloidosis and extract H/CL ratios in the same way as planar images and SPECT-CT from a conventional gamma camera.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA