Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 12(3)2022 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-35328282

RESUMO

Liquid biopsies are an integral part of the diagnosis of cancer. Here, we have extended previous validation studies of a new targeted NGS panel to include the detection of copy number amplifications (CNAs), fusions, and exon skipping variants. Detection of these gene classes included specimens from clinical and healthy donors and cell lines (fusions: ROS1, EML4-ALK, NTRK1; exon skipping: MET exon 14; CNAs: HER2, CDK6, EGFR, MYC, and MET). The limit of detection (LOD) for fusion/skipping was 42 copies (QC threshold was three copies) and was verified using three additional fusion/skipping variants. LOD for CNAs was 1.40-fold-change (QC threshold = 1.15-fold change) and was verified with three additional CNAs. In repeatability and intermediate precision (within lab) studies, all fusion/skipping variants were detected in all runs and all days of testing (n = 18/18; 100%); average CV for repeatability was 20.5% (range 8.7-34.8%), and for intermediate precision it was 20.8% (range 15.7-30.5%). For CNAs, 28/29 (96.6%) copy gains were detected. For CNAs, the average CV was 1.85% (range 0% to 5.49%) for repeatability and 6.59% (range 1.65% to 9.22%) for intermediate precision. The test panel meets the criteria for being highly sensitive and specific and extends its utility for the serial detection of clinically relevant variants in cancer.

2.
Diagnostics (Basel) ; 11(2)2021 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-33494470

RESUMO

Liquid biopsy tests have become an integral part of the molecular diagnosis of patients with non-small cell lung cancer (NSCLC). We describe a new test panel that uses very low input (20 ng) of cell-free nucleic acids extracted from human plasma, which is designed to yield results in less than 72 h. In this study, we performed novel amplicon-based targeted next-generation sequencing with a semiconductor-based system, the Ion GeneStudio S5 Prime. The analytic performance of the assay was evaluated using contrived and retrospectively collected clinical specimens. The cumulative percent coefficient of variation for the new test process was very precise at 8.4% for inter-day, 4.0% for inter-operator and 3.4% for inter-instrument. We also observed significant agreement (95.7-100%) with an orthogonal, high-sensitivity droplet digital™ Polymerase Chain Reaction (ddPCR) test. This method offers a valuable supplement to assessing targeted mutations from blood while conserving specimens and maintaining sensitivity, with rapid turn-around times to actionable results.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA