Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Front Surg ; 11: 1331902, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38645507

RESUMO

Introduction: The varus and valgus knee deformities result from imbalance in tension between medial and lateral soft tissue compartments. These conditions need to be addressed during total knee arthroplasty (TKA). However, there is no consensus on optimal soft-tissue release techniques for correcting varus and valgus deformities during TKA. We assessed the efficacy of a novel grid-based pie-crusting technique on soft-tissue release. Methods: Cadaver knees were dissected, leaving only the femur and tibia connected by an isolated MCL or the femur and fibula connected by an isolated LCL. Bone cuts were made as performed during primary TKA. Mechanical testing was performed using an MTS machine. A 3D-printed 12-hole grid was placed directly over the MCL and LCL. Using an 18-gauge needle, horizontal in-out perforations were made 3 mm apart. Deformation and stiffness of the ligaments were collected after every 2 perforations. Means were calculated, and regression analyses were performed. Results: A total of 7 MCL and 6 LCL knees were included in our analysis. The mean medial femorotibial (MFT) space increased from 6.018 ± 1.4 mm-7.078 ± 1.414 mm (R2 = 0.937) following 12 perforations. The mean MCL stiffness decreased from 32.15 N/mm-26.57 N/mm (R2 = 0.965). For the LCL group, the mean gap between the femur and fibula increased from 4.287 mm-4.550 mm following 8 perforations. The mean LCL stiffness decreased from 29.955 N/mm-25.851 N/mm. LCL stiffness displayed a strong inverse relationship with the number of holes performed (R2 = 0.988). Discussion: Our results suggest that using this novel grid for pie-crusting of the MCL and LCL allows for gradual lengthening of the ligaments without sacrificing their structural integrity. Our proposed technique may serve as a valuable piece in the soft-tissue release toolkit for orthopaedic surgeons performing TKA in varus and valgus deformed knees.

2.
J Mech Behav Biomed Mater ; 138: 105600, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36525875

RESUMO

Due to structural heterogeneities within the tissue, the myocardium displays an orthotropic material behavior. However, the link between the microstructure and the macroscopic mechanical properties is still not fully established. In particular, if it is admitted that the cardiomyocyte organization induces a transversely isotropic symmetry, the relative role in the observed orthotropic symmetry of cardiomyocyte orientation variation and perimysium collagen "sheetlet" structure, two mechanisms occurring at different scales, is still a matter of debate. In order to shed light on this question, we designed a multiscale model of the myocardium, bridging the cell, sheetlet and tissue scales. More precisely, we compared the macroscopic anisotropy obtained by homogenization of different mesostructures consisting in cardiomyocytes and extracellular collageneous layers, also taking into account the variation of cardiomyocyte and sheetlet orientations on the macroscale, to available experimental data. This study confirms the importance of sheetlets layers in assuring the tissue's anisotropic response, as cardiomyocytes-only mesostructures cannot reproduce the observed anisotropy. Moreover, our model shows the existence of a size effect in the myocardial tissue shear properties, which will require further experimental analysis.


Assuntos
Colágeno , Miocárdio , Anisotropia , Colágeno/química , Músculo Esquelético , Estresse Mecânico
3.
Nat Commun ; 14(1): 8020, 2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38049428

RESUMO

BMP-1/tolloid-like proteinases (BTPs) are major players in tissue morphogenesis, growth and repair. They act by promoting the deposition of structural extracellular matrix proteins and by controlling the activity of matricellular proteins and TGF-ß superfamily growth factors. They have also been implicated in several pathological conditions such as fibrosis, cancer, metabolic disorders and bone diseases. Despite this broad range of pathophysiological functions, the putative existence of a specific endogenous inhibitor capable of controlling their activities could never be confirmed. Here, we show that procollagen C-proteinase enhancer-2 (PCPE-2), a protein previously reported to bind fibrillar collagens and to promote their BTP-dependent maturation, is primarily a potent and specific inhibitor of BTPs which can counteract their proteolytic activities through direct binding. PCPE-2 therefore differs from the cognate PCPE-1 protein and extends the possibilities to fine-tune BTP activities, both in physiological conditions and in therapeutic settings.


Assuntos
Glicoproteínas , Peptídeo Hidrolases , Humanos , Glicoproteínas/metabolismo , Proteínas da Matriz Extracelular/metabolismo , Morfogênese , Peptídeos e Proteínas de Sinalização Intercelular
4.
Sci Rep ; 10(1): 20531, 2020 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-33239670

RESUMO

Despite recent advances, the myocardial microstructure remains imperfectly understood. In particular, bundles of cardiomyocytes have been observed but their three-dimensional organisation remains debated and the associated mechanical consequences unknown. One of the major challenges remains to perform multiscale observations of the mechanical response of the heart wall. For this purpose, in this study, a full-field Mueller polarimetric imager (MPI) was combined, for the first time, with an in-situ traction device. The full-field MPI enables to obtain a macroscopic image of the explored tissue, while providing detailed information about its structure on a microscopic scale. Specifically it exploits the polarization of the light to determine various biophysical quantities related to the tissue scattering or anisotropy properties. Combined with a mechanical traction device, the full-field MPI allows to measure the evolution of such biophysical quantities during tissue stretch. We observe separation lines on the tissue, which are associated with a fast variation of the fiber orientation, and have the size of cardiomyocyte bundles. Thus, we hypothesize that these lines are the perimysium, the collagen layer surrounding these bundles. During the mechanical traction, we observe two mechanisms simultaneously. On one hand, the azimuth shows an affine behavior, meaning the orientation changes according to the tissue deformation, and showing coherence in the tissue. On the other hand, the separation lines appear to be resistant in shear and compression but weak against traction, with a forming of gaps in the tissue.


Assuntos
Bioensaio/métodos , Miocárdio/patologia , Polarimetria de Varredura a Laser , Animais , Estresse Mecânico , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA