Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Curr Cardiol Rep ; 21(6): 52, 2019 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-31065869

RESUMO

PURPOSE OF REVIEW: Transseptal puncture is a routinely performed interventional cardiology procedure for an array of cardiac diseases. We aimed to review the current status of available devices and techniques of transseptal puncture with consideration to specific interventions. RECENT FINDINGS: Except for a few modifications, devices for transseptal puncture technique has not changed much compared to when it was first described almost 60 years ago. For difficult transseptal puncture, a few newer techniques such as radio frequency needle puncture system have been used but there is lack of robust clinical study. Advanced imaging, such as intracardiac echocardiography and transesophageal echocardiography, has been found to make transseptal puncture safer. A new transseptal approach that incorporates 3D non-fluoroscopic catheter tracking systems has shown promising results in two human studies. While various modifications in the transseptal technique tailored to the specific interventions have improved procedural safety, further improvement in existing devices focusing on distinct procedure might be needed in the future.


Assuntos
Cateterismo Cardíaco/métodos , Ablação por Cateter/métodos , Cardiopatias/terapia , Septos Cardíacos/cirurgia , Punções/métodos , Cateterismo Cardíaco/instrumentação , Ablação por Cateter/instrumentação , Cardiopatias/cirurgia , Humanos , Terapia a Laser , Agulhas , Punções/instrumentação
2.
J Atr Fibrillation ; 13(6): 20200446, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34950348

RESUMO

BACKGROUND: Smartphone technologies have been recently developed to assess heart rate and rhythm, but their role in accurately detecting atrial fibrillation (AF) remains unknown. OBJECTIVE: We sought to perform a meta-analysis using prospective studies comparing Smartwatch technology with current monitoring standards for AF detection (ECG, Holter, Patch Monitor, ILR). METHODS: We performed a comprehensive literature search for prospective studies comparing Smartwatch technology simultaneously with current monitoring standards (ECG, Holter, and Patch monitor) for AF detection since inception to November 25th, 2019. The outcome studied was the accuracy of AF detection. Accuracy was determined with concomitant usage of ECG monitoring, Holter monitoring, loop recorder, or patch monitoring. RESULTS: A total of 9 observational studies were included comparing smartwatch technology, 3 using single-lead ECG monitoring, and six studies using photoplethysmography with routine AF monitoring strategies. A total of 1559 patients were enrolled (mean age 63.5 years, 39.5% had an AF history). The mean monitoring time was 75.6 days. Smartwatch was non-inferior to composite ECG monitoring strategies (OR 1.06, 95% CI 0.93 - 1.21, p=0.37), composite 12 lead ECG/Holter monitoring (OR 0.90, 95% CI 0.62 - 1.30, p=0.57) and patch monitoring (OR 1.28, 95% CI 0.84 - 1.94, p=0.24) for AF detection. The sensitivity and specificity for AF detection using a smartwatch was 95% and 94%, respectively. CONCLUSIONS: Smartwatch based single-lead ECG and photoplethysmography appear to be reasonable alternatives for AF monitoring.

3.
Heart Rhythm ; 17(9): 1575-1581, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32389681

RESUMO

BACKGROUND: Single-chamber leadless pacemakers (LPs) have been shown to be an effective alternative to conventional transvenous pacemakers (CTPs), but their benefit in the context of cardioinhibitory vasovagal syncope (CI-VVS) is unknown. OBJECTIVE: The purpose of this study was to evaluate the safety and efficacy of LP compared with dual-chamber CTP for CI-VVS. METHODS: We conducted a multicenter, retrospective study comparing patients who received LP or dual-chamber CTP for drug-refractory CI-VVS. CI-VVS was diagnosed clinically and supported by cardiac monitoring and head-up tilt table testing. The primary efficacy endpoint was freedom from syncope during follow-up. Secondary endpoints included device efficacy and safety estimated by device-related major and minor adverse events (AEs). RESULTS: Seventy-two patients (24 LP, 48 CTP; age 32 ± 5.5 years; 90% female; syncope frequency 7.6 ± 3.4 per year) were included. At 1 year, 91% of patients (22/24) in the LP group and 94% of patients (43/48) in the CTP group met the primary efficacy endpoint (P = .7). Device efficacy endpoint was met in 92% of the LP group and 98% of the CTP group (P = .2). Early major AEs occurred in 2 of 24 in the LP group and 3 of 48 in the CTP group (P = .4). Late major AEs occurred in 0 of 24 in the LP group and 2 of 48 in the CTP group (P = 1). CONCLUSION: In patients with CI-VVS, single-chamber LP demonstrated equivalent efficacy in reducing syncopal events compared to dual-chamber CTP, with a similar safety profile.


Assuntos
Estimulação Cardíaca Artificial/métodos , Marca-Passo Artificial , Síncope Vasovagal/terapia , Adulto , Feminino , Seguimentos , Humanos , Masculino , Recidiva , Estudos Retrospectivos , Síncope Vasovagal/diagnóstico , Síncope Vasovagal/fisiopatologia , Teste da Mesa Inclinada , Resultado do Tratamento , Adulto Jovem
4.
J Cardiovasc Electrophysiol ; 17(10): 1080-5, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16989649

RESUMO

BACKGROUND: Each of the two main approaches to catheter ablation of atrial fibrillation (AF, segmental and circumferential) is associated with moderate long-term efficacy. OBJECTIVE: To report the long-term outcomes of a modified technique that combines circumferential ablation with pulmonary vein (PV) isolation, determined by a circular mapping catheter and to determine the relationship between complete PV isolation and long-term efficacy. METHODS: The patient population was composed of 64 consecutive patients (47 men [73%]; age 59 +/- 11 years) with AF who underwent catheter ablation. AF was paroxysmal in 29 (45%) and nonparoxysmal in 35 (55%). Each patient was followed for a minimum of 12 months. RESULTS: After a mean follow-up of 13 +/- 1 months, the long-term single-procedure success rate was 45% (n = 29) with an additional 4% (n = 3) of patients demonstrating improvement. With repeat procedures in 19 patients, the overall long-term success rate was 62% (n = 40) with 9% (n = 6) demonstrating improvement. All the patients who underwent repeat ablations had recovered PV conduction. Incomplete PV isolation was the only independent predictor of failure. A major complication occurred in four (6%) patients, including three patients with vascular complications and one with cardiac tamponade. CONCLUSION: Our results suggest that the long-term single-procedure efficacy of circumferential ablation with PV isolation in a cohort of patients with predominantly nonparoxysmal AF approaches 50%. Repeat procedures involving re-isolation of the PVs result in a significant improvement in outcomes. Complete electrical isolation of the PVs has a significant impact on the long-term efficacy of the procedure.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/métodos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Cateterismo Cardíaco/efeitos adversos , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
5.
J Interv Card Electrophysiol ; 15(3): 145-55, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17019636

RESUMO

BACKGROUND: Two important limitations of the data regarding the outcomes of catheter ablation of atrial fibrillation (AF) are the short-term follow-up used in most published studies and the lack of single-procedure outcomes. OBJECTIVE: The objective was to report the long-term single-procedure outcomes at our center. MATERIALS AND METHODS: The patient population was comprised of 200 consecutive patients who underwent ablation (133 men; age 56 +/- 11 years). Atrial fibrillation was paroxysmal in 92 (46%). Success was defined as absence of symptomatic AF, off antiarrhythmic drug (AAD) after a single procedure. RESULTS: After a follow-up of 26 +/- 11 months, the single-procedure long-term success rate was 28% with an additional 7% of patients demonstrating improvement. After including repeat procedures in 64 patients, the overall long-term success rate was 41% with 11% demonstrating improvement. Further subgroup analysis of 48 paroxysmal AF patients considered to be optimal candidates for the procedure, revealed a long-term success rate of 69% with an additional 4% demonstrating improvement. A major complication occurred in 7.9% of patients. CONCLUSION: The results reveal that the long-term single-procedure success rate of catheter ablation of AF in a cohort of patients with predominantly non-paroxysmal AF is less than 40%. The inclusion of redo procedures resulted in an improvement in outcomes. A much higher success rate of 69% was achieved in patients with paroxysmal AF considered to be optimal candidates for this procedure. These results make it clear that further advances in the technique of catheter ablation of AF are needed to improve the safety and efficacy of this procedure. In order to be able to compare outcomes of various techniques in differing patient populations, we urge investigators to report long-term single procedure outcomes.


Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Medição de Risco/métodos , Ablação por Cateter/estatística & dados numéricos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Resultado do Tratamento , Estados Unidos/epidemiologia
6.
Am Heart J ; 150(6): 1276-81, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16338271

RESUMO

BACKGROUND: The Framingham risk estimation (FRE) serves as the basis for identifying which asymptomatic adults should be treated with aspirin and lipid-lowering therapy in primary prevention. However, the FRE generally yields low estimates of 10-year "hard" coronary heart disease (CHD) event risk with few women (< 70 years) qualifying for preventive pharmacologic therapy despite relatively high lifetime risk. We postulated that traditional risk factor assessment might fail to identify a sizeable portion of women with a sibling history for premature CHD as having advanced subclinical atherosclerosis. METHODS: We studied 102 asymptomatic women (mean age 51 +/- 7 years) who were the sisters of a proband hospitalized with documented premature CHD. Participants underwent risk factor assessment and multidetector computed tomography for coronary artery calcium (CAC) scoring. Based on FRE prediction of 10-year risk for hard CHD events, participants were classified as low risk (< 10%) (n = 100), intermediate risk (10%-20%) (n = 2), or high risk (> 20%) (n = 0). Significant subclinical atherosclerosis was defined as age-sex adjusted > 75th percentile CAC scores. RESULTS: Ninety-eight percent were at low risk (mean FRE of only 2% +/- 2%). However, 40% had detectable CAC, 12% had CAC > 100, and 6% had CAC > or = 400. Based on CAC score percentiles, 32% had significant subclinical atherosclerosis and 17% ranked above the 90th percentile. CONCLUSION: Among women classified as low risk by FRE, a third had significant subclinical atherosclerosis. Sisters of probands with premature CHD appear to be a high-risk group and may warrant noninvasive screening for subclinical atherosclerosis to appropriately target individuals for more aggressive primary prevention therapy than what is currently recommended.


Assuntos
Doença da Artéria Coronariana/epidemiologia , Doença das Coronárias/genética , Adulto , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/epidemiologia , Família , Feminino , Humanos , Massachusetts/epidemiologia , Pessoa de Meia-Idade , Prevalência , Medição de Risco , Fatores Socioeconômicos
7.
Heart Rhythm ; 2(1): 42-8, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15851264

RESUMO

OBJECTIVES: The purpose of this study was to report the safety, efficacy, and predictors of recurrence of circumferential pulmonary vein (PV) catheter ablation in patients with atrial fibrillation (AF). BACKGROUND: Circumferential PV ablation has been described as an alternate ablation strategy for AF. METHODS: Seventy consecutive patients (age 56 +/- 10 years) with symptomatic drug refractory paroxysmal (n = 21), persistent (n = 22), and permanent (n = 27) AF underwent catheter ablation. The catheter ablation procedure was performed by creating circular lesions encircling right- and left-side PV ostia guided by an electroanatomic (CARTO) mapping system. Linear ablation lesions also were created in the cavotricuspid isthmus, the mitral isthmus, and in the posterior left atrium. In 42 patients (60%), additions linear lesions were created between superior and inferior PVs in a "figure-of-eight" fashion. RESULTS: At 6 +/- 2.5 months of follow-up, 53 patients (76%) were AF free, including 39 patients (56%) not taking and 14 patients (20%) taking antiarrhythmic drugs. Among various variables, only early recurrence of AF was a predictor of long-term recurrence. Significant complications included one pericardial tamponade, one stroke, and two PV occlusions. Both patients with PV occlusion received radiofrequency delivery in a figure-of-eight fashion. CONCLUSIONS: Circumferential PV catheter ablation of AF is associated with moderate efficacy and risk of complications. The absence of a difference in efficacy combined with the risk of PV stenosis associated with figure-of-eight lesion lead us to conclude that the figure-of-eight lesion should not be a routine component of circumferential PV AF ablation procedures.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Veias Pulmonares , Recidiva , Segurança , Fatores de Tempo
8.
J Interv Card Electrophysiol ; 13(2): 107-14, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16133837

RESUMO

INTRODUCTION: Catheter ablation to achieve pulmonary vein (PV) isolation has become an increasingly used treatment strategy for patients with atrial fibrillation (AF). The purpose of this study was to evaluate the impact of segmental isolation of PVs on volume of left atrium and its relation to the decrease in the size of the pulmonary veins. METHODS: Gadolinium enhanced Magnetic Resonance Angiography (MRA) was performed in 51 AF patients before and 6 approximately 8 weeks post PV isolation, using cooled radio-frequency (RF) energy. Three-dimensional reconstruction with maximum intensity projections and multiplanar reformations was performed. Oblique coronal projections were used to measure the ostial size of PVs. Three orthogonal dimensions of LA chamber were measured and computed to assess the volume of the left atrium. RESULTS: The mean LA volume decreased by 15.7% after ablation (p<0.001). The mean PV ostial diameter decreased by 11%, from 18.3+/-0.8 mm to 16.7+/-1.0 mm (p=0.005). Moderate PV stenosis was noted in two veins out of the 192 veins analyzed. There was a significant correlation between changes in the size of PV ostium to that of the LA. CONCLUSIONS: Catheter ablation of AF using a segmental PV isolation approach results in a significant reverse remodeling in the left atrium. Significant stenosis of PVs appears to be rare after the segmental isolation procedure.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Angiografia por Ressonância Magnética , Veias Pulmonares/patologia , Pneumopatia Veno-Oclusiva/diagnóstico , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Veias Pulmonares/cirurgia , Resultado do Tratamento
9.
Prev Cardiol ; 8(3): 173-7, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16034221

RESUMO

Recent comparative trials of 3-hydroxy-3-methylglutaryl coenzyme A reductase inhibitors (statins) suggest that lower is better and that reducing low-density lipoprotein cholesterol (LDL-C) levels to below 100 mg/dL can provide additional clinical benefit. Non-high-density lipoprotein cholesterol (non-HDL-C) contains more atherogenic cholesterol than LDL-C and is considered a more accurate measurement of the total amount of atherogenic particles in the circulation. Therefore, the principle that "lower is better" may also apply to lowering levels of non-HDL-C. In persons with high triglycerides (200-499 mg/dL), LDL-C remains the primary target of therapy, but non-HDL-C is an important secondary therapeutic target. Non-HDL-C is strongly correlated with small dense LDL as well as apolipoprotein B, an established predictor of cardiovascular disease risk. Current evidence indicates that statins not only rapidly and dramatically reduce LDL-C, but also have a similar effect on non-HDL-C, and that the greater the reduction in LDL-C, the greater will be the reduction in non-HDL-C.


Assuntos
Anticolesterolemiantes/uso terapêutico , Arteriosclerose/sangue , HDL-Colesterol/sangue , Arteriosclerose/mortalidade , Arteriosclerose/prevenção & controle , Biomarcadores/sangue , HDL-Colesterol/efeitos dos fármacos , LDL-Colesterol/sangue , LDL-Colesterol/efeitos dos fármacos , Humanos , Fatores de Risco , Taxa de Sobrevida
10.
Heart Rhythm ; 1(1): 78-81, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-15851122

RESUMO

Favorable results of circumferential pulmonary vein (PV) ostial ablation guided by electroanatomic mapping (Carto) have fueled great enthusiasm for this technique. The lesion set for this ablation procedure as described by Pappone et al.(1,2) involves a figure of 8 lesions encompassing the 2 right and 2 left PV ostia with 2 additional linear lesions. Pulmonary vein stenosis/or occlusion has not previously been reported as a complication of this procedure. We describe PV occlusion after this procedure. Based on the occurrence of this previously unreported complication, we no longer create a figure '8' lesion around the right superior and inferior PVs. We anticipate that this complication can be avoided by creating a circular lesion encompassing the 2 PV ostia, while avoiding the linear lesion between the 2 PV ostia.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Veias Pulmonares/patologia , Pneumopatia Veno-Oclusiva/etiologia , Adulto , Ablação por Cateter/métodos , Constrição Patológica/etiologia , Humanos , Imageamento por Ressonância Magnética , Masculino
11.
Clin Sports Med ; 23(3): 455-71, x, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15262382

RESUMO

Cardiovascular disease (CVD) is the leading cause of death in the United States, resulting in increased awareness of the preventive importance of regular physical activity. Because athletes are considered physically fit, occurrence of sudden athlete death from CVD is perplexing. Regular intense physical activity can cause changes to the cardiovascular system that mimic known CVD processes. Therefore, screening of athletes for conditions that may increase risk for sudden cardiac death (SCD) is challenging. This article focuses on this problem, discussing the athlete's heart, SCD and associated CV conditions, and preparticipation screening. We also review recommendations of the 26th Bethesda Conference on determining eligibility for competition in athletes with known CV abnormalities, and how the recommendations relate to individual disease processes.


Assuntos
Doenças Cardiovasculares/fisiopatologia , Morte Súbita Cardíaca/etiologia , Esportes , Doenças Cardiovasculares/prevenção & controle , Humanos , Programas de Rastreamento , Exame Físico , Fatores de Risco , Medicina Esportiva
12.
J Cardiovasc Electrophysiol ; 17(2): 134-9, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16533249

RESUMO

INTRODUCTION: The goals of this study were to (i) evaluate the feasibility and results of monitoring patients prior to and following catheter ablation of AF with the mobile cardiac outpatient telemetry (MCOT) system and to (ii) correlate symptoms and the presence or absence of atrial fibrillation (AF). METHODS AND RESULTS: A total of 19 consecutive patients (12 men [63%]; age 60 +/- 6 years) with highly symptomatic drug refractory AF underwent catheter ablation. Each was provided with a MCOT monitor (CardioNet, USA) and asked to wear it 5 days immediately before the ablation, and 5 days per month starting with the ablation for 6 consecutive months. When patients experienced any symptoms, they were asked to activate the system and to record associated symptoms. A total of 494 days (11,856 hours) were monitored. Out of the total 390 events triggered by patient's symptoms, 40% were confirmed as AF events (156) and 60% were confirmed as non-AF events (234). Only shortness of breath and chest discomfort were highly associated with AF (P < 0.05). At the end of 6 months of follow-up, out of 10 patients that completed the study, 7 (70%) patients were free of symptomatic AF recurrences whereas only 5 (50%) patients achieved success when asymptomatic AF recurrences were included in the outcome. CONCLUSIONS: The results of this study demonstrate the potential utility of wireless monitoring systems in the follow-up of AF ablation patients, while also identifying poor patient compliance with an intensive monitoring protocol as an important limitation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Monitorização Fisiológica , Telemetria , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Cooperação do Paciente
13.
J Cardiovasc Electrophysiol ; 17(5): 459-66, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16684014

RESUMO

INTRODUCTION: No prior studies have reported the use of integrated electroanatomic mapping with preacquired magnetic resonance/computed tomographic (MR/CT) images to guide catheter ablation of atrial fibrillation (AF) in a series of patients. METHODS AND RESULTS: Sixteen consecutive patients with drug-refractory AF underwent catheter ablation under the guidance of a three-dimensional (3D) electroanatomic mapping system (Carto, Biosense Webster, Inc., Diamond Bar, CA, USA). Gadolinium-enhanced MR (n = 8) or contrast-enhanced high-resolution CT (n = 8) imaging was performed within 1 day prior to the ablation procedures. Using a novel software package (CartoMerge, Biosense Webster, Inc.), the left atrium (LA) with pulmonary veins (PVs) was segmented and extracted for image registration. The segmented 3D MR/CT LA reconstruction was accurately registered to the real-time mapping space with a combination of landmark registration and surface registration. The registered 3D MR/CT LA reconstruction was successfully used to guide deployment of RF applications encircling the PVs. Upon completion of the circumferential lesions around the PVs, 32% of the PVs were electrically isolated. Guided by a circular mapping catheter, the remaining PVs were disconnected from the LA using a segmental approach. The distance between the surface of the registered 3D MR/CT LA reconstruction and multiple electroanatomic map points was 3.05 +/- 0.41 mm. No complications were observed. CONCLUSIONS: Three-dimensional MR/CT images can be successfully extracted and registered to anatomically guided clinical AF ablations. The display of detailed and accurate anatomic information during the procedure enables tailored RF ablation to individual PV and LA anatomy.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Imageamento por Ressonância Magnética/métodos , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Técnica de Subtração , Resultado do Tratamento
14.
J Cardiovasc Electrophysiol ; 16(8): 845-52, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16101625

RESUMO

INTRODUCTION: There are currently no studies systematically evaluating pulmonary vein (PV) stenosis following catheter ablation of atrial fibrillation (AF) using the anatomic PV ablation approach. METHODS AND RESULTS: Forty-one patients with AF underwent anatomic PV ablation under the guidance of a three-dimensional electroanatomic mapping system. Gadolinium-enhanced magnetic resonance (MR) imaging was performed in all patients prior to and 8-10 weeks after ablation procedures for screening of PV stenosis. A PV stenosis was defined as a detectable (> or =3 mm) narrowing in PV diameter. The severity of stenosis was categorized as mild (<50% stenosis), moderate (50-70%), or severe (>70%). A total 157 PVs were analyzed. A detectable PV narrowing was observed in 60 of 157 PVs (38%). The severity of stenosis was mild in 54 PVs (34%), moderate in five PVs (3.2%), and severe in one PV (0.6%). All mild PV stenoses displayed a concentric pattern. Moderate or severe PV stenosis was only observed in patients with an individual encircling lesion set. Multivariable analysis identified individual encircling lesion set and larger PV size as the independent predictors of detectable PV narrowing. All patients with PV stenosis were asymptomatic and none required treatment. CONCLUSIONS: The results of this study demonstrate that detectable PV narrowing occurs in 38% of PVs following anatomic PV ablation. Moderate or severe PV stenosis occurs in 3.8% of PVs. The high incidence of mild stenosis likely reflects reverse remodeling rather than pathological PV stenosis. The probability of moderate or severe PV stenosis appears to be related to creation of individual encircling rather than encircling in pairs lesion.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Pneumopatia Veno-Oclusiva/etiologia , Adulto , Idoso , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Incidência , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/patologia
15.
J Cardiovasc Electrophysiol ; 16(6): 582-8, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15946353

RESUMO

INTRODUCTION: Anatomically guided left atrial ablation is used increasingly for treatment of atrial fibrillation (AF). Three-dimensional mapping systems used for pulmonary veins (PV) encircling ablation procedures anticipate a stable size and position of the PV orifice. The aim of the current study was therefore to analyze changes of PV orifice size and location throughout the cardiac cycle using cine magnetic resonance imaging (MRI). METHODS AND RESULTS: Twenty-five healthy volunteers were studied using a 1.5 Tesla MRI system. MR angiograms were acquired with a breath-hold three-dimensional fast-spoiled gradient-echo imaging (3D FSPGR) sequence in the coronal plane before and after gadolinium injection. Maximum intensity projections and multiplanar reformations were performed to reconstruct images of the PV. Bright blood cine imaging in the axial view was acquired by a steady-state free precession pulse sequence. Twenty bright blood images were obtained per cardiac cycle. The axial (anterior-posterior) PV orifice diameter was measured in all 20 images. For analysis of PV movement the location of the orifice posterior edge was plotted on scale paper. PV orifice size depends on the stage of the cardiac cycle with the largest diameter in late atrial diastole and a mean decrease of 32.5% during atrial systole. Location changes of the PV orifice are in the range of up to 7.2 mm and larger in the coronal (lateral-medial) than in the sagittal (anterior-posterior) direction. CONCLUSION: PV orifice size and location is not as stable as anticipated by three-dimensional mapping systems used for PV encircling left atrial ablation procedures. RF application close to the presumed orifice location should therefore be avoided to minimize the risk of PV stenosis.


Assuntos
Função Atrial/fisiologia , Imagem Cinética por Ressonância Magnética , Veias Pulmonares/anatomia & histologia , Veias Pulmonares/fisiologia , Adulto , Fibrilação Atrial , Ablação por Cateter , Meios de Contraste , Angiografia Coronária , Feminino , Gadolínio , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Modelos Anatômicos , Modelos Teóricos , Estudos Prospectivos , Fatores de Tempo
16.
Am Heart Hosp J ; 2(4): 191-7, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15538052

RESUMO

Metabolic syndrome is a cluster of risk factors for cardiovascular disease that include obesity, atherogenic dyslipidemia, raised blood pressure, and insulin resistance. The growing trend of obesity is associated with increased prevalence of metabolic syndrome. Optimizing diet and exercise are still the leading therapy for controlling the metabolic syndrome. Based on the current evidence, further emphasis should be placed on aggressive management of other metabolic risk factors such as high blood pressure and dyslipidemia.


Assuntos
Síndrome Metabólica/prevenção & controle , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Dieta , Exercício Físico , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Hipoglicemiantes/uso terapêutico , Inibidores da Agregação Plaquetária/uso terapêutico , Abandono do Hábito de Fumar
17.
J Cardiovasc Electrophysiol ; 15(5): 538-43, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-15149422

RESUMO

INTRODUCTION: Catheter ablation of the pulmonary veins (PVs) for prevention of recurrent atrial fibrillation requires precise anatomic information. We describe the characteristics of a new anatomic variant of PV anatomy using magnetic resonance angiography. METHODS AND RESULTS: A 1.5-T magnetic resonance imaging system with a body coil or a torso phased-array coil was used before and after gadolinium injection. Magnetic resonance angiograms were acquired with a breath-hold three-dimensional fast spoiled gradient-echo imaging sequence in the coronal plane. Three-dimensional reconstruction with maximum intensity projections and multiplanar reformations was performed. A newly described variant PV ascending from the roof of the left atrium was found in 3 of 91 subjects. The mean ostial diameter of the roof PV was 7 +/- 2 mm, the mean distance from the ostium to the first branching point was 22 +/- 8.5 mm, and the mean distance to the right superior PV was 3.3 +/- 0.6 mm. CONCLUSION: We refer to the newly described variant of PV anatomy as the "right top pulmonary vein." It is important to be aware of this anatomic pattern to avoid inadvertent catheter intubation, which can result in misleading mapping results and PV stenosis.


Assuntos
Fibrilação Atrial/patologia , Angiografia por Ressonância Magnética/métodos , Veias Pulmonares/anormalidades , Veias Pulmonares/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Feminino , Átrios do Coração/patologia , Átrios do Coração/cirurgia , Humanos , Incidência , Angiografia por Ressonância Magnética/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Estados Unidos
18.
J Cardiovasc Electrophysiol ; 15(6): 692-7, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15175066

RESUMO

INTRODUCTION: The aims of this study were to identify predictors of recurrence after catheter ablation of atrial fibrillation (AF) and to report the safety and efficacy of catheter ablation of AF using an irrigated-tip ablation catheter. METHODS AND RESULTS: Seventy-five consecutive patients (51 men [68%]; age 54 +/- 13 years) with symptomatic drug-refractory paroxysmal (42 patients), persistent (21 patients), or permanent (12 patients) AF underwent catheter ablation of AF using an irrigated-tip ablation catheter and a standard ablation strategy, which involved electrical isolation of all pulmonary veins (PVs) and creation of a cavotricuspid linear lesion. At 10.5 +/- 7.5 months of follow-up following a single (n = 75) or redo ablation procedure (n = 11), 39 (52%) of the 75 patients were free of AF, 10 were improved (13%), and 26 had experienced no benefit from the ablation procedure (35%). Seventy-six percent of patients with paroxysmal AF were free from recurrent AF. The most significant complications were two episodes of pericardial tamponade, mitral valve injury in one patient, two strokes, and complete but asymptomatic PV stenosis in one patient. Cox proportional hazards multivariate regression analysis identified the presence of persistent AF, permanent AF, and age >50 years prior to the ablation are the only independent predictors of AF recurrence after the first PV isolation procedure. CONCLUSION: Catheter ablation of AF using a strategy involving isolation of all PVs and creation of a linear lesion in the cavotricuspid isthmus using cooled radiofrequency energy is associated with moderate efficacy and an important risk for complications. The best results of this procedure are achieved in the subset of patients who are younger than 50 years and have only paroxysmal AF.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/instrumentação , Complicações Pós-Operatórias/etiologia , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Cateteres de Demora , Ecocardiografia Transesofagiana , Desenho de Equipamento/instrumentação , Feminino , Seguimentos , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Complicações Pós-Operatórias/diagnóstico , Valor Preditivo dos Testes , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA