Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 355
Filtrar
1.
N Engl J Med ; 388(2): 105-116, 2023 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-36342178

RESUMO

BACKGROUND: Atrial fibrillation is a chronic, progressive disorder, and persistent forms of atrial fibrillation are associated with increased risks of thromboembolism and heart failure. Catheter ablation as initial therapy may modify the pathogenic mechanism of atrial fibrillation and alter progression to persistent atrial fibrillation. METHODS: We report the 3-year follow-up of patients with paroxysmal, untreated atrial fibrillation who were enrolled in a trial in which they had been randomly assigned to undergo initial rhythm-control therapy with cryoballoon ablation or to receive antiarrhythmic drug therapy. All the patients had implantable loop recorders placed at the time of trial entry, and evaluation was conducted by means of downloaded daily recordings and in-person visits every 6 months. Data regarding the first episode of persistent atrial fibrillation (lasting ≥7 days or lasting 48 hours to 7 days but requiring cardioversion for termination), recurrent atrial tachyarrhythmia (defined as atrial fibrillation, flutter, or tachycardia lasting ≥30 seconds), the burden of atrial fibrillation (percentage of time in atrial fibrillation), quality-of-life metrics, health care utilization, and safety were collected. RESULTS: A total of 303 patients were enrolled, with 154 patients assigned to undergo initial rhythm-control therapy with cryoballoon ablation and 149 assigned to receive antiarrhythmic drug therapy. Over 36 months of follow-up, 3 patients (1.9%) in the ablation group had an episode of persistent atrial fibrillation, as compared with 11 patients (7.4%) in the antiarrhythmic drug group (hazard ratio, 0.25; 95% confidence interval [CI], 0.09 to 0.70). Recurrent atrial tachyarrhythmia occurred in 87 patients in the ablation group (56.5%) and in 115 in the antiarrhythmic drug group (77.2%) (hazard ratio, 0.51; 95% CI, 0.38 to 0.67). The median percentage of time in atrial fibrillation was 0.00% (interquartile range, 0.00 to 0.12) in the ablation group and 0.24% (interquartile range, 0.01 to 0.94) in the antiarrhythmic drug group. At 3 years, 8 patients (5.2%) in the ablation group and 25 (16.8%) in the antiarrhythmic drug group had been hospitalized (relative risk, 0.31; 95% CI, 0.14 to 0.66). Serious adverse events occurred in 7 patients (4.5%) in the ablation group and in 15 (10.1%) in the antiarrhythmic drug group. CONCLUSIONS: Initial treatment of paroxysmal atrial fibrillation with catheter cryoballoon ablation was associated with a lower incidence of persistent atrial fibrillation or recurrent atrial tachyarrhythmia over 3 years of follow-up than initial use of antiarrhythmic drugs. (Funded by the Cardiac Arrhythmia Network of Canada and others; EARLY-AF ClinicalTrials.gov number, NCT02825979.).


Assuntos
Antiarrítmicos , Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Humanos , Antiarrítmicos/efeitos adversos , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Recidiva , Taquicardia/etiologia , Resultado do Tratamento , Progressão da Doença , Seguimentos
2.
Circulation ; 147(19): 1422-1432, 2023 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-36877118

RESUMO

BACKGROUND: Pulsed field ablation uses electrical pulses to cause nonthermal irreversible electroporation and induce cardiac cell death. Pulsed field ablation may have effectiveness comparable to traditional catheter ablation while preventing thermally mediated complications. METHODS: The PULSED AF pivotal study (Pulsed Field Ablation to Irreversibly Electroporate Tissue and Treat AF) was a prospective, global, multicenter, nonrandomized, paired single-arm study in which patients with paroxysmal (n=150) or persistent (n=150) symptomatic atrial fibrillation (AF) refractory to class I or III antiarrhythmic drugs were treated with pulsed field ablation. All patients were monitored for 1 year using weekly and symptomatic transtelephonic monitoring; 3-, 6-, and 12-month ECGs; and 6- and 12-month 24-hour Holter monitoring. The primary effectiveness end point was freedom from a composite of acute procedural failure, arrhythmia recurrence, or antiarrhythmic escalation through 12 months, excluding a 3-month blanking period to allow recovery from the procedure. The primary safety end point was freedom from a composite of serious procedure- and device-related adverse events. Kaplan-Meier methods were used to evaluate the primary end points. RESULTS: Pulsed field ablation was shown to be effective at 1 year in 66.2% (95% CI, 57.9 to 73.2) of patients with paroxysmal AF and 55.1% (95% CI, 46.7 to 62.7) of patients with persistent AF. The primary safety end point occurred in 1 patient (0.7%; 95% CI, 0.1 to 4.6) in both the paroxysmal and persistent AF cohorts. CONCLUSIONS: PULSED AF demonstrated a low rate of primary safety adverse events (0.7%) and provided effectiveness consistent with established ablation technologies using a novel irreversible electroporation energy to treat patients with AF. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT04198701.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Estudos Prospectivos , Resultado do Tratamento , Antiarrítmicos/uso terapêutico , Eletrocardiografia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
3.
Lancet ; 402(10396): 118-128, 2023 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-37331368

RESUMO

BACKGROUND: Etripamil is a fast-acting, intranasally administered calcium-channel blocker in development for on-demand therapy outside a health-care setting for paroxysmal supraventricular tachycardia. We aimed to evaluate the efficacy and safety of etripamil 70 mg nasal spray using a symptom-prompted, repeat-dose regimen for acute conversion of atrioventricular-nodal-dependent paroxysmal supraventricular tachycardia to sinus rhythm within 30 min. METHODS: RAPID was a multicentre, randomised, placebo-controlled, event-driven trial, conducted at 160 sites in North America and Europe as part 2 of the NODE-301 study. Eligible patients were aged at least 18 years and had a history of paroxysmal supraventricular tachycardia with sustained, symptomatic episodes (≥20 min) as documented by electrocardiogram. Patients were administered two test doses of intranasal etripamil (each 70 mg, 10 min apart) during sinus rhythm; those who tolerated the test doses were randomly assigned (1:1) using an interactive response technology system to receive either etripamil or placebo. Prompted by symptoms of paroxysmal supraventricular tachycardia, patients self-administered a first dose of intranasal 70 mg etripamil or placebo and, if symptoms persisted beyond 10 min, a repeat dose. Continuously recorded electrocardiographic data were adjudicated, by individuals masked to patient assignment, for the primary endpoint of time to conversion of paroxysmal supraventricular tachycardia to sinus rhythm for at least 30 s within 30 min after the first dose, which was measured in all patients who administered blinded study drug for a confirmed atrioventricular-nodal-dependent event. Safety outcomes were assessed in all patients who self-administered blinded study drug for an episode of perceived paroxysmal supraventricular tachycardia. This trial is registered at ClinicalTrials.gov, NCT03464019, and is complete. FINDINGS: Between Oct 13, 2020, and July 20, 2022, among 692 patients randomly assigned, 184 (99 from the etripamil group and 85 from the placebo group) self-administered study drug for atrioventricular-nodal-dependent paroxysmal supraventricular tachycardia, with diagnosis and timing confirmed. Kaplan-Meier estimates of conversion rates by 30 min were 64% (63/99) with etripamil and 31% (26/85) with placebo (hazard ratio 2·62; 95% CI 1·66-4·15; p<0·0001). Median time to conversion was 17·2 min (95% CI 13·4-26·5) with the etripamil regimen versus 53·5 min (38·7-87·3) with placebo. Prespecified sensitivity analyses of the primary assessment were conducted to test robustness, yielding supporting results. Treatment-emergent adverse events occurred in 68 (50%) of 99 patients treated with etripamil and 12 (11%) of 85 patients in the placebo group, most of which were located at the administration site and were mild or moderate, and all of which were transient and resolved without intervention. Adverse events occurring in at least 5% of patients treated with etripamil were nasal discomfort (23%), nasal congestion (13%), and rhinorrhea (9%). No serious etripamil-related adverse events or deaths were reported. INTERPRETATION: Using a symptom-prompted, self-administered, initial and optional-repeat-dosing regimen, intranasal etripamil was well tolerated, safe, and superior to placebo for the rapid conversion of atrioventricular-nodal-dependent paroxysmal supraventricular tachycardia to sinus rhythm. This approach could empower patients to treat paroxysmal supraventricular tachycardia themselves outside of a health-care setting, and has the potential to reduce the need for additional medical interventions, such as intravenous medications given in an acute-care setting. FUNDING: Milestone Pharmaceuticals.


Assuntos
Taquicardia Paroxística , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Adolescente , Adulto , Taquicardia Supraventricular/tratamento farmacológico , Taquicardia Paroxística/tratamento farmacológico , Benzoatos/uso terapêutico , Método Duplo-Cego
4.
N Engl J Med ; 384(4): 305-315, 2021 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-33197159

RESUMO

BACKGROUND: Guidelines recommend a trial of one or more antiarrhythmic drugs before catheter ablation is considered in patients with atrial fibrillation. However, first-line ablation may be more effective in maintaining sinus rhythm. METHODS: We randomly assigned 303 patients with symptomatic, paroxysmal, untreated atrial fibrillation to undergo catheter ablation with a cryothermy balloon or to receive antiarrhythmic drug therapy for initial rhythm control. All the patients received an implantable cardiac monitoring device to detect atrial tachyarrhythmia. The follow-up period was 12 months. The primary end point was the first documented recurrence of any atrial tachyarrhythmia (atrial fibrillation, atrial flutter, or atrial tachycardia) between 91 and 365 days after catheter ablation or the initiation of an antiarrhythmic drug. The secondary end points included freedom from symptomatic arrhythmia, the atrial fibrillation burden, and quality of life. RESULTS: At 1 year, a recurrence of atrial tachyarrhythmia had occurred in 66 of 154 patients (42.9%) assigned to undergo ablation and in 101 of 149 patients (67.8%) assigned to receive antiarrhythmic drugs (hazard ratio, 0.48; 95% confidence interval [CI], 0.35 to 0.66; P<0.001). Symptomatic atrial tachyarrhythmia had recurred in 11.0% of the patients who underwent ablation and in 26.2% of those who received antiarrhythmic drugs (hazard ratio, 0.39; 95% CI, 0.22 to 0.68). The median percentage of time in atrial fibrillation was 0% (interquartile range, 0 to 0.08) with ablation and 0.13% (interquartile range, 0 to 1.60) with antiarrhythmic drugs. Serious adverse events occurred in 5 patients (3.2%) who underwent ablation and in 6 patients (4.0%) who received antiarrhythmic drugs. CONCLUSIONS: Among patients receiving initial treatment for symptomatic, paroxysmal atrial fibrillation, there was a significantly lower rate of atrial fibrillation recurrence with catheter cryoballoon ablation than with antiarrhythmic drug therapy, as assessed by continuous cardiac rhythm monitoring. (Funded by the Cardiac Arrhythmia Network of Canada and others; EARLY-AF ClinicalTrials.gov number, NCT02825979.).


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Adulto , Idoso , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/prevenção & controle , Flutter Atrial , Ablação por Cateter/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Modelos de Riscos Proporcionais , Qualidade de Vida , Recidiva , Prevenção Secundária , Método Simples-Cego , Taquicardia
5.
Curr Opin Cardiol ; 39(1): 27-32, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-37712587

RESUMO

PURPOSE OF REVIEW: This review highlights pulse field ablation's (PFA) significance in treating atrial fibrillation. PFA uses short-pulsed electrical fields, offering safety advantages over thermal methods. Multicenter studies' findings on PFA's safety, efficiency, and efficacy, compared with thermal techniques, are discussed. RECENT FINDINGS: The review encompasses major PFA systems utilized in multicenter studies: penta-spline, circular, and lattice catheters. These studies affirm PFA's safety, with minimal complications like esophageal injury, phrenic nerve complications, and pulmonary vein stenosis. PFA also demonstrates procedural efficiency benefits because of rapid pulse delivery. However, PFA's efficacy appears on par with thermal ablation, showing similar rates of atrial arrhythmia recurrence during follow-up periods. The studies explore diverse postablation monitoring strategies, underscoring the necessity for standardized monitoring or consistent transformation of arrhythmia data. SUMMARY: In conclusion, PFA marks a promising era for atrial fibrillation treatment with improved safety and efficiency. Efficacy is comparable to thermal methods, though technology advancements could alter this. PFA's potential as a safer and faster alternative positions it as a dominant atrial fibrillation ablation technology. Careful analysis and standardized monitoring are vital to assess PFA's potential and clinical implications.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Tetranitrato de Pentaeritritol , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Terapia de Eletroporação Irreversível , Frequência Cardíaca , Resultado do Tratamento , Veias Pulmonares/cirurgia
6.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38582974

RESUMO

AIMS: The ultra-low-temperature cryoablation (ULTC) ablation system using -196°C N2 cryogen has been reported to create lesions with freeze duration-dependent depth titratable to over 10 mm with minimum attenuation by scar. Cryocure-VT (NCT04893317) was a first-in-human clinical trial evaluating the safety and efficacy of a novel, purpose-built ULTC catheter in endocardial ablation of scar-dependent ventricular tachycardias (VTs). METHODS AND RESULTS: This prospective, multi-centre study enrolled patients referred for de novo or second ablations of recurrent monomorphic VT of both ischaemic and non-ischaemic aetiologies. Primary safety and efficacy endpoints of the study were freedom from device- or procedure-related major adverse events (MAEs) up to 30 days post-ablation, acute non-inducibility of clinical VTs at the end of the procedure, and freedom from sustained VT or implantable defibrillator intervention at 6 months. Ultra-low-temperature cryoablation was performed in 64 patients (age 67 ± 11 years, 78% ischaemic, ejection fraction = 35 ± 10%) at 9 centres. The primary acute effectiveness endpoint was achieved in 94% (51/54) of patients in whom post-ablation induction was attempted. There were no protocol-defined MAEs; four procedure-related serious adverse events resolved without clinical sequelae. At 6-month follow-up, 38 patients (60.3%) remained VT-free, and freedom from defibrillator shock was 81.0%, with no significant difference between ischaemic and non-ischaemic cohorts. In 47 patients with defibrillator for at least 6 months prior to the ablation, the VT burden was reduced from median of 4, inter-quartile range (IQR, 1-9) to 0, IQR (0-2). CONCLUSION: In this first-in-human multi-centre experience, endocardial ULTC ablation of monomorphic VT appears safe and effective in patients with both ischaemic-cardiomyopathy and non-ischaemic-cardiomyopathy. CLINICAL TRIAL REGISTRATION: NCT04893317.


Assuntos
Cardiomiopatias , Ablação por Cateter , Criocirurgia , Taquicardia Ventricular , Idoso , Humanos , Pessoa de Meia-Idade , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Cardiomiopatias/cirurgia , Ablação por Cateter/efeitos adversos , Cicatriz/complicações , Criocirurgia/efeitos adversos , Estudos Prospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Temperatura , Resultado do Tratamento
7.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38587017

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , América Latina , Resultado do Tratamento , Catéteres , Ásia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
8.
J Immunol ; 209(1): 128-135, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35705254

RESUMO

Postinfluenza bacterial pneumonia is a significant cause of hospitalization and death in humans. The mechanisms underlying this viral and bacterial synergy remain incompletely understood. Recent evidence indicates that influenza-induced IFNs, particularly type I IFN (IFN-I) and IFN-γ, suppress antibacterial defenses. In this study, we have investigated the relative importance and interplay of IFN-I and IFN-γ pathways in influenza-induced susceptibility to Streptococcus pneumoniae infection. Using gene-deficient mouse models, as well as in vivo blocking Abs, we show that both IFN-I and IFN-γ signaling pathways contribute to the initial suppression of antibacterial immunity; however, IFN-γ plays a dominant role in the disease deterioration, in association with increased TNF-α production and alveolar macrophage (AM) depletion. We have previously shown that IFN-γ impairs AM antibacterial function and thereby acute bacterial clearance. The findings in this study indicate that IFN-γ signaling also impairs AM viability and αß T cell recruitment during the progression of influenza/S. pneumoniae coinfection. Macrophages insensitive to IFN-γ mice express a dominant-negative mutant IFN-γR in mononuclear phagocytes. Interestingly, macrophages insensitive to IFN-γ mice exhibited significantly improved recovery and survival from coinfection, despite delayed bacterial clearance. Importantly, we demonstrate that IFN-I receptor signaling is essential for preventing IFN-γ hyperproduction and animal death during the progression of postinfluenza pneumococcal pneumonia.


Assuntos
Coinfecção , Influenza Humana , Interferon Tipo I/metabolismo , Infecções por Orthomyxoviridae , Infecções Pneumocócicas , Pneumonia Pneumocócica , Animais , Antibacterianos , Humanos , Interferon gama , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout
9.
Environ Res ; 241: 117656, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37980987

RESUMO

The topic of photocatalysis and CuxO-based materials has been intertwined for quite a long time. Its relatively high abundance in the earth's crust makes it an important target for researchers around the globe. One of the properties exploited by researchers is its ability to exist in different oxidation states (Cu0, Cu+, Cu2+, and Cu3+) and its implications on photocatalytic efficiency improvement. Recently, they have been extensively used as photocatalytic materials for dye and pollutant degradation. However, it has almost reached saturation levels, therefore, currently, they are being mostly utilized for CO2 reduction and H2 evolution. Hence, this review will discuss the evolution (in application) of CuxO-based photocatalysts, relating to their past, present, and future. Moreover, photocatalytic efficiency improvement strategies such as doping, heterojunction formation, and carbonaceous construction with other materials will also be touched upon. Finally, the prospect of Cu2O-based photocatalysts will be discussed in the field of photocatalytic N2 fixation to ammonia. The significance of N2 chemisorption on photocatalysts to maximize ammonia production will also be given importance.


Assuntos
Amônia , Poluentes Ambientais , Dióxido de Carbono , Fixação de Nitrogênio
10.
Circulation ; 145(23): 1693-1704, 2022 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-35313733

RESUMO

BACKGROUND: Atrial fibrillation (AF) and heart failure (HF) frequently coexist and can be challenging to treat. Pharmacologically based rhythm control of AF has not proven to be superior to rate control. Ablation-based rhythm control was compared with rate control to evaluate if clinical outcomes in patients with HF and AF could be improved. METHODS: This was a multicenter, open-label trial with blinded outcome evaluation using a central adjudication committee. Patients with high-burden paroxysmal (>4 episodes in 6 months) or persistent (duration <3 years) AF, New York Heart Association class II to III HF, and elevated NT-proBNP (N-terminal pro brain natriuretic peptide) were randomly assigned to ablation-based rhythm control or rate control. The primary outcome was a composite of all-cause mortality and all HF events, with a minimum follow-up of 2 years. Secondary outcomes included left ventricular ejection fraction, 6-minute walk test, and NT-proBNP. Quality of life was measured using the Minnesota Living With Heart Failure Questionnaire and the AF Effect on Quality of Life. The primary analysis was time-to-event using Cox proportional hazards modeling. The trial was stopped early because of a determination of apparent futility by the Data Safety Monitoring Committee. RESULTS: From December 1, 2011, to January 20, 2018, 411 patients were randomly assigned to ablation-based rhythm control (n=214) or rate control (n=197). The primary outcome occurred in 50 (23.4%) patients in the ablation-based rhythm-control group and 64 (32.5%) patients in the rate-control group (hazard ratio, 0.71 [95% CI, 0.49-1.03]; P=0.066). Left ventricular ejection fraction increased in the ablation-based group (10.1±1.2% versus 3.8±1.2%, P=0.017), 6-minute walk distance improved (44.9±9.1 m versus 27.5±9.7 m, P=0.025), and NT-proBNP demonstrated a decrease (mean change -77.1% versus -39.2%, P<0.0001). Minnesota Living With Heart Failure Questionnaire demonstrated greater improvement in the ablation-based rhythm-control group (least-squares mean difference of -5.4 [95% CI, -10.5 to -0.3]; P=0.0036), as did the AF Effect on Quality of Life score (least-squares mean difference of 6.2 [95% CI, 1.7-10.7]; P=0.0005). Serious adverse events were observed in 50% of patients in both treatment groups. CONCLUSIONS: In patients with high-burden AF and HF, there was no statistical difference in all-cause mortality or HF events with ablation-based rhythm control versus rate control; however, there was a nonsignificant trend for improved outcomes with ablation-based rhythm control over rate control. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT01420393.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia , Humanos , Qualidade de Vida , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
11.
J Cardiovasc Electrophysiol ; 34(1): 99-107, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36335638

RESUMO

OBJECTIVES: Pulsed electric field (PEF) therapies employ punctuated energy delivery to kill cells in a volume of tissue through mechanisms that are not dependent on thermal processes. A key component to successful cardiac ablation procedures is ensuring the generation of transmural, contiguous ablation zones, which requires in-depth knowledge regarding treatment sizes for a given therapeutic application. METHODS: In this study, a series of acute treatments were delivered to porcine ventricles, where triphenyl tetrazolium chloride (TTC) vitality stain was used to identify treatment effect sizes for the three focal monopolar CENTAURI PEF cardiac ablation energy settings. RESULTS: Treatment depths were 5.7, 7.2, and 8.2 mm for the 19, 22, and 25 A energy settings, respectively. Gross pathology indicated umbral zones of hemorrhage surrounded by pale avital TTC-negative-negative tissue, which contrasted significantly from radiofrequency ablation (RF) controls. Histologically, treatment zones are identified by regions of contraction band necrosis and cardiomyocytolysis, which contrasted with RF control lesions composed primarily of coagulation necrosis. CONCLUSIONS: Together, these data indicate the ability for focal monopolar PEF treatments to generate deep treatment zones in cardiac ablation without incurring the gross or histological coagulative characteristics of RF thermal lesions.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Suínos , Animais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Necrose , Catéteres , Ventrículos do Coração
12.
J Cardiovasc Electrophysiol ; 34(10): 2124-2133, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36218014

RESUMO

BACKGROUND: Combining pulsed field ablation (PFA) with ultra-low temperature cryoablation (ULTC) represents a novel energy source which may create more transmural cardiac lesions. We sought to assess the feasibility of lesions created by combined cryoablation and pulsed field ablation (PFCA) versus PFA alone. METHODS: Ablations were performed using a custom PFA generator, ULTC console, and an ablation catheter with insertable stylets. PFA was delivered in a biphasic, bipolar train. PFCA precooled the tissue for 30 s followed by a concurrent PFA train. Benchtop testing using Schlieren imaging and microbubble volume assessment were used to compare PFA and PFCA. PFA and PFCA lesions using pre-optimized and optimized ablation protocols were studied in 6 swine. Pre and post-ECGs were recorded for each ablation and a gross necropsy was performed at 14 days. RESULTS: Consistent with benchtop comparisons of heat and microbubble generation, PFA deliveries in the animals were accompanied by muscle contractions and significant microbubbles (Grade 2-3) visible on intracardiac echo while neither occurred during PFCA at higher voltage levels. Both PFA and PFCA acutely eliminated or highly attenuated (>80%) local atrial electrograms. Histology of PFA and PFCA lesions indicated depth up to 6-7 mm and nearly all lesions were transmural. Optimized PFCA produced wider cavotricuspid isthmus lesions with evidence of tissue selectivity. CONCLUSION: A novel technology combining PFA and ULTC into one energy source demonstrated in-vivo feasibility for PFCA ablation. PFCA had a more favorable thermal profile and did not produce muscle contraction or microbubbles while extending lesion depth beyond cryoablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Suínos , Animais , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Temperatura , Temperatura Baixa , Átrios do Coração , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia
13.
J Cardiovasc Electrophysiol ; 34(3): 693-699, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36640426

RESUMO

INTRODUCTION: Contact force has been used to titrate lesion formation for radiofrequency ablation. Pulsed field ablation (PFA) is a field-based ablation technology for which limited evidence on the impact of contact force on lesion size is available. METHODS: Porcine hearts (n = 6) were perfused using a modified Langendorff set-up. A prototype focal PFA catheter attached to a force gauge was held perpendicular to the epicardium and lowered until contact was made. Contact force was recorded during each PFA delivery. Matured lesions were cross-sectioned, stained, and the lesion dimensions measured. RESULTS: A total of 82 lesions were evaluated with contact forces between 1.3 and 48.6 g. Mean lesion depth was 4.8 ± 0.9 mm (standard deviation), mean lesion width was 9.1 ± 1.3 mm, and mean lesion volume was 217.0 ± 96.6 mm3 . Linear regression curves showed an increase of only 0.01 mm in depth (depth = 0.01 × contact force + 4.41, R2 = 0.05), 0.03 mm in width (width = 0.03 × contact force + 8.26, R2 = 0.13) for each additional gram of contact force, and 2.20 mm3 in volume (volume = 2.20 × contact force + 162, R2 = 0.10). CONCLUSION: Increasing contact force using a bipolar, biphasic focal PFA system has minimal effects on acute lesion dimensions in an isolated porcine heart model and achieving tissue contact is more important than the force with which that contact is made.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Suínos , Animais , Ablação por Cateter/métodos , Ablação por Radiofrequência/métodos , Pericárdio , Catéteres , Irrigação Terapêutica
14.
Chemistry ; 29(68): e202302559, 2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-37806958

RESUMO

The field of photocatalysis has been evolving since 1972 since Honda and Fujishima's initial push for using light as an energy source to accomplish redox reactions. Since then, many photocatalysts have been studied, semiconductors or otherwise. A new photocatalytic application to convert N2 gas to ammonia (N2 fixation or nitrogen reduction reaction; NRR) has emerged. Many researchers have steered their research in this direction due to developments in the ease of ammonia detection through UV-Vis spectroscopy. This concept will specifically discuss Bi2 WO6 -based materials, techniques to enhance their photocatalytic activity (CO2 reduction, H2 production, pollutant removal, etc.), and their current application in photocatalytic NRR. Initially, a brief introduction of Bi2 WO6 along with its VB and CB potentials will be compared to various redox potentials. A final topic of interest would be a brief description of photocatalytic nitrogen fixation with additional consideration to Bi2 WO6 -based materials in N2 fixation. A major problem with photocatalytic NRR is the false ammonia quantification in Bi-based materials, which will be discussed in detail and also ways to minimize them.

15.
Mol Pharm ; 20(1): 738-749, 2023 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-36485036

RESUMO

Peptide stability to proteases has been a major requirement for developing peptide therapeutics. This study investigates the effects of peptide stability on antimicrobial and antibiofilm activity under various conditions. For this purpose, two human cathelicidin-derived peptides differing in stability to proteases were utilized. While GF-17, a peptide derived from the major antimicrobial region of human LL-37, can be rapidly cleaved by proteases, the engineered peptide 17BIPHE2 is resistant to multiple proteases. In the standard antimicrobial susceptibility, killing kinetics, and membrane permeabilization assays conducted in vitro using planktonic bacteria, these two peptides displayed similar potency. The two peptides were also similarly active against methicillin-resistant Staphylococcus aureus (MRSA) USA300 prior to biofilm formation. However, 17BIPHE2 was superior to GF-17 in disrupting preformed biofilms probably due to both enhanced stability and slightly higher DNA binding capacity. In a wax moth model, 17BIPHE2 better protected insects from MRSA infection-caused death than GF-17, consistent with the slower degradation of 17BIPHE2 than GF-17. Here, peptide antimicrobial activity was found to be critical for in vivo efficacy. When incorporated in the nanofiber/microneedle delivery device, GF-17 and 17BIPHE2 displayed a similar effect in eliminating MRSA in murine chronic wounds, underscoring the advantage of nanofibers in protecting the peptide from degradation. Since nanoformulation can ease the requirement of peptide stability, it opens the door to a direct use of natural peptides or their cocktails for antimicrobial treatment, accelerating the search of effective antibiofilm peptides to treat chronic wounds.


Assuntos
Anti-Infecciosos , Staphylococcus aureus Resistente à Meticilina , Humanos , Animais , Camundongos , Peptídeos Catiônicos Antimicrobianos/farmacologia , Anti-Infecciosos/farmacologia , Peptídeo Hidrolases , Biofilmes , Antibacterianos/farmacologia , Testes de Sensibilidade Microbiana
16.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37622592

RESUMO

The first edition of Europace journal in 1999 came right around the time of the landmark publication of the electrophysiologists from Bordeaux, establishing how elimination of ectopic activity from the pulmonary veins (PVs) resulted in a marked reduction of atrial fibrillation (AF). The past 25 years have seen an incredible surge in scientific interest to develop new catheters and energy sources to optimize durability and safety of ablation, as well as study the mechanisms for AF and devise ablation strategies. While ablation in the beginning was performed with classic 4 mm tip catheters that emitted radiofrequency (RF) energy to create tissue lesions, this evolved to using irrigation and contact force (CF) measurement while increasing power. Also, so-called single-shot devices were developed with balloons and arrays to create larger contiguous lesions, and energy sources changed from RF current to cryogenic ablation and more recently pulsed field ablation with electrical current. Although PV ablation has remained the basis for every AF ablation, it was soon recognized that this was not enough to cure all patients, especially those with non-paroxysmal AF. Standardized approaches for additional ablation targets have been used but have not been satisfactory in all patients so far. This led to highly technical mapping systems that are meant to unravel the drivers for the maintenance of AF. In the following sections, the development of energies, strategies, and tools is described with a focus on the contribution of Europace to publish the outcomes of studies that were done during the past 25 years.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Catéteres , Terapia de Eletroporação Irreversível
17.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37072340

RESUMO

AIMS: RECOVER AF evaluated the performance of whole-chamber non-contact charge-density mapping to guide the ablation of non-pulmonary vein (PV) targets in persistent atrial fibrillation (AF) patients following either a first or second failed procedure. METHODS AND RESULTS: RECOVER AF was a prospective, non-randomized trial that enrolled patients scheduled for a first or second ablation retreatment for recurrent AF. The PVs were assessed and re-isolated if necessary. The AF maps were used to guide the ablation of non-PV targets through elimination of pathologic conduction patterns (PCPs). Primary endpoint was freedom from AF on or off antiarrhythmic drugs (AADs) at 12 months. Patients undergoing retreatment with the AcQMap System (n = 103) were 76% AF-free at 12 months [67% after single procedure (SP)] on or off AADs (80% free from AF on AADs). Patients who had only received a pulmonary vein isolation (PVI) prior to study treatment of non-PV targets with the AcQMap System were 91% AF-free at 12 months (83% SP). No major adverse events were reported. CONCLUSION: Non-contact mapping can be used to target and guide the ablation of PCPs beyond the PVs in persistent AF patients returning for a first or second retreatment with 76% freedom from AF at 12 months. The AF freedom was particularly high, 91% (43/47), for patients enrolled having only a prior de novo PVI, and freedom from all atrial arrhythmias for this cohort was 74% (35/47). These early results are encouraging and suggest that guiding individualized targeted ablation of PCPs may therefore be advantageous to target at the earliest opportunity in patients with persistent AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Estudos Prospectivos , Veias Pulmonares/cirurgia , Retratamento , Antiarrítmicos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
18.
J Immunol ; 207(5): 1371-1376, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34380647

RESUMO

Inflammatory cytokine storm is a known cause for acute respiratory distress syndrome. In this study, we have investigated the role of IFN-γ in lethal lung inflammation using a mouse model of postinfluenza methicillin-resistant Staphylococcus aureus (MRSA) pneumonia. To mimic the clinical scenario, animals were treated with antibiotics for effective bacterial control following MRSA superinfection. However, antibiotic therapy alone is not sufficient to improve survival of wild-type animals in this lethal acute respiratory distress syndrome model. In contrast, antibiotics induce effective protection in mice deficient in IFN-γ response. Mechanistically, we show that rather than inhibiting bacterial clearance, IFN-γ promotes proinflammatory cytokine response to cause lethal lung damage. Neutralization of IFN-γ after influenza prevents hyperproduction of TNF-α, and thereby protects against inflammatory lung damage and animal mortality. Taken together, the current study demonstrates that influenza-induced IFN-γ drives a stepwise propagation of inflammatory cytokine response, which ultimately results in fatal lung damage during secondary MRSA pneumonia, despite of antibiotic therapy.


Assuntos
Antibacterianos/uso terapêutico , Inflamação/imunologia , Vírus da Influenza A/fisiologia , Influenza Humana/imunologia , Interferon gama/metabolismo , Pulmão/imunologia , Infecções por Orthomyxoviridae/imunologia , Pneumonia Estafilocócica/imunologia , Infecções Estafilocócicas/imunologia , Staphylococcus aureus/fisiologia , Animais , Células Cultivadas , Humanos , Influenza Humana/complicações , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Infecções por Orthomyxoviridae/complicações , Pneumonia Estafilocócica/complicações , Infecções Estafilocócicas/complicações , Superinfecção , Fator de Necrose Tumoral alfa
19.
Am Heart J ; 254: 133-140, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36030965

RESUMO

BACKGROUND: Atrial low voltage area (LVA) catheter ablation has emerged as a promising strategy for ablation of persistent atrial fibrillation (AF). It is unclear if catheter ablation of atrial LVA increases treatment success rates in patients with persistent AF. OBJECTIVE: The primary aim of this trial is to assess the potential benefit of adjunctive catheter ablation of atrial LVA in addition to pulmonary vein isolation (PVI) in patients with persistent AF, when compared to PVI alone. The secondary aims are to evaluate safety outcomes, the quality of life and the healthcare resource utilization. METHODS/DESIGN: A multicenter, prospective, parallel-group, 2-arm, single-blinded randomized controlled trial is under way (NCT03347227). Patients who are candidates for catheter ablation for persistent AF will be randomly assigned (1:1) to either PVI alone or PVI + atrial LVA ablation. The primary outcome is 18-month documented event rate of atrial arrhythmia (AF, atrial tachycardia or atrial flutter) post catheter ablation. Secondary outcomes include procedure-related complications, freedom from atrial arrhythmia at 12 months, AF burden, need for emergency department visits/hospitalization, need for repeat ablation for atrial arrhythmia, quality of life at 12 and 18 months, ablation time, and procedure duration. DISCUSSION: Characterization of Arrhythmia Mechanism to Ablate Atrial Fibrillation (COAST-AF) is a multicenter randomized trial evaluating ablation strategies for catheter ablation. We hypothesize that catheter ablation of atrial LVA in addition to PVI will result in higher procedural success rates when compared to PVI alone in patients with persistent AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Qualidade de Vida , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
20.
Cardiovasc Diabetol ; 21(1): 160, 2022 08 22.
Artigo em Inglês | MEDLINE | ID: mdl-35996159

RESUMO

It is well known that diabetes is a prominent risk factor for cardiovascular (CV) events. The level of CV risk depends on the type and duration of diabetes, age and additional co-morbidities. Diabetes is an independent risk factor for atrial fibrillation (AF) and is frequently observed in patients with AF, which further increases their risk of stroke associated with this cardiac arrhythmia. Nearly one third of patients with diabetes globally have CV disease (CVD). Additionally, co-morbid AF and coronary artery disease are more frequently observed in patients with diabetes than the general population, further increasing the already high CV risk of these patients. To protect against thromboembolic events in patients with diabetes and AF or established CVD, guidelines recommend optimal CV risk factor control, including oral anticoagulation treatment. However, patients with diabetes exist in a prothrombotic and inflammatory state. Greater clinical benefit may therefore be seen with the use of stronger antithrombotic agents or innovative drug combinations in high-risk patients with diabetes, such as those who have concomitant AF or established CVD. In this review, we discuss CV risk management strategies in patients with diabetes and concomitant vascular disease, stroke prevention regimens in patients with diabetes and AF and how worsening renal function in these patients may complicate these approaches. Accumulating evidence from clinical trials and real-world evidence show a benefit to the administration of non-vitamin K antagonist oral anticoagulants for stroke prevention in patients with diabetes and AF.


Assuntos
Fibrilação Atrial , Diabetes Mellitus , Acidente Vascular Cerebral , Trombose , Administração Oral , Anticoagulantes/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/tratamento farmacológico , Diabetes Mellitus/epidemiologia , Fibrinolíticos/efeitos adversos , Humanos , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/prevenção & controle , Trombose/tratamento farmacológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA