1.
Catheter Cardiovasc Interv ; 71(5): 607-12, 2008 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-18360851

RESUMO

OBJECTIVES: The goal of the present study was to test the impact of ST segment resolution (STR) after rescue percutaneous coronary intervention (PCI) on the short-term prognosis. BACKGROUND: The prognostic value of STR after rescue PCI for acute ST elevation myocardial infarction (STEMI) remains undetermined. METHODS: From the French regional database, we analyzed 168 consecutive patients with STEMI and failed lysis, defined by <50 percent STR, who underwent rescue PCI. Patients were classified into two groups according to the degree of STR from the maximal ST-elevation measured on the single worst ECG lead before lysis and after rescue PCI: the without STR group (<50% STR) vs. the with STR group (> or =50%). RESULTS: After rescue PCI, 26 (15%) patients did not have STR and 142 (85%) patients did. No difference was observed between the two groups regarding baseline characteristics, risk factors, and median time delay either from symptom onset to thrombolysis or from failed lysis to rescue PCI. We observed a lower proportion of patients with TIMI 2/3 flow post PCI in the without STR group (respectively 61% vs. 97%, P < 0.001) but an increased use of intra-aortic balloon counterpulsation (34% vs. 8%, P < 0.001) in this group. Thirty-day mortality was markedly higher in the without STR group than in the with STR group (27% vs. 9% respectively, P = 0.025). Moreover, multivariate analysis showed that absence of STR (OR: 5.65; 95% CI: 1.24-25.67), was an independent prognostic factor for mortality. CONCLUSIONS: We showed for the first time that analysis of ST-segment resolution may be a simple reliable tool to identify patients at high risk after rescue PCI, and may provide useful information for the elaboration of therapeutic strategies.


Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Doenças Cardiovasculares/etiologia , Circulação Coronária , Infarto do Miocárdio/terapia , Terapia Trombolítica , Idoso , Angioplastia Coronária com Balão/instrumentação , Doenças Cardiovasculares/mortalidade , Eletrocardiografia , Feminino , França , Pesquisas sobre Atenção à Saúde , Humanos , Balão Intra-Aórtico , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/fisiopatologia , Razão de Chances , Prognóstico , Estudos Prospectivos , Sistema de Registros , Medição de Risco , Stents , Fatores de Tempo , Falha de Tratamento , Resultado do Tratamento
2.
Am Heart J ; 154(2): 330-5, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17643584

RESUMO

BACKGROUND: We aimed to investigate the determinants and outcomes of multiple complex lesions (MCLs) on coronary angiography in patients with an acute myocardial infarction. METHODS: One thousand one hundred fifty-two consecutive nonselected myocardial infarction patients who underwent coronary angiography within 24 hours after admission were analyzed. A complex lesion was defined by the presence of thrombus, ulceration, irregular plaque, and flow impairment. Patients with < or = 1 complex lesion were considered with single complex lesion (SCL), and patients with > 1 complex lesions with MCLs. RESULTS: Multiple complex lesions were identified in 360 patients (31%). Patients from the MCL group were older and had a higher rate of cardiovascular risk factors but were less likely to be smokers when compared with the SCL group. Patients with MCLs were more likely to have altered left ventricular ejection fraction and multivessel disease and showed a trend toward an increased median time delay to revascularization (360 vs 285 minutes; P = .070). Moreover, the C-reactive protein (CRP) plasma levels increased with the number of CLs. By multivariate analysis, multivessel disease and CRP level were associated with the presence of MCLs. When compared with the SCL group, patients with MCLs had a higher risk of inhospital cardiogenic shock (18% vs 11%; P = .005) and 30-day mortality (11% vs 6%; P = .002). At 1-year follow-up, the presence of MCLs was an independent predictive factor of death. CONCLUSIONS: This study shows that the presence of MCLs is associated with worse outcomes and that risk factors such as CRP are able to identify patients at a high risk for MCLs.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Infarto do Miocárdio/diagnóstico por imagem , Idoso , Angiografia Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Fatores de Risco
3.
Am J Cardiol ; 98(2): 167-71, 2006 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-16828586

RESUMO

Hyperglycemia has been shown to be a powerful predictor of worse outcome after ST-segment-elevation myocardial infarction (STEMI), which could be related to impaired myocardial reperfusion. This study investigated the association between hyperglycemia and ST-segment resolution (STR) after thrombolysis. From the French regional Observatoire des Infarctus de Côte-d'Or survey, admission glucose in 371 patients with STEMIs who were treated by lysis<12 hours was analyzed. The single worst lead electrocardiogram before and 90 minutes after lysis was analyzed, and patients were divided into 3 groups according to the degree of STR: none (<30%), partial (30% to 70%), or complete (>or=70%). Of the 371 patients, 101 (27.2%) had no STR, 124 (33.4%) had partial STR, and 146 (39.4%) had complete STR. STR decreased with increasing glycemia (p=0.029), and patients with hyperglycemia (glycemia>or=11 mmol/L) were more likely to have no STR. Moreover, hyperglycemia was an independent predictor of incomplete STR even after adjustment for potential confounders (odds ratio 2.348, 95% confidence interval 1.212 to 4.547). In conclusion, the present study suggests a strong association between hyperglycemia and electrocardiographic signs of reperfusion in patients with STEMIs after lysis and suggests the usefulness of evaluating early glycemic control in the setting of reperfusion for acute myocardial infarction.


Assuntos
Eletrocardiografia , Hiperglicemia/etiologia , Infarto do Miocárdio/terapia , Reperfusão Miocárdica/efeitos adversos , Idoso , Glicemia/metabolismo , Angiografia Coronária , Progressão da Doença , Feminino , Seguimentos , Humanos , Hiperglicemia/sangue , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Prognóstico , Estudos Retrospectivos
4.
Catheter Cardiovasc Interv ; 67(2): 254-7, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16331662

RESUMO

Thrombus removal by aspiration is one of the adjunctive techniques used to avoid embolization during PCI for acute myocardial infarction. Numerous devices are now available, but little is known about the mechanical rationale used in comparing them. The aim of the present study was to determine parameters to obtain optimal thrombus aspiration (TA). Heparin- and antiplatelet-free blood samples were aspirated into 3 mm diameter standardized glass tubes to create a 30 mm long thrombus. Thrombus formation took place at room temperature over a period of 6 or 12 hr. Various catheters were tested using a variable vacuum device: three with right-angle distal tip (0.038'', 0.067'', and 0.070'') and one with a beveled distal (length of the beveled, 0.054''; inner diameter catheter, 0.040''). The single endpoint was complete thrombus aspiration. A total of 103 TAs were presented for the four catheters. For 6- or 12-hr-old thrombus for a given catheter, there was no significant difference in vacuum pressure required to succeed TA (P = 0.47). For 6- or 12-hr-old thrombus, the larger the contact area is, the lower the pressure needed to aspirate the thrombus. Moreover, a beveled distal tip length (0.054'') does not make it possible to succeed TA at a lower pressure. The main factor for successful TA for thrombi > or = 6 hr is inner diameter and not immediate thrombus contact area.


Assuntos
Trombose Coronária/terapia , Trombectomia/instrumentação , Distribuição de Qui-Quadrado , Desenho de Equipamento , Humanos , Técnicas In Vitro , Sucção/instrumentação , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA