Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Radiol ; 33(2): 1229-1242, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36029346

RESUMO

OBJECTIVES: Cardiac implantable electronic device (CIED)-induced metal artefacts possibly significantly diminish the diagnostic value of magnetic resonance imaging (MRI), particularly cardiac MR (CMR). Right-sided generator implantation, wideband late-gadolinium enhancement (LGE) technique and raising the ipsilateral arm to the generator during CMR scanning may reduce the CIED-induced image artefacts. We assessed the impact of generator location and the arm-raised imaging position on the CIED-induced artefacts in CMR. METHODS: We included all clinically indicated CMRs performed on patients with normal cardiac anatomy and a permanent CIED with endocardial pacing leads between November 2011 and October 2019 in our institution (n = 171). We analysed cine and LGE sequences using the American Heart Association 17-segment model for the presence of artefacts. RESULTS: Right-sided generator implantation and arm-raised imaging associated with a significantly increased number of artefact-free segments. In patients with a right-sided pacemaker, the median percentage of artefact-free segments in short-axis balanced steady-state free precession LGE was 93.8% (IQR 9.4%, n = 53) compared with 78.1% (IQR 20.3%, n = 58) for left-sided pacemaker (p < 0.001). In patients with a left-sided implantable cardioverter-defibrillator, the median percentage of artefact-free segments reached 87.5% (IQR 6.3%, n = 9) using arm-raised imaging, which fell to 62.5% (IQR 34.4%, n = 9) using arm-down imaging in spoiled gradient echo short-axis cine (p = 0.02). CONCLUSIONS: Arm-raised imaging represents a straightforward method to reduce CMR artefacts in patients with left-sided generators and can be used alongside other image quality improvement methods. Right-sided generator implantation could be considered in CIED patients requiring subsequent CMR imaging to ensure sufficient image quality. KEY POINTS: • Cardiac implantable electronic device (CIED)-induced metal artefacts may significantly diminish the diagnostic value of an MRI, particularly in cardiac MRIs. • Raising the ipsilateral arm relative to the CIED generator is a cost-free, straightforward method to significantly reduce CIED-induced artefacts on cardiac MRIs in patients with a left-sided generator. • Right-sided generator implantation reduces artefacts compared with left-sided implantation and could be considered in CIED patients requiring subsequent cardiac MRIs to ensure adequate image quality in the future.


Assuntos
Desfibriladores Implantáveis , Imagem Cinética por Ressonância Magnética , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Meios de Contraste , Gadolínio , Imageamento por Ressonância Magnética/métodos
2.
Eur Radiol ; 32(6): 3830-3838, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34989847

RESUMO

OBJECTIVES: The European Society of Cardiology Guidelines on cardiac pacing from 2021 allow magnetic resonance imaging (MRI) in patients with cardiac implantable electronic devices (CIEDs) but do not recommend MRI in patients with epicardial pacing leads. The clinical dilemma remains whether performing an MRI in patients with CIED and epicardial leads is safe. We aimed to evaluate the safety of performing an MRI in patients with CIED and abandoned or functioning epicardial pacing leads. METHODS: We included all adult patients who underwent clinically indicated MRIs with CIED and functioning or abandoned epicardial leads in a single tertiary hospital between November 2011 and October 2019. The data were retrospectively collected. RESULTS: Twenty-six MRIs were performed on 17 patients with functioning or abandoned epicardial pacing leads. Sixty-nine percent of the MRI scans (18/26) were conducted on patients with functioning epicardial pacing leads. A definite adverse event occurred in one MRI scan. This was a transient elevation of the pacing threshold in a patient with a functioning epicardial ventricular pacing lead implanted 29 years previously. An irreversible atrial pacing lead impedance elevation was detected 6 months after the MRI in another patient; the association with the previous MRI remained unclear. No adverse events were detected in MRIs performed on patients with modern (implanted in 2000 or later) functioning epicardial leads. CONCLUSIONS: MRIs in patients with CIED and modern functioning epicardial pacing leads were performed without detectable adverse events. Further large-scale studies are necessary to confirm MRI safety in patients with epicardial pacing leads. KEY POINTS: • Currently, MRI in patients with cardiac implantable electronic devices (CIEDs) and functioning or abandoned epicardial pacing leads is not recommended. • MRIs in patients with CIED and modern functioning epicardial leads (implanted in 2000 or later) were performed without detectable adverse events in our patient cohort. • Allowing MRI in patients with epicardial pacing leads may significantly improve the diagnostic work-up, especially in specific patient groups, such as patients with congenital heart disease.


Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Marca-Passo Artificial , Adulto , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos
3.
Acta Radiol ; 60(11): 1414-1421, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-30781967

RESUMO

Background: Magnetic resonance imaging (MRI) in patients with cardiac pacing devices has become available despite previously being considered absolutely contraindicated. However, most institutional safety protocols have included several limitations on patient selection, leaving MRI unavailable for many patients. Purpose: To evaluate the first 1000 MRI examinations conducted on patients with cardiac pacing devices at Helsinki University Hospital for any potential safety hazards and also to evaluate the long-term functionality of the safety protocol in "real-life" clinical practice. Material and Methods: A total of 1000 clinically indicated MRI scans were performed with a 1.5-T MRI scanner according to the safety protocol. The following information was collected from the electronic medical record (EMR): patients' date of birth; sex; pacing device generator model; date of MRI scan; date of the latest pacing device generator implantation; and the body region scanned. The EMR of these patients was checked and especially searched for any pacing device related safety hazards or adverse outcomes during or after the MRI scan. Results: Only one potentially dangerous adverse event was noted in our study group. In addition, patients with abandoned leads, temporary pacing devices, and newly implanted pacing device generators were scanned successfully and safely. Conclusion: MRI scans can be performed safely in patients with cardiac pacing devices if the dedicated safety protocol is followed.


Assuntos
Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Marca-Passo Artificial , Segurança do Paciente/estatística & dados numéricos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
4.
PLoS One ; 18(3): e0282394, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36888600

RESUMO

BACKGROUND: Long-term symptoms are frequent after coronavirus disease 2019 (COVID-19). We studied the prevalence of post-acute myocardial scar on cardiac magnetic resonance imaging (CMR) in patients hospitalized due to COVID-19 and its association with long-term symptoms. MATERIALS AND METHODS: In this prospective observational single-center study, 95 formerly hospitalized COVID-19 patients underwent CMR imaging at the median of 9 months after acute COVID-19. In addition, 43 control subjects were imaged. Myocardial scar characteristic of myocardial infarction or myocarditis were noted from late gadolinium enhancement images (LGE). Patient symptoms were screened using a questionnaire. Data are presented as mean ± standard deviation or median (interquartile range). RESULTS: The presence of any LGE was higher in COVID-19 patients (66% vs. 37%, p<0.01) as was the presence of LGE suggestive of previous myocarditis (29% vs. 9%, p = 0.01). The prevalence of ischemic scar was comparable (8% vs. 2%, p = 0.13). Only two COVID-19 patients (7%) had myocarditis scar combined with left ventricular dysfunction (EF <50%). Myocardial edema was not detected in any participant. The need for intensive care unit (ICU) treatment during initial hospitalization was comparable in patients with and without myocarditis scar (47% vs. 67%, p = 0.44). Dyspnea, chest pain, and arrhythmias were prevalent in COVID-19 patients at follow-up (64%, 31%, and 41%, respectively) but not associated with myocarditis scar on CMR. CONCLUSIONS: Myocardial scar suggestive of possible previous myocarditis was detected in almost one-third of hospital-treated COVID-19 patients. It was not associated with the need for ICU treatment, greater symptomatic burden, or ventricular dysfunction at 9 months follow-up. Thus, post-acute myocarditis scar on COVID-19 patients seems to be a subclinical imaging finding and does not commonly require further clinical evaluation.


Assuntos
COVID-19 , Traumatismos Cardíacos , Miocardite , Humanos , Miocardite/complicações , Meios de Contraste , Cicatriz/complicações , Função Ventricular Esquerda , COVID-19/complicações , Gadolínio , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Traumatismos Cardíacos/complicações , Imagem Cinética por Ressonância Magnética/métodos , Valor Preditivo dos Testes
5.
J Imaging ; 9(3)2023 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-36976106

RESUMO

Cine-MRI for adhesion detection is a promising novel modality that can help the large group of patients developing pain after abdominal surgery. Few studies into its diagnostic accuracy are available, and none address observer variability. This retrospective study explores the inter- and intra-observer variability, diagnostic accuracy, and the effect of experience. A total of 15 observers with a variety of experience reviewed 61 sagittal cine-MRI slices, placing box annotations with a confidence score at locations suspect for adhesions. Five observers reviewed the slices again one year later. Inter- and intra-observer variability are quantified using Fleiss' (inter) and Cohen's (intra) κ and percentage agreement. Diagnostic accuracy is quantified with receiver operating characteristic (ROC) analysis based on a consensus standard. Inter-observer Fleiss' κ values range from 0.04 to 0.34, showing poor to fair agreement. High general and cine-MRI experience led to significantly (p < 0.001) better agreement among observers. The intra-observer results show Cohen's κ values between 0.37 and 0.53 for all observers, except one with a low κ of -0.11. Group AUC scores lie between 0.66 and 0.72, with individual observers reaching 0.78. This study confirms that cine-MRI can diagnose adhesions, with respect to a radiologist consensus panel and shows that experience improves reading cine-MRI. Observers without specific experience adapt to this modality quickly after a short online tutorial. Observer agreement is fair at best and area under the receiver operating characteristic curve (AUC) scores leave room for improvement. Consistently interpreting this novel modality needs further research, for instance, by developing reporting guidelines or artificial intelligence-based methods.

6.
J Am Heart Assoc ; 11(11): e024257, 2022 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-35658507

RESUMO

Background Some myocardial diseases, such as cardiac sarcoidosis, predispose to complete atrioventricular block. The European Society of Cardiology Guidelines on cardiac pacing in 2021 recommend myocardial disease screening in patients with conduction disorder requiring pacemaker with multimodality imaging, including cardiac magnetic resonance (CMR) imaging. The ability of CMR imaging to detect myocardial disease in patients with a temporary pacing wire is not well documented. Methods and Results Our myocardial disease screening protocol is based on using an active fixation pacing lead connected to a reusable extracorporeal pacing generator (temporary permanent pacemaker) as a bridge to a permanent pacemaker. From 2011 to 2019, we identified 17 patients from our CMR database who underwent CMR imaging with a temporary permanent pacemaker for atrioventricular block. We analyzed their clinical presentations, CMR data, and pacemaker therapy. All CMRs were performed without adverse events. Pacing leads induced minor artifacts to the septal myocardial segments. The extent of late gadolinium enhancement in CMR imaging was used to screen patients for the presence of myocardial disease. Patients with evidence of late gadolinium enhancement underwent endomyocardial biopsy. If considered clinically indicated, also 18-F-fluorodeoxyglucose positron emission tomography and extracardiac tissue biopsy were performed if sarcoidosis was suspected. Eventually, 8 of 17 patients (47.1%) were diagnosed with histologically confirmed granulomatous inflammatory cardiac disease. Importantly, only 1 had a previously diagnosed extracardiac sarcoidosis at the time of presentation with high-degree atrioventricular block. Conclusions CMR imaging with temporary permanent pacemaker protocol is an effective and safe early screening tool for myocardial disease in patients presenting with atrioventricular block requiring immediate, continuous pacing for bradycardia.


Assuntos
Bloqueio Atrioventricular , Cardiomiopatias , Miocardite , Sarcoidose , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , Cardiomiopatias/diagnóstico , Cardiomiopatias/diagnóstico por imagem , Meios de Contraste , Gadolínio , Humanos , Imageamento por Ressonância Magnética , Sarcoidose/diagnóstico , Sarcoidose/diagnóstico por imagem
7.
Acad Radiol ; 25(4): 476-485, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29199058

RESUMO

RATIONALE AND OBJECTIVES: To evaluate the effects of 1 year of medical treatment on myocardial function in active rheumatoid arthritis (RA). MATERIALS AND METHODS: Thirty-nine female patients with RA without any known cardiovascular disease underwent a cardiovascular magnetic resonance (CMR) examination before and after 1 year of antirheumatic treatment. The population comprised untreated active early RA (ERA) and chronic RA patients, who were grouped accordingly. The CMR protocol included volumetric determinations, late gadolinium enhancement imaging, myocardial tagging, and native T1 mapping. DAS28-CRP disease activity scores were calculated before and after the treatment. RESULTS: Results are reported as median (quartile 1-quartile 3). Time to peak diastolic filling rate improved in ERA (495 [443-561] ms vs 441 [340-518] ms, P = .018). Peak diastolic mean mid short-axis circumferential strain rate of all six segments was improved (82 [74-91] %/s vs 91 [77-100] %/s, P = .05), particularly in the anterior segment (82 [63-98] %/s vs 86 [77-109] %/s, P = .013). DAS28-CRP decreased in ERA (3.8 [3.2-4.1] vs 1.6 [1.4-2.2], P < .001). In chronic RA, no statistically significant improvement was detected. CONCLUSIONS: Early treatment of active RA is important, as myocardial function detected with CMR tagging improved in ERA in parallel with decreasing inflammatory activity.


Assuntos
Artrite Reumatoide/tratamento farmacológico , Artrite Reumatoide/fisiopatologia , Coração/diagnóstico por imagem , Coração/fisiopatologia , Imageamento por Ressonância Magnética , Adulto , Idoso , Antirreumáticos/uso terapêutico , Diástole , Feminino , Seguimentos , Gadolínio , Humanos , Aumento da Imagem , Pessoa de Meia-Idade , Miocárdio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA