Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38889365

RESUMO

BACKGROUND: Many children undergo allogeneic Hematopoietic Stem Cell Transplantation (HSCT) for the treatment of malignant and non-malignant conditions. Unfortunately, pulmonary complications occur frequently post-HSCT, with bronchiolitis obliterans syndrome (BOS) being the most common non-infectious pulmonary complication. Current international guidelines contain conflicting recommendations regarding post-HSCT surveillance for BOS, and a recent National Institutes of Health workshop highlighted the need for a standardized approach to post-HSCT monitoring. As such, this guideline provides an evidence-based approach to detection of post-HSCT BOS in children. METHODS: A multinational, multidisciplinary panel of experts identified six questions regarding surveillance for, and evaluation of post-HSCT BOS in children. Systematic review of the literature was undertaken to answer each question. The Grading of Recommendations, Assessment, Development, and Evaluation approach was used to rate the quality of evidence and the strength of recommendations. RESULTS: The panel members considered the strength of each recommendation and evaluated the benefits and risks of applying the intervention. In formulating the recommendations, the panel considered patient and caregiver values, the cost of care, and feasibility. Recommendations addressing the role of screening pulmonary function testing and diagnostic tests in children with suspected post-HSCT BOS were made. Following a Delphi process, new diagnostic criteria for pediatric post-HSCT BOS were also proposed. CONCLUSIONS: This document provides an evidence-based approach to detection of post-HSCT BOS in children, while also highlighting considerations for implementation of each recommendation. Further, the document describes important areas for future research.

2.
Magn Reson Med ; 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38860514

RESUMO

PURPOSE: Hyperpolarized 129Xe MRI benefits from non-Cartesian acquisitions that sample k-space efficiently and rapidly. However, their reconstructions are complex and burdened by decay processes unique to hyperpolarized gas. Currently used gridded reconstructions are prone to artifacts caused by magnetization decay and are ill-suited for undersampling. We present a compressed sensing (CS) reconstruction approach that incorporates magnetization decay in the forward model, thereby producing images with increased sharpness and contrast, even in undersampled data. METHODS: Radio-frequency, T1, and T 2 * $$ {\mathrm{T}}_2^{\ast } $$ decay processes were incorporated into the forward model and solved using iterative methods including CS. The decay-modeled reconstruction was validated in simulations and then tested in 2D/3D-spiral ventilation and 3D-radial gas-exchange MRI. Quantitative metrics including apparent-SNR and sharpness were compared between gridded, CS, and twofold undersampled CS reconstructions. Observations were validated in gas-exchange data collected from 15 healthy and 25 post-hematopoietic-stem-cell-transplant participants. RESULTS: CS reconstructions in simulations yielded images with threefold increases in accuracy. CS increased sharpness and contrast for ventilation in vivo imaging and showed greater accuracy for undersampled acquisitions. CS improved gas-exchange imaging, particularly in the dissolved-phase where apparent-SNR improved, and structure was made discernable. Finally, CS showed repeatability in important global gas-exchange metrics including median dissolved-gas signal ratio and median angle between real/imaginary components. CONCLUSION: A non-Cartesian CS reconstruction approach that incorporates hyperpolarized 129Xe decay processes is presented. This approach enables improved image sharpness, contrast, and overall image quality in addition to up-to threefold undersampling. This contribution benefits all hyperpolarized gas MRI through improved accuracy and decreased scan durations.

3.
Magn Reson Med ; 89(3): 1117-1133, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36372970

RESUMO

PURPOSE: Xenon-129 (129 Xe) gas-exchange MRI is a pulmonary-imaging technique that provides quantitative metrics for lung structure and function and is often compared to pulmonary-function tests. Unlike such tests, it does not normalize to predictive values based on demographic variables such as age. Many sites have alluded to an age dependence in gas-exchange metrics; however, a procedure for normalizing metrics has not yet been introduced. THEORY: We model healthy reference values for 129 Xe gas-exchange MRI against age using generalized additive models for location, scale, and shape (GAMLSS). GAMLSS takes signal data from an aggregated heathy-reference cohort and fits a distribution with flexible median, variation, skewness, and kurtosis to predict age-dependent centiles. This approach mirrors methods by the Global Lung Function Initiative for modeling pulmonary-function test data and applies it to binning methods widely used by the 129 Xe MRI community to interpret and quantify gas-exchange data. METHODS: Ventilation, membrane-uptake, red blood cell transfer, and red blood cell:membrane gas-exchange metrics were collected on 30 healthy subjects over an age range of 5 to 68 years. A GAMLSS model was fit against age and compared against widely used linear and generalized-linear binning 129 Xe MRI analysis schemes. RESULTS: All 4 gas-exchange metrics had significant skewness, and membrane-uptake had significant kurtosis compared to a normal distribution. Age has significant impact on distribution parameters. GAMLSS-binning produced narrower bins compared to the linear and generalized-linear binning schemes and distributed signal data closer to a normal distribution. CONCLUSION: The proposed "proof-of-concept" GAMLSS-binning approach can improve diagnostic accuracy of 129 Xe gas-exchange MRI by providing a means of modeling voxel distribution data against age.


Assuntos
Pulmão , Imageamento por Ressonância Magnética , Criança , Humanos , Adolescente , Adulto Jovem , Pré-Escolar , Adulto , Pessoa de Meia-Idade , Idoso , Imageamento por Ressonância Magnética/métodos , Pulmão/diagnóstico por imagem , Isótopos de Xenônio , Testes de Função Respiratória , Respiração , Eritrócitos
4.
Magn Reson Med ; 90(2): 473-482, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36989185

RESUMO

PURPOSE: To mitigate signal variations caused by inhomogeneous RF and magnetization decay in hyperpolarized 129 Xe ventilation images using flip-angle maps generated from sequential 2D spiral ventilation images acquired in a breath-hold. Images and correction maps were compared with those obtained using conventional, 2D gradient-recalled echo. THEORY AND METHODS: Analytical expressions to predict signal intensity and uncertainty in flip-angle measurements were derived from the Bloch equations and validated by simulations and phantom experiments. Imaging in 129 Xe phantoms and human subjects (1 healthy, 1 cystic fibrosis) was performed using 2D gradient-recalled echo and spiral. For both sequences, consecutive images were acquired with the same slice position during a breath-hold (Cartesian scan time = 15 s; spiral scan time = 5 s). The ratio of these images was used to calculate flip-angle maps and correct intensity inhomogeneities in ventilation images. RESULTS: Mean measured flip angle showed excellent agreement with the applied flip angle in simulations (R2 = 0.99) for both sequences. Mean measured flip angle agreed well with the globally applied flip angle (∼15% difference) in 129 Xe phantoms and in vivo imaging using both sequences. Corrected images displayed reduced coil-dependent signal nonuniformity relative to uncorrected images. CONCLUSIONS: Flip-angle maps were obtained using sequentially acquired, 2D spiral, 129 Xe ventilation images. Signal intensity variations caused by RF-coil inhomogeneity can be corrected by acquiring sequential single-breath ventilation images in less than 5-s scan time. Thus, this method can be used to remove undesirable heterogeneity while preserving physiological effects on the signal distribution.


Assuntos
Pulmão , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Pulmão/diagnóstico por imagem , Pulmão/fisiologia , Respiração , Imagens de Fantasmas , Suspensão da Respiração , Isótopos de Xenônio
5.
NMR Biomed ; 35(3): e4639, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34729838

RESUMO

RATIONALE: Hyperpolarized (HP) 129 Xe-MRI provides non-invasive methods to quantify lung function and structure, with the 129 Xe apparent diffusion coefficient (ADC) being a well validated measure of alveolar airspace size. However, the experimental factors that impact the precision and accuracy of HP 129 Xe ADC measurements have not been rigorously investigated. Here, we introduce an analytical model to predict the experimental uncertainty of 129 Xe ADC estimates. Additionally, we report ADC dependence on age in healthy pediatric volunteers. METHODS: An analytical expression for ADC uncertainty was derived from the Stejskal-Tanner equation and simplified Bloch equations appropriate for HP media. Parameters in the model were maximum b-value (bmax ), number of b-values (Nb ), number of phase encoding lines (Nph ), flip angle and the ADC itself. This model was validated by simulations and phantom experiments, and five fitting methods for calculating ADC were investigated. To examine the lower range for 129 Xe ADC, 32 healthy subjects (age 6-40 years) underwent diffusion-weighted 129 Xe MRI. RESULTS: The analytical model provides a lower bound on ADC uncertainty and predicts that decreased signal-to-noise ratio yields increases in relative uncertainty (ϵADC) . As such, experimental parameters that impact non-equilibrium 129 Xe magnetization necessarily impact the resulting ϵADC . The values of diffusion encoding parameters (Nb and bmax ) that minimize ϵADC strongly depend on the underlying ADC value, resulting in a global minimum for ϵADC . Bayesian fitting outperformed other methods (error < 5%) for estimating ADC. The whole-lung mean 129 Xe ADC of healthy subjects increased with age at a rate of 1.75 × 10-4  cm2 /s/yr (p = 0.001). CONCLUSIONS: HP 129 Xe diffusion MRI can be improved by minimizing the uncertainty of ADC measurements via uncertainty propagation. Doing so will improve experimental accuracy when measuring lung microstructure in vivo and should allow improved monitoring of regional disease progression and assessment of therapy response in a range of lung diseases.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Pulmão/diagnóstico por imagem , Isótopos de Xenônio , Adolescente , Adulto , Fatores Etários , Criança , Difusão , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Razão Sinal-Ruído , Incerteza , Adulto Jovem
6.
J Magn Reson Imaging ; 56(4): 1207-1219, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35244302

RESUMO

BACKGROUND: 129 Xe gas-transfer MRI provides regional measures of pulmonary gas exchange in adults and separates xenon in interstitial lung tissue/plasma (barrier) from xenon in red blood cells (RBCs). The technique has yet to be demonstrated in pediatric populations or conditions. PURPOSE/HYPOTHESIS: To perform an exploratory analysis of 129 Xe gas-transfer MRI in children. STUDY TYPE: Prospective. POPULATION: Seventy-seven human volunteers (38 males, age = 17.7 ± 15.1 years, range 5-68 years, 16 healthy). Four pediatric disease cohorts. FIELD STRENGTH/SEQUENCE: 3-T, three-dimensional-radial one-point Dixon Fast Field Echo (FFE) Ultrashort Echo Time (UTE). ASSESSMENT: Breath hold compliance was assessed by quantitative signal-to-noise and dynamic metrics. Whole-lung means and standard deviations were extracted from gas-transfer maps. Gas-transfer metrics were investigated with respect to age and lung disease. Clinical pulmonary function tests were retrospectively acquired for reference lung disease severity. STATISTICAL TESTS: Wilcoxon rank-sum tests to compare age and disease cohorts, Wilcoxon signed-rank tests to compare pre- and post-breath hold vitals, Pearson correlations between age and gas-transfer metrics, and limits of normal with a binomial exact test to compare fraction of subjects with abnormal gas-transfer. P ≤ 0.05 was considered significant. RESULTS: Eighty percentage of pediatric subjects successfully completed 129 Xe gas-transfer MRI. Gas-transfer parameters differed between healthy children and adults, including ventilation (0.75 and 0.67) and RBC:barrier ratio (0.31 and 0.46) which also correlated with age (ρ = -0.76, 0.57, respectively). Bone marrow transplant subjects had impaired ventilation (90% of reference) and increased dissolved 129 Xe standard deviation (242%). Bronchopulmonary dysplasia subjects had decreased barrier-uptake (69%). Cystic fibrosis subjects had impaired ventilation (91%) and increased RBC-transfer (146%). Lastly, childhood interstitial lung disease subjects had increased ventilation heterogeneity (113%). Limits of normal provided detection of abnormalities in additional gas-transfer parameters. DATA CONCLUSION: Pediatric 129 Xe gas-transfer MRI was adequately successful and gas-transfer metrics correlated with age. Exploratory analysis revealed abnormalities in a variety of pediatric obstructive and restrictive lung diseases. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Pneumopatias , Isótopos de Xenônio , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Estudos de Viabilidade , Humanos , Imageamento Tridimensional/métodos , Recém-Nascido , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Xenônio , Adulto Jovem
7.
J Allergy Clin Immunol ; 147(6): 2146-2153.e1, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33227317

RESUMO

BACKGROUND: Measurement of regional lung ventilation with hyperpolarized 129Xe magnetic resonance imaging (129Xe MRI) in pediatric asthma is poised to advance our understanding of disease mechanisms and pathophysiology in a disorder with diverse clinical phenotypes. 129Xe MRI has not been investigated in a pediatric asthma cohort. OBJECTIVE: We hypothesized that 129Xe MRI is feasible and can demonstrate ventilation defects that relate to and predict clinical severity in a pediatric asthma cohort. METHODS: Thirty-seven children (13 with severe asthma, 8 with mild/moderate asthma, 16 age-matched healthy controls) aged 6 to 17 years old were imaged with 129Xe MRI. Ventilation defect percentage (VDP) and image reader score were calculated and compared with clinical measures at baseline and at follow-up. RESULTS: Children with asthma had higher VDP (P = .002) and number of defects per image slice (defects/slice) (P = .0001) than children without asthma. Children with clinically severe asthma had significantly higher VDP and number of defects/slice than healthy controls. Children with asthma who had a higher number of defects/slice had a higher rate of health care utilization (r = 0.48; P = .03) and oral corticosteroid use (r = 0.43; P = .05) at baseline. Receiver-operating characteristic analysis demonstrated that the VDP and number of defects/slice were predictive of increased health care utilization, asthma, and severe asthma. VDP correlated with FEV1 (r = -0.35; P = .04) and FEV1/forced vital capacity ratio (r = -0.41; P = .01). CONCLUSIONS: 129Xe MRI correlates with asthma severity, health care utilization, and oral corticosteroid use. Because delineation of clinical severity is often difficult in children, 129Xe MRI may be an important biomarker for severity, with potential to identify children at higher risk for exacerbations and improve outcomes.


Assuntos
Asma/diagnóstico , Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Isótopos de Xenônio , Adolescente , Asma/terapia , Estudos de Casos e Controles , Criança , Feminino , Humanos , Masculino , Curva ROC , Testes de Função Respiratória , Índice de Gravidade de Doença
8.
Magn Reson Med ; 86(2): 907-915, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33665905

RESUMO

PURPOSE: Hyperpolarized xenon (129 Xe) gas-transfer imaging allows different components of pulmonary gas transfer-alveolar air space, lung interstitium/blood plasma (barrier), and red blood cells (RBCs)-to be assessed separately in a single breath. However, quantitative analysis is challenging because dissolved-phase 129 Xe images are often contaminated by off-resonant gas-phase signal generated via imperfectly selective excitation. Although previous methods required additional data for gas-phase removal, the method reported here requires no/minimal sequence modifications/data acquisitions, allowing many previously acquired images to be corrected retroactively. METHODS: 129 Xe imaging was implemented at 3.0T via an interleaved three-dimensional radial acquisition of the gaseous and dissolved phases (using one-point Dixon reconstruction for the dissolved phase) in 46 human subjects and a phantom. Gas-phase contamination (9.5% ± 4.8%) was removed from gas-transfer data using a modified gas-phase image. The signal-to-noise ratio (SNR) and signal distributions were compared before and after contamination removal. Additionally, theoretical gaseous contaminations were simulated at different magnetic field strengths for comparison. RESULTS: Gas-phase contamination at 3.0T was more diffuse and located predominantly outside the lungs, relative to simulated 1.5T contamination caused by the larger frequency offset. Phantom experiments illustrated a 91% removal efficiency. In human subjects, contamination removal produced significant changes in dissolved signal SNR (+7.8%), mean (-1.4%), and standard deviation (-2.3%) despite low contamination. Repeat measurements showed reduced variance (dissolved mean, -1.0%; standard deviation, -8.4%). CONCLUSION: Off-resonance gas-phase contamination can be removed robustly with no/minimal sequence modifications. Contamination removal permits more accurate quantification, reduces radiofrequency stringency requirements, and increases data consistency, providing improved sensitivity needed for multicenter trials.


Assuntos
Artefatos , Isótopos de Xenônio , Humanos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Xenônio
9.
J Magn Reson Imaging ; 53(6): 1853-1861, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33404085

RESUMO

Infants admitted to the neonatal intensive care unit (NICU) often suffer from multifaceted pulmonary morbidities that are not well understood. Ultrashort echo time (UTE) magnetic resonance imaging (MRI) is a promising technique for pulmonary imaging in this population without requiring exposure to ionizing radiation. The aims of this study were to investigate the effect of neonatal pulmonary disease on R2 * and tissue density and to utilize numerical simulations to evaluate the effect of different alveolar structures on predicted R2 *.This was a prospective study, in which 17 neonatal human subjects (five control, seven with bronchopulmonary dysplasia [BPD], five with congenital diaphragmatic hernia [CDH]) were enrolled. Twelve subjects were male and five were female, with postmenstrual age (PMA) at MRI of 39.7 ± 4.7 weeks. A 1.5T/multiecho three-dimensional UTE MRI was used. Pulmonary R2 * and tissue density were compared across disease groups over the whole lung and regionally. A spherical shell alveolar model was used to predict the expected R2 * over a range of tissue densities and tissue susceptibilities. Tests for significantly different mean R2 * and tissue densities across disease groups were evaluated using analysis of variance, with subsequent pairwise group comparisons performed using t tests. Lung tissue density was lower in the ipsilateral lung in CDH compared to both controls and BPD patients (both p < 0.05), while only the contralateral lung in CDH (CDHc) had higher whole-lung R2 * than both controls and BPD (both p < 0.05). R2 * differences were significant between controls and CDHc within all tissue density ranges (all p < 0.05) with the exception of the 80%-90% range (p = 0.17). Simulations predicted an inverse relationship between alveolar tissue density and R2 * that matches empirical human data. Alveolar wall thickness had no effect on R2 * independent of density (p = 1). The inverse relationship between R2 * and tissue density is influenced by the presence of disease globally and regionally in neonates with BPD and CDH in the NICU. LEVEL OF EVIDENCE: 2. TECHNICAL EFFICACY STAGE: 2.


Assuntos
Displasia Broncopulmonar , Pulmão , Displasia Broncopulmonar/diagnóstico por imagem , Pré-Escolar , Feminino , Humanos , Imageamento Tridimensional , Lactente , Recém-Nascido , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos
10.
Magn Reson Med ; 84(1): 312-320, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31788858

RESUMO

PURPOSE: Hyperpolarized 129 Xe MRI characterizes regional lung ventilation in a variety of disease populations, with high sensitivity to airway obstruction in early disease. However, ventilation images are usually limited to a single breath-hold and most-often acquired using gradient-recalled echo sequences with thick slices (~10-15 mm), which increases partial-volume effects, limits ability to observe small defects, and suffers from imperfect slice selection. We demonstrate higher-resolution ventilation images, in shorter breath-holds, using FLORET (Fermat Looped ORthogonally Encoded Trajectories), a center-out 3D-spiral UTE sequence. METHODS: In vivo human adult (N = 4; 2 healthy, 2 with cystic fibrosis) 129 Xe images were acquired using 2D gradient-recalled echo, 3D radial, and FLORET. Each sequence was acquired at its highest possible resolution within a 16-second breath-hold with a minimum voxel dimension of 3 mm. Images were compared using 129 Xe ventilation defect percentage, SNR, similarity coefficients, and vasculature cross-sections. RESULTS: The FLORET sequence obtained relative normalized SNR, 40% greater than 2D gradient-recalled echo (P = .012) and 26% greater than 3D radial (P = .067). Moreover, the FLORET images were acquired with 3-fold-higher nominal resolution in a 15% shorter breath-hold. Finally, vasculature was less prominent in FLORET, likely due to diminished susceptibility-induced dephasing at shorter TEs afforded by UTE sequences. CONCLUSION: The FLORET sequence yields higher SNR for a given resolution with a shorter breath-hold than traditional ventilation imaging techniques. This sequence more accurately measures ventilation abnormalities and enables reduced scan times in patients with poor compliance and severe lung disease.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Adulto , Suspensão da Respiração , Humanos , Pulmão/diagnóstico por imagem , Ventilação Pulmonar , Respiração
11.
Eur Respir J ; 53(5)2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30846475

RESUMO

BACKGROUND: Early detection of pulmonary morbidity following haematopoietic stem cell transplantation (HSCT) remains an important challenge for intervention, primarily due to the insensitivity of spirometry to early change, and in paediatrics, patient compliance provides additional challenges. Regional lung ventilation abnormalities in paediatric HSCT patients were quantified using hyperpolarised xenon-129 (129Xe) magnetic resonance imaging (MRI) and compared to spirometry. METHODS: Medically stable, paediatric allogeneic HSCT patients (n=23, ages 6-16 years) underwent an outpatient MRI scan where regional ventilation was quantified with a breath-hold of hyperpolarised 129Xe gas. Ventilation deficits, regions of the lung that ventilate poorly due to obstruction, were quantified as a ventilation defect percentage (VDP) and compared to forced expiratory volume in 1 s (FEV1), FEV1/forced vital capacity (FVC) ratio, and forced expiratory flow at 25-75% of FVC (FEF25-75%) from spirometry using linear regression. RESULTS: The mean±sd 129Xe VDP was 10.5±9.4% (range 2.6-41.4%). 129Xe VDP correlated with FEV1, FEV1/FVC ratio and FEF25-75% (p≤0.02 for all comparisons). Ventilation deficits were detected in patients with normal spirometry (i.e. FEV1 >80%), supporting the sensitivity of 129Xe MRI to early obstruction reported in other pulmonary conditions. Seven (30%) patients could not perform spirometry, yet ventilation deficits were observed in five of these patients, detecting abnormalities that otherwise may have gone undetected and untreated until advanced. CONCLUSION: Lung ventilation deficits were detected using hyperpolarised 129Xe gas MRI in asymptomatic paediatric HSCT patients and in a subgroup who were unable to perform reliable spirometry. 129Xe MRI provides a reliable imaging-based assessment of pulmonary involvement in this potentially difficult to diagnose paediatric population.


Assuntos
Transplante de Células-Tronco Hematopoéticas , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Isótopos de Xenônio , Adolescente , Criança , Feminino , Volume Expiratório Forçado , Humanos , Modelos Lineares , Masculino , Ventilação Pulmonar , Testes de Função Respiratória , Espirometria , Capacidade Vital
12.
Am J Respir Crit Care Med ; 198(10): 1302-1311, 2018 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-29790784

RESUMO

RATIONALE: Bronchopulmonary dysplasia (BPD) is a serious neonatal pulmonary condition associated with premature birth, but the underlying parenchymal disease and trajectory are poorly characterized. The current National Institute of Child Health and Human Development (NICHD)/NHLBI definition of BPD severity is based on degree of prematurity and extent of oxygen requirement. However, no clear link exists between initial diagnosis and clinical outcomes. OBJECTIVES: We hypothesized that magnetic resonance imaging (MRI) of structural parenchymal abnormalities will correlate with NICHD-defined BPD disease severity and predict short-term respiratory outcomes. METHODS: A total of 42 neonates (20 severe BPD, 6 moderate, 7 mild, 9 non-BPD control subjects; 40 ± 3-wk postmenstrual age) underwent quiet-breathing structural pulmonary MRI (ultrashort echo time and gradient echo) in a neonatal ICU-sited, neonatal-sized 1.5 T scanner, without sedation or respiratory support unless already clinically prescribed. Disease severity was scored independently by two radiologists. Mean scores were compared with clinical severity and short-term respiratory outcomes. Outcomes were predicted using univariate and multivariable models, including clinical data and scores. MEASUREMENTS AND MAIN RESULTS: MRI scores significantly correlated with severities and predicted respiratory support at neonatal ICU discharge (P < 0.0001). In multivariable models, MRI scores were by far the strongest predictor of respiratory support duration over clinical data, including birth weight and gestational age. Notably, NICHD severity level was not predictive of discharge support. CONCLUSIONS: Quiet-breathing neonatal pulmonary MRI can independently assess structural abnormalities of BPD, describe disease severity, and predict short-term outcomes more accurately than any individual standard clinical measure. Importantly, this nonionizing technique can be implemented to phenotype disease, and has potential to serially assess efficacy of individualized therapies.


Assuntos
Displasia Broncopulmonar/diagnóstico por imagem , Displasia Broncopulmonar/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Respiração Artificial/métodos , Displasia Broncopulmonar/terapia , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Masculino , Valor Preditivo dos Testes , Nascimento Prematuro , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Fatores de Tempo
13.
Magn Reson Med ; 77(3): 1284-1295, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-26972576

RESUMO

PURPOSE: To implement pulmonary three-dimensional (3D) radial ultrashort echo-time (UTE) MRI in non-sedated, free-breathing neonates and adults with retrospective motion tracking of respiratory and intermittent bulk motion, to obtain diagnostic-quality, respiratory-gated images. METHODS: Pulmonary 3D radial UTE MRI was performed at 1.5 tesla (T) during free breathing in neonates and adult volunteers for validation. Motion-tracking waveforms were obtained from the time course of each free induction decay's initial point (i.e., k-space center), allowing for respiratory-gated image reconstructions that excluded data acquired during bulk motion. Tidal volumes were calculated from end-expiration and end-inspiration images. Respiratory rates were calculated from the Fourier transform of the motion-tracking waveform during quiet breathing, with comparison to physiologic prediction in neonates and validation with spirometry in adults. RESULTS: High-quality respiratory-gated anatomic images were obtained at inspiration and expiration, with less respiratory blurring at the expense of signal-to-noise for narrower gating windows. Inspiration-expiration volume differences agreed with physiologic predictions (neonates; Bland-Altman bias = 6.2 mL) and spirometric values (adults; bias = 0.11 L). MRI-measured respiratory rates compared well with the observed rates (biases = -0.5 and 0.2 breaths/min for neonates and adults, respectively). CONCLUSIONS: Three-dimensional radial pulmonary UTE MRI allows for retrospective respiratory self-gating and removal of intermittent bulk motion in free-breathing, non-sedated neonates and adults. Magn Reson Med 77:1284-1295, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Artefatos , Displasia Broncopulmonar/diagnóstico por imagem , Hérnia Diafragmática/diagnóstico por imagem , Aumento da Imagem/métodos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Adulto , Algoritmos , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Recém-Nascido , Masculino , Movimento (Física) , Reprodutibilidade dos Testes , Mecânica Respiratória , Estudos Retrospectivos , Sensibilidade e Especificidade , Técnica de Subtração
14.
J Pediatr ; 188: 96-102.e1, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28669608

RESUMO

OBJECTIVE: To evaluate postnatal lung volume in infants with congenital diaphragmatic hernia (CDH) and determine if a compensatory increase in lung volume occurs during the postnatal period. STUDY DESIGN: Using a novel pulmonary magnetic resonance imaging method for imaging neonatal lungs, the postnatal lung volumes in infants with CDH were determined and compared with prenatal lung volumes obtained via late gestation magnetic resonance imaging. RESULTS: Infants with left-sided CDH (2 mild, 9 moderate, and 1 severe) were evaluated. The total lung volume increased in all infants, with the contralateral lung increasing faster than the ipsilateral lung (mean ± SD: 4.9 ± 3.0 mL/week vs 3.4 ± 2.1 mL/week, P = .005). In contrast to prenatal studies, the volume of lungs of infants with more severe CDH grew faster than the lungs of infants with more mild CDH (Spearman's ρ=-0.086, P = .01). Although the contralateral lung volume grew faster in both mild and moderate groups, the majority of total lung volume growth in moderate CDH came from increased volume of the ipsilateral lung (42% of total lung volume increase in the moderate group vs 32% of total lung volume increase in the mild group, P = .09). Analysis of multiple clinical variables suggests that increased weight gain was associated with increased compensatory ipsilateral lung volume growth (ρ = 0.57, P = .05). CONCLUSIONS: These results suggest a potential for postnatal catch-up growth in infants with pulmonary hypoplasia and suggest that weight gain may increase the volume growth of the more severely affected lung.


Assuntos
Hérnias Diafragmáticas Congênitas/fisiopatologia , Pulmão/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Pulmão/crescimento & desenvolvimento , Medidas de Volume Pulmonar/métodos , Masculino , Gravidez
15.
J Magn Reson Imaging ; 45(2): 463-471, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27458992

RESUMO

PURPOSE: To determine the feasibility of pulmonary magnetic resonance imaging (MRI) of neonatal lung structures enabled by combining two novel technologies: first, a 3D radial ultrashort echo time (UTE) pulse sequence capable of high spatial resolution full-chest imaging in nonsedated quiet-breathing neonates; and second, a unique, small-footprint 1.5T MRI scanner design adapted for neonatal imaging and installed within the neonatal intensive care unit (NICU). MATERIALS AND METHODS: Ten patients underwent MRI within the NICU, in accordance with an approved Institutional Review Board protocol. Five had clinical diagnoses of bronchopulmonary dysplasia (BPD), and five had putatively normal lung function. Pulmonary imaging was performed at 1.5T using 3D radial UTE and standard 3D fast gradient recalled echo (FGRE). Diagnostic quality, presence of motion artifacts, and apparent severity of lung pathology were evaluated by two radiologists. Quantitative metrics were additionally used to evaluate lung parenchymal signal. RESULTS: UTE images showed significantly higher signal in lung parenchyma (P < 0.0001) and fewer apparent motion artifacts compared to FGRE (P = 0.046). Pulmonary pathology was more severe in patients diagnosed with BPD relative to controls (P = 0.001). Infants diagnosed with BPD also had significantly higher signal in lung parenchyma, measured using UTE, relative to controls (P = 0.002). CONCLUSION: These results demonstrate the technical feasibility of pulmonary MRI in free-breathing, nonsedated infants in the NICU at high, isotropic resolutions approaching that achievable with computed tomography (CT). There is potential for pulmonary MRI to play a role in improving how clinicians understand and manage care of neonatal and pediatric pulmonary diseases. J. Magn. Reson. Imaging 2016. LEVEL OF EVIDENCE: 2 J. Magn. Reson. Imaging 2017;45:463-471.


Assuntos
Imageamento Tridimensional/instrumentação , Unidades de Terapia Intensiva Neonatal , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/instrumentação , Masculino , Miniaturização , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
J Magn Reson Imaging ; 46(4): 992-1000, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28160357

RESUMO

PURPOSE: To demonstrate that ultrashort echo time (UTE) magnetic resonance imaging (MRI) can achieve computed tomography (CT)-like quantification of lung parenchyma in free-breathing, non-sedated neonates. Because infant CTs are used sparingly, parenchymal disease evaluation via UTE MRI has potential for translational impact. MATERIALS AND METHODS: Two neonatal control cohorts without suspected pulmonary morbidities underwent either a research UTE MRI (n = 5; 1.5T) or a clinically-ordered CT (n = 9). Whole-lung means and anterior-posterior gradients of UTE-measured image intensity (arbitrary units, au, normalized to muscle) and CT-measured density (g/cm3 ) were compared (Mann-Whitney U-test). Separately, a diseased neonatal cohort (n = 5) with various pulmonary morbidities underwent both UTE MRI and CT. UTE intensity and CT density were compared with Spearman correlations within ∼33 anatomically matched regions of interest (ROIs) in each diseased subject, spanning low- to high-density tissues. Radiological classifications were evaluated in all ROIs, with mean UTE intensities and CT densities compared in each classification. RESULTS: In control subjects, whole-lung UTE intensities (0.51 ± 0.04 au) were similar to CT densities (0.44 ± 0.09 g/cm3 ) (P = 0.062), as were UTE (0.021 ± 0.020 au/cm) and CT (0.034 ± 0.024 [g/cm3 ]/cm) anterior-posterior gradients (P = 0.351). In diseased subjects' ROIs, significant correlations were observed between UTE and CT (P ≤0.007 in each case). Relative differences between UTE and CT were small in all classifications (4-25%). CONCLUSION: These results demonstrate a strong association between UTE image intensity and CT density, both between whole-lung tissue in control patients and regional radiological pathologies in diseased patients. This indicates the potential for UTE MRI to longitudinally evaluate neonatal pulmonary disease and to provide visualization of pathologies similar to CT, without sedation/anesthesia or ionizing radiation. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017;46:992-1000.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Pneumopatias/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Recém-Nascido , Pulmão/anatomia & histologia , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Am J Respir Crit Care Med ; 192(10): 1215-22, 2015 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-26186608

RESUMO

RATIONALE: Bronchopulmonary dysplasia (BPD) is a prevalent yet poorly characterized pulmonary complication of premature birth; the current definition is based solely on oxygen dependence at 36 weeks postmenstrual age without objective measurements of structural abnormalities across disease severity. OBJECTIVES: We hypothesize that magnetic resonance imaging (MRI) can spatially resolve and quantify the structural abnormalities of the neonatal lung parenchyma associated with premature birth. METHODS: Using a unique, small-footprint, 1.5-T MRI scanner within our neonatal intensive care unit (NICU), diagnostic-quality MRIs using commercially available sequences (gradient echo and spin echo) were acquired during quiet breathing in six patients with BPD, six premature patients without diagnosed BPD, and six full-term NICU patients (gestational ages, 23-39 wk) at near term-equivalent age, without administration of sedation or intravenous contrast. Images were scored by a radiologist using a modified Ochiai score, and volumes of high- and low-signal intensity lung parenchyma were quantified by segmentation and threshold analysis. MEASUREMENTS AND MAIN RESULTS: Signal increases, putatively combinations of fibrosis, edema, and atelectasis, were present in all premature infants. Infants with diagnosed BPD had significantly greater volume of high-signal lung (mean ± SD, 26.1 ± 13.8%) compared with full-term infants (7.3 ± 8.2%; P = 0.020) and premature infants without BPD (8.2 ± 6.4%; P = 0.026). Signal decreases, presumably alveolar simplification, only appeared in the most severe BPD cases, although cystic appearance did increase with severity. CONCLUSIONS: Pulmonary MRI reveals quantifiable, significant differences between patients with BPD, premature patients without BPD, and full-term control subjects. These methods could be implemented to individually phenotype disease, which may impact clinical care and predict future outcomes.


Assuntos
Displasia Broncopulmonar/patologia , Pulmão/patologia , Imageamento por Ressonância Magnética/métodos , Displasia Broncopulmonar/diagnóstico , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Recém-Nascido de muito Baixo Peso , Unidades de Terapia Intensiva Neonatal , Imageamento por Ressonância Magnética/instrumentação
20.
Pediatr Radiol ; 46(13): 1804-1812, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27576458

RESUMO

BACKGROUND: The use of quantitative CT analysis in children is limited by lack of normal values of lung parenchymal attenuation. These characteristics are important because normal lung development yields significant parenchymal attenuation changes as children age. OBJECTIVE: To perform quantitative characterization of normal pediatric lung parenchymal X-ray CT attenuation under routine clinical conditions in order to establish a baseline comparison to that seen in pathological lung conditions. MATERIALS AND METHODS: We conducted a retrospective query of normal CT chest examinations in children ages 0-7 years from 2004 to 2014 using standard clinical protocol. During these examinations semi-automated lung parenchymal segmentation was performed to measure lung volume and mean lung attenuation. RESULTS: We analyzed 42 CT examinations in 39 children, ages 3 days to 83 months (mean ± standard deviation [SD] = 42 ± 27 months). Lung volume ranged 0.10-1.72 liters (L). Mean lung attenuation was much higher in children younger than 12 months, with values as high as -380 Hounsfield units (HU) in neonates (lung volume 0.10 L). Lung volume decreased to approximately -650 HU by age 2 years (lung volume 0.47 L), with subsequently slower exponential decrease toward a relatively constant value of -860 HU as age and lung volume increased. CONCLUSION: Normal lung parenchymal X-ray CT attenuation decreases with increasing lung volume and age; lung attenuation decreases rapidly in the first 2 years of age and more slowly thereafter. This change in normal lung attenuation should be taken into account as quantitative CT methods are translated to pediatric pulmonary imaging.


Assuntos
Pulmão/diagnóstico por imagem , Pulmão/crescimento & desenvolvimento , Tomografia Computadorizada por Raios X/métodos , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Medidas de Volume Pulmonar , Masculino , Radiografia Torácica , Valores de Referência , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA