Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 642
Filtrar
1.
Hum Mol Genet ; 32(7): 1072-1082, 2023 03 20.
Artigo em Inglês | MEDLINE | ID: mdl-36269083

RESUMO

BACKGROUND: Variants in KCNH2, encoding the human ether a-go-go (hERG) channel that is responsible for the rapid component of the cardiac delayed rectifier K+ current (IKr), are causal to long QT syndrome type 2 (LQTS2). We identified eight index patients with a new variant of unknown significance (VUS), KCNH2:c.2717C > T:p.(Ser906Leu). We aimed to elucidate the biophysiological effect of this variant, to enable reclassification and consequent clinical decision-making. METHODS: A genotype-phenotype overview of the patients and relatives was created. The biophysiological effects were assessed independently by manual-, and automated calibrated patch clamp. HEK293a cells expressing (i) wild-type (WT) KCNH2, (ii) KCNH2-p.S906L alone (homozygous, Hm) or (iii) KCNH2-p.S906L in combination with WT (1:1) (heterozygous, Hz) were used for manual patching. Automated patch clamp measured the variants function against known benign and pathogenic variants, using Flp-In T-rex HEK293 KCNH2-variant cell lines. RESULTS: Incomplete penetrance of LQTS2 in KCNH2:p.(Ser906Leu) carriers was observed. In addition, some patients were heterozygous for other VUSs in CACNA1C, PKP2, RYR2 or AKAP9. The phenotype of carriers of KCNH2:p.(Ser906Leu) ranged from asymptomatic to life-threatening arrhythmic events. Manual patch clamp showed a reduced current density by 69.8 and 60.4% in KCNH2-p.S906L-Hm and KCNH2-p.S906L-Hz, respectively. The time constant of activation was significantly increased with 80.1% in KCNH2-p.S906L-Hm compared with KCNH2-WT. Assessment of KCNH2-p.S906L-Hz by calibrated automatic patch clamp assay showed a reduction in current density by 35.6%. CONCLUSION: The reduced current density in the KCNH2-p.S906L-Hz indicates a moderate loss-of-function. Combined with the reduced penetrance and variable phenotype, we conclude that KCNH2:p.(Ser906Leu) is a low penetrant likely pathogenic variant for LQTS2.


Assuntos
Síndrome do QT Longo , Humanos , Síndrome do QT Longo/genética , Síndrome do QT Longo/metabolismo , Canais de Potássio Éter-A-Go-Go/genética , Células HEK293 , Penetrância , Coração , Canal de Potássio ERG1/genética
2.
Eur Heart J ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38747976

RESUMO

BACKGROUND AND AIMS: Brugada syndrome (BrS) is an inherited arrhythmia with a higher disease prevalence and more lethal arrhythmic events in Asians than in Europeans. Genome-wide association studies (GWAS) have revealed its polygenic architecture mainly in European populations. The aim of this study was to identify novel BrS-associated loci and to compare allelic effects across ancestries. METHODS: A GWAS was conducted in Japanese participants, involving 940 cases and 1634 controls, followed by a cross-ancestry meta-analysis of Japanese and European GWAS (total of 3760 cases and 11 635 controls). The novel loci were characterized by fine-mapping, gene expression, and splicing quantitative trait associations in the human heart. RESULTS: The Japanese-specific GWAS identified one novel locus near ZSCAN20 (P = 1.0 × 10-8), and the cross-ancestry meta-analysis identified 17 association signals, including six novel loci. The effect directions of the 17 lead variants were consistent (94.1%; P for sign test = 2.7 × 10-4), and their allelic effects were highly correlated across ancestries (Pearson's R = .91; P = 2.9 × 10-7). The genetic risk score derived from the BrS GWAS of European ancestry was significantly associated with the risk of BrS in the Japanese population [odds ratio 2.12 (95% confidence interval 1.94-2.31); P = 1.2 × 10-61], suggesting a shared genetic architecture across ancestries. Functional characterization revealed that a lead variant in CAMK2D promotes alternative splicing, resulting in an isoform switch of calmodulin kinase II-δ, favouring a pro-inflammatory/pro-death pathway. CONCLUSIONS: This study demonstrates novel susceptibility loci implicating potentially novel pathogenesis underlying BrS. Despite differences in clinical expressivity and epidemiology, the polygenic architecture of BrS was substantially shared across ancestries.

3.
Eur Heart J ; 45(7): 538-548, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38195003

RESUMO

BACKGROUND AND AIMS: Implantable cardioverter-defibrillators (ICDs) are critical for preventing sudden cardiac death (SCD) in arrhythmogenic right ventricular cardiomyopathy (ARVC). This study aims to identify cross-continental differences in utilization of primary prevention ICDs and survival free from sustained ventricular arrhythmia (VA) in ARVC. METHODS: This was a retrospective analysis of ARVC patients without prior VA enrolled in clinical registries from 11 countries throughout Europe and North America. Patients were classified according to whether they received treatment in North America or Europe and were further stratified by baseline predicted VA risk into low- (<10%/5 years), intermediate- (10%-25%/5 years), and high-risk (>25%/5 years) groups. Differences in ICD implantation and survival free from sustained VA events (including appropriate ICD therapy) were assessed. RESULTS: One thousand ninety-eight patients were followed for a median of 5.1 years; 554 (50.5%) received a primary prevention ICD, and 286 (26.0%) experienced a first VA event. After adjusting for baseline risk factors, North Americans were more than three times as likely to receive ICDs {hazard ratio (HR) 3.1 [95% confidence interval (CI) 2.5, 3.8]} but had only mildly increased risk for incident sustained VA [HR 1.4 (95% CI 1.1, 1.8)]. North Americans without ICDs were at higher risk for incident sustained VA [HR 2.1 (95% CI 1.3, 3.4)] than Europeans. CONCLUSIONS: North American ARVC patients were substantially more likely than Europeans to receive primary prevention ICDs across all arrhythmic risk strata. A lower rate of ICD implantation in Europe was not associated with a higher rate of VA events in those without ICDs.


Assuntos
Displasia Arritmogênica Ventricular Direita , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/epidemiologia , Displasia Arritmogênica Ventricular Direita/terapia , Estudos Retrospectivos , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Fatores de Risco , América do Norte/epidemiologia , Europa (Continente)/epidemiologia
4.
Circulation ; 147(21): 1622-1633, 2023 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-37216437

RESUMO

Brugada syndrome (BrS), early repolarization syndrome (ERS), and idiopathic ventricular fibrillation (iVF) have long been considered primary electrical disorders associated with malignant ventricular arrhythmia and sudden cardiac death. However, recent studies have revealed the presence of subtle microstructural abnormalities of the extracellular matrix in some cases of BrS, ERS, and iVF, particularly within right ventricular subepicardial myocardium. Substrate-based ablation within this region has been shown to ameliorate the electrocardiographic phenotype and to reduce arrhythmia frequency in BrS. Patients with ERS and iVF may also exhibit low-voltage and fractionated electrograms in the ventricular subepicardial myocardium, which can be treated with ablation. A significant proportion of patients with BrS and ERS, as well as some iVF survivors, harbor pathogenic variants in the voltage-gated sodium channel gene, SCN5A, but the majority of genetic susceptibility of these disorders is likely to be polygenic. Here, we postulate that BrS, ERS, and iVF may form part of a spectrum of subtle subepicardial cardiomyopathy. We propose that impaired sodium current, along with genetic and environmental susceptibility, precipitates a reduction in epicardial conduction reserve, facilitating current-to-load mismatch at sites of structural discontinuity, giving rise to electrocardiographic changes and the arrhythmogenic substrate.


Assuntos
Síndrome de Brugada , Cardiomiopatias , Humanos , Arritmias Cardíacas , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/genética , Síndrome de Brugada/complicações , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Eletrocardiografia , Cardiomiopatias/diagnóstico , Cardiomiopatias/genética
5.
Circulation ; 147(21): 1568-1578, 2023 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-36960730

RESUMO

BACKGROUND: Treatment options for high-risk Brugada syndrome (BrS) with recurrent ventricular fibrillation (VF) are limited. Catheter ablation is increasingly performed but a large study with long-term outcome data is lacking. We report the results of the multicenter, international BRAVO (Brugada Ablation of VF Substrate Ongoing Registry) for treatment of high-risk symptomatic BrS. METHODS: We enrolled 159 patients (median age 42 years; 156 male) with BrS and spontaneous VF in BRAVO; 43 (27%) of them had BrS and early repolarization pattern. All but 5 had an implantable cardioverter-defibrillator for cardiac arrest (n=125) or syncope (n=34). A total of 140 (88%) had experienced numerous implantable cardioverter-defibrillator shocks for spontaneous VF before ablation. All patients underwent a percutaneous epicardial substrate ablation with electroanatomical mapping except for 8 who underwent open-thoracotomy ablation. RESULTS: In all patients, VF/BrS substrates were recorded in the epicardial surface of the right ventricular outflow tract; 45 (29%) patients also had an arrhythmic substrate in the inferior right ventricular epicardium and 3 in the posterior left ventricular epicardium. After a single ablation procedure, 128 of 159 (81%) patients remained free of VF recurrence; this number increased to 153 (96%) after a repeated procedure (mean 1.2±0.5 procedures; median=1), with a mean follow-up period of 48±29 months from the last ablation. VF burden and frequency of shocks decreased significantly from 1.1±2.1 per month before ablation to 0.003±0.14 per month after the last ablation (P<0.0001). The Kaplan-Meier VF-free survival beyond 5 years after the last ablation was 95%. The only variable associated with a VF-free outcome in multivariable analysis was normalization of the type 1 Brugada ECG, both with and without sodium-channel blockade, after the ablation (hazard ratio, 0.078 [95% CI, 0.008 to 0.753]; P=0.0274). There were no arrhythmic or cardiac deaths. Complications included hemopericardium in 4 (2.5%) patients. CONCLUSIONS: Ablation treatment is safe and highly effective in preventing VF recurrence in high-risk BrS. Prospective studies are needed to determine whether it can be an alternative treatment to implantable cardioverter-defibrillator implantation for selected patients with BrS. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT04420078.


Assuntos
Síndrome de Brugada , Ablação por Cateter , Desfibriladores Implantáveis , Humanos , Masculino , Adulto , Fibrilação Ventricular , Eletrocardiografia/métodos , Ventrículos do Coração , Síndrome de Brugada/cirurgia , Síndrome de Brugada/complicações , Desfibriladores Implantáveis/efeitos adversos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Sistema de Registros
6.
Circulation ; 148(25): 2029-2037, 2023 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-37886885

RESUMO

BACKGROUND: In severely affected patients with catecholaminergic polymorphic ventricular tachycardia, beta-blockers are often insufficiently protective. The purpose of this study was to evaluate whether flecainide is associated with a lower incidence of arrhythmic events (AEs) when added to beta-blockers in a large cohort of patients with catecholaminergic polymorphic ventricular tachycardia. METHODS: From 2 international registries, this multicenter case cross-over study included patients with a clinical or genetic diagnosis of catecholaminergic polymorphic ventricular tachycardia in whom flecainide was added to beta-blocker therapy. The study period was defined as the period in which background therapy (ie, beta-blocker type [beta1-selective or nonselective]), left cardiac sympathetic denervation, and implantable cardioverter defibrillator treatment status, remained unchanged within individual patients and was divided into pre-flecainide and on-flecainide periods. The primary end point was AEs, defined as sudden cardiac death, sudden cardiac arrest, appropriate implantable cardioverter defibrillator shock, and arrhythmic syncope. The association of flecainide with AE rates was assessed using a generalized linear mixed model assuming negative binomial distribution and random effects for patients. RESULTS: A total of 247 patients (123 [50%] females; median age at start of flecainide, 18 years [interquartile range, 14-29]; median flecainide dose, 2.2 mg/kg per day [interquartile range, 1.7-3.1]) were included. At baseline, all patients used a beta-blocker, 70 (28%) had an implantable cardioverter defibrillator, and 21 (9%) had a left cardiac sympathetic denervation. During a median pre-flecainide follow-up of 2.1 years (interquartile range, 0.4-7.2), 41 patients (17%) experienced 58 AEs (annual event rate, 5.6%). During a median on-flecainide follow-up of 2.9 years (interquartile range, 1.0-6.0), 23 patients (9%) experienced 38 AEs (annual event rate, 4.0%). There were significantly fewer AEs after initiation of flecainide (incidence rate ratio, 0.55 [95% CI, 0.38-0.83]; P=0.007). Among patients who were symptomatic before diagnosis or during the pre-flecainide period (n=167), flecainide was associated with significantly fewer AEs (incidence rate ratio, 0.49 [95% CI, 0.31-0.77]; P=0.002). Among patients with ≥1 AE on beta-blocker therapy (n=41), adding flecainide was also associated with significantly fewer AEs (incidence rate ratio, 0.25 [95% CI, 0.14-0.45]; P<0.001). CONCLUSIONS: For patients with catecholaminergic polymorphic ventricular tachycardia, adding flecainide to beta-blocker therapy was associated with a lower incidence of AEs in the overall cohort, in symptomatic patients, and particularly in patients with breakthrough AEs while on beta-blocker therapy.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Feminino , Humanos , Adolescente , Masculino , Flecainida/efeitos adversos , Incidência , Estudos Cross-Over , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/tratamento farmacológico , Taquicardia Ventricular/epidemiologia , Antagonistas Adrenérgicos beta/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle
7.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38349347

RESUMO

AIMS: In patients with catecholaminergic polymorphic ventricular tachycardia (CPVT), a rare inherited arrhythmia syndrome, arrhythmic events can be prevented by medication and lifestyle recommendations. In patients who experience breakthrough arrhythmic events, non-adherence plays an essential role. We aimed to investigate the incidence and potential reasons for non-adherence to medication and lifestyle recommendations in a large, international cohort of patients with CPVT. METHODS AND RESULTS: An online multilingual survey was shared with CPVT patients worldwide by their cardiologists, through peer-recruitment, and on social media from November 2022 until July 2023. Self-reported non-adherence was measured using the validated Medication Adherence Rating Scale (MARS) and a newly developed questionnaire about lifestyle. Additionally, validated questionnaires were used to assess potential reasons for medication non-adherence. Two-hundred-and-eighteen patients completed the survey, of whom 200 (92%) were prescribed medication [122 (61%) female; median age 33.5 years (interquartile range: 22-50)]. One-hundred-and-three (52%) were prescribed beta-blocker and flecainide, 85 (43%) beta-blocker, and 11 (6%) flecainide. Thirty-four (17%) patients experienced a syncope, aborted cardiac arrest or appropriate implantable cardioverter defibrillator shock after diagnosis. Nineteen (13.4%) patients were exercising more than recommended. Thirty (15%) patients were non-adherent to medication. Female sex [odds ratio (OR) 3.7, 95% confidence interval (CI) 1.3-12.0, P = 0.019], flecainide monotherapy compared to combination therapy (OR 6.8, 95% CI 1.6-31.0, P = 0.010), and a higher agreement with statements regarding concerns about CPVT medication (OR 1.2, 95% CI 1.1-1.3, P < 0.001) were independently associated with non-adherence. CONCLUSION: The significant rate of non-adherence associated with concerns regarding CPVT-related medication, emphasizes the potential for improving therapy adherence by targeted patient education.


Assuntos
Flecainida , Taquicardia Ventricular , Humanos , Feminino , Adulto , Masculino , Flecainida/efeitos adversos , Antiarrítmicos/uso terapêutico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/tratamento farmacológico , Taquicardia Ventricular/epidemiologia , Estilo de Vida , Adesão à Medicação , Canal de Liberação de Cálcio do Receptor de Rianodina
8.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38558121

RESUMO

AIMS: Recently, a genetic variant-specific prediction model for phospholamban (PLN) p.(Arg14del)-positive individuals was developed to predict individual major ventricular arrhythmia (VA) risk to support decision-making for primary prevention implantable cardioverter defibrillator (ICD) implantation. This model predicts major VA risk from baseline data, but iterative evaluation of major VA risk may be warranted considering that the risk factors for major VA are progressive. Our aim is to evaluate the diagnostic performance of the PLN p.(Arg14del) risk model at 3-year follow-up. METHODS AND RESULTS: We performed a landmark analysis 3 years after presentation and selected only patients with no prior major VA. Data were collected of 268 PLN p.(Arg14del)-positive subjects, aged 43.5 ± 16.3 years, 38.9% male. After the 3 years landmark, subjects had a mean follow-up of 4.0 years (± 3.5 years) and 28 (10%) subjects experienced major VA with an annual event rate of 2.6% [95% confidence interval (CI) 1.6-3.6], defined as sustained VA, appropriate ICD intervention, or (aborted) sudden cardiac death. The PLN p.(Arg14del) risk score yielded good discrimination in the 3 years landmark cohort with a C-statistic of 0.83 (95% CI 0.79-0.87) and calibration slope of 0.97. CONCLUSION: The PLN p.(Arg14del) risk model has sustained good model performance up to 3 years follow-up in PLN p.(Arg14del)-positive subjects with no history of major VA. It may therefore be used to support decision-making for primary prevention ICD implantation not merely at presentation but also up to at least 3 years of follow-up.


Assuntos
Arritmias Cardíacas , Desfibriladores Implantáveis , Feminino , Humanos , Masculino , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/genética , Arritmias Cardíacas/terapia , Proteínas de Ligação ao Cálcio/genética , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Reprodutibilidade dos Testes , Fatores de Risco , Adulto , Pessoa de Meia-Idade
9.
BJOG ; 131(9): 1290-1295, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38326282

RESUMO

OBJECTIVE: Data and guidelines are lacking, so implantable cardioverter-defibrillators (ICDs) are often deactivated during labour to prevent inappropriate shocks. This study aimed to ascertain the safety of an activated ICD during labour. DESIGN: An observational study was performed. SETTING: Dutch hospitals. POPULATION OR SAMPLE: A total of 41 childbirths were included of 26 patients who gave birth between February 2009 and November 2018 after receiving an ICD in our tertiary hospital. Five of these childbirths were attended by the research team between December 2018 and August 2020, during which the ICD remained active. METHODS: Groups were made based on ICD status during labour. Patients who gave birth with an activated ICD at least once were stratified to the activated ICD group. Patients' files were checked and patients received a questionnaire about childbirth perceptions and treatment preferences. The differences in ordinal data resulting from the questionnaire were calculated using a chi-square or Fisher's exact test. MAIN OUTCOME MEASURES: Primary outcome was inappropriate ICD therapy and occurrence of ventricular arrhythmias requiring treatment. RESULTS: During the 41 childbirths, no inappropriate shocks or ventricular arrhythmias occurred during labour. All patients in the activated ICD group (n = 13) preferred this setting, while 8 of the 13 patients in the deactivated ICD group preferred activation (p = 0.002). Reasons included avoiding hemodynamic monitoring, magnet placement, or labour induction to facilitate technician availability. CONCLUSIONS: This study shows no evidence that labour and birth in women with an activated ICD are unsafe, as there were no ventricular arrhythmias or inappropriate therapy. In addition, most patients prefer an activated ICD during labour.


Assuntos
Desfibriladores Implantáveis , Humanos , Feminino , Desfibriladores Implantáveis/efeitos adversos , Adulto , Gravidez , Países Baixos , Arritmias Cardíacas/terapia , Trabalho de Parto , Inquéritos e Questionários , Segurança do Paciente , Parto , Complicações Cardiovasculares na Gravidez/terapia
10.
Adv Exp Med Biol ; 1441: 977-990, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38884765

RESUMO

The identification of a disease-causing variant in a patient diagnosed with cardiomyopathy allows for presymptomatic testing in at risk relatives. Carriers of a pathogenic variant can subsequently be screened at intervals by a cardiologist to assess the risk for potentially life-threatening arrhythmias which can be life-saving. In addition, gene-specific recommendations for risk stratification and disease specific pharmacological options for therapy are beginning to emerge. The large variability in disease penetrance, symptoms, and prognosis, and in some families even in cardiomyopathy subtype, makes genetic counseling both of great importance and complicated.


Assuntos
Cardiomiopatias , Humanos , Cardiomiopatias/genética , Aconselhamento Genético , Predisposição Genética para Doença/genética , Testes Genéticos/métodos , Mutação
11.
Eur Heart J ; 44(27): 2427-2439, 2023 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-37345279

RESUMO

The diagnosis of Brugada syndrome (BrS) requires the presence of a coved (Type 1) ST segment elevation in the right precordial leads of the electrocardiogram (ECG). The dynamic nature of the ECG is well known, and in patients with suspected BrS but non-diagnostic ECG at baseline, a sodium channel blocker test (SCBT) is routinely used to unmask BrS. There is little doubt, however, that in asymptomatic patients, a drug-induced Brugada pattern is associated with a much better prognosis compared to a spontaneous Type 1 ECG. The SCBT is also increasingly used to delineate the arrhythmogenic substrate during ablation studies. In the absence of a "gold standard" for the diagnosis of BrS, sensitivity and specificity of the SCBT remain elusive. By studying patient groups with different underlying diseases, it has become clear that the specificity of the test may not be optimal. This review aims to discuss the pitfalls of the SCBT and provides some directions in whom and when to perform the test. It is concluded that because of the debated specificity and the overall very low risk for future events in asymptomatic individuals, patients should be properly selected and counseled before SCBT is performed and that SCBT should not be performed in asymptomatic patients with a Type 2 Brugada pattern and no family history of BrS or sudden death.


Assuntos
Síndrome de Brugada , Humanos , Síndrome de Brugada/diagnóstico , Eletrocardiografia , Bloqueadores dos Canais de Sódio , Prognóstico , Morte Súbita
12.
Cardiol Young ; : 1-8, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38653721

RESUMO

Despite its low prevalence, the potential diagnosis of catecholaminergic polymorphic ventricular tachycardia (CPVT) should be at the forefront of a paediatric cardiologists mind in children with syncope during exercise or emotions. Over the years, the number of children with a genetic diagnosis of CPVT due to a (likely) pathogenic RYR2 variant early in life and prior to the onset of symptoms has increased due to cascade screening programmes. Limited guidance for this group of patients is currently available. Therefore, we aimed to summarise currently available literature for asymptomatic patients with a (likely) pathogenic RYR2 variant, particularly the history of CPVT and its genetic architecture, the currently available diagnostic tests and their limitations, and the development of a CPVT phenotype - both electrocardiographically and symptomatic - of affected family members. Their risk of arrhythmic events is presumably low and a phenotype seems to develop in the first two decades of life. Future research should focus on this group in particular, to better understand the development of a phenotype over time, and therefore, to be able to better guide clinical management - including the frequency of diagnostic tests, the timing of the initiation of drug therapy, and lifestyle recommendations.

13.
JAMA ; 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38900490

RESUMO

Importance: Sudden death and cardiac arrest frequently occur without explanation, even after a thorough clinical evaluation. Calcium release deficiency syndrome (CRDS), a life-threatening genetic arrhythmia syndrome, is undetectable with standard testing and leads to unexplained cardiac arrest. Objective: To explore the cardiac repolarization response on an electrocardiogram after brief tachycardia and a pause as a clinical diagnostic test for CRDS. Design, Setting, and Participants: An international, multicenter, case-control study including individual cases of CRDS, 3 patient control groups (individuals with suspected supraventricular tachycardia; survivors of unexplained cardiac arrest [UCA]; and individuals with genotype-positive catecholaminergic polymorphic ventricular tachycardia [CPVT]), and genetic mouse models (CRDS, wild type, and CPVT were used to define the cellular mechanism) conducted at 10 centers in 7 countries. Patient tracings were recorded between June 2005 and December 2023, and the analyses were performed from April 2023 to December 2023. Intervention: Brief tachycardia and a subsequent pause (either spontaneous or mediated through cardiac pacing). Main Outcomes and Measures: Change in QT interval and change in T-wave amplitude (defined as the difference between their absolute values on the postpause sinus beat and the last beat prior to tachycardia). Results: Among 10 case patients with CRDS, 45 control patients with suspected supraventricular tachycardia, 10 control patients who experienced UCA, and 3 control patients with genotype-positive CPVT, the median change in T-wave amplitude on the postpause sinus beat (after brief ventricular tachycardia at ≥150 beats/min) was higher in patients with CRDS (P < .001). The smallest change in T-wave amplitude was 0.250 mV for a CRDS case patient compared with the largest change in T-wave amplitude of 0.160 mV for a control patient, indicating 100% discrimination. Although the median change in QT interval was longer in CRDS cases (P = .002), an overlap between the cases and controls was present. The genetic mouse models recapitulated the findings observed in humans and suggested the repolarization response was secondary to a pathologically large systolic release of calcium from the sarcoplasmic reticulum. Conclusions and Relevance: There is a unique repolarization response on an electrocardiogram after provocation with brief tachycardia and a subsequent pause in CRDS cases and mouse models, which is absent from the controls. If these findings are confirmed in larger studies, this easy to perform maneuver may serve as an effective clinical diagnostic test for CRDS and become an important part of the evaluation of cardiac arrest.

14.
Neth Heart J ; 32(5): 190-197, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38634993

RESUMO

International guidelines recommend implantation of an implantable cardioverter-defibrillator (ICD) in non-ischaemic cardiomyopathy (NICM) patients with a left ventricular ejection fraction (LVEF) below 35% despite optimal medical therapy and a life expectancy of more than 1 year with good functional status. We propose refinement of these recommendations in patients with NICM, with careful consideration of additional risk parameters for both arrhythmic and non-arrhythmic death. These additional parameters include late gadolinium enhancement on cardiac magnetic resonance imaging and genetic testing for high-risk genetic variants to further assess arrhythmic risk, and age, comorbidities and sex for assessment of non-arrhythmic mortality risk. Moreover, several risk modifiers should be taken into account, such as concomitant arrhythmias that may affect LVEF (atrial fibrillation, premature ventricular beats) and resynchronisation therapy. Even though currently no valid cut-off values have been established, the proposed approach provides a more careful consideration of risks that may result in withholding ICD implantation in patients with low arrhythmic risk and substantial non-arrhythmic mortality risk.

15.
Neth Heart J ; 32(6): 238-244, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38653923

RESUMO

BACKGROUND: Idiopathic ventricular fibrillation (iVF) is a rare cause of sudden cardiac arrest and, by definition, a diagnosis of exclusion. Due to the rarity of the disease, previous and current studies are limited by their retrospective design and small patient numbers. Even though the incidence of iVF has declined owing to the identification of new disease entities, an important subgroup of patients remains. AIM: To expand the existing Dutch iVF Registry into a large nationwide cohort of patients initially diagnosed with iVF, to reveal the underlying cause of iVF in these patients, and to improve arrhythmia management. METHODS: The Dutch iVF Registry includes sudden cardiac arrest survivors with an initial diagnosis of iVF. Clinical data and outcomes are collected. Outcomes include subsequent detection of a diagnosis other than 'idiopathic', arrhythmia recurrence and death. Non-invasive electrocardiographic imaging is used to investigate electropathological substrates and triggers of VF. RESULTS: To date, 432 patients have been included in the registry (median age at event 40 years (interquartile range 28-52)), 61% male. During a median follow-up of 6 (2-12) years, 38 patients (9%) received a diagnosis other than 'idiopathic'. Eleven iVF patients were characterised with electrocardiographic imaging. CONCLUSION: The Dutch iVF Registry is currently the largest of its kind worldwide. In this heterogeneous population of index patients, we aim to identify common functional denominators associated with iVF. With the implementation of non-invasive electrocardiographic imaging and other diagnostic modalities (e.g. echocardiographic deformation, cardiac magnetic resonance), we advance the possibilities to reveal pro-fibrillatory substrates.

16.
Circulation ; 146(19): 1434-1443, 2022 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-36205131

RESUMO

BACKGROUND: A novel risk calculator based on clinical characteristics and noninvasive tests that predicts the onset of clinical sustained ventricular arrhythmias (VA) in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC) has been proposed and validated by recent studies. It remains unknown whether programmed ventricular stimulation (PVS) provides additional prognostic value. METHODS: All patients with a definite ARVC diagnosis, no history of sustained VAs at diagnosis, and PVS performed at baseline were extracted from 6 international ARVC registries. The calculator-predicted risk for sustained VA (sustained or implantable cardioverter defibrillator treated ventricular tachycardia [VT] or fibrillation, [aborted] sudden cardiac arrest) was assessed in all patients. Independent and combined performance of the risk calculator and PVS on sustained VA were assessed during a 5-year follow-up period. RESULTS: Two hundred eighty-eight patients (41.0±14.5 years, 55.9% male, right ventricular ejection fraction 42.5±11.1%) were enrolled. At PVS, 137 (47.6%) patients had inducible ventricular tachycardia. During a median of 5.31 [2.89-10.17] years of follow-up, 83 (60.6%) patients with a positive PVS and 37 (24.5%) with a negative PVS experienced sustained VA (P<0.001). Inducible ventricular tachycardia predicted clinical sustained VA during the 5-year follow-up and remained an independent predictor after accounting for the calculator-predicted risk (HR, 2.52 [1.58-4.02]; P<0.001). Compared with ARVC risk calculator predictions in isolation (C-statistic 0.72), addition of PVS inducibility showed improved prediction of VA events (C-statistic 0.75; log-likelihood ratio for nested models, P<0.001). PVS inducibility had a 76% [67-84] sensitivity and 68% [61-74] specificity, corresponding to log-likelihood ratios of 2.3 and 0.36 for inducible (likelihood ratio+) and noninducible (likelihood ratio-) patients, respectively. In patients with a ARVC risk calculator-predicted risk of clinical VA events <25% during 5 years (ie, low/intermediate subgroup), PVS had a 92.6% negative predictive value. CONCLUSIONS: PVS significantly improved risk stratification above and beyond the calculator-predicted risk of VA in a primary prevention cohort of patients with ARVC, mainly for patients considered to be at low and intermediate risk by the clinical risk calculator.


Assuntos
Displasia Arritmogênica Ventricular Direita , Prevenção Primária , Feminino , Humanos , Masculino , Arritmias Cardíacas/epidemiologia , Displasia Arritmogênica Ventricular Direita/epidemiologia , Displasia Arritmogênica Ventricular Direita/prevenção & controle , Morte Súbita Cardíaca/epidemiologia , Desfibriladores Implantáveis , Prevenção Primária/métodos , Medição de Risco/métodos , Fatores de Risco , Volume Sistólico , Taquicardia Ventricular/epidemiologia , Função Ventricular Direita , Adulto , Pessoa de Meia-Idade
17.
Circulation ; 145(5): 321-329, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34779221

RESUMO

BACKGROUND: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) showed noninferiority of subcutaneous implantable cardioverter defibrillator (S-ICD) compared with transvenous implantable cardioverter defibrillator (TV-ICD) with regard to inappropriate shocks and complications. In contrast to TV-ICD, S-ICD cannot provide antitachycardia pacing for monomorphic ventricular tachycardia. This prespecified secondary analysis evaluates appropriate therapy and whether antitachycardia pacing reduces the number of appropriate shocks. METHODS: The PRAETORIAN trial was an international, investigator-initiated randomized trial that included patients with an indication for implantable cardioverter defibrillator (ICD) therapy. Patients with previous ventricular tachycardia <170 bpm or refractory recurrent monomorphic ventricular tachycardia were excluded. In 39 centers, 849 patients were randomized to receive an S-ICD (n=426) or TV-ICD (n=423) and were followed for a median of 49.1 months. ICD programming was mandated by protocol. Appropriate ICD therapy was defined as therapy for ventricular arrhythmias. Arrhythmias were classified as discrete episodes and storm episodes (≥3 episodes within 24 hours). Analyses were performed in the modified intention-to-treat population. RESULTS: In the S-ICD group, 86 of 426 patients received appropriate therapy, versus 78 of 423 patients in the TV-ICD group, during a median follow-up of 52 months (48-month Kaplan-Meier estimates 19.4% and 17.5%; P=0.45). In the S-ICD group, 83 patients received at least 1 shock, versus 57 patients in the TV-ICD group (48-month Kaplan-Meier estimates 19.2% and 11.5%; P=0.02). Patients in the S-ICD group had a total of 254 shocks, compared with 228 shocks in the TV-ICD group (P=0.68). First shock efficacy was 93.8% in the S-ICD group and 91.6% in the TV-ICD group (P=0.40). The first antitachycardia pacing attempt successfully terminated 46% of all monomorphic ventricular tachycardias, but accelerated the arrhythmia in 9.4%. Ten patients with S-ICD experienced 13 electrical storms, versus 18 patients with TV-ICD with 19 electrical storms. Patients with appropriate therapy had an almost 2-fold increased relative risk of electrical storms in the TV-ICD group compared with the S-ICD group (P=0.05). CONCLUSIONS: In this trial, no difference was observed in shock efficacy of S-ICD compared with TV-ICD. Although patients in the S-ICD group were more likely to receive an ICD shock, the total number of appropriate shocks was not different between the 2 groups. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01296022.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/normas , Idoso , Arritmias Cardíacas/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
18.
N Engl J Med ; 383(6): 526-536, 2020 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-32757521

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) was designed to avoid complications related to the transvenous ICD lead by using an entirely extrathoracic placement. Evidence comparing these systems has been based primarily on observational studies. METHODS: We conducted a noninferiority trial in which patients with an indication for an ICD but no indication for pacing were assigned to receive a subcutaneous ICD or transvenous ICD. The primary end point was the composite of device-related complications and inappropriate shocks; the noninferiority margin for the upper boundary of the 95% confidence interval for the hazard ratio (subcutaneous ICD vs. transvenous ICD) was 1.45. A superiority analysis was prespecified if noninferiority was established. Secondary end points included death and appropriate shocks. RESULTS: A total of 849 patients (426 in the subcutaneous ICD group and 423 in the transvenous ICD group) were included in the analyses. At a median follow-up of 49.1 months, a primary end-point event occurred in 68 patients in the subcutaneous ICD group and in 68 patients in the transvenous ICD group (48-month Kaplan-Meier estimated cumulative incidence, 15.1% and 15.7%, respectively; hazard ratio, 0.99; 95% confidence interval [CI], 0.71 to 1.39; P = 0.01 for noninferiority; P = 0.95 for superiority). Device-related complications occurred in 31 patients in the subcutaneous ICD group and in 44 in the transvenous ICD group (hazard ratio, 0.69; 95% CI, 0.44 to 1.09); inappropriate shocks occurred in 41 and 29 patients, respectively (hazard ratio, 1.43; 95% CI, 0.89 to 2.30). Death occurred in 83 patients in the subcutaneous ICD group and in 68 in the transvenous ICD group (hazard ratio, 1.23; 95% CI, 0.89 to 1.70); appropriate shocks occurred in 83 and 57 patients, respectively (hazard ratio, 1.52; 95% CI, 1.08 to 2.12). CONCLUSIONS: In patients with an indication for an ICD but no indication for pacing, the subcutaneous ICD was noninferior to the transvenous ICD with respect to device-related complications and inappropriate shocks. (Funded by Boston Scientific; PRAETORIAN ClinicalTrials.gov number, NCT01296022.).


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Idoso , Cardiomiopatias/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Eletrodos Implantados/efeitos adversos , Falha de Equipamento , Feminino , Seguimentos , Cardiopatias/terapia , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Desenho de Prótese
19.
Europace ; 25(8)2023 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-37622576

RESUMO

Sudden cardiac death (SCD) is responsible for several millions of deaths every year and remains a major health problem. To reduce this burden, diagnosing and identification of high-risk individuals and disease-specific risk stratification are essential. Treatment strategies include treatment of the underlying disease with lifestyle advice and drugs and decisions to implant a primary prevention implantable cardioverter-defibrillator (ICD) and perform ablation of the ventricles and novel treatment modalities such as left cardiac sympathetic denervation in rare specific primary electric diseases such as long QT syndrome and catecholaminergic polymorphic ventricular tachycardia. This review summarizes the current knowledge on SCD risk according to underlying heart disease and discusses the future of SCD prevention.


Assuntos
Desfibriladores Implantáveis , Cardiopatias , Síndrome do QT Longo , Humanos , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Síndrome do QT Longo/complicações , Síndrome do QT Longo/diagnóstico , Síndrome do QT Longo/terapia , Medição de Risco
20.
Europace ; 25(3): 969-977, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36636951

RESUMO

AIMS: Remote monitoring (RM) for implantable cardioverter-defibrillators (ICDs) is advocated for the potential of early detection of disease progression and device dysfunction. While studies have examined the effect of RM on clinical outcomes in carefully selected populations of heart failure patients implanted with ICDs from a single vendor, there is a paucity of data in real-world patients. We aimed to assess the long-term effect of RM in a representative ICD population using real-world data. METHODS AND RESULTS: This is an observational retrospective longitudinal study of 1004 patients implanted with an ICD or cardiac resynchronization therapy device (CRT-D) from all device vendors between 2010 and 2021. Patients started on RM (N = 403) within 90 days following de novo device implantation and yearly in-office visits were compared with patients with only bi-yearly in-office follow-up (non-RM, N = 601). In a propensity score matched cohort of 430 patients (mean age 61.4 ± 14.3 years, 26.7% female), all-cause mortality at 4-year was 12.6% in the RM and 27.7% in the non-RM group [hazard ratio (HR) 0.52, 95% confidence interval (CI) 0.32-0.82; P = 0.005]. No difference in inappropriate ICD-therapy (HR 1.90, 95% CI 0.86-4.21; P = 0.122) was observed. The risk of appropriate ICD-therapy (HR 1.71, 95% CI 1.07-2.74; P = 0.026) was higher in the RM group. CONCLUSION: Remote monitoring was associated with a reduction in long-term all-cause and cardiac mortality compared with traditional office visits in a real-world ICD population.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Estudos Retrospectivos , Estudos Longitudinais , Dispositivos de Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Terapia de Ressincronização Cardíaca/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA