Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.462
Filtrar
1.
Nature ; 606(7913): 281-286, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35585238

RESUMO

Substantial leaps in the understanding of quantum systems have been driven by exploring geometry, topology, dimensionality and interactions in ultracold atomic ensembles1-6. A system where atoms evolve while confined on an ellipsoidal surface represents a heretofore unexplored geometry and topology. Realizing an ultracold bubble-potentially Bose-Einstein condensed-relates to areas of interest including quantized-vortex flow constrained to a closed surface topology, collective modes and self-interference via bubble expansion7-17. Large ultracold bubbles, created by inflating smaller condensates, directly tie into Hubble-analogue expansion physics18-20. Here we report observations from the NASA Cold Atom Lab21 facility onboard the International Space Station of bubbles of ultracold atoms created using a radiofrequency-dressing protocol. We observe bubble configurations of varying size and initial temperature, and explore bubble thermodynamics, demonstrating substantial cooling associated with inflation. We achieve partial coverings of bubble traps greater than one millimetre in size with ultracold films of inferred few-micrometre thickness, and we observe the dynamics of shell structures projected into free-evolving harmonic confinement. The observations are among the first measurements made with ultracold atoms in space, using perpetual freefall to explore quantum systems that are prohibitively difficult to create on Earth. This work heralds future studies (in orbital microgravity) of the Bose-Einstein condensed bubble, the character of its excitations and the role of topology in its evolution.

2.
Clin Gastroenterol Hepatol ; 22(3): 523-531.e3, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37716614

RESUMO

BACKGROUND & AIMS: Guidelines suggest a single screening esophagogastroduodenoscopy (EGD) in patients with multiple risk factors for Barrett's esophagus (BE). We aimed to determine BE prevalence and predictors on repeat EGD after a negative initial EGD, using 2 large national databases (GI Quality Improvement Consortium [GIQuIC] and TriNetX). METHODS: Patients who underwent at least 2 EGDs were included and those with BE or esophageal adenocarcinoma detected at initial EGD were excluded. Patient demographics and prevalence of BE on repeat EGD were collected. Multivariate logistic regression was performed to assess for independent risk factors for BE detected on the repeat EGD. RESULTS: In 214,318 and 153,445 patients undergoing at least 2 EGDs over a median follow-up of 28-35 months, the prevalence of BE on repeat EGD was 1.7% in GIQuIC and 3.4% in TriNetX, respectively (26%-45% of baseline BE prevalence). Most (89%) patients had nondysplastic BE. The prevalence of BE remained stable over time (from 1 to >5 years from negative initial EGD) but increased with increasing number of risk factors. BE prevalence in a high-risk population (gastroesophageal reflux disease plus ≥1 risk factor for BE) was 3%-4%. CONCLUSIONS: In this study of >350,000 patients, rates of BE on repeat EGD ranged from 1.7%-3.4%, and were higher in those with multiple risk factors. Most were likely missed at initial evaluation, underscoring the importance of a high-quality initial endoscopic examination. Although routine repeat endoscopic BE screening after a negative initial examination is not recommended, repeat screening may be considered in carefully selected patients with gastroesophageal reflux disease and ≥2 risk factors for BE, potentially using nonendoscopic tools.


Assuntos
Esôfago de Barrett , Neoplasias Esofágicas , Refluxo Gastroesofágico , Humanos , Esôfago de Barrett/diagnóstico , Esôfago de Barrett/epidemiologia , Esôfago de Barrett/patologia , Prevalência , Neoplasias Esofágicas/diagnóstico , Neoplasias Esofágicas/epidemiologia , Endoscopia Gastrointestinal , Refluxo Gastroesofágico/epidemiologia , Endoscopia do Sistema Digestório
3.
Am J Gastroenterol ; 119(2): 251-261, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37782262

RESUMO

INTRODUCTION: The coronavirus disease 19 (COVID-19) pandemic disrupted endoscopy practices, creating unprecedented decreases in cancer screening and surveillance services. We aimed to assess the impact of the pandemic on the proportion of patients diagnosed with Barrett's esophagus (BE) and BE-related dysplasia and adherence to established quality indicators. METHODS: Data from all esophagogastroduodenoscopies in the GI Quality Improvement Consortium, a national repository of matched endoscopy and pathology data, were analyzed from January 2018 to December 2022. Four cohorts were created based on procedure date and COVID-19 data: pre-pandemic (January 2018 to February 2020), pandemic-phase I (March 2020 to July 2020), pandemic-phase II (August 2020 to May 2021), and pandemic-phase III (June 2021 to December 2022). Observed and expected number of BE and BE-related dysplasia cases per month and adherence to the Seattle biopsy protocol and recommended surveillance intervals for nondysplastic BE (NDBE) were evaluated. RESULTS: Among 2,446,857 esophagogastroduodenoscopies performed during the study period, 104,124 (4.3%) had pathology-confirmed BE. The histologic distribution was 87.4% NDBE, 1.8% low-grade dysplasia, 2.4% indefinite for dysplasia, and 1.4% high-grade dysplasia. The number of monthly BE (-47.9% pandemic-phase I, -21.5% pandemic-phase II, and -19.0% pandemic-phase III) and BE-related dysplasia (high-grade dysplasia: 41.2%, -27.7%, and -19.0%; low-grade dysplasia: 49.1%, -35.3%, and -26.5%; any dysplasia: 46.7%, -32.3%, and -27.9%) diagnoses were significantly reduced during the pandemic phases compared with pre-pandemic data. Adherence rates to the Seattle protocol and recommended surveillance intervals for NDBE did not decline during the pandemic. DISCUSSION: There was a significant decline in the number of BE and BE-related dysplasia diagnoses during the COVID-19 pandemic, with an approximately 50% reduction in the number of cases of dysplasia diagnosed in the early pandemic. The absence of a compensatory increase in diagnoses in the pandemic-phase II and III periods may result in deleterious downstream effects on esophageal adenocarcinoma morbidity and mortality.


Assuntos
Esôfago de Barrett , COVID-19 , Neoplasias Esofágicas , Humanos , Esôfago de Barrett/diagnóstico , Esôfago de Barrett/epidemiologia , Esôfago de Barrett/patologia , Pandemias , Esofagoscopia , Biópsia , COVID-19/epidemiologia , Neoplasias Esofágicas/diagnóstico , Neoplasias Esofágicas/epidemiologia , Neoplasias Esofágicas/patologia , Hiperplasia , Teste para COVID-19
4.
Phys Rev Lett ; 133(9): 093002, 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39270177

RESUMO

We use one-photon excitation to promote K-shell electrons of formic acid (which has a planar equilibrium structure) to an antibonding π^{*} orbital. The excited molecule is known to have a (chiral) pyramidal equilibrium structure. In our experiment, we determine the handedness of the excited molecule by imaging the momenta of charged fragments, which occur after its Coulomb explosion triggered by Auger-Meitner decay cascades succeeding the excitation. We find that the handedness of the excited molecule depends on its spatial orientation with respect to the propagation (or polarization) direction of the exciting photon. The effect is largely independent of the exact polarization properties of the light driving the 1s→π^{*} excitation.

5.
J Chem Phys ; 161(4)2024 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-39056387

RESUMO

We applied reaction microscopy to elucidate fast non-adiabatic dissociation dynamics of deuterated water molecules after direct photo-double ionization at 61 eV with synchrotron radiation. For the very rare D+ + O+ + D breakup channel, the particle momenta, angular, and energy distributions of electrons and ions, measured in coincidence, reveal distinct electronic dication states and their dissociation pathways via spin-orbit coupling and charge transfer at crossings and seams on the potential energy surfaces. Notably, we could distinguish between direct and fast sequential dissociation scenarios. For the latter case, our measurements reveal the geometry and orientation of the deuterated water molecule with respect to the polarization vector that leads to this rare 3-body molecular breakup channel. Aided by multi-reference configuration-interaction calculations, the dissociation dynamics could be traced on the relevant potential energy surfaces and particularly their crossings and seams. This approach also unraveled the ultrafast time scales governing these processes.

6.
J Endocrinol Invest ; 47(2): 421-432, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37550552

RESUMO

PURPOSE: PRESTO 3 evaluated nurses' preference for the Somatuline® Autogel® syringe versus the Lanreotide Pharmathen syringe after injection-pad testing. METHODS: This international simulated-use study included oncology/endocrinology nurses with ≥ 1 years' experience in managing neuroendocrine tumours (NETs) and/or acromegaly. Each nurse tested both syringes twice in a randomised order before completing an electronic survey. The primary objective was to assess overall preference (%, 95% confidence interval [CI]) for the Somatuline Autogel syringe versus the Lanreotide Pharmathen syringe. Secondary objectives included rating syringe performance and ranking the importance of syringe attributes. RESULTS: Ninety-four nurses were enrolled: mean age, 41.0 (SD, 11.5) years. The percentage of nurses stating a preference ("strong" or "slight") for the Somatuline Autogel syringe (86.2% [95% CI 77.5-92.4%]) was significantly higher than 50% (p < 0.0001). Performance rating was significantly higher for the Somatuline Autogel syringe versus Lanreotide Pharmathen syringe for 10 of the 11 attributes tested (p < 0.05). The syringe attributes considered most important when injecting patients in routine clinical practice were "easy to use from preparation to injection" (30.9%) and "comfortable to handle during use from preparation to injection" (16.0%). The attribute most commonly rated as least important was "fast administration from preparation to injection" (26.6%). CONCLUSION: Nurses strongly preferred the user experience of the Somatuline Autogel syringe over the Lanreotide Pharmathen syringe. "Ease of use" and "comfortable to handle" were the most important syringe attributes, and performance rating was significantly higher with Somatuline Autogel versus Lanreotide Pharmathen syringe for all but one attribute.


Drugs called somatostatin analogues (SSAs) can be used to treat patients with neuroendocrine tumours or acromegaly over a prolonged period of time. SSAs are given as injections and act by slowing the production of hormones by the body and in some cases reducing the growth of the tumour. To help to provide the best care possible, it is important that the syringe used for the injection is easy to use and delivers the SSA effectively. Somatuline Autogel is a syringe that can be used to inject an SSA called lanreotide. Previous studies showed that patients and nurses preferred the injection experience when using the Somatuline Autogel syringe compared with a syringe used to inject another SSA called octreotide long-acting release. A new syringe used for lanreotide injections has been developed recently by a company called Pharmathen. In the PRESTO 3 study, we compared the user experience of the Somatuline Autogel syringe and the Lanreotide Pharmathen syringe. We asked 94 nurses from Europe and the US to test both syringes, in a randomised order, using injection pads, and then to answer questions about their overall preference between the two syringes and how well the syringe performed for a set of syringe features. Overall, 86% of nurses preferred the Somatuline Autogel syringe over the Lanreotide Pharmathen syringe. Of the 11 features of the syringe that we assessed, 10 were rated higher for the Somatuline Autogel syringe than the Lanreotide Pharmathen syringe. The syringe features "ease of use" and "comfortable to handle" were considered the most important. The results of the PRESTO 3 study indicated that there is a difference in the user experience between the syringes, particularly for confidence and ease of use, and that it is important to offer syringe choices to nurses who are using SSA injections to treat patients.


Assuntos
Acromegalia , Tumores Neuroendócrinos , Enfermeiras e Enfermeiros , Somatostatina/análogos & derivados , Humanos , Adulto , Acromegalia/tratamento farmacológico , Seringas , Peptídeos Cíclicos
7.
J Dairy Sci ; 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38945260

RESUMO

Breeding animals able to effectively respond to stress could be a long-term, sustainable, and affordable strategy to improve resilience and welfare in livestock systems. In the present study, the concentrations of 29 plasma biomarkers were used as candidate endophenotypes for metabolic stress response in single-SNP, gene- and haplotype-based GWAS using 739 healthy lactating Italian Holstein cows and 88,271 variants. Significant genetic associations were found in all the 3 GWAS approaches for plasma γ-glutamyl transferase concentration on BTA17, for paraoxonase on BTA4, and for alkaline phosphatase and zinc on BTA2. On these chromosomes, single-SNP and gene-based chromosome-wide association studies were performed, confirming GWAS findings. The signals identified for paraoxonase, γ-glutamyl transferase, and alkaline phosphatase were in proximity of the genes coding for them. The heritability of these 4 biomarkers ranged from moderate to high (from 0.39 to 0.54). Plasma biomarkers are known to undergo large changes in concentration during metabolic stress in the transition period, with an inter-individual variability in the rate of change and recovery time. Genetics may account in part for these differences. To assess this, we studied a subset of 139 periparturient cows homozygous at 3 SNPs known to be respectively associated with concentration of plasma ceruloplasmin, paraoxonase and γ-glutamyl transferase. We compared the immune-metabolic profile measured in plasma at -7, +5 and +30 d relative to calving between groups of opposite homozygotes. A significant effect of the genotype was found on paraoxonase and γ-glutamyl transferase plasma concentration at all the 3 time points. No evidence for genotype effect was detected for ceruloplasmin. Understanding the genetic control underlying metabolic stress response may suggest new approaches to foster resilience in dairy cows.

8.
Cogn Emot ; : 1-13, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38712807

RESUMO

Sustained attention, a key cognitive skill that improves during childhood and adolescence, tends to be worse in some emotional and behavioural disorders. Sustained attention is typically studied in non-affective task contexts; here, we used a novel task to index performance in affective versus neutral contexts across adolescence (N = 465; ages 11-18). We asked whether: (i) performance would be worse in negative versus neutral task contexts; (ii) performance would improve with age; (iii) affective interference would be greater in younger adolescents; (iv) adolescents at risk for depression and higher in anxiety would show overall worse performance; and (v) would show differential performance in negative contexts. Results indicated that participants performed more poorly in negative contexts and showed age-related performance improvements. Those at risk of depression performed more poorly than those at lower risk. However, there was no difference between groups as a result of affective context. For anxiety there was no difference in performance as a function of severity. However, those with higher anxiety showed less variance in their reaction times to negative stimuli than those with lower anxiety. One interpretation is that moderate levels of emotional arousal associated with anxiety make individuals less susceptible to the distracting effects of negative stimuli.

9.
Gastroenterology ; 163(3): 742-753.e4, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35643172

RESUMO

BACKGROUND & AIMS: Several U.S. organizations now recommend starting average-risk colorectal cancer screening at age 45 years, but the prevalence of colonic neoplasia in individuals younger than 50 years has not been well characterized. We used a national endoscopic registry to calculate age-stratified prevalence and predictors of colorectal neoplasia. METHODS: Outpatient screening colonoscopies performed during 2010-2020 in the GI Quality Improvement Consortium registry were analyzed. We measured the prevalence of advanced neoplasia and adenomas by age, sex, and race/ethnicity, as well as the prevalence ratio of neoplasia compared with the reference group of 50- to 54-year-olds. Multivariable logistic regression models were used to identify predictors of neoplasia. RESULTS: We identified 3,928,727 screening colonoscopies, of which 129,736 (3.3%) were performed on average-risk individuals younger than 50 years. The prevalence of advanced neoplasia was 6.2% for 50- to 54-year-olds and 5.0% (prevalence ratio, 0.81; 95% confidence interval, 0.78-0.83) for average-risk 45- to 49-year-olds. Men had higher prevalence of neoplasia than women for all age groups. White individuals had higher prevalence of advanced neoplasia than persons of other racial/ethnic groups in most age groups, which was partially driven by serrated lesions. On multivariable regression, White individuals had higher odds of advanced neoplasia than Black, Hispanic, and Asian individuals in both younger and older age groups. CONCLUSIONS: In a large U.S. endoscopy registry, the prevalence of advanced neoplasia in 45- to 49-year-olds was substantial and supports beginning screening at age 45 years. White individuals had higher risk of advanced neoplasia than Black, Hispanic, and Asian individuals across the age spectrum. These findings may inform adenoma detection benchmarks and risk-based screening strategies.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Adenoma/diagnóstico , Adenoma/epidemiologia , Adenoma/patologia , Adulto , Idoso , Pólipos do Colo/patologia , Colonoscopia , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/epidemiologia , Neoplasias Colorretais/patologia , Detecção Precoce de Câncer , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Sistema de Registros , Fatores de Risco
10.
Am J Gastroenterol ; 118(5): 900-904, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36623168

RESUMO

INTRODUCTION: Variability in adherence rates to the Seattle protocol and to surveillance interval recommendations, established quality indicators (QIs) in Barrett's esophagus (BE), is unknown. METHODS: We evaluated endoscopist and site-based adherence rates to these QIs from January 2018 to May 2021 using the GI Quality Improvement Consortium national registry with matched endoscopy and pathology data. RESULTS: Across 153 practices with 572 endoscopists performing 20,155 endoscopies, adherence to the Seattle protocol varied by endoscopists (median 93.8%, IQR 18.9%) and by site (median 90.0%, IQR 20.1%). Adherence to appropriate surveillance intervals for nondysplastic BE also varied by endoscopist (median 82.4%, IQR 36.3%) and site (median 77.2%, IQR 29.8%). The overall dysplasia detection rate was 3.1% and varied among endoscopists and sites. DISCUSSION: These US population-based results can serve as a benchmark for quality initiatives and intervention trials aimed at improving outcomes for patients with BE.


Assuntos
Esôfago de Barrett , Neoplasias Esofágicas , Humanos , Esôfago de Barrett/diagnóstico , Esôfago de Barrett/patologia , Benchmarking , Esofagoscopia , Hiperplasia , Sistema de Registros , Neoplasias Esofágicas/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA