Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 133
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Acc Chem Res ; 57(9): 1372-1383, 2024 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-38590049

RESUMO

The COVID-19 pandemic further demonstrated the need for usable, reliable, and cost-effective point-of-care diagnostics that can be broadly deployed, ideally for self-testing at home. Antigen tests using more-detectable reporter labels (usually at the cost of reader complexity) achieve better diagnostic sensitivity, supporting the value of higher-analytical-sensitivity reporter technologies in lateral flow.We developed a new approach to simple, inexpensive lateral flow assays (LFAs) of great sensitivity, based on the glow stick peroxyoxalate chemistry widely used in emergency settings and in children's toys. At the peak of the COVID-19 pandemic, we had the opportunity to participate in the pandemic-driven NIH Rapid Acceleration of Diagnostics (RADx) initiative aiming to develop a deployable lateral flow diagnostic for SARS-CoV-2 nucleoprotein based on our novel glow stick-inspired light-emitting reporter technology. During this project, we screened more than 250 antibody pairs for analytical sensitivity and specificity directly in LFA format, using recombinant nucleoprotein and then gamma-irradiated virions spiked into negative nasal swab extracts. Membranes and other LFA materials and swabs and extraction reagent components also were screened and selected. Optimization of conjugate preparation and spraying as well as pretreatment/conditioning of the sample pad led to the final optimized LFA strip. Technology development also included optimization of excitation liquid enclosed in disposable droppers, design of a custom cartridge and smartphone-based reader, and app development, even a prototype reader usable with any mobile phone. Excellent preclinical performance was first demonstrated with contrived samples and then with leftover clinical samples. Moving beyond traditional academic focus areas, we were able to establish a quality management system (QMS), produce large numbers of customized LFA cassettes by contract injection molding, build in-house facilities to assemble and store thousands of complete tests for verification and validation and usability studies, and source kitting/packaging services and quality standard reagents and build partnerships for clinical translation, regulatory guidance, scale up, and market deployment. We were not able to bring this early stage technology to the point of commercialization within the limited time and resources available, but we did achieve strong proof-of-concept and advance translational aspects of the platform including initial high-performance LFAs, reading by the iPhone app using only a $2 plastic dark box with no lens, and convenient, usable excitation liquid packaging in droppers manufacturable in very large numbers.In this Account, we aim to provide a concise overview of our 18-month sprint toward the practical development of a deployable antigen lateral flow assay under pandemic conditions and the challenges and successes experienced by our team. We highlight what it takes to coach a technically savvy but commercially inexperienced academic team through the accelerated translation of an early stage technology into a useful product. Finally, we provide a guided tutorial and workflow to empower others interested in the rapid development of translatable LFAs.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , COVID-19/virologia , Humanos , SARS-CoV-2/isolamento & purificação , Testes Imediatos , Teste Sorológico para COVID-19/métodos , Fosfoproteínas/análise , Fosfoproteínas/metabolismo , Proteínas do Nucleocapsídeo de Coronavírus/análise , Teste para COVID-19/métodos
2.
Analyst ; 149(5): 1665, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38348476

RESUMO

Correction for 'Smartphone-read phage lateral flow assay for point-of-care detection of infection' by Maede Chabi, et al., Analyst, 2023, 148, 839-848, https://doi.org/10.1039/D2AN01499H.

3.
Anal Biochem ; 660: 114929, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36270332

RESUMO

Detection and quantification of antibodies, especially immunoglobulin G (IgG), is a cornerstone of ELISAs, many diagnostics, and the development of antibody-based drugs. Current state-of-the-art immunoassay techniques for antibody detection require species-specific secondary antibodies and carefully-controlled bioconjugations. Poor conjugation efficiency degrades assay performance and increases the risk of clinical false positives due to non-specific binding. We developed a generic, highly-sensitive platform for IgG quantification by fusing the IgG-Fc binding Z domain of Staphylococcal Protein A with the ultrabright bioluminescence reporter Nanoluc-luciferase (Nluc). We demonstrated the application of this fusion protein in a sandwich IgG detection immunoassay using surface-bound antigens to capture target IgG and protein A-Nanoluc fusion as the detector. We optimized the platform's sensitivity by incorporating multiple repeats of the Z domain into the fusion protein constructs. Using rabbit and mouse anti-SARS-CoV-2 Nucleoprotein IgGs as model analytes, we performed ELISAs in two different formats, either with SARS-CoV-2 Nucleoprotein as the capture antigen or with polyclonal chicken IgY as the capture antibody. Using standard laboratory equipment, the platform enabled the quantitation of antibody analytes at concentrations as low as 10 pg/mL (67 fM).


Assuntos
COVID-19 , Imunoglobulina G , Camundongos , Coelhos , Animais , Proteína Estafilocócica A , SARS-CoV-2 , Anticorpos Antivirais , Imunoensaio/métodos , Nucleoproteínas , Sensibilidade e Especificidade
4.
Biotechnol Bioeng ; 120(2): 482-490, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36225160

RESUMO

In the manufacture of therapeutic monoclonal antibodies, the clarified cell culture fluid (CCF) is typically loaded onto an initial protein A affinity capture column. Imperfect mass transfer and loading to maximum capacity can risk antibody breakthrough and loss of valuable product, but conservative underloading wastes expensive protein A resin. In addition, the effects of column fouling and ligand degradation require the frequent optimization of immunoglobulin G (IgG) loading to avoid wastage. Continuous real-time monitoring of IgG flowthrough is of great interest, therefore. We previously developed a fluorescence-based monitoring technology that allows batch mix-and-read mAb detection in the CCF. Here, we report the use of reporters immobilized on cyanogenbromide-activated Sepharose 4B resin for continuous detection of IgG in column breakthrough. The column effluent is continuously contacted with immobilized fluorescein-labeled Fc-binding ligands in a small monitoring column to produce an immediately-detectable change in fluorescence intensity. The technology allows rapid and reliable monitoring of IgG in a flowing stream of clarified CCF emerging from a protein A column, without prior sample preparation. We observed a significant change in fluorescence intensity at 0.5 g/L human IgG, sufficient to detect a 5% breakthrough of a 10 g/L load, within 18 s at a flow rate of 0.5 ml/min. The current small-scale technology is suitable for use in process development, but the chemistry should be readily adaptable to larger scale applications using fiber-optic sensors, and continuous IgG monitoring could be applicable in a variety of upstream and downstream process settings.


Assuntos
Anticorpos Monoclonais , Imunoglobulina G , Humanos , Cromatografia de Afinidade , Proteína Estafilocócica A , Ligantes , Corantes
5.
Crit Rev Food Sci Nutr ; : 1-23, 2023 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-37350754

RESUMO

The detrimental impact of foodborne pathogens on human health makes food safety a major concern at all levels of production. Conventional methods to detect foodborne pathogens, such as live culture, high-performance liquid chromatography, and molecular techniques, are relatively tedious, time-consuming, laborious, and expensive, which hinders their use for on-site applications. Recurrent outbreaks of foodborne illness have heightened the demand for rapid and simple technologies for detection of foodborne pathogens. Recently, Lateral flow assays (LFA) have drawn attention because of their ability to detect pathogens rapidly, cheaply, and on-site. Here, we reviewed the latest developments in LFAs to detect various foodborne pathogens in food samples, giving special attention to how reporters and labels have improved LFA performance. We also discussed different approaches to improve LFA sensitivity and specificity. Most importantly, due to the lack of studies on LFAs for the detection of viral foodborne pathogens in food samples, we summarized our recent research on developing LFAs for the detection of viral foodborne pathogens. Finally, we highlighted the main challenges for further development of LFA platforms. In summary, with continuing improvements, LFAs may soon offer excellent performance at point-of-care that is competitive with laboratory techniques while retaining a rapid format.

6.
Analyst ; 148(22): 5582-5587, 2023 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-37819257

RESUMO

Glow enzyme-linked immunosorbent assay (glow ELISA) uses inexpensive and shelf-stable glow stick reagents to chemically excite fluorescent reporters, obviating the need for excitation light sources, filters, and complex optics. It achieves excellent limits of detection while offering portability and equipment cost comparable to lateral flow immunoassays.


Assuntos
Indicadores e Reagentes , Ensaio de Imunoadsorção Enzimática , Imunoensaio
7.
Analyst ; 148(4): 839-848, 2023 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-36645184

RESUMO

The COVID-19 pandemic has highlighted the urgent need for sensitive, affordable, and widely accessible testing at the point of care. Here we demonstrate a new, universal LFA platform technology using M13 phage conjugated with antibodies and HRP enzymes that offers high analytical sensitivity and excellent performance in a complex clinical matrix. We also report its complete integration into a sensitive chemiluminescence-based smartphone-readable lateral flow assay for the detection of SARS-CoV-2 nucleoprotein. We screened 84 anti-nucleoprotein monoclonal antibody pairs in phage LFA and identified an antibody pair that gave an LoD of 25 pg mL-1 nucleoprotein in nasal swab extract using a FluorChem gel documentation system and 100 pg mL-1 when the test was imaged and analyzed by an in-house-developed smartphone reader. The smartphone-read LFA signals for positive clinical samples tested (N = 15, with known Ct) were statistically different (p < 0.001) from signals for negative clinical samples (N = 11). The phage LFA technology combined with smartphone chemiluminescence imaging can enable the timely development of ultrasensitive, affordable point-of-care testing platforms for SARS-CoV-2 and beyond.


Assuntos
Bacteriófagos , COVID-19 , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , COVID-19/diagnóstico , SARS-CoV-2 , Smartphone , Pandemias , Anticorpos , Testes Imediatos , Sensibilidade e Especificidade
8.
Luminescence ; 38(3): 341-349, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36760184

RESUMO

Chemiluminescence (CL) reactions are widely used for the detection and quantification of many types of analytes. Laccase has previously been proposed in CL reactions; however, its light emission behaviour has not been characterized. This study was conducted to characterize the laccase-luminol system, determine its kinetic parameters, and analyze the effects of protein and OH- concentration on the CL signal. Laccase from Coriolopsis gallica was combined with different concentrations of luminol (125 nM to 4 mM), and the enzyme kinetics were evaluated using diverse kinetic models. The laccase-luminol system was able to produce CL without an intermediate molecule, but it exhibited substrate-inhibition behaviour. A two-site random model was used and suggested that when the first luminol molecule was bound to the active site, laccase affinity for the second luminol molecule was increased. This inhibition effect could be avoided using a low luminol concentration. At 5 µM luminol concentration, 1 mg/ml (0.13 U) laccase is needed to achieve nearly 90% of the maximum CL signal, suggesting that the available luminol could not bind to all active sites. Furthermore, the concentration of NaOH negatively affected the CL signal. The laccase-luminol system represents an alternative to existing CL systems, with potential uses in molecular detection and quantification.


Assuntos
Lacase , Luminol , Luminol/química , Lacase/química , Luminescência , Medições Luminescentes
9.
Int J Mol Sci ; 24(2)2023 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-36674796

RESUMO

Staphylococcus aureus protein A (SpA) is an IgG Fc-binding virulence factor that is widely used in antibody purification and as a scaffold to develop affinity molecules. A cyclized SpA Z domain could offer exopeptidase resistance, reduced chromatographic ligand leaching after single-site endopeptidase cleavage, and enhanced IgG binding properties by preorganization, potentially reducing conformational entropy loss upon binding. In this work, a Z domain trimer (Z3) was cyclized using protein intein splicing. Interactions of cyclic and linear Z3 with human IgG1 were characterized by differential scanning fluorimetry (DSF), surface plasmon resonance (SPR), and isothermal titration calorimetry (ITC). DSF showed a 5 ℃ increase in IgG1 melting temperature when bound by each Z3 variant. SPR showed the dissociation constants of linear and cyclized Z3 with IgG1 to be 2.9 nM and 3.3 nM, respectively. ITC gave association enthalpies for linear and cyclic Z3 with IgG1 of -33.0 kcal/mol and -32.7 kcal/mol, and -T∆S of association 21.2 kcal/mol and 21.6 kcal/mol, respectively. The compact cyclic Z3 protein contains 2 functional binding sites and exhibits carboxypeptidase Y-resistance. The results suggest cyclization as a potential approach toward more stable SpA-based affinity ligands, and this analysis may advance our understanding of protein engineering for ligand and drug development.


Assuntos
Inteínas , Staphylococcus aureus , Humanos , Inteínas/genética , Ligantes , Termodinâmica , Imunoglobulina G , Calorimetria/métodos , Ligação Proteica
10.
Curr Diab Rep ; 22(3): 95-115, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35267140

RESUMO

PURPOSE OF REVIEW: Diabetes mellitus is a complex, chronic illness characterized by elevated blood glucose levels that occurs when there is cellular resistance to insulin action, pancreatic ß-cells do not produce sufficient insulin, or both. Diabetes prevalence has greatly increased in recent decades; consequently, it is considered one of the fastest-growing public health emergencies globally. Poor blood glucose control can result in long-term micro- and macrovascular complications such as nephropathy, retinopathy, neuropathy, and cardiovascular disease. Individuals with diabetes require continuous medical care, including pharmacological intervention as well as lifestyle and dietary changes. RECENT FINDINGS: The most common form of diabetes mellitus, type 2 diabetes (T2DM), represents approximately 90% of all cases worldwide. T2DM occurs more often in middle-aged and elderly adults, and its cause is multifactorial. However, its incidence has increased in children and young adults due to obesity, sedentary lifestyle, and inadequate nutrition. This high incidence is also accompanied by an estimated underdiagnosis prevalence of more than 50% worldwide. Implementing successful and cost-effective strategies for systematic screening of diabetes mellitus is imperative to ensure early detection, lowering patients' risk of developing life-threatening disease complications. Therefore, identifying new biomarkers and assay methods for diabetes mellitus to develop robust, non-invasive, painless, highly-sensitive, and precise screening techniques is essential. This review focuses on the recent development of new clinically validated and novel biomarkers as well as the methods for their determination that represent cost-effective alternatives for screening and early diagnosis of T2DM.


Assuntos
Doenças Cardiovasculares , Diabetes Mellitus Tipo 2 , Idoso , Biomarcadores , Criança , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/epidemiologia , Humanos , Hipoglicemiantes , Insulina , Pessoa de Meia-Idade
11.
Analyst ; 146(15): 4835-4840, 2021 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-34198311

RESUMO

We introduce analyte-dependent exclusion of reporter reagents from restricted-access adsorbents as the basis of an isocratic reporter-exclusion immunoassay for viruses, proteins, and other analytes. Capto™ Core 700 and related resins possess a noninteracting size-selective outer layer surrounding a high-capacity nonspecific mixed-mode capture adsorbent core. In the absence of analyte, antibody-enzyme reporter conjugates can enter the adsorbent and be captured, and their signal is lost. In the presence of large or artificially-expanded analytes, reporter reagents bind to analyte species to form complexes large enough to be excluded from the adsorbent core, allowing their signal to be observed. This assay principle is demonstrated using M13 bacteriophage virus and human chorionic gonadotropin as model analytes. The simple isocratic detection approach described here allows a rapid implementation of immunoassay for detection of a wide range of analytes and uses inexpensive, generally-applicable, and stable column materials instead of costly analyte-specific immunoaffinity adsorbents.


Assuntos
Bacteriófago M13 , Gonadotropina Coriônica , Humanos , Imunoensaio , Indicadores e Reagentes
12.
Angew Chem Int Ed Engl ; 60(18): 10273-10278, 2021 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-33684258

RESUMO

The receptor-binding domain (RBD) of the severe acute respiratory syndrome coronavirus 2 spike (S) protein plays a central role in mediating the first step of virus infection to cause disease: virus binding to angiotensin-converting enzyme 2 (ACE2) receptors on human host cells. Therefore, S/RBD is an ideal target for blocking and neutralization therapies to prevent and treat coronavirus disease 2019 (COVID-19). Using a target-based selection approach, we developed oligonucleotide aptamers containing a conserved sequence motif that specifically targets S/RBD. Synthetic aptamers had high binding affinity for S/RBD-coated virus mimics (KD ≈7 nM) and also blocked interaction of S/RBD with ACE2 receptors (IC50 ≈5 nM). Importantly, aptamers were able to neutralize S protein-expressing viral particles and prevent host cell infection, suggesting a promising COVID-19 therapy strategy.


Assuntos
Enzima de Conversão de Angiotensina 2/metabolismo , Antivirais/farmacologia , Aptâmeros de Nucleotídeos/farmacologia , Tratamento Farmacológico da COVID-19 , SARS-CoV-2/efeitos dos fármacos , Glicoproteína da Espícula de Coronavírus/metabolismo , Antivirais/química , Aptâmeros de Nucleotídeos/química , Sequência de Bases , COVID-19/metabolismo , Células HEK293 , Humanos , Domínios e Motivos de Interação entre Proteínas/efeitos dos fármacos , Mapas de Interação de Proteínas/efeitos dos fármacos , SARS-CoV-2/química , SARS-CoV-2/fisiologia , Glicoproteína da Espícula de Coronavírus/química
13.
Biotechnol Bioeng ; 117(7): 2100-2115, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32255523

RESUMO

Biopharmaceutical product and process development do not yet take advantage of predictive computational modeling to nearly the degree seen in industries based on smaller molecules. To assess and advance progress in this area, spirited coopetition (mutually beneficial collaboration between competitors) was successfully used to motivate industrial scientists to develop, share, and compare data and methods which would normally have remained confidential. The first "Highland Games" competition was held in conjunction with the October 2018 Recovery of Biological Products Conference in Ashville, NC, with the goal of benchmarking and assessment of the ability to predict development-related properties of six antibodies from their amino acid sequences alone. Predictions included purification-influencing properties such as isoelectric point and protein A elution pH, and biophysical properties such as stability and viscosity at very high concentrations. Essential contributions were made by a large variety of individuals, including companies which consented to provide antibody amino acid sequences and test materials, volunteers who undertook the preparation and experimental characterization of these materials, and prediction teams who attempted to predict antibody properties from sequence alone. Best practices were identified and shared, and areas in which the community excels at making predictions were identified, as well as areas presenting opportunities for considerable improvement. Predictions of isoelectric point and protein A elution pH were especially good with all-prediction average errors of 0.2 and 1.6 pH unit, respectively, while predictions of some other properties were notably less good. This manuscript presents the events, methods, and results of the competition, and can serve as a tutorial and as a reference for in-house benchmarking by others. Organizations vary in their policies concerning disclosure of methods, but most managements were very cooperative with the Highland Games exercise, and considerable insight into common and best practices is available from the contributed methods. The accumulated data set will serve as a benchmarking tool for further development of in silico prediction tools.


Assuntos
Anticorpos Monoclonais/química , Produtos Biológicos/química , Descoberta de Drogas/métodos , Sequência de Aminoácidos , Humanos , Rituximab/química
14.
Analyst ; 145(14): 4942-4949, 2020 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-32500871

RESUMO

We have developed an immuno-PCR based diagnostic platform which couples detection antibodies to self-assembled, ultra-detectable DNA-avidin nanoparticles stabilized with poly(ethylene glycol) to link DNA amplification to target protein concentration. Electrostatic neutralization and cloaking of the PCR-amplifiable DNA labels by avidin and PEG coating reduces non-specific "stickiness" and enhances assay sensitivity. We further optimized the detectability of the nanoparticles by incorporating four repeats of a unique synthetic DNA PCR target into each nanoparticle. Using human chorionic gonadotropin hormone (hCG) as a model analyte, this platform was able to quantitate the target hCG protein in femtomolar concentrations using only standard laboratory equipment.


Assuntos
Avidina , Nanopartículas , Anticorpos , DNA/genética , Humanos , Reação em Cadeia da Polimerase
15.
Proc Natl Acad Sci U S A ; 113(28): 7711-6, 2016 07 12.
Artigo em Inglês | MEDLINE | ID: mdl-27354529

RESUMO

The current simple nanofluid flooding method for tertiary or enhanced oil recovery is inefficient, especially when used with low nanoparticle concentration. We have designed and produced a nanofluid of graphene-based amphiphilic nanosheets that is very effective at low concentration. Our nanosheets spontaneously approached the oil-water interface and reduced the interfacial tension in a saline environment (4 wt % NaCl and 1 wt % CaCl2), regardless of the solid surface wettability. A climbing film appeared and grew at moderate hydrodynamic condition to encapsulate the oil phase. With strong hydrodynamic power input, a solid-like interfacial film formed and was able to return to its original form even after being seriously disturbed. The film rapidly separated oil and water phases for slug-like oil displacement. The unique behavior of our nanosheet nanofluid tripled the best performance of conventional nanofluid flooding methods under similar conditions.

16.
Sensors (Basel) ; 19(24)2019 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-31835468

RESUMO

This work presents a proof-of-concept demonstration of a novel inductive transducer, the femtoMag, that can be integrated with a lateral-flow assay (LFA) to provide detection and quantification of molecular biomarkers. The femtoMag transducer is manufactured using a low-cost printed circuit board (PCB) technology and can be controlled by relatively inexpensive electronics. It allows rapid high-precision quantification of the number (or amount) of superparamagnetic nanoparticle reporters along the length of an LFA test strip. It has a detection limit of 10-10 emu, which is equivalent to detecting 4 ng of superparamagnetic iron oxide (Fe3O4) nanoparticles. The femtoMag was used to quantify the hCG pregnancy hormone by quantifying the number of 200 nm magnetic reporters (superparamagnetic Fe3O4 nanoparticles embedded into a polymer matrix) immuno-captured within the test line of the LFA strip. A sensitivity of 100 pg/mL has been demonstrated. Upon further design and control electronics improvements, the sensitivity is projected to be better than 10 pg/mL. Analysis suggests that an average of 109 hCG molecules are needed to specifically bind 107 nanoparticles in the test line. The ratio of the number of hCG molecules in the sample to the number of reporters in the test line increases monotonically from 20 to 500 as the hCG concentration increases from 0.1 ng/mL to 10 ng/mL. The low-cost easy-to-use femtoMag platform offers high-sensitivity/high-precision target analyte quantification and promises to bring state-of-the-art medical diagnostic tests to the point of care.

17.
Langmuir ; 34(12): 3694-3700, 2018 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-29509429

RESUMO

Maintaining colloidal stability in unfriendly environments while retaining surface chemical properties is challenging for fundamental science and crucial for many applications. Here, we report for the first time that by using a low concentration of poly(sodium 4-styrenesulfonate) (PSS), graphene-based amphiphilic Janus nanosheets (AJNs) can be stabilized in high salt brine (3 wt % NaCl and 0.5 wt % CaCl2), whereas the interfacial behavior of the nanosheets is not affected. The adsorption of PSS on the hydrophilic and hydrophobic surfaces of AJNs in brine was investigated experimentally and by molecular dynamics simulations. Simulations further showed that the spatial configuration of absorbed PSS molecules with sulfonate functional groups facing outward favored the generation of electrosteric repulsive interactions. Calculations of the interaction energy between PSS molecules and the nanosheet revealed surface charge as a key parameter to stabilize AJNs in the salt environment, as demonstrated by the case of graphene oxide with higher surface charge. Simulations were also used to examine the interfacial behavior of graphene-based AJNs in biphasic systems. The AJNs, which exhibited asymmetry in surface wettability, remained at the oil/brine interface because of PSS detachment from the hydrophobic surface. The results were subsequently experimentally confirmed, consistent with our previously reported graphene-based AJN fluid prepared in fresh water. The process was thermodynamically supported by the demonstrated negative change of Gibbs free energy. We believe that such a strategy could benefit for the stabilization of other AJNs with surface chemical accessibility under harsh conditions.

18.
Biochim Biophys Acta ; 1864(1): 154-64, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26307469

RESUMO

BACKGROUND: The IgE-binding DNA aptamer 17.4 is known to inhibit the interaction of IgE with the high-affinity IgE Fc receptor FcεRI. While this and other aptamers have been widely used and studied, there has been relatively little investigation of the kinetics and energetics of their interactions with their targets, by either single-molecule or ensemble methods. METHODS: The dissociation kinetics of the D17.4/IgE complex and the effects of temperature and ionic strength were studied using fluorescence anisotropy and single-molecule spectroscopy, and activation parameters calculated. RESULTS: The dissociation of D17.4/IgE complex showed a strong dependence on temperature and salt concentration. The koff of D17.4/IgE complex was calculated to be (2.92±0.18)×10(-3) s(-1) at 50 mM NaCl, and (1.44±0.02)×10(-2) s(-1) at 300 mM NaCl, both in 1 mM MgCl2 and 25°C. The dissociation activation energy for the D17.4/IgE complex, Ea, was 16.0±1.9 kcal mol(-1) at 50 mM NaCl and 1 mM MgCl2. Interestingly, we found that the C19A mutant of D17.4 with stabilized stem structure showed slower dissociation kinetics compared to D17.4. Single-molecule observations of surface-immobilized D17.4/IgE showed much faster dissociation kinetics, and heterogeneity not observable by ensemble techniques. CONCLUSIONS: The increasing koff value with increasing salt concentration is attributed to the electrostatic interactions between D17.4/IgE. We found that both the changes in activation enthalpy and activation entropy are insignificant with increasing NaCl concentration. The slower dissociation of the mutant C19A/IgE complex is likely due to the enhanced stability of the aptamer. GENERAL SIGNIFICANCE: The activation parameters obtained by applying transition state analysis to kinetic data can provide details on mechanisms of molecular recognition and have applications in drug design. Single-molecule dissociation kinetics showed greater kinetic complexity than was observed in the ensemble in-solution systems, potentially reflecting conformational heterogeneity of the aptamer. This article is part of a Special Issue entitled: Physiological Enzymology and Protein Functions.


Assuntos
Aptâmeros de Nucleotídeos/química , Imunoglobulina E/química , Conformação de Ácido Nucleico , Termodinâmica , Algoritmos , Aptâmeros de Nucleotídeos/genética , Aptâmeros de Nucleotídeos/metabolismo , Sequência de Bases , Fenômenos Biofísicos , Polarização de Fluorescência/instrumentação , Polarização de Fluorescência/métodos , Imunoglobulina E/metabolismo , Cinética , Microscopia de Fluorescência , Modelos Químicos , Modelos Moleculares , Mutação , Ligação Proteica/efeitos dos fármacos , Cloreto de Sódio/química , Cloreto de Sódio/metabolismo , Cloreto de Sódio/farmacologia , Temperatura
19.
Analyst ; 142(17): 3127-3131, 2017 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-28744542

RESUMO

We use single molecule spectroscopy to study a multicomponent, competitive protein adsorption system. Fluorescently-labeled α-lactalbumin proteins are super-resolved adsorbing to cationic anion-exchange ligands in the presence of a competitor, insulin. We find that the competitor reduces the number of binding events by blocking ligands throughout the observed measurement time while the single-site adsorption kinetics are unchanged.


Assuntos
Ânions , Lactalbumina/análise , Análise Espectral , Adsorção , Fluorescência , Cinética , Ligantes
20.
Proc Natl Acad Sci U S A ; 111(6): 2075-80, 2014 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-24459184

RESUMO

Chromatographic protein separations, immunoassays, and biosensing all typically involve the adsorption of proteins to surfaces decorated with charged, hydrophobic, or affinity ligands. Despite increasingly widespread use throughout the pharmaceutical industry, mechanistic detail about the interactions of proteins with individual chromatographic adsorbent sites is available only via inference from ensemble measurements such as binding isotherms, calorimetry, and chromatography. In this work, we present the direct superresolution mapping and kinetic characterization of functional sites on ion-exchange ligands based on agarose, a support matrix routinely used in protein chromatography. By quantifying the interactions of single proteins with individual charged ligands, we demonstrate that clusters of charges are necessary to create detectable adsorption sites and that even chemically identical ligands create adsorption sites of varying kinetic properties that depend on steric availability at the interface. Additionally, we relate experimental results to the stochastic theory of chromatography. Simulated elution profiles calculated from the molecular-scale data suggest that, if it were possible to engineer uniform optimal interactions into ion-exchange systems, separation efficiencies could be improved by as much as a factor of five by deliberately exploiting clustered interactions that currently dominate the ion-exchange process only accidentally.


Assuntos
Cromatografia por Troca Iônica/métodos , Proteínas/isolamento & purificação , Processos Estocásticos , Adsorção , Cinética , Lactalbumina/química , Limite de Detecção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA