1.
Int J Mol Sci ; 23(19)2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36232937

RESUMO

Implantable glucose biosensors provide real-time information about blood glucose fluctuations, but their utility and accuracy are time-limited due to the foreign body response (FBR) following their insertion beneath the skin. The slow release of nitric oxide (NO), a gasotransmitter with inflammation regulatory properties, from a sensor surface has been shown to dramatically improve sensors' analytical biocompatibility by reducing the overall FBR response. Indeed, work in a porcine model suggests that as long as the implants (sensors) continue to release NO, even at low levels, the inflammatory cell infiltration and resulting collagen density are lessened. While these studies strongly support the benefits of NO release in mitigating the FBR, the mechanisms through which exogenous NO acts on the surrounding tissue, especially under the condition of hyperglycemia, remain vague. Such knowledge would inform strategies to refine appropriate NO dosage and release kinetics for optimal therapeutic activity. In this study, we evaluated mediator, immune cell, and mRNA expression profiles in the local tissue microenvironment surrounding implanted sensors as a function of NO release, diabetes, and implantation duration. A custom porcine wound healing-centric multiplex gene array was developed for nanoString barcoding analysis. Tissues adjacent to sensors with sustained NO release abrogated the implant-induced acute and chronic FBR through modulation of the tissue-specific immune chemokine and cytokine microenvironment, resulting in decreased cellular recruitment, proliferation, and activation at both the acute (7-d) and chronic (14-d) phases of the FBR. Further, we found that sustained NO release abrogated the implant-induced acute and chronic foreign body response through modulation of mRNA encoding for key immunological signaling molecules and pathways, including STAT1 and multiple STAT1 targets including MAPK14, IRAK4, MMP2, and CXCL10. The condition of diabetes promoted a more robust FBR to the implants, which was also controlled by sustained NO release.


Assuntos
Corpos Estranhos , Gasotransmissores , Proteína Quinase 14 Ativada por Mitógeno , Animais , Glicemia/análise , Colágeno/metabolismo , Citocinas , Reação a Corpo Estranho , Glucose , Quinases Associadas a Receptores de Interleucina-1 , Metaloproteinase 2 da Matriz , Óxido Nítrico/metabolismo , RNA Mensageiro , Suínos
2.
ACS Sens ; 4(12): 3257-3264, 2019 12 27.
Artigo em Inglês | MEDLINE | ID: mdl-31793767

RESUMO

Analytical performance and tissue interactions of nitric oxide (NO)-releasing continuous glucose sensors were evaluated over a 28 d study in a diabetic swine model. Interstitial glucose was detected using an implanted needle-type amperometric glucose sensor. Two NO-release durations from the sensor surface were achieved by doping the membranes with nonporous (14 d release) or porous (30 d release) S-nitrosothiol-functionalized silica nanoparticles. Numerical and clinical accuracy of the sensors were assessed at time points (1, 7, 14, 21, and 28 d) following implantation. Nitric oxide-releasing sensors demonstrated accurate glucose detection over a time period directly correlated with the active release of NO. Silica particle-doped sensors that released NO for 30 d showed standard-compliant accuracy (i.e., mean absolute relative difference ≤ 15%) for >3 weeks post-implantation. Histological staining for inflammatory biomarkers suggested that the observed performance improvement was the result of decreased inflammatory cell count and a lower density collagen capsule.


Assuntos
Glucose/análise , Inflamação/prevenção & controle , Doadores de Óxido Nítrico/farmacologia , Óxido Nítrico/metabolismo , Animais , Técnicas Biossensoriais/métodos , Colágeno/metabolismo , Diabetes Mellitus Experimental/metabolismo , Feminino , Masculino , Nanopartículas/química , Doadores de Óxido Nítrico/química , S-Nitrosotióis/química , S-Nitrosotióis/farmacologia , Dióxido de Silício/química , Suínos
3.
Artigo em Inglês | MEDLINE | ID: mdl-30106723

RESUMO

The kidney is an anisotropic organ, with higher elasticity along versus across nephrons. The degree of mechanical anisotropy in the kidney may be diagnostically relevant if properly exploited; however, if improperly controlled, anisotropy may confound stiffness measurements. The purpose of this study is to demonstrate the clinical feasibility of acoustic radiation force (ARF)-induced peak displacement (PD) measures for both exploiting and obviating mechanical anisotropy in the cortex of human kidney allografts, in vivo. Validation of the imaging methods is provided by preclinical studies in pig kidneys, in which ARF-induced PD values were significantly higher ( , Wilcoxon) when the transducer executing asymmetric ARF was oriented across versus along the nephrons. The ratio of these PD values obtained with the transducer oriented across versus along the nephrons strongly linearly correlated ( R2 = 0.95 ) to the ratio of shear moduli measured by shear wave elasticity imaging. On the contrary, when a symmetric ARF was implemented, no significant difference in PD was observed ( p > 0.01 ). Similar results were demonstrated in vivo in the kidney allografts of 14 patients. The symmetric ARF produced PD measures with no significant difference ( p > 0.01 ) between along versus across alignments, but the asymmetric ARF yielded PD ratios that remained constant over a six-month observation period post-transplantation, consistent with stable serum creatinine level and urine protein-to-creatinine ratio in the same patient population ( p > 0.01 ). The results of this pilot in vivo clinical study suggest the feasibility of 1) implementing symmetrical ARF to obviate mechanical anisotropy in the kidney cortex when anisotropy is a confounding factor and 2) implementing asymmetric ARF to exploit mechanical anisotropy when mechanical anisotropy is a potentially relevant biomarker.


Assuntos
Aloenxertos , Técnicas de Imagem por Elasticidade/métodos , Córtex Renal , Transplante de Rim , Adulto , Idoso , Aloenxertos/diagnóstico por imagem , Aloenxertos/fisiologia , Animais , Anisotropia , Módulo de Elasticidade/fisiologia , Feminino , Humanos , Córtex Renal/diagnóstico por imagem , Córtex Renal/fisiologia , Masculino , Pessoa de Meia-Idade , Insuficiência Renal Crônica/diagnóstico por imagem , Insuficiência Renal Crônica/cirurgia , Suínos