Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 279
Filtrar
1.
Optom Vis Sci ; 101(1): 12-24, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38350054

RESUMO

ABSTRACT: Detailed clinical assessment is critical to allow sensitive evaluation of the eye and its management. As technology advances, these assessment techniques can be adapted and refined to improve the detection of pathological changes of ocular tissue and their impact on visual function. Enhancements in optical medical devices including spectacle, contact, and intraocular lenses have allowed for a better understanding of the mechanism and amelioration of presbyopia and myopia control. Advancements in imaging technology have enabled improved quantification of the tear film and ocular surface, informing diagnosis and treatment strategies. Miniaturized electronics, large processing power, and in-built sensors in smartphones and tablets capacitate more portable assessment tools for clinicians, facilitate self-monitoring and treatment compliance, and aid communication with patients. This article gives an overview of how technology has been used in many areas of eye care to improve assessments and treatment and provides a snapshot of some of my studies validating and using technology to inform better evidence-based patient management.


Assuntos
Distinções e Prêmios , Lentes Intraoculares , Presbiopia , Procedimentos Cirúrgicos Refrativos , Humanos , Visão Ocular
2.
Optom Vis Sci ; 101(1): 37-43, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38350056

RESUMO

SIGNIFICANCE: Popularity of publicly searched myopia terminologies is reported, for example, myopia control over myopia management and myopia over nearsighted or shortsighted. Insights are also provided for searches on specific myopia control interventions. The findings offer an evidence-based starting point for public messaging and communications by clinicians, policymakers, and other industry leaders. PURPOSE: Public understanding of myopia can be difficult to ascertain for clinicians. Although small-scale studies provide valuable snapshots of data, findings tend to be population-specific and thus difficult to extrapolate to global audiences. In this study, big data were used to provide a more comprehensive depiction of global market interest in myopia. METHODS: Google Trends data were used to analyze searches relating to myopia between January 2004 and August 2023. Data extracted were related to use of the terms myopia control and myopia management, with further searches executed for common myopia control interventions: orthokeratology, contact lenses, atropine, and glasses. Analysis into the search interest of other refractive error states, hyperopia and astigmatism, was also undertaken along with alternative terms that may be used to describe myopia. Where relevant, search trends were considered worldwide, by country, and over time. RESULTS: Myopia was a more popular search term than common layman alternatives such as nearsighted or shortsighted. Myopia control was found to be more popular than myopia management, and of the specific myopia interventions, atropine was most popular. Compared with astigmatism and hyperopia, relative search volumes were greatest for myopia, on average accounting for approximately 50% of the relative search volume at the country level. CONCLUSIONS: The differences identified in both popularity of myopia-related search terms and specific interventions may provide the basis for improvements in public messaging and facilitate patient-practitioner communication.


Assuntos
Astigmatismo , Hiperopia , Miopia , Humanos , Big Data , Miopia/epidemiologia , Miopia/terapia , Atropina
3.
Optom Vis Sci ; 2024 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-39177531

RESUMO

SIGNIFICANCE: When using lissamine green for bulbar conjunctival evaluation, the most staining was observed with two applications of the same strip in the same eye, wetted with a drop of saline. The first application was 5 seconds after wetting the strip, and the second was 1 minute later, followed by immediate viewing. This suggests that bulbar staining should be viewed before the lid wiper region. PURPOSE: This study aimed to optimize the assessment of lissamine green staining of the bulbar conjunctiva by investigating the application technique and subsequent observation period. METHODS: Twenty-two participants with dry eye (as defined by the Tear Film and Ocular Surface Society Dry Eye Workshop II) were recruited to trial five application methods in randomized order: (1) application immediately after wetting a single strip, (2) application 5 seconds after wetting a single strip, (3) application 10 seconds after wetting a single strip, (4) consecutive single application of sodium fluorescein followed by lissamine green 5 seconds after wetting, and (5) two applications using the same lissamine green strip 5 seconds after wetting, 1 minute apart. Slit-lamp photography of the conjunctiva was performed immediately following application and at 30, 60, 90, and 300 seconds after application. Three experienced (masked) practitioners independently quantified the visible punctate spots and graded the staining intensity within the images in a random order. RESULTS: Values for punctate spot count (F = 6.29, p<0.0001) and lissamine green staining intensity (F = 6.29, p<0.0001) varied significantly between the different application methods. Using two applications of the same lissamine green strip, 1 minute apart, in the same eye resulted in the greatest values for both punctate spot count and lissamine green staining intensity. Lissamine green staining decreased with time for both spot count (F = 18.87, p<0.0001) and lissamine green staining intensity (F = 11.33, p<0.0001), with the most staining found immediately after application followed by a gradual decline. There was no evidence of any interaction effect between time and application method for either measure (p>0.05 for both). CONCLUSIONS: The optimal approach for assessing bulbar conjunctival lissamine green staining involves two applications of a whole infused drop resting on the same strip for 5 seconds, applied 1 minute apart. The ocular surface should be viewed immediately after application to maximize the conjunctival staining observed.

4.
Ophthalmic Physiol Opt ; 44(3): 641-671, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38404172

RESUMO

PURPOSE: With the introduction of ChatGPT, artificial intelligence (AI)-based large language models (LLMs) are rapidly becoming popular within the scientific community. They use natural language processing to generate human-like responses to queries. However, the application of LLMs and comparison of the abilities among different LLMs with their human counterparts in ophthalmic care remain under-reported. RECENT FINDINGS: Hitherto, studies in eye care have demonstrated the utility of ChatGPT in generating patient information, clinical diagnosis and passing ophthalmology question-based examinations, among others. LLMs' performance (median accuracy, %) is influenced by factors such as the iteration, prompts utilised and the domain. Human expert (86%) demonstrated the highest proficiency in disease diagnosis, while ChatGPT-4 outperformed others in ophthalmology examinations (75.9%), symptom triaging (98%) and providing information and answering questions (84.6%). LLMs exhibited superior performance in general ophthalmology but reduced accuracy in ophthalmic subspecialties. Although AI-based LLMs like ChatGPT are deemed more efficient than their human counterparts, these AIs are constrained by their nonspecific and outdated training, no access to current knowledge, generation of plausible-sounding 'fake' responses or hallucinations, inability to process images, lack of critical literature analysis and ethical and copyright issues. A comprehensive evaluation of recently published studies is crucial to deepen understanding of LLMs and the potential of these AI-based LLMs. SUMMARY: Ophthalmic care professionals should undertake a conservative approach when using AI, as human judgement remains essential for clinical decision-making and monitoring the accuracy of information. This review identified the ophthalmic applications and potential usages which need further exploration. With the advancement of LLMs, setting standards for benchmarking and promoting best practices is crucial. Potential clinical deployment requires the evaluation of these LLMs to move away from artificial settings, delve into clinical trials and determine their usefulness in the real world.


Assuntos
Inteligência Artificial , Oftalmologia , Humanos , Tomada de Decisão Clínica , Olho , Julgamento
5.
Ophthalmic Physiol Opt ; 44(7): 1398-1406, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39225035

RESUMO

PURPOSE: To assess the visual impact of Diffusion Optics Technology™ 0.2 DOT lenses (SightGlass Vision Inc.) designed for myopia control on primary gaze. DOT spectacle lenses contain light scattering elements that scatter light as it passes through the lens which, in turn, reduces retinal image contrast. METHODS: Fifty-one children (12.2 ± 1.3, range 10-14 years; 51% females) were randomly assigned to wear DOT spectacle (n = 27) or single vision lenses (n = 24) across six investigational sites in North America. Binocular high- and low-contrast distant visual acuities, near visual acuity, reading speed, contrast sensitivity, stereoacuity and glare were assessed in primary gaze after at least 3 years of wear, with the study 95% powered in all metrics to detect significant differences between the groups. RESULTS: Mean binocular distance high-contrast (-0.09 ± 0.02 vs. -0.08 ± 0.02 logMAR, p = 0.81), low-contrast (0.05 ± 0.02 vs. 0.07 ± 0.02 logMAR, p = 0.52) and near visual acuity with glare sources (-0.06 ± 0.03 vs. -0.09 ± 0.03 logMAR, p = 0.32) were similar for DOT and single vision lens wearers, respectively. Contrast sensitivity was similar between children wearing DOT or single vision lenses across 11 of the 16 spatial frequencies (p > 0.05). Mean stereopsis was similar (p = 0.30) with the DOT lenses (33.2 ± 12.5″) and single vision lenses (38.1 ± 14.2″). Functional reading speed metrics were similar in both study groups, as was the objectively measured head tilt during reading (p > 0.05). The mean halo radius was 0.56° ± 0.17° with the DOT lenses compared with 0.50° ± 0.12° with single vision lenses (p = 0.02), but the statistically significant difference was smaller than the non-inferiority bound of 0.4°. CONCLUSION: Diffusion optics technology lenses provide a clinically equivalent visual experience to a standard single vision lens.


Assuntos
Sensibilidades de Contraste , Óculos , Miopia , Visão Binocular , Acuidade Visual , Humanos , Feminino , Masculino , Miopia/fisiopatologia , Miopia/terapia , Criança , Acuidade Visual/fisiologia , Adolescente , Visão Binocular/fisiologia , Sensibilidades de Contraste/fisiologia , Ofuscação , Refração Ocular/fisiologia , Percepção de Profundidade/fisiologia , Leitura , Desenho de Equipamento
6.
Ophthalmic Physiol Opt ; 44(7): 1368-1391, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39295273

RESUMO

INTRODUCTION: This work aimed to establish the largest UK and Ireland consensus on myopia management in children and young people (CYP). METHODS: A modified Delphi consensus was conducted with a panel of 34 optometrists and ophthalmologists with expertise in myopia management. RESULTS: Two rounds of voting took place and 131 statements were agreed, including that interventions should be discussed with parents/carers of all CYP who develop myopia before the age of 13 years, a recommendation for interventions to be publicly funded for those at risk of fast progression and high myopia, that intervention selection should take into account the CYP's hobbies and lifestyle and that additional training for eye care professionals should be available from non-commercial sources. Topics for which published evidence is limited or lacking were areas of weaker or no consensus. Modern myopia management contact and spectacles are suitable first-line treatments. The role and provision of low-concentration atropine needs to be reviewed once marketing authorisations and funding decisions are in place. There is some evidence that a combination of low-concentration atropine with an optical intervention can have an additive effect; further research is needed. Once an intervention is started, best practice is to monitor non-cycloplegic axial length 6 monthly. CONCLUSION: Research is needed to identify those at risk of progression, the long-term effectiveness of individual and combined interventions, and when to discontinue treatment when myopia has stabilised. As further evidence continues to emerge, this consensus work will be repeated to ensure it remains relevant.


Assuntos
Técnica Delphi , Miopia , Humanos , Miopia/terapia , Miopia/fisiopatologia , Miopia/diagnóstico , Criança , Irlanda , Reino Unido , Adolescente , Consenso , Gerenciamento Clínico , Óculos , Refração Ocular/fisiologia , Masculino , Feminino
7.
Medicina (Kaunas) ; 60(6)2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38929602

RESUMO

Background and Objectives: Dry Eye Disease (DED) is a chronic condition characterised by tear film instability and ocular surface disruption, significantly impacting patients' quality of life. This study aimed to provide top-level clinical evidence for the long-term efficacy of dehydrated amniotic membrane (dAM, Omnigen®) delivered via a specialised bandage contact lens (sBCL, OmniLenz) for managing moderate-to-severe DED. Materials and Methods: This randomised controlled trial (NCT04553432) involved 93 participants with moderate-to-severe DED, randomised to receive a 1-week bilateral treatment of either dAM (17 mm diameter with 6 mm central 'window') applied under a sBCL or sBCL alone. Participants were assessed at baseline and followed up at 1, 3, and 6 months post-treatment. Outcomes included changes in symptomatology, tear film and ocular surface measurements, and in vivo confocal microscopy imaging of corneal nerve parameters and corneal dendritic cell (CDC) counts. Results: The dAM-sBCL group demonstrated a 65% reduction in OSDI scores at 6 months (p < 0.001), with 88% of participants showing improvement at 1 month. Corneal staining was significantly reduced in both groups. dAM-sBCL provided significant improvements in corneal nerve parameters at 1 month, with sustained positive trends at 3 months. Additionally, dAM-sBCL significantly reduced mature CDC counts, suggesting an anti-inflammatory effect. Conclusions: Treatment with dAM-sBCL for just 1 week significantly and rapidly improved dry eye symptoms as well as ocular surface signs for at least 3 months. It also enhanced corneal nerve health while reducing activated/mature corneal inflammatory cell numbers, presenting a safe and promising new treatment for moderate-to-severe DED.


Assuntos
Âmnio , Síndromes do Olho Seco , Humanos , Síndromes do Olho Seco/terapia , Masculino , Feminino , Âmnio/transplante , Pessoa de Meia-Idade , Adulto , Lentes de Contato , Resultado do Tratamento , Idoso , Qualidade de Vida , Bandagens , Córnea
8.
Medicina (Kaunas) ; 60(10)2024 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-39459390

RESUMO

Background and Objectives: Infrared light is used to image the Meibomian glands through their thermal profile. This study aimed to investigate the effects of a combination of heating and an eyelid massage on Meibomian gland visibility and tear film parameters. Materials and Methods: Twenty-four participants (26 ± 6.9 years) were enrolled in this prospective study, which involved imaging the Meibomian glands of both the lower and upper eyelid and assessing the non-invasive breakup time (NIBUT), tear meniscus height (TMH), and blink rate (using the CA-800, Topcon) at baseline after five minutes of eyelid warming followed by a five-minute eyelid massage. The second session, which was randomised in sequence, repeated the same measurements but without the inclusion of any eyelid warming or massage as the control condition. Results: While there was no change in lower lid Meibomian gland appearance as a result of eyelid heating, eyelid massage, or multiple lid eversion (median 2.0, range 0.0 to 4.0; p = 0.782), there was a change in upper lid appearance 5 min after heating and lid massage (p = 0.025), but again, multiple lid eversion had no effect (p > 0.05). The NIBUT decreased on second lid eversion (p = 0.049), although this was not evident on the third lid eversion (p = 0.090). The effect on NIBUT was also apparent with heating (p = 0.034 immediately after) but was sustained with 5 min of eyelid massage (p = 0.031). The TMH increased with heating (p < 0.001), and this effect was sustained with 5 min of eyelid massage (p = 0.011), but there was no lid eversion effect (p > 0.05). The blink rate was unaffected by heating, eyelid massage, or multiple eversions of the eyelids (median 24 blinks/min, range 8 to 59 blinks/min; p = 0.61). Conclusions: Eyelid warming can increase the visibility of the Meibomian glands, although this effect was only observed with upper lid imaging and the effect dissipated after 5 min of eyelid massage. Warming and massage also disrupt the tear film, as does multiple lid eversion, emphasising the need to use the least invasive tear film assessment techniques first.


Assuntos
Massagem , Glândulas Tarsais , Humanos , Glândulas Tarsais/diagnóstico por imagem , Feminino , Masculino , Adulto , Estudos Prospectivos , Massagem/métodos , Lágrimas/fisiologia , Temperatura Alta/efeitos adversos , Raios Infravermelhos , Calefação/métodos , Pálpebras/fisiologia , Adulto Jovem
9.
Ophthalmic Physiol Opt ; 43(5): 1079-1091, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37357424

RESUMO

PURPOSE: Dry eye disease (DED) is a growing global health problem with a significant impact on the quality of life of patients. While neurosensory abnormalities have been recognised as a contributor to DED pathophysiology, the potential role of in vivo corneal confocal microscopy in detecting nerve loss or damage remains unclear. This systematic review with meta-analysis (PROSPERO registered CRD42022381861) investigated whether DED has an impact on sub-basal corneal nerve parameters. METHODS: PubMed, Embase and Web of Science Core Collection databases were searched from inception to 9 December 2022. Studies using laser scanning confocal microscopy to compare corneal nerve parameters of DED with healthy eyes were included. Study selection process and data extraction were performed by two independent members of the review team. RESULTS: Twenty-two studies with 916 participants with DED and 491 healthy controls were included, with 21 of these studies included in subsequent meta-analyses. There was a decrease in total corneal nerve length (-3.85 mm/mm2 ; 95% CI -5.16, -2.55), corneal main nerve trunk density (-4.81 number/mm2 ; 95% CI -7.94, -1.68) and corneal nerve branch density (-15.52 number/mm2 ; 95% CI -27.20, -3.84) in DED eyes compared with healthy eyes, with subgroup analysis demonstrating that these differences were more evident in studies using NeuronJ software, a semi-automated procedure. While this review found evidence of loss of corneal nerve parameters in eyes with DED compared with healthy controls, particularly with the use of a semi-automated image analysis method, it is evident that there is substantial heterogeneity between studies in terms of corneal nerve imaging methodology. CONCLUSIONS: Standardisation is required in terms of terminology and analysis, with more research needed to potentially improve the clinical applicability and practicality of corneal nerve imaging. Further investigation is also required to confirm the diagnostic accuracy of this imaging modality and its potential for monitoring DED treatment efficacy.


Assuntos
Síndromes do Olho Seco , Qualidade de Vida , Humanos , Córnea/inervação , Síndromes do Olho Seco/diagnóstico , Processamento de Imagem Assistida por Computador , Microscopia Confocal/métodos
10.
Ophthalmic Physiol Opt ; 43(1): 25-34, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36169043

RESUMO

PURPOSE: To compare objective and subjective digital near visual performance and comfort in low to moderate astigmatic participants fitted with toric versus spherical equivalent silicone hydrogel daily disposable contact lenses. METHODS: This was a double-masked, randomised, crossover study. Participants aged 18 to 39 years with astigmatism of -0.75 to -1.50 D were recruited and fitted with toric and spherical contact lenses, in random order. Outcomes were measured at baseline and after 1 week of wear with each contact lens type after the follow-up visits. High- and low-contrast near logMAR visual acuity, automated visual acuity, zoom (%), contrast (%), reading distance (cm), critical print size (logMAR) and reading speed were assessed. Participants also completed the validated Near Activity Visual Questionnaire (NAVQ) and Contact Lens Dry Eye Questionnaire 8 (CLDEQ-8) for each correction type. RESULTS: Twenty-three participants completed the study (74% female, average age 24.4 ± 4.2 years). When participants wore toric contact lenses, near high- and low-contrast visual acuity and automated visual acuity improved by 3-4 letters (all p < 0.03) and participants were able to read faster on an iPad (p = 0.02). Participants were also able to read with 8% less contrast on the iPad with toric lenses (p = 0.01). Participants reported better subjective vision on the overall NAVQ (p = 0.001) and better comfort on the CLDEQ-8 (p = 0.02) with toric lenses. Fewer participants reported difficulty with maintaining focus at near, reading small print, reading labels/instructions, reading the computer display/keyboard and reading post/mail with toric correction. CONCLUSIONS: Toric contact lenses improve comfort, subjective and objective visual performance with digital devices and other near tasks compared with the spherical equivalent correction in participants with low to moderate astigmatism.


Assuntos
Lentes de Contato , Feminino , Humanos , Adulto Jovem , Adulto , Masculino , Estudos Cross-Over
11.
Ophthalmic Physiol Opt ; 43(6): 1562-1570, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37476960

RESUMO

PURPOSE: ChatGPT is an artificial intelligence language model, which uses natural language processing to simulate human conversation. It has seen a wide range of applications including healthcare education, research and clinical practice. This study evaluated the accuracy of ChatGPT in providing accurate and quality information to answer questions on myopia. METHODS: A series of 11 questions (nine categories of general summary, cause, symptom, onset, prevention, complication, natural history, treatment and prognosis) were generated for this cross-sectional study. Each question was entered five times into fresh ChatGPT sessions (free from influence of prior questions). The responses were evaluated by a five-member team of optometry teaching and research staff. The evaluators individually rated the accuracy and quality of responses on a Likert scale, where a higher score indicated greater quality of information (1: very poor; 2: poor; 3: acceptable; 4: good; 5: very good). Median scores for each question were estimated and compared between evaluators. Agreement between the five evaluators and the reliability statistics of the questions were estimated. RESULTS: Of the 11 questions on myopia, ChatGPT provided good quality information (median scores: 4.0) for 10 questions and acceptable responses (median scores: 3.0) for one question. Out of 275 responses in total, 66 (24%) were rated very good, 134 (49%) were rated good, whereas 60 (22%) were rated acceptable, 10 (3.6%) were rated poor and 5 (1.8%) were rated very poor. Cronbach's α of 0.807 indicated good level of agreement between test items. Evaluators' ratings demonstrated 'slight agreement' (Fleiss's κ, 0.005) with a significant difference in scoring among the evaluators (Kruskal-Wallis test, p < 0.001). CONCLUSION: Overall, ChatGPT generated good quality information to answer questions on myopia. Although ChatGPT shows great potential in rapidly providing information on myopia, the presence of inaccurate responses demonstrates that further evaluation and awareness concerning its limitations are crucial to avoid potential misinterpretation.

12.
Eye Contact Lens ; 49(11): 498-504, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37713618

RESUMO

OBJECTIVES: Human tears have the potential to be used as biomarkers to aid in the diagnosis and management of dry eye disease (DED). This prospective, controlled pilot study aimed to investigate the hypothesis that a panel of tear protein profiles can be detected and are repeatable when analyzed using a miniaturized quantitative microfluidic system. METHODS: Ten participants were recruited following institutional ethics committee approval. Participants attended two visits 1 week apart when the following measurements were taken in a sequence: tear meniscus height, noninvasive breakup time, ocular redness, tear collection, and corneal and conjunctival staining. Basal tears (>4 µL) were collected using glass microcapillary tubes. Tears were processed to analyze a panel of proteins (14-230 kDa) following the manufacturer's guidelines using a miniaturized quantitative microfluidic system (Protein 230 LabChip with Agilent 2100 Bioanalyzer). Demographics of the clinical measurements and a comparison of the panel of identified proteins and their repeatability were made. RESULTS: Mean age of the participants was 20.8±1.6 years, nine were females, three fulfilled the TFOS DEWS-II diagnostic criteria for DED. The total protein concentration across participants was 6.72±3.56 mg/mL. Several proteins (lysozyme C, lipocalin 1, IgA light chain, zinc-α2-glycoprotein, albumin, and lactoferrin) were identified at both visits for seven or more participants. There were no significant differences ( P >0.05) in individual protein concentrations between the two visits. A high correlation was found between the two visits for all proteins where correlation coefficient ranged between 0.63 and 0.98 ( P <0.05). CONCLUSION: The protein profiles measured by the quantitative microfluidic system are repeatable, thus validating quantitative microfluidic system as a reliable method for investigating a panel of tear proteins. This method is quick, affordable, requires only 4 µL of tear, and is relatively easy method to perform that can be incorporated in a clinical setting. Further studies in larger clinical setting may be beneficial exploring the usability of this method in various patient groups.


Assuntos
Síndromes do Olho Seco , Microfluídica , Feminino , Humanos , Masculino , Adulto Jovem , Córnea/metabolismo , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/metabolismo , Projetos Piloto , Estudos Prospectivos , Lágrimas/metabolismo
13.
Optom Vis Sci ; 99(4): 342-349, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35121719

RESUMO

SIGNIFICANCE: The contrast sensitivity (CS) function provides a more detailed assessment of vision than visual acuity. It was found that center-distance multifocal contact lens designs that are increasingly being prescribed for myopia control reduce distance photopic and mesopic CS in nonpresbyopic patients across a range of spatial frequencies. PURPOSE: This study aimed to determine the effect of center-distance multifocal soft contact lenses (MFCLs) on CS under photopic and mesopic conditions in nonpresbyopic patients. METHODS: Twenty-five myopic, nonpresbyopic adults were fitted binocularly with three lenses: Biofinity single vision contact lens (SVCL), Biofinity Multifocal D +2.50 add, and NaturalVue Multifocal in random order. Contrast sensitivity was measured at distance (4 m) under photopic and mesopic conditions and at near under photopic conditions. Log CS by spatial frequency and area under the log contrast sensitivity function (AULCSF) were analyzed between lenses. RESULTS: Distance photopic CS at each spatial frequency was higher with the SVCL than the MFCLs (P < .001), but there was no difference between the MFCLs (P = .71). Distance mesopic CS from 1.5 to 12 cycles per degree (cpd) was higher with the SVCL than the MFCLs (all P < .02); however, at 18 cpd, there was no difference in CS between NaturalVue and the SVCL (P = .76), possibly because of spurious resolution. Photopic AULCSF for the SVCL was roughly 10% greater than both MFCLs. Contrast sensitivity at near was generally similar between lenses, only slightly lower with the NaturalVue at 11 and 15.5 cpd, but AULCSF at near was not different between lenses (P > .05). CONCLUSIONS: Multifocal contact lenses reduce distance contrast sensitivity under both photopic and mesopic conditions. There is no clinically significant difference in near CS among all three lenses. These data show that MFCLs have effects on vision that are not captured by standard high-contrast visual acuity testing.


Assuntos
Lentes de Contato Hidrofílicas , Miopia , Adulto , Sensibilidades de Contraste , Humanos , Miopia/terapia , Testes Visuais , Acuidade Visual
14.
Ophthalmic Physiol Opt ; 42(5): 1023-1031, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35703419

RESUMO

PURPOSE: To investigate the validity of Placido-based corneal topography parameters to predict corneoscleral sagittal heights measured by Fourier-based profilometry at various diameters. METHODS: Minimal (Minsag ), maximal (Maxsag ) sagittal height, toricity (Maxsag - Minsag ) and axis of the flattest meridian (Minsag ) of 36 subjects (mean age 25.4 SD ± 3.2 years; 21 female) were measured using the Eye Surface Profiler and analysed for diameters (chord length) of 8 to 16 mm (in 2-mm intervals). Furthermore, corneal central radii, corneal astigmatism, eccentricity and diameter were measured using the Keratograph 5 M. RESULTS: Using multiple linear regression analysis, the best equation for predicting the sagittal heights for 8 mm (r2  = 0.95), and 10 mm (r2  = 0.93) diameters included corneal central radii and eccentricity. The best equation for predicting sagittal heights for 12 mm (r2  = 0.86), 14 mm (r2  = 0.78) and 16 mm (r2  = 0.65) diameters included corneal central radii, eccentricity and corneal diameter. Corneal astigmatism was significantly correlated with sagittal height toricity for 8 and 10 mm diameters (r2  = 0.50 and 0.29; p < 0.01), while no correlation was observed for 12, 14 and 16 mm diameters (p = 0.18 to p = 0.76). The axis of the flattest corneal meridian measured by Placido-based topography was significantly correlated with the axis of the flattest meridian measured by Fourier-based profilometry for 8, 10 and 12 mm diameters (r2  = 0.17 to 0.44; p < 0.05), while there was no correlation for 14 and 16 mm diameters (p = 0.48 and p = 0.75). For a typical soft contact lens diameter of 14 mm, 78% of the variance could be determined with a corneal topographer and 68% with keratometry and corneal diameter measurement. CONCLUSIONS: The combination of corneal central radii, eccentricity and corneal diameter measured by Placido-based topography is a valid predictor of the corneoscleral sagittal height in healthy eyes. Scleral toricity and axis of the flattest meridian seem to be independent from Placido-based corneal parameters and requires additional measuring tools.


Assuntos
Astigmatismo , Lentes de Contato Hidrofílicas , Doenças da Córnea , Adulto , Astigmatismo/diagnóstico , Córnea , Topografia da Córnea , Feminino , Humanos , Esclera
15.
Int Ophthalmol ; 42(5): 1563-1571, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35094228

RESUMO

PURPOSE: To compare optical and visual performances of two one-piece aspherical implanted intraocular lenses (IOLs) following phacoemulsification cataract surgery in a contralateral eye study. METHODS: In this prospective randomized parallel-group study, 25 patients with bilateral age-related cataract were implanted in one eye with the EnVista IOL (MX60, Bausch & Lomb Corporations, Rochester, NY, USA) and the Acrysof IQ IOL (Acrysof IQ SN60WF, Alcon Surgical Laboratories, Fort Worth, TX, USA) in the other eye. Uncorrected and corrected distance visual acuity (UDVA, CDVA), refractive status, higher-orders aberrations (HOAs) in 5 and 6 mm pupil size, contrast sensitivity (CS) with and without glare, color vision status, and patient satisfaction were assessed in the two eyes at 1 and 3 months after surgery. RESULTS: There was no significant difference in CDVA (P > 0.99), UDVA (P = 0.46), spherical equivalent refractive error (P = 0.63), CS with and without glare across different spatial frequencies, color vision, and root mean square (RMS) of aberrometric values between the two IOLs after 3-month follow-up. Spherical aberration with 5 and 6 mm pupil sizes (P = 0.02) and horizontal coma with a 6 mm pupil size (P < 0.001) were lower with the EnVista IOL. Patient's satisfaction showed no cases of dissatisfaction, and most patients were highly or moderately satisfied with both IOLs. CONCLUSION: The visual and optical performance of eyes implanted with the EnVista IOL or the Acrysof IQ IOL was similar, although the aberration profile differed.


Assuntos
Catarata , Lentes Intraoculares , Facoemulsificação , Sensibilidades de Contraste , Humanos , Implante de Lente Intraocular , Estudos Prospectivos , Desenho de Prótese
16.
Optom Vis Sci ; 98(3): 272-279, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33771957

RESUMO

PURPOSE: The purpose of this study was to examine the visual performance of center-distance MFCLs in nonpresbyopic adults under different illumination and contrast conditions compared with a single-vision contact lens (SVCL). METHODS: Twenty-five adult subjects were fit with three different lenses (CooperVision Biofinity D MFCL +2.50 add, Visioneering Technologies NaturalVue MFCL, CooperVision Biofinity sphere). Acuity and reading performance were evaluated. RESULTS: A statistically significant difference in high-contrast distance acuity was observed (Biofinity, -0.18 ± 0.06; Biofinity MFCL, -0.14 ± 0.08; NaturalVue MFCL, -0.15 ± 0.03; repeated-measures [RM] ANOVA, P = .02). Under mesopic, high-contrast conditions, MFCLs performed worse than SVCLs (Biofinity, -0.05 ± 0.091; Biofinity MFCL, +0.03 ± 0.09; NaturalVue MFCL, +0.05 ± 0.091; RM-ANOVA, P < .0001). Under low-contrast conditions, MFCLs performed one line worse in photopic lighting and two lines worse under mesopic conditions (RM-ANOVA, P < .0001). Glare reduced acuity by 0.5 logMAR for all lenses (RM-ANOVA, P < .001). A statistically significant difference in near acuity was observed (RM-ANOVA, P = .02), but all lenses achieved acuity better than -0.1 logMAR (Biofinity, -0.16 ± 0.06; Biofinity MFCL, -0.17 ± 0.04; NaturalVue MFCL, -0.13 ± 0.08). Reading performance in words per minute (wpm) was worse with MFCLs (Biofinity MFCL, 144 ± 22 wpm; NaturalVue MFCL, 150 ± 28 wpm) than with SVCLs (156 ± 23 wpm; RM-ANOVA, P = .02) regardless of letter size (RM-ANOVA, P = .13). No difference in acuity between the MFCLs was detected (RM-ANOVA: all, P > .05). CONCLUSIONS: Multifocal contact lenses perform similarly to SVCLs for high-contrast targets and display reduced low-contrast acuity and reading speed. Practitioners should recognize that high-contrast acuity alone does not describe MFCL visual performance.


Assuntos
Lentes de Contato , Miopia/terapia , Acuidade Visual/fisiologia , Adulto , Visão de Cores/fisiologia , Sensibilidades de Contraste/fisiologia , Estudos Cross-Over , Feminino , Ofuscação , Humanos , Luz , Masculino , Miopia/fisiopatologia , Ajuste de Prótese , Refração Ocular/fisiologia , Método Simples-Cego , Adulto Jovem
17.
Ophthalmic Physiol Opt ; 41(6): 1165-1175, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34545597

RESUMO

PURPOSE: To investigate the attitudes and understanding of optometrists in the UK and Ireland towards Digital Eye Strain (DES), and to examine related practice patterns. METHODS: An anonymous online questionnaire was developed, covering attitude and understanding of DES, examination of patients who may be experiencing DES and approaches to management options. The questionnaire was promoted to UK and Ireland optometrists via professional bodies and local and area optometric committees. RESULTS: 406 responses were included in the analysis. Most respondents agreed that DES was an important concern for optometrists (88.9%). 91.4% reported they felt confident in discussing possible symptoms of DES and management options; this was weakly and negatively associated with number of years qualified (rs  = -0.198, p ≤ 0.001). Estimations of the proportion of patients affected by DES were lower than reports in the literature (median 25%, IQR 10%-50%). Most respondents always (60.6%) or frequently (21.9%) inquired about device usage in routine case history taking, and also asked follow-up questions, although 29.3% only asked about the presence of symptoms half the time or less. Advising on regular breaks (84.0%), lubricants (55.7%) and environment/set up (69.2%) were felt to be extremely or very important by most respondents. Advising on specialist spectacle lenses, specifically blue filtering designs, was considered extremely or very important by 34.2% and 15.2%, respectively. CONCLUSION: Given the agreement that DES is a significant issue causing frequent and persistent symptoms, and practitioners reported high levels of confidence in discussing DES, patients can expect to receive advice on symptoms and management from their optometrist. Simple management strategies were felt to be most important to advise on, with more uncertainty linked to specialist spectacle lenses.


Assuntos
Optometristas , Optometria , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Irlanda , Reino Unido
18.
Ophthalmic Physiol Opt ; 41(2): 266-280, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33533098

RESUMO

PURPOSE: Low Vision Aids (LVAs) can have a transformative impact on people living with sight loss, yet the everyday requirements for developing such devices remain poorly understood and defined. This study systematically explored LVA requirements through a structured de-brief interview following a real-world self-recording study. The purpose of this work was to define the actual needs of those living with sight loss so that low vision services can better address them in future. METHODS: Thirty-two visually impaired volunteers with varying levels of previous LVA experience participated in a de-brief interview centred around a structured questionnaire. The de-brief followed a one-week real-world study during which participants used recoding spectacles to capture and narrate all situations in which they would use a 'perfect sight aid'. Content and thematic analyses were used to analyse interviews which had the purpose of contextualising these recordings and exploring requirements around psychological, functional and design factors. RESULTS: Participants reported that 46% of tasks which they had recorded were most important to them. Of these tasks, 82% were encountered frequently. Few tasks emerged as very important across many participants, the remaining tasks reflecting individual lifestyles or circumstances. Every participant used at least one LVA in their everyday life and 72% identified further coping strategies. Current LVAs identified as consistently poor were distance LVAs, with all other devices receiving mixed or only positive feedback. Around two-thirds of participants would prefer LVA use on an ad-hoc / quick access basis rather than over long periods of time, and just over half would prefer to carry it rather than wearing it all day. Lack of consistency in these responses illustrated potentially different user clusters with divergent design needs. Two-thirds of participants emphasised the desire for a discreet LVA that does not attract attention. However, since half of all participants felt self-conscious in public or in front of other people when wearing the small recording spectacles, this may not be technically achievable. CONCLUSIONS: There is a substantial opportunity for new LVAs to address visual needs that traditional devices and coping strategies cannot support. Functional, psychological and design factors require careful consideration for future LVAs to be relevant and widely adopted.


Assuntos
Adaptação Psicológica/fisiologia , Óculos , Qualidade de Vida , Auxiliares Sensoriais/estatística & dados numéricos , Baixa Visão/reabilitação , Acuidade Visual , Pessoas com Deficiência Visual/reabilitação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Leitura , Baixa Visão/fisiopatologia , Pessoas com Deficiência Visual/estatística & dados numéricos , Adulto Jovem
19.
Eye Contact Lens ; 47(8): 445-448, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33813585

RESUMO

OBJECTIVES: To evaluate the effect of eye spray phospholipid concentration on symptoms and tear film stability. METHODS: High-concentration (Tears Again, Optima Pharma GmbH, Hallbergmoos, Germany) and low-concentration (Ocuvers, Innomedis AG, Germany) phospholipid eye sprays were sprayed onto the closed eyelids of 30 subjects (33.2±1.8 years; 20 women) in a multicentered, prospective, crossover study. Ocular comfort (visual analog scale) and noninvasive tear film stability (NIBUT) of each eye were evaluated before application (along with the Ocular Surface Disease Index), 10 min after application, and 30 min after application. RESULTS: Comfort (high concentration: 68.5±16.4 vs. low concentration: 70.7±14.5 phospholipid) and NIBUT (high concentration: 11.5±4.6 sec vs. low concentration: 11.2±6.0 sec phospholipid) were not different (P>0.3) between sprays before application, but comfort (by 12 points, P=0.001) and NIBUT (by 5 sec, P=0.016) were significantly better with a high-concentration phospholipid spray at both 10 min and 30 min time points than those with the low-concentration phospholipid spray. CONCLUSIONS: The liposomal eye spray with higher concentration of phospholipids significantly improved ocular comfort and tear film stability in contrast to the eye spray with lower concentration of phospholipids, hence practitioners need to choose an appropriate eye spray to maximize the patient benefit.


Assuntos
Síndromes do Olho Seco , Fosfolipídeos , Estudos Cross-Over , Síndromes do Olho Seco/tratamento farmacológico , Feminino , Humanos , Lipossomos , Estudos Prospectivos , Lágrimas
20.
Optom Vis Sci ; 97(9): 766-774, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32941338

RESUMO

SIGNIFICANCE: Precise measurement of corneoscleral topography makes a valuable contribution to the understanding of anterior eye anatomy and supports the fitting process of contact lenses. Sagittal height data, determined by newer noninvasive techniques, are particularly useful for initial scleral lens selection. PURPOSE: The purpose of this study was to investigate the agreement and repeatability of Fourier-based profilometry and Scheimpflug imaging, in the measurement of sagittal height and toricity of the corneoscleral region. METHODS: Minimal (Minsag), maximal (Maxsag) sagittal height, toricity (Maxsag - Minsag), and the maximum possible measurement zone diameter of 38 subjects were compared using the Eye Surface Profiler (ESP; Eagle Eye, Houten, the Netherlands) and the corneoscleral profile module of the Pentacam (Oculus, Wetzlar, Germany) at two different sessions. Correlations between the instruments were analyzed using the Pearson coefficient. Differences between sessions and instruments were analyzed using Bland-Altman and paired t tests. RESULTS: For an equal chord length, the measurement with Pentacam was significantly greater for Minsag (344 µm; 95% confidence interval [CI], 322 to 364 µm; P < .001) and significantly greater for Maxsag (280 µm; 95% CI, 256 to 305 µm; P < .001), but significantly smaller for toricity (-63 µm; 95% CI, -95 to -31 µm; P < .001). Maximum possible measurement zone diameter with ESP (16.4 ± 1.3 mm) was significantly greater than with Pentacam (14.8 ± 1.1 mm) (P < .001). Repeated measurements from session 1 and session 2 were not significantly different for Pentacam and ESP (P = .74 and P = .64, respectively). The 95% CIs around differences indicate good repeatability for Pentacam (mean difference, -0.9 µm; 95% CI, -6.7 to 4.8 µm) and ESP (4.6 µm; -22.4 to 31.6). CONCLUSIONS: Although both instruments deliver useful data especially for the fitting of scleral and soft contact lenses, the sagittal height and the toricity measurements cannot be considered as interchangeable.


Assuntos
Topografia da Córnea , Diagnóstico por Imagem , Limbo da Córnea/anatomia & histologia , Adulto , Lentes de Contato , Feminino , Análise de Fourier , Humanos , Limbo da Córnea/diagnóstico por imagem , Masculino , Estudos Prospectivos , Ajuste de Prótese , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA