Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Assunto principal
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Mol Pharm ; 20(11): 5616-5630, 2023 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-37812508

RESUMO

Accurate prediction of human pharmacokinetics (PK) remains one of the key objectives of drug metabolism and PK (DMPK) scientists in drug discovery projects. This is typically performed by using in vitro-in vivo extrapolation (IVIVE) based on mechanistic PK models. In recent years, machine learning (ML), with its ability to harness patterns from previous outcomes to predict future events, has gained increased popularity in application to absorption, distribution, metabolism, and excretion (ADME) sciences. This study compares the performance of various ML and mechanistic models for the prediction of human IV clearance for a large (645) set of diverse compounds with literature human IV PK data, as well as measured relevant in vitro end points. ML models were built using multiple approaches for the descriptors: (1) calculated physical properties and structural descriptors based on chemical structure alone (classical QSAR/QSPR); (2) in vitro measured inputs only with no structure-based descriptors (ML IVIVE); and (3) in silico ML IVIVE using in silico model predictions for the in vitro inputs. For the mechanistic models, well-stirred and parallel-tube liver models were considered with and without the use of empirical scaling factors and with and without renal clearance. The best ML model for the prediction of in vivo human intrinsic clearance (CLint) was an in vitro ML IVIVE model using only six in vitro inputs with an average absolute fold error (AAFE) of 2.5. The best mechanistic model used the parallel-tube liver model, with empirical scaling factors resulting in an AAFE of 2.8. The corresponding mechanistic model with full in silico inputs achieved an AAFE of 3.3. These relative performances of the models were confirmed with the prediction of 16 Pfizer drug candidates that were not part of the original data set. Results show that ML IVIVE models are comparable to or superior to their best mechanistic counterparts. We also show that ML IVIVE models can be used to derive insights into factors for the improvement of mechanistic PK prediction.


Assuntos
Líquidos Corporais , Humanos , Simulação por Computador , Descoberta de Drogas , Cinética , Aprendizado de Máquina , Modelos Biológicos , Taxa de Depuração Metabólica
2.
Anal Chem ; 76(9): 2595-600, 2004 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-15117203

RESUMO

The transfer of partial least squares (PLS) calibration models among four near-infrared spectrometers was investigated for the quantitative analysis of thermoset resin polymers. A comparative study of second derivatives, multiplicative scatter correction, finite impulse response filtering, slope and bias correction, model updating (MU), and orthogonal signal correction (OSC) was conducted to determine which processing methods achieved model transferability. It is shown that OSC and MU were superior to the other calibration transfer methods, leading to very robust PLS models with enhanced predictive ability. It is also shown that the transfer results obtained with OSC were not significantly different from those obtained with model updating.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA