Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Appl Opt ; 63(12): 3130-3137, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38856457

RESUMO

Numerous applications at the photon-starved regime require a free-space coupling single-photon detector with a large active area, low dark count rate (DCR), and superior time resolutions. Here, we developed a superconducting microstrip single-photon detector (SMSPD), with a large active area of 260 µm in diameter, a DCR of ∼5k c p s, and a low time jitter of ∼171p s, operated at a near-infrared of 1550 nm and a temperature of ∼2.0K. As a demonstration, we applied the detector to a single-pixel galvanometer scanning system and successfully reconstructed the object information in depth and intensity using a time-correlated photon counting technology.

2.
Opt Express ; 31(10): 16348-16360, 2023 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-37157715

RESUMO

The effective and convenient detection of single photons via advanced detectors with a large active area is becoming significant for quantum and classical applications. This work demonstrates the fabrication of a superconducting microstrip single-photon detector (SMSPD) with a millimeter-scale active area via the use of ultraviolet (UV) photolithography. The performances of NbN SMSPDs with different active areas and strip widths are characterized. SMSPDs fabricated by UV photolithography and electron beam lithography with small active areas are also compared from the aspects of the switching current density and line edge roughness. Furthermore, an SMSPD with an active area of 1 mm × 1 mm is obtained via UV photolithography, and during operation at 0.85 K, it exhibits near-saturated internal detection efficiency at wavelengths up to 800 nm. At a wavelength of 1550 nm, the detector exhibits a system detection efficiency of ∼5% (7%) and a timing jitter of 102 (144) ps, when illuminated with a light spot of ∼18 (600) µm in diameter, respectively.

3.
Phys Rev Lett ; 130(21): 210801, 2023 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-37295116

RESUMO

Quantum key distribution (QKD) aims to generate secure private keys shared by two remote parties. With its security being protected by principles of quantum mechanics, some technology challenges remain towards practical application of QKD. The major one is the distance limit, which is caused by the fact that a quantum signal cannot be amplified while the channel loss is exponential with the distance for photon transmission in optical fiber. Here using the 3-intensity sending-or-not-sending protocol with the actively-odd-parity-pairing method, we demonstrate a fiber-based twin-field QKD over 1002 km. In our experiment, we developed a dual-band phase estimation and ultra-low noise superconducting nanowire single-photon detectors to suppress the system noise to around 0.02 Hz. The secure key rate is 9.53×10^{-12} per pulse through 1002 km fiber in the asymptotic regime, and 8.75×10^{-12} per pulse at 952 km considering the finite size effect. Our work constitutes a critical step towards the future large-scale quantum network.


Assuntos
Fótons , Física , Feminino , Gravidez , Humanos , Frequência Cardíaca
4.
Appl Opt ; 62(16): 4203-4212, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37706905

RESUMO

We propose a method for coupling a tapered optical fiber to an inverted tapered SiN waveguide by fabricating a microfiber using 3D nanoprinting lithography. The microfiber consists of three parts: a tapered cladding cap, an S-bend, and a straight part, all composed of high-refractive-index material. Light is adiabatically coupled from the tapered fiber to the printed microfiber through the cladding cap. The light is then transmitted through the S-bend and the straight part with low loss and is finally coupled to the waveguide through the evanescent field. In the simulation, our design can achieve a high coupling efficiency (TE mode) of ∼97% at a wavelength of 1542 nm with a wide bandwidth of ∼768n m at the 1-dB cutoff criterion.

5.
Opt Lett ; 46(5): 1049-1052, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33649654

RESUMO

We report a compact, scalable, and high-performance superconducting nanowire single-photon detector (SNSPD) array by using a multichannel optical fiber array-coupled configuration. For single pixels with an active area of 18 µm in diameter and illuminated at the telecom wavelength of 1550 nm, we achieved a pixel yield of 13/16 on one chip, an average system detection efficiency of 69% at a dark count rate of 160 cps, a minimum timing jitter of 74 ps, and a maximum count rate of ∼40Mcps. The optical crosstalk coefficient between adjacent channels is better than -60dB. The performance of the fiber array-coupled detectors is comparable with a standalone detector coupled to a single fiber. Our method is promising for the development of scalable, high-performance, and high-yield SNSPDs.

6.
Food Chem ; 425: 136486, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37267785

RESUMO

An imbalance of l-tryptophan (l-Trp), a basic component of a healthy diet, is harmful to human health. Traditional methods for detecting l-Trp have many limitations. To correct a deficiency or excess of l-Trp in human diets, it is necessary to develop a novel method that is rapid, low-cost, and high-sensitivity. Herein, a molecularly imprinted polysaccharide electrochemical sensor termed MIP/CS/MWCNTs/GCE (molecularly imprinted polymer/chitosan/multiwalled carbon nanotubes/glassy carbon electrode) targeting l-Trp was first constructed on a glassy carbon electrode, which was modified with multiwalled carbon nanotubes and chitosan using bifunctional monomers. The MIP/CS/MWCNTs/GCE obtained a wide linear range (1-300 µM) for detecting l-Trp and accurately detected the proportion of l-Trp in mixtures of Trp enantiomers. In milk samples, the spiked recoveries of l-Trp were 86.50 to 99.65%. The MIP/CS/MWCNTs/GCE electrochemical sensor possessed good recognition and detection performance for l-Trp and has promising potential for practical application.


Assuntos
Quitosana , Impressão Molecular , Nanotubos de Carbono , Humanos , Impressão Molecular/métodos , Polímeros , Triptofano , Técnicas Eletroquímicas/métodos , Eletrodos , Dieta , Limite de Detecção
7.
Am J Chin Med ; 50(8): 2085-2102, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36250390

RESUMO

The development of effective drug-loaded dressings has been considered a hot research topic for biomedical therapeutics, including the use of botanical compounds. For wound healing, adequate dressings can provide a good microenvironment for drug release, such as lidocaine. Biological macromolecular materials such as alginate show excellent properties in wound management. This study involves the preparation and evaluation of biocompatible multilayered-structure microspheres composed of chitosan, porous gelatin, and calcium alginate microspheres. The multilayered structure microspheres were named chitosan@ porous gelatin@ calcium alginate microspheres (CPAMs) and the drugs were rapidly released by the volume expansion of the calcium alginate microspheres. The in vitro release curve revealed that the peak release of lidocaine from CPAMs was reached within 18[Formula: see text]min. After 21[Formula: see text]min, the remaining lidocaine was then slowly released, and the active drug release was converted to a passive drug release phase. The initial release effect of lidocaine was much better than that reported in the published studies. Additionally, blood coagulation experiments showed that CPAMs coagulated blood in 60[Formula: see text]s, and the blood liquidity of the CPAMs group was worse than that of the woundplast group. Therefore, the coagulation characteristics of CPAMs were superior to the commonly used woundplast containing lidocaine healing gel. These study outcomes indicated that the CPAMs acted as fast-release dressings for faster pain control and better coagulation properties.


Assuntos
Alginatos , Quitosana , Humanos , Alginatos/química , Microesferas , Lidocaína , Quitosana/química , Gelatina , Bandagens , Dor
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA