Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 154
Filtrar
1.
Pacing Clin Electrophysiol ; 47(3): 437-439, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-37260106

RESUMO

We report a case of atrial fibrillation (AF) recurrence after pulmonary vein isolation, which patient had AF trigger in the superior vena cava (SVC) near the sinus node (SN). The ultra-high-resolution mapping revealed that SN located within the SVC and the atrial activation from the SN to SVC propagated in both septal and lateral direction, then upward with circumventing the spontaneous conduction block identified just above and lateral SN (upper hemisphere). We successfully isolated SVC including the ectopic origin at the same level as the SN by utilizing the spontaneous conduction block line around the SN without any complication.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veia Cava Superior/cirurgia , Fibrilação Atrial/cirurgia , Nó Sinoatrial , Átrios do Coração , Bloqueio Cardíaco , Veias Pulmonares/cirurgia
2.
Heart Vessels ; 39(7): 616-625, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38526754

RESUMO

Accurate measurement of the pulmonary vein dimension (PVD) is important for determining stenosis and efficacy following pulmonary vein isolation (PVI). Little is known about the quantitative evaluation of the impact of the cardiac cycle on pulmonary vein (PV) morphology before and after PVI. This study aims to investigate variations in the ostial size of the PV during the cardiac cycle before and after PVI and the effect of the cardiac cycle on PV stenosis and reduction rate using cardiac computed tomography (CT). Sixty-eight patients with atrial fibrillation who underwent cardiac CT before and after PVI at our institution between 23 January 2021 and 5 February 2022 were retrospectively analyzed. The maximum and minimum PVD were measured at each segment before and after the PV. Each PV was evaluated according to the PVD reduction rate (ΔPVD), calculated as follows: (1 - post-PVD/pre-PVD) × 100 (%). The average dimension of all PVs at the end-diastolic frame was significantly reduced compared to that at the end-systolic frame before PVI. The average dimensions of the right superior and right inferior PV at the end-diastolic frame were significantly reduced compared with those at the end-systolic frame following PVI. The average reduction rate of dimension-classified stenosis of PVs, except for the left inferior PV at the end-diastolic frame, was significantly reduced compared with that at the end-systolic frame. The cardiac cycle affects PVD assessment, including PV stenosis, after PVI. PVD measurement is recommended to be unified to the end-systolic frame of the cardiac cycle to avoid underestimating PV stenosis before and after PVI, ensuring appropriate management and follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Masculino , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Ablação por Cateter/métodos , Idoso , Estenose de Veia Pulmonar/fisiopatologia , Estenose de Veia Pulmonar/etiologia , Estenose de Veia Pulmonar/diagnóstico , Estenose de Veia Pulmonar/cirurgia , Resultado do Tratamento , Seguimentos , Frequência Cardíaca/fisiologia
3.
Europace ; 25(12)2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-37950630

RESUMO

AIMS: The first-generation radiofrequency HotBalloon (RHB) is a size-adjustable single-shot device used in atrial fibrillation. The energy output is determined by its central temperature and not by its balloon surface temperature (BST), thus limiting its efficacy and safety. Therefore, a second-generation RHB was developed to monitor BST and enable BST-controlled ablation. This animal study aims to evaluate the accuracy of a newly developed BST-monitoring system and validate the optimal BST for ablation. METHODS AND RESULTS: In Protocol 1, thermocapsules were attached to the superior vena cava (SVC) epicardium. The accuracy of BST monitoring was examined during SVC isolation. In Protocol 2, the efficacy and safety of different BST-controlled ablations were examined. In the acute model, electrophysiological and pathological findings were assessed after energy applications with BST at 51, 54, 57, and 60°C. In the chronic model, the lesion durability and pathological findings were assessed 8 weeks after BST-controlled ablation (57 and 60°C). A significant positive correlation was found between the epicardial temperature and the BST-monitoring value (r = 0.98). In the acute model, all target veins were electrically isolated with BST-controlled ablation at ≥57°C (18/18, 100%). In the chronic model, durable lesions were observed in all veins at 60°C, while 44% of the veins showed reconnection at 57°C. In both pathological analyses, significantly greater lesions were observed at 60°C than at 57°C. There were no significant differences in adverse events between the two groups. CONCLUSION: Balloon surface temperature-controlled ablation at 60°C using the second-generation RHB may be optimal for creating durable lesions without compromising safety.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Animais , Temperatura , Veia Cava Superior/cirurgia , Estudos de Viabilidade , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Resultado do Tratamento
4.
Circ J ; 87(12): 1711-1719, 2023 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-37258224

RESUMO

BACKGROUND: Pulmonary vein stenosis (PVS) after PV isolation (PVI) for atrial fibrillation (AF) is a severe complication that requires angioplasty. This study aimed to compare the reduction of the cross-sectional PV area (PVA) and the incidence of PVS after cryoballoon (CB)-PVI, hot balloon (HB)-PVI, or laser balloon (LB)-PVI.Methods and Results: A total of 320 patients who underwent an initial catheter ablation procedure for AF using a CB, HB, or LB in 2 hospitals were included. They underwent contrast-enhanced multidetector CT before and 3 months after the procedure. In all 4 PVs, the reduction in PVA was more significant in the LB group than in the CB or HB groups, respectively. Moderate (50-75%) and severe (>75%) PVS were observed in 5.3% and 0.5% of the PVs, respectively. Although moderate PVS was more frequently observed in the LB group than in the CB or HB groups (8.2%, 3.8%, and 5.0%; P=0.03), the incidence of severe PVS was similar in the LB, CB, and HB groups (0.3%, 0.5%, and 1.0%; P=0.46). Symptomatic PVS requiring intervention occurred in 1 (0.3%) patient. CONCLUSIONS: Although the reduction in cross-sectional PVA and the incidence of moderate PVS after LB-PVI was more significant than after CB-PVI or HB-PVI, it rarely led to severe PVS. Symptomatic PVS requiring intervention was rare after the balloon ablation of AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Estenose de Veia Pulmonar , Humanos , Estenose de Veia Pulmonar/diagnóstico por imagem , Estenose de Veia Pulmonar/etiologia , Estudos Transversais , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Lasers
5.
Circ J ; 87(7): 939-946, 2023 06 23.
Artigo em Inglês | MEDLINE | ID: mdl-36464278

RESUMO

BACKGROUND: A recent randomized trial demonstrated that catheter ablation for atrial fibrillation (AF) in patients with heart failure with reduced ejection fraction (EF) is associated with a reduction in death or heart failure. However, the effect of catheter ablation for AF in patients with heart failure with mid-range or preserved EF is unclear.Methods and Results: We screened 899 AF patients (72.4% male, mean age 68.4 years) with heart failure and left ventricular EF ≥40% from 2 Japanese multicenter AF registries: the Atrial Fibrillation registry to Follow the long-teRm Outcomes and use of aNTIcoagulants aftER Ablation (AF Frontier Ablation Registry) as the ablation group (525 patients who underwent ablation) and the Hokuriku-Plus AF Registry as the medical therapy group (374 patients who did not undergo ablation). Propensity score matching was performed in these 2 registries to yield 106 matched patient pairs. The primary endpoint was a composite of cardiovascular death and hospitalization for heart failure. At 24.6 months, the ablation group had a significantly lower incidence of the primary endpoint (hazard ratio 0.32; 95% confidence interval 0.13-0.70; P=0.004) than the medical therapy group. CONCLUSIONS: Compared with medical therapy, catheter ablation for AF in patients with heart failure and mid-range or preserved EF was associated with a significantly lower incidence of cardiovascular death or hospitalization for heart failure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Humanos , Masculino , Idoso , Feminino , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Volume Sistólico , Resultado do Tratamento , Insuficiência Cardíaca/terapia , Ablação por Cateter/efeitos adversos , Sistema de Registros
6.
Heart Vessels ; 38(9): 1138-1148, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37029248

RESUMO

This study aimed to assess the predictors of spontaneous echocardiographic contrast (SEC) using left atrial appendage (LAA) findings in cardiac computed tomography (CT) of patients with atrial fibrillation (AF). We retrospectively analyzed cardiac CT findings of the LAA, including morphology, volume, and filling defects, of 641 patients who underwent transesophageal echocardiography (TEE) prior to pulmonary vein isolation (PVI) from January 6, 2013 through December 16, 2019 at our institution. We investigated potential associated factors that might be predictors of SEC using cardiac CT findings and computed a receiver operator characteristic, choosing a threshold value at which the likelihood of SEC could be predicted based on the LAA volume indexed for body size. SEC correlated significantly with indexed LAA volume (P < 0.001; odds ratio [OR], 1.31; 95% confidence interval [CI], 1.17-1.48) of 7.75 cm3/m2 or greater (sensitivity, 76.0%; specificity, 57.7%), LAA early filling defect (P = 0.005; OR, 2.72; 95% CI, 1.35-5.48), a history of persistent AF (P < 0.001; OR, 3.81; 95% CI, 1.86-7.80), and LAA flow velocity (P < 0.001; OR, 0.97; 95% CI, 0.96-0.99). Findings of LAA in cardiac CT can allow for the noninvasive estimation of SEC to determine the need for additional TEE investigation and the need to obtain additional information for risk stratification and management of thromboembolic events in patients with AF.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Ecocardiografia , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Ecocardiografia Transesofagiana , Masculino , Feminino , Pessoa de Meia-Idade , Idoso
7.
Heart Vessels ; 38(3): 413-421, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36194289

RESUMO

The "pre-freezing" technique was a method in which a fully inflated balloon after the start of freezing was pressed against the pulmonary vein (PV) during cryoballoon ablation and has been applied especially in large-size PVs. Of 556 patients who underwent cryoballoon ablation for atrial fibrillation (AF), the pre-freezing technique was applied to 48 patients. The resulting 2:1 propensity score-matched data set included 120 patients. Using the pre-freezing technique, all left-superior PVs, all left-inferior PVs, and 95% of right-superior PVs were successfully isolated. In most right-inferior PVs, complete sealing using the pre-freezing technique was challenging, and this technique was not applied. Procedure time was similar between the two groups. In the pre-freezing group, the percentage of the left atrial posterior wall isolated was larger (47.6 ± 10.3 vs. 42.8 ± 15.7%, P = 0.006), and the postoperative reduction of diaphragmatic compound motor action potentials tended to occur less frequently (2.5 vs. 12.5%, P = 0.07), and the reduction of the cross-sectional LSPV area was smaller (17.5 ± 12.2 vs. 27.2 ± 19.8%, P = 0.03) than the conventional group. The AF-free rate of the two groups was similar between the two groups (P = 0.15). The pre-freezing technique was a simple method that can isolate a wider surface area during cryoballoon PV isolation. While the postoperative AF recurrence was comparable, the postoperative reduction in the cross-sectional PV area was less than that of the conventional method, which may reduce the risk of PV stenosis.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Congelamento , Estudos Transversais , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento
8.
J Cardiovasc Electrophysiol ; 33(9): 2100-2103, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35842800

RESUMO

INTRODUCTION: Catheter ablation for atrial fibrillation (AF) in patients with tachycardia-bradycardia syndrome (TBS) can be a major therapeutic option to replace permanent pacemaker implantation (PMI). However, the very long-term outcome of more than 15 years in these patients has not been elucidated. METHODS: From 2002 to 2008, 25 consecutive TBS patients (62 ± 7.9 years old, 68% male) with both AF and symptomatic sinus pauses (>3.0 s) were performed radiofrequency AF ablation. These patients were followed for 15 ± 2.7 years. RESULTS: The median longest sinus pause before the ablation procedure was 6.0 s (4.4-8.0). Following 1.6± 0.8 ablation procedures, 18 (72%) patients remained free from AF. Three (12%) patients died due to noncardiovascular causes, and seven (28%) patients underwent PMI due to symptomatic sinus pause after recurrent AF in five patients and progression of sinus node dysfunction in two patients. The median duration from the first AF ablation to PMI was 6.3 years (range: 9 days to 11.0 years). Five and two patients required PMI more than 5 and 10 years after the first ablation procedure, respectively. CONCLUSION: AF ablation prevented PMI in 72% of TBS patients for a 15-year follow-up. However, in consideration of the long duration of PMI, a continuous careful long-term follow-up was warranted.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Bradicardia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Síndrome do Nó Sinusal/terapia , Taquicardia/diagnóstico , Taquicardia/cirurgia , Resultado do Tratamento
9.
Europace ; 24(11): 1769-1776, 2022 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-35851606

RESUMO

AIMS: The efficacy of left atrial posterior wall isolation (PWI) is controversial. Lesion durability may be a major cause of arrhythmia recurrence. The use of the lesion size prediction module improves lesion durability. This study aimed to compare the clinical outcomes of pulmonary vein isolation (PVI) alone and PWI in addition to PVI (PVI + PWI) in patients with non-paroxysmal atrial fibrillation (AF) using a lesion size prediction module. METHODS AND RESULTS: This study is a sub-analysis of the recently published prospective multicentre observational study called ALCOHOL-AF (association of alcohol consumption with outcome of catheter ablation of AF). In this sub-analysis, patients with non-paroxysmal AF in whom PVI alone or PVI + PWI was performed using the lesion size prediction module were included. Freedom from atrial tachyarrhythmia was compared between PVI alone and PVI + PWI groups using propensity score analyses. Of the 3474 patients registered in the ALCOHOL-AF study, 572 patients (age 65.6 ± 10.1 years, male 77.4%, longstanding persistent AF 25.5%) were included in this sub-analysis. We selected 212 patients treated with PVI alone and 212 treated with PVI + PWI using one-to-one propensity score matching. During the follow-up period, atrial tachyarrhythmia recurrence was documented in 92 (43.4%) and 50 (23.6%) patients in the PVI alone and PVI + PWI groups, respectively. Freedom from atrial tachyarrhythmia recurrence without anti-arrhythmic drugs after a single procedure was significantly higher in PVI + PWI than in PVI alone groups (hazard ratio: 0.452, 95% confidence interval: 0.308-0.664, P < 0.001). CONCLUSION: In this hypothesis-generating study, lesion size prediction module-guided PVI + PWI was associated with better clinical outcomes than PVI alone in patients with persistent or longstanding persistent AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Resultado do Tratamento , Átrios do Coração/cirurgia , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
10.
Circ J ; 87(1): 65-73, 2022 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-36130909

RESUMO

BACKGROUND: Radiofrequency hotballoon (RHB) is an ablation device used for atrial fibrillation (AF) treatment. The efficacy and safety of RHB-based pulmonary vein isolation (PVI) in real-world practice are unknown.Methods and Results: A multicenter, prospective registry study (UMIN000029567) enrolled AF patients who underwent RHB-PVI. The primary endpoint was the AF recurrence-free survival rate at 12 months after PVI. Of the 679 patients enrolled, 613 (90.3%; paroxysmal AF, n=370; persistent AF, n=136; long-standing AF, n=107) underwent initial RHB-PVI. Acute isolation using only the RHB was successful for 55.6% of patients and 83.5% of pulmonary veins (PVs). The acute isolation rate was higher for patients with paroxysmal AF and more experienced centers. Antiarrhythmic drugs were prescribed after 3 months for 47.5% of patients. The AF recurrence-free survival rate at 12 months was 83.7%. Procedure-related complications including atrio-esophageal fistula (n=1) and phrenic nerve injury (persistent; n=4, permanent; n=2) were observed in 19 (3.1%) patients. Five (1.7%) of the 302 patients who underwent pre-procedural and post-procedural multidetector computed tomography had severe PV stenosis. CONCLUSIONS: The size-adjustable RHB has been used for the treatment of various AF types. The arrhythmia recurrence-free rate at 12 months, with the use of antiarrhythmic drugs in approximately half of the patients, was acceptable, but the acute isolation rate using the RHB requires further improvement.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Antiarrítmicos/uso terapêutico , Estudos Prospectivos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
11.
Circ J ; 86(8): 1229-1236, 2022 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-35786690

RESUMO

BACKGROUND: Pulmonary vein (PV) stenosis after atrial fibrillation (AF) ablation is rare; however, it remains a serious complication. PV angioplasty is reportedly an effective therapy; however, a dedicated device for PV angioplasty has not been developed, and the detailed procedural methods remain undetermined. This study describes the symptoms, indications, treatment strategies, and long-term outcomes for PV stenosis after AF ablation.Methods and Results: This study retrospectively analyzed 7 patients with PV stenosis after catheter ablation for AF and who had undergone PV angioplasty at our hospital during 2015-2021. PV stenosis occurred in the left superior (5 patients) and left inferior (2 patients) PV. Six patients had hemoptysis, chest pain, and dyspnea. Seven de novo lesions were treated using balloon angioplasty (BA) (3 patients), a bare metal stent (BMS) (3 patients), and a drug-coated balloon (DCB) (1 patient). The restenosis rate was 42.9% (n=3; 2 patients in the BA group and 1 patient in the DCB group). The repeat treatment rate was 28.6% (2 patients in the BA group). Stenting was performed as repeat treatment. One patient with subsequent repeat restenosis development underwent BA. Ten PV angioplasties were performed; there were no major complications. CONCLUSIONS: Regarding PV angioplasty after ablation therapy for AF, stenting showed superior long-term PV patency than BA alone; therefore, it should be considered as a standard first-line approach.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Estenose de Veia Pulmonar , Angioplastia/efeitos adversos , Angioplastia/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Constrição Patológica/complicações , Humanos , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Estenose de Veia Pulmonar/diagnóstico por imagem , Estenose de Veia Pulmonar/etiologia , Estenose de Veia Pulmonar/terapia , Resultado do Tratamento
12.
Circ J ; 86(2): 233-242, 2022 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-34219078

RESUMO

BACKGROUND: It is unclear whether there are differences in the clinical factors between atrial fibrillation (AF) recurrence and adverse clinical events (AEs), including stroke/transient ischemic attack (TIA), major bleeding, and death, after AF ablation.Methods and Results:We examined the data from a retrospective multicenter Japanese registry conducted at 24 cardiovascular centers between 2011 and 2017. Of the 3,451 patients (74.1% men; 63.3±10.3 years) who underwent AF ablation, 1,046 (30.3%) had AF recurrence and 224 (6.5%) suffered AEs (51 strokes/TIAs, 71 major bleeding events, and 36 deaths) over a median follow-up of 20.7 months. After multivariate adjustment, female sex, persistent and long-lasting persistent AF (vs. paroxysmal AF), and stepwise increased left atrial diameter (LAd) quartiles were significantly associated with post-ablation recurrences. A multivariate analysis revealed that an age ≥75 years (vs. <65 years), body weight <50 kg, diabetes, vascular disease, left ventricular (LV) ejection fraction <40% (vs. ≥50%), Lad ≥44 mm (vs. <36 mm), and creatinine clearance <50 mL/min were independently associated with AE incidences, but not with recurrences. CONCLUSIONS: This study disclosed different determinants of post-ablation recurrence and AEs. Female sex, persistent AF, and enlarged LAd were determinants of post-ablation recurrence, whereas an old age, comorbidities, and LV and renal dysfunction rather than post-ablation recurrence were AEs determinants. These findings will help determine ablation indications and post-ablation management.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Ataque Isquêmico Transitório , Acidente Vascular Cerebral , Idoso , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Hemorragia/etiologia , Humanos , Ataque Isquêmico Transitório/etiologia , Masculino , Recidiva , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
13.
Heart Vessels ; 37(8): 1436-1445, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35178607

RESUMO

The reduction in flow velocity within the left atrial appendage (LAAFV) is associated with a high risk of thromboembolic events. There has been few reports using sufficient sample size about the relationship between LAAFV reduction and LAA features on cardiac computed tomography (CT), including LAA volume and filling defects, in patients with atrial fibrillation (AF). We evaluated the predictors of reduced flow velocity within the LAA using the findings of cardiac CT in patients with AF. We retrospectively analysed the cardiac CT findings of the LAA of 440 patients who underwent transoesophageal echocardiography prior to pulmonary vein isolation between 12 February, 2013 and 16 December, 2019 at our institution. We investigated the potential predictors of reduced LAAFV and the difference in LAAFV between the different morphological types of the LAA. The reduced flow velocity within the LAA was significantly correlated with higher CHADS2 scores [P = 0.001; odds ratio (OR), 1.52; 95% confidence interval (CI), 1.18-1.95], early filling defect in the LAA (P = 0.001; OR, 3.36; 95% CI 1.63-6.93), and increased indexed LAA volume (P = 0.036; OR, 1.09; 95% CI 1.01-1.19). The LAA morphological type and AF type were not significant predictors of the LAAFV reduction. Increased LAA volume, early filling defects in the LAA, and higher CHADS2 scores were independent predictors of LAAFV reduction in patients with AF. Our findings suggest that cardiac CT findings might allow non-invasive estimation of reduced LAAFV. These CT-derived parameters may provide additional information for the risk stratification and management of thromboembolic events in patients with AF.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Tromboembolia , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Velocidade do Fluxo Sanguíneo , Ecocardiografia Transesofagiana , Humanos , Estudos Retrospectivos , Fatores de Risco , Tromboembolia/complicações , Tromboembolia/prevenção & controle , Tomografia Computadorizada por Raios X/métodos
14.
Heart Vessels ; 37(1): 110-114, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34216250

RESUMO

The temporal changes in ambulatory monitoring findings after cryoballoon (CB) ablation of atrial fibrillation (AF) have not been well elucidated. This study aims to compare the details of ambulatory monitoring after CB and radiofrequency catheter (RFC) ablation for AF. Of 724 consecutive AF patients who underwent initial ablation using a CB or RFC, 508 (254 pairs) were selected using propensity score matching. Ambulatory monitoring was performed at 1, 3, 6, 12, 24 and 36 months after the procedure. After 1, 3 and 6 months, the number of total heart beats (THBs) was larger in the CB group than in the RFC group. It gradually decreased and became significantly similar by 12 months after ablation. THBs significantly increased 1, 3, 6 and 12 months after ablation in both the RFC and CB groups and became statistically similar by 24 months after ablation. The atrial premature contraction burden was higher in the RFC group than in the CB group at 3 months after ablation. THB and APC burden after AF ablation were significantly different between the RF and CB groups. THBs returned to statistically similarity by 2 years after ablation in both groups.


Assuntos
Fibrilação Atrial , Complexos Atriais Prematuros , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Complexos Atriais Prematuros/diagnóstico , Criocirurgia/efeitos adversos , Frequência Cardíaca , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
15.
Heart Vessels ; 37(2): 327-336, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34524497

RESUMO

The impact of catheter ablation for atrial fibrillation (AF) on cardiovascular events and mortality is controversial. We investigated the impact of sinus rhythm maintenance on major adverse cardiac and cerebrovascular events after AF ablation from a Japanese multicenter cohort of AF ablation. We investigated 3326 consecutive patients (25.8% female, mean age 63.3 ± 10.3 years) who underwent catheter ablation for AF from the atrial fibrillation registry to follow the long-term outcomes and use of anti coagulants after ablation (AF frontier ablation registry). The primary endpoint was a composite of stroke, transient ischemic attack, cardiovascular events, and all-cause death. During a mean follow-up of 24.0 months, 2339 (70.3%) patients were free from AF after catheter ablation, and the primary composite endpoint occurred in 144 (4.3%) patients. The AF nonrecurrence group had a significantly lower incidence of the primary endpoint (1.8 per 100 person-years) compared with the AF recurrence group (3.0 per 100 person-years, p = 0.003). The multivariate analysis revealed that freedom from AF (hazard ratio 0.61, 95% confidence interval 0.44-0.86, p = 0.005) was independently associated with the incidence of the composite event. In the multicenter cohort of AF ablation, sinus rhythm maintenance after catheter ablation was independently associated with lower rates of major adverse cardiac and cerebrovascular events.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Acidente Vascular Cerebral , Idoso , Fibrilação Atrial/complicações , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Sistema de Registros , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
16.
Circ J ; 85(8): 1314-1320, 2021 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-33883380

RESUMO

BACKGROUND: SATAKE HotBalloon®catheter (HBC) is a radiofrequency balloon catheter for the treatment of atrial fibrillation (AF), and was approved for use in Japan to treat drug-resistant paroxysmal AF in 2015. Post-marketing surveillance study was conducted by Toray Industries, Inc. to evaluate the efficacy and safety of HBC treatment in patients with paroxysmal AF in a real-world setting. This study is the first nation-wide survey of HBC treatment for paroxysmal AF in clinical practice in Japan.Methods and Results:This was a single-arm, multicenter observational study with an observation period of 48 weeks after ablation. Pulmonary vein isolation and AF non-recurrence rates were evaluated and adverse events (AEs) were observed at 46 sites in Japan. An AF event was defined as recurrence of AF or re-ablation from 12 to 48 weeks after ablation. The success rate of pulmonary vein isolation was 99.0% (486/491) for patients with AF. The cumulative AF non-recurrence rate was 94.1% at 24 weeks and 87.8% at 48 weeks. AEs were found to occur 21.5% (114/530), and ablation-related AEs were found to occur 2.6% (14/530) during the study period, with the most common being pericardial effusion (0.8%, 4/530). CONCLUSIONS: This study demonstrates the efficacy and safety of HBC ablation in Japanese patients with recurrent symptomatic paroxysmal AF refractory to antiarrhythmic therapy.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Catéteres , Humanos , Vigilância de Produtos Comercializados , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
17.
Heart Vessels ; 36(4): 549-560, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33236221

RESUMO

Whether ablation for atrial fibrillation (AF) is, in terms of clinical outcomes, beneficial for Japanese patients has not been clarified. Drawing data from 2 Japanese AF registries (AF Frontier Ablation Registry and SAKURA AF Registry), we compared the incidence of clinically relevant events (CREs), including stroke/transient ischemic attack (TIA), major bleeding, cardiovascular events, and death, between patients who underwent ablation (n = 3451) and those who did not (n = 2930). We also compared propensity-score matched patients (n = 1414 in each group). In propensity-scored patients who underwent ablation and those who did not, mean follow-up times were 27.2 and 35.8 months, respectively. Annualized rates for stroke/TIA (1.04 vs. 1.06%), major bleeding (1.44 vs. 1.20%), cardiovascular events (2.15 vs. 2.49%) were similar (P = 0.96, 0.39, and 0.35, respectively), but annualized death rates were lower in the ablation group than in the non-ablation group (0.75 vs.1.28%, P = 0.028). After multivariate adjustment, the risk of CREs was statistically equivalent between the ablation and non-ablation groups (hazard ratio [HR] 0.89, 95% confidence interval [CI] 0.71-1.11), but it was significantly low among patients who underwent ablation for paroxysmal AF (HR 0.68 [vs. persistent AF], 95% CI 0.49-0.94) and had a CHA2DS2-VASc score < 3 (HR 0.66 [vs. CHA2DS2-VASc score ≥ 3], 95% CI 0.43-0.98]). The 2-year risk reduction achieved by ablation may be small among Japanese patients, but AF ablation may benefit those with paroxysmal AF and a CHA2DS2-VASc score < 3.


Assuntos
Anticoagulantes/uso terapêutico , Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Pontuação de Propensão , Sistema de Registros , Medição de Risco/métodos , Acidente Vascular Cerebral/prevenção & controle , Idoso , Fibrilação Atrial/complicações , Feminino , Seguimentos , Humanos , Incidência , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Recidiva , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento
18.
J Cardiovasc Electrophysiol ; 31(8): 2222-2225, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32608049

RESUMO

We present a case of a 67-year-old female with a previous history of pulmonary vein isolation for paroxysmal atrial fibrillation who presented with supraventricular bigeminy with a constant coupling interval. The supraventricular bigeminy originated from the anterior mitral annulus with initial mapping suggestive of a focal mechanism. However detailed mapping using an ultrahigh resolution mapping system (with the manual shifting of the annotation window) revealed very low amplitude potentials connecting the previous sinus beat with continuous activation along the mitral annulus. Our observations were indicative of a re-entry mechanism underlying the supraventricular bigeminy.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Feminino , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Veias Pulmonares/cirurgia
19.
Int Heart J ; 61(6): 1165-1173, 2020 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-33191353

RESUMO

Direct oral anticoagulants (DOACs) are sometimes prescribed at off-label under-doses for patients who have undergone ablation for atrial fibrillation (AF). This practice may be an attempt to balance the risk of bleeding against that of stroke or AF recurrence.We examined outcomes of 1163 patients who continued use of a DOAC after ablation. The patients were enrolled in a large (3530 patients) multicenter registry in Japan. The study patients were classified as 749 (64.4%) appropriate standard-dose DOAC users, 216 (18.6%) off-label under-dose DOAC users, and 198 (17.0%) appropriate low-dose DOAC users.Age and CHA2DS2-VASc scores differed significantly between DOAC dosing regimens, with patients given an appropriate standard-dose being significantly younger (63.3 ± 9.4 versus 64.8 ± 9.5 versus 73.2 ± 6.8 years, P < 0.0001) and lower (2.1 ± 1.5 versus 2.4 ± 1.6 versus 3.4 ± 1.4, P < 0.0001) than those given an off-label under-dose or an appropriate low-dose. During the median 19.0-month follow-up period, the AF recurrence rate was similar between the appropriate standard-dose and off-label under-dose groups but relatively low in the appropriate low-dose group (42.5% versus 41.2% versus 35.4%, P = 0.08). Annualized rates of thromboembolic events, major bleeding, and death from any cause were 0.47%, 0.70%, and 0.23% in the off-label under-dose group, while those rates were 0.74%, 0.73%, and 0.65% in the appropriate standard-dose, and 1.58%, 2.12%, and 1.57% in the appropriate low-dose groups.In conclusion, the clinical adverse event rates for patients on an off-label under-dose DOAC regimen after ablation, predicated on careful patient evaluations, was not high as seen with that of patients on a standard DOAC dosing regimen.


Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter , Inibidores do Fator Xa/administração & dosagem , Hemorragia/induzido quimicamente , Acidente Vascular Cerebral/prevenção & controle , Tromboembolia/prevenção & controle , Idoso , Fibrilação Atrial/complicações , Feminino , Hemorragia/epidemiologia , Humanos , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Mortalidade , Uso Off-Label , Cuidados Pós-Operatórios , Recidiva , Sistema de Registros , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Tromboembolia/epidemiologia , Tromboembolia/etiologia
20.
J Cardiovasc Electrophysiol ; 30(11): 2310-2318, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31452290

RESUMO

BACKGROUND: The presence of heart failure (HF) has been associated with poorer outcomes in patients undergoing catheter ablation (CA) for atrial fibrillation (AF). However, the effectiveness of CA amongst the subset of patients with tachycardia-induced cardiomyopathy (TIC) remains poorly defined. METHODS AND RESULTS: In a retrospective analysis we compared outcomes of first-time CA for persistent AF in a cohort of patients with previously diagnosed TIC (n = 45; age 58 ± 8 years; 91% male) to those with structurally normal hearts (non-TIC; n = 440; age 55 ± 9 years; 95% male). TIC was defined as an impaired ventricular function (left ventricular ejection function [LVEF] <50%), which was reversed after the treatment of HF. We compared atrial arrhythmias (AAs) recurrence after the CA in the TIC and non-TIC cohorts. In the TIC group, LVEF improved from 35.8% ± 8.1% to 57.5% ± 8.3% after treatment of HF. During 3.3 ± 1.5 years follow-up, AAs-free survival after CA was significantly higher in the TIC group as compared with the non-TIC group (69% vs 42%; P = .001), despite a comparable CA strategy between the two groups. In multivariable analysis, absence of HF with TIC, longer AF duration, and complex fractionated atrial electrogram ablation were independent predictors of arrhythmia recurrence (OR, 1.02; 95% CI, 1.01-1.03; P < .01; OR, 0.40; 95% CI, 0.20-0.79; P < .01 and OR, 2.29; 95%CI; 1.27-4.11; P < .01, respectively). In addition, the outcome after the last procedure was superior in the TIC cohort (89% vs 72%; P = .03) with fewer CA procedures as compared with the non-TIC cohort (1.3 ± 0.5 vs 1.5 ± 0.7; P = .01). CONCLUSIONS: Persistent patients with AF with TIC have a more favorable outcome after the CA as compared with those without.


Assuntos
Fibrilação Atrial/cirurgia , Cardiomiopatias/etiologia , Ablação por Cateter , Potenciais de Ação , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Recidiva , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA