Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Anal Chem ; 93(17): 6599-6603, 2021 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-33871967

RESUMO

Due to the widespread use of dinotefuran around the world, its impact on food and environmental safety has aroused great concern, and the establishment of a rapid and convenient approach for dinotefuran detection is necessary but challenging. Herein, we synthesized a unique three-dimensional framework {[(CH3)2NH2]2[Cd3(BCP)2]·10H2O·3.5DMF}n (1). Single-crystal X-ray analysis indicates that 1 possesses a 4,8-connected anion framework that corresponds to alb topology, with a one-dimensional rectangular channel along the c-axis with the size of 4 Å × 10 Å. Compound 1 displays satisfactory solvent and thermal stability. Luminescent investigations reveal that 1 can selectively detect dinotefuran by fluorescence quenching among other pesticides, displaying excellent anti-interference performance with common ions in water. Importantly, the limit of detection is as low as 2.09 ppm, which is far below the residual concentration of the U.S. food standard. A fluorescence quenching mechanism study shows that there exists competitive energy absorption and static quenching processes. To our knowledge, 1 is the first MOF-based fluorescence probe for dinotefuran detection.


Assuntos
Luminescência , Estruturas Metalorgânicas , Cádmio , Guanidinas , Neonicotinoides , Nitrocompostos , Água
2.
Anal Chem ; 91(4): 2595-2599, 2019 02 19.
Artigo em Inglês | MEDLINE | ID: mdl-30712345

RESUMO

A novel 3D metal-organic framework (MOF){[Tb3(CBA)2(HCOO)(µ3-OH)4(H2O)]·2H2O·0.5DMF} n (S-1) was synthesized by the solvothermal method. The crystal structure indicates that [Tb4O4] cubane clusters self-assemble into an infinite chain by sharing vertex, which is further linked to adjacent chains through 1,1-cyclobutanedicarboxylic acid ligand (H2CBA), resulting in a honeycomb arrayed framework. S-1 possesses excellent water stability and still retains intact structure after exposure to water for 10 weeks or boiling water for 10 weeks. Interestingly, S-1 acts as a luminescence sensor to selectively and sensitively detect quercetin with the limit of detection (LOD) as low as 0.23 ppm (7.6 × 10-7 M). The relationship between relative luminescence intensity and concentration obeys linear in the range of 0-300 ppm (0-993 µM), which allows quantitative detection of quercetin. Importantly, S-1 can be reused at least six times with almost no change in luminescent intensity. Compared with the high performance liquid chromatography-mass spectrometry (HPLC-MS) method, S-1 was used to determine the content of quercetin in onionskin and apple peel samples with satisfactory results. Furthermore, a portable S-1 test paper is also developed and expected to be applied in practice. To our knowledge, S-1 is the first example of MOFs as luminescent sensor for quercetin.


Assuntos
Substâncias Luminescentes/química , Estruturas Metalorgânicas/química , Quercetina/análise , Reutilização de Equipamento , Limite de Detecção , Substâncias Luminescentes/síntese química , Medições Luminescentes/instrumentação , Medições Luminescentes/métodos , Malus/química , Estruturas Metalorgânicas/síntese química , Cebolas/química , Papel , Térbio/química
3.
Artigo em Inglês | MEDLINE | ID: mdl-17526427

RESUMO

In this paper, a novel method of constant energy synchronous fluorescence (CESF) was proposed to the simultaneous determination of different polycyclic aromatic hydrocarbons (PAHs) in a mixture of 16 components. When different appropriate intervals of the constant energy (Deltanu=1400 or 4800cm(-1)) were chosen during constant energy synchronous scanning, 13 PAHs could be identified and quantified by the corresponding synchronous spectra. Results show that their linear relations are fine and the limits of detection (LODs) were between 0.2 and 7.6ngml(-1). Then the application of CESF method proposed in the analysis of the real soil samples under the optimum conditions indicated that 11 PAHs could be identified and the total concentration of PAHs in a real soil sample is 5.1microg g(-1), most of PAHs in the soil samples had three or four rings. Recoveries of these PAHs were from 70.9 to 121.4% in most cases. This CESF method is a simple, rapid, sensitive method with high resolution and also suitable to analyze the complex mixtures of PAHs in other environmental samples.


Assuntos
Hidrocarbonetos Policíclicos Aromáticos/análise , Hidrocarbonetos Policíclicos Aromáticos/química , Solo/análise , Calibragem , Espectrometria de Fluorescência , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA