Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 35(7): 1401-1411, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38738814

RESUMO

INTRODUCTION: Ablation of scar-related reentrant atrial tachycardia (SRRAT) involves identification and ablation of a critical isthmus. A graph convolutional network (GCN) is a machine learning structure that is well-suited to analyze the irregularly-structured data obtained in mapping procedures and may be used to identify potential isthmuses. METHODS: Electroanatomic maps from 29 SRRATs were collected, and custom electrogram features assessing key tissue and wavefront properties were calculated for each point. Isthmuses were labeled off-line. Training data was used to determine the optimal GCN parameters and train the final model. Putative isthmus points were predicted in the training and test populations and grouped into proposed isthmus areas based on density and distance thresholds. The primary outcome was the distance between the centroids of the true and closest proposed isthmus areas. RESULTS: A total of 193 821 points were collected. Thirty isthmuses were detected in 29 tachycardias among 25 patients (median age 65.0, 5 women). The median (IQR) distance between true and the closest proposed isthmus area centroids was 8.2 (3.5, 14.4) mm in the training and 7.3 (2.8, 16.1) mm in the test group. The mean overlap in areas, measured by the Dice coefficient, was 11.5 ± 3.2% in the training group and 13.9 ± 4.6% in the test group. CONCLUSION: A GCN can be trained to identify isthmus areas in SRRATs and may help identify critical ablation targets.


Assuntos
Potenciais de Ação , Ablação por Cateter , Cicatriz , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Valor Preditivo dos Testes , Taquicardia Supraventricular , Humanos , Feminino , Masculino , Cicatriz/fisiopatologia , Cicatriz/diagnóstico , Pessoa de Meia-Idade , Idoso , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/cirurgia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiologia , Automação , Aprendizado de Máquina , Resultado do Tratamento , Processamento de Sinais Assistido por Computador
2.
Europace ; 26(7)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38812433

RESUMO

AIMS: Significant changes in tricuspid regurgitation (TR) and mitral regurgitation (MR) post-cardiac implantable electronic devices (CIEDs) are increasingly recognized. However, uncertainty remains as to whether the risk of CIED-associated TR and MR differs with right ventricular pacing (RVP) via CIED with trans-tricuspid RV leads, compared with cardiac resynchronization therapy (CRT), conduction system pacing (CSP), and leadless pacing (LP). The study aims to synthesize extant data on risk and prognosis of significant post-CIED TR and MR across pacing strategies. METHODS AND RESULTS: We searched PubMed, EMBASE, and Cochrane Library databases published until 31 October 2023. Significant post-CIED TR and MR were defined as ≥ moderate. Fifty-seven TR studies (n = 13 723 patients) and 90 MR studies (n = 14 387 patients) were included. For all CIED, the risk of post-CIED TR increased [pooled odds ratio (OR) = 2.46 and 95% CI = 1.88-3.22], while the risk of post-CIED MR reduced (OR = 0.74, 95% CI = 0.58-0.94) after 12 and 6 months of median follow-up, respectively. Right ventricular pacing via CIED with trans-tricuspid RV leads was associated with increased risk of post-CIED TR (OR = 4.54, 95% CI = 3.14-6.57) and post-CIED MR (OR = 2.24, 95% CI = 1.18-4.26). Binarily, CSP did not alter TR risk (OR = 0.37, 95% CI = 0.13-1.02), but significantly reduced MR (OR = 0.15, 95% CI = 0.03-0.62). Cardiac resynchronization therapy did not significantly change TR risk (OR = 1.09, 95% CI = 0.55-2.17), but significantly reduced MR with prevalence pre-CRT of 43%, decreasing post-CRT to 22% (OR = 0.49, 95% CI = 0.40-0.61). There was no significant association of LP with post-CIED TR (OR = 1.15, 95% CI = 0.83-1.59) or MR (OR = 1.31, 95% CI = 0.72-2.39). Cardiac implantable electronic device-associated TR was independently predictive of all-cause mortality [pooled hazard ratio (HR) = 1.64, 95% CI = 1.40-1.90] after median of 53 months. Mitral regurgitation persisting post-CRT independently predicted all-cause mortality (HR = 2.00, 95% CI = 1.57-2.55) after 38 months. CONCLUSION: Our findings suggest that, when possible, adoption of pacing strategies that avoid isolated trans-tricuspid RV leads may be beneficial in preventing incident or deteriorating atrioventricular valvular regurgitation and might reduce mortality.


Assuntos
Desfibriladores Implantáveis , Insuficiência da Valva Mitral , Marca-Passo Artificial , Insuficiência da Valva Tricúspide , Humanos , Estimulação Cardíaca Artificial/efeitos adversos , Terapia de Ressincronização Cardíaca/efeitos adversos , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Marca-Passo Artificial/efeitos adversos , Prognóstico , Fatores de Risco , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/mortalidade , Insuficiência da Valva Tricúspide/fisiopatologia
3.
Heart Rhythm ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38677360

RESUMO

BACKGROUND: Sinus rhythm activation time is useful to assess infarct border zone substrate. OBJECTIVE: We sought to further investigate sinus activation in ventricular tachycardia (VT). METHODS: Canine postinfarction data were analyzed retrospectively. In each experiment, an infarct was created in the left ventricular wall by left anterior descending coronary artery ligation. At 3 to 5 days after ligation, 196-312 bipolar electrograms were recorded from the anterior left ventricular epicardium overlapping the infarct border zone. Sustained monomorphic VT was induced by premature electrical stimulation in 50 experiments and was noninducible in 43 experiments. Acquired sinus rhythm and VT electrograms were marked for electrical activation time, and activation maps of representative sinus rhythm and VT cycles were constructed. The sinus rhythm activation signature was defined as the cumulative number of multielectrode recording sites that had activated per time epoch, and its derivative was used to predict VT inducibility and to define the sinus rhythm slow/late activation sequence. RESULTS: Plotting mean activation signature derivative, a best cutoff value was useful to separate experiments with reentrant VT inducibility (sensitivity, 42/50) vs noninducibility (specificity, 39/43), with an accuracy of 81 of 93. For the 50 experiments with inducible VT, recording sites overlying a segment of isochrone encompassing the sinus rhythm slow/late activation sequence spanned the VT isthmus location in 32 cases (64%), partially spanned it in 15 cases (30%), but did not span it in 3 cases (6%). CONCLUSION: The sinus rhythm activation signature derivative is assistive to differentiate substrate supporting reentrant VT inducibility vs noninducibility and to identify slow/late activation for targeting isthmus location.

4.
Heart Rhythm ; 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38848858

RESUMO

BACKGROUND: Where activation wavefront curvature is convexly shaped, functional conduction block can occur. OBJECTIVE: The purpose of this study was to determine whether left ventricular (LV) wall thickness determined from contrast-enhanced computed tomography (CT) is useful in localizing such areas in clinical postinfarction reentrant ventricular tachycardia (VT). METHODS: We evaluated data from 6 patients who underwent catheter ablation for postinfarction VT. CT imaging with inHEART processing was conducted 1-3 days before electrophysiological (EP) study to determine LV wall thickness (T). Activation wavefront curvature was approximated as ΔT/T, where ΔT represents wall thickness change. During EP study, bipolar LV VT electrograms were acquired using a high-density mapping catheter, and activation times were determined. Maps of T, ΔT/T, and VT activation were subsequently compared using statistical analyses. RESULTS: Two of 6 cases exhibited dual circuit morphologies, resulting in a total of 8 VT morphologies analyzed. The LV wall near the VT isthmus location tended to be thin, on the order of a few hundred micrometers. Regions of largest ΔT/T partially coincided with the lateral isthmus boundaries where electrical conduction block occurred during VT. ΔT/T at the boundaries, measured from imaging, was significantly larger compared to values at the isthmus midline and to the global LV mean value (P <.001). CONCLUSION: Wavefront curvature measured by ΔT/T and caused by source-sink mismatch is dependent on ventricular wall thickness. Areas of high wavefront curvature partly coincide with and may be helpful in locating the VT isthmus in infarct border zones using preprocedural imaging analysis.

5.
Heart Rhythm ; 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39094723

RESUMO

BACKGROUND: Atrial fibrillation (AF) is commonly associated with cardiac structural abnormalities including mitral regurgitation (MR). Contemporary guidelines recommend consideration of early rhythm control strategies including catheter ablation (CA) for AF. However, the long-term efficacy of CA is highly variable across studies and patient populations, and the effect of coexisting MR on AF recurrence remains unclear. OBJECTIVES: Determine the impact of significant MR defined as ≥ moderate on AF recurrence rate following CA, and whether CA for AF is associated with significant changes in the severity of MR. METHODS: A systematic search of PubMed, EMBASE, Web of Science, and Cochrane databases for all English-language studies published till December 31, 2023 was performed. RESULTS: A total of 17 studies (N= 2624 patients) were retained for meta-analysis. The pooled recurrence proportion of AF post-CA in patients with baseline significant MR was 36% (95% CI 27 %-46%), compared to 27% (14%-41%) in patients without. The pooled hazard ratio (95% CI) for AF recurrence after CA in the presence of significant MR was 2.47 (1.52 - 4.01), p <0.001, Egger's test p-value =0.0583. The pooled proportion of patients who witnessed MR improvement to non-significant (i.e.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA