Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Int J Cancer ; 154(3): 530-537, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37815300

RESUMO

Several observational studies have reported an association between obesity and primary liver cancer (PLC), while the causality behind this association and the comparison of the risk effects of different obesity indicators on PLC remain unclear. In this study, we performed two-sample Mendelian randomization (MR) analyses to assess the associations of genetically determined liver fat, visceral adipose tissue (VAT), and body mass index (BMI) with the risk of PLC. The summary statistics of exposures were obtained from two genome-wide association studies (GWASs) based on the UK Biobank (UKB) imaging cohort and the Genetic Epidemiology Research on Adult Health and Aging (GERA) cohort. GWAS summary statistics for PLC were obtained from FinnGen consortium R7 release data, including 304 PLC cases and 218 488 controls. Inverse-variance weighted (IVW) was used as the primary analysis, and a series of sensitivity analyses were performed to further verify the robustness of these findings. IVW analysis highlighted a significant association of genetically determined liver fat (OR per SD increase: 7.14; 95% CI: 5.10-9.99; P = 2.35E-30) and VAT (OR per SD increase: 5.70; 95% CI: 1.32-24.72; P = .020) with PLC but not of BMI with PLC. The findings were further confirmed by a series of MR methods. No evidence of horizontal pleiotropy between these associations existed. Our study suggested that genetically determined liver fat and VAT rather than BMI were associated with an increased risk of PLC, which suggested that visceral fat distribution is more predictive of the clinical risk of PLC than common in vitro measures.


Assuntos
Estudo de Associação Genômica Ampla , Neoplasias Hepáticas , Adulto , Humanos , Análise da Randomização Mendeliana , Obesidade/complicações , Obesidade/genética , Neoplasias Hepáticas/etiologia , Neoplasias Hepáticas/genética , Polimorfismo de Nucleotídeo Único
2.
BMC Cancer ; 24(1): 985, 2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-39123182

RESUMO

BACKGROUND: In China, both percutaneous microwave/radiofrequency ablation liver partition plus portal vein embolization (PALPP) and transarterial chemoembolization (TACE) plus portal vein embolization (PVE) have been utilized in planned hepatectomy. However, there is a lack of comparative studies on the effectiveness of these two techniques for cases with insufficient future liver remnant (FLR). METHODS: Patients were categorized into either the PALPP group or the TACE + PVE group. Clinical data, including FLR growth rate, complications, secondary resection rate, and overall survival rate, were compared and analyzed for both groups retrospectively. RESULTS: Between December 2014 and October 2021, a total of 29 patients underwent TACE + PVE (n = 12) and PALPP (n = 17). In the TACE + PVE group, 7 patients successfully underwent two-stage hepatectomy, while in the PALPP group, 13 patients underwent the procedure (two-stage resection rate: 58.3% vs. 76.5%, P = 0.42). There were no significant differences in postoperative complications of one-stage procedures (11.8% vs. 8.3%, P > 0.05) and second-stage resection complication (0% vs. 46.2%, P = 0.05) between the TACE + PVE and PALPP groups. However, the PALPP group demonstrated a shorter time to FLR volume growth for second-stage resection (18.5 days vs. 66 days, P = 0.001) and KGR (58.5 ml/week vs. 7.7 ml/week, P = 0.001). CONCLUSIONS: Compared with TACE + PVE, PALPP results in a more significant increase in FLR volume and a higher rate of two-stage resection without increasing postoperative complications.


Assuntos
Carcinoma Hepatocelular , Quimioembolização Terapêutica , Hepatectomia , Neoplasias Hepáticas , Micro-Ondas , Veia Porta , Ablação por Radiofrequência , Humanos , Hepatectomia/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Neoplasias Hepáticas/terapia , Neoplasias Hepáticas/cirurgia , Quimioembolização Terapêutica/métodos , Ablação por Radiofrequência/métodos , Micro-Ondas/uso terapêutico , Estudos Retrospectivos , Carcinoma Hepatocelular/terapia , Carcinoma Hepatocelular/cirurgia , Idoso , Adulto , Fígado/cirurgia , Fígado/irrigação sanguínea , Embolização Terapêutica/métodos , Resultado do Tratamento , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Taxa de Sobrevida , China/epidemiologia , Terapia Combinada
3.
Mikrochim Acta ; 191(4): 172, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38433173

RESUMO

A novel molecularly imprinted nanomaterial (Eu (BTC)-MPS@MIP) was synthesized on the surface of silanized europium-based metal-organic frameworks (Eu (BTC)-MPS) using 1, 3, 5-benzotrioic acid (H3BTC) as a ligand. The resulting Eu (BTC)-MPS@MIP was applied to constructing a smartphone sensing platform for the sensitive and selective detection of clothianidin (CLT) in vegetables. The synthesized Eu (BTC)-MPS@MIP demonstrated the successful formation of a typical core-shell structure featuring a shell thickness of approximately 70 - 80 nm. The developed sensing platform based on Eu (BTC)-MPS@MIP exhibited sensitivity in CLT detection with a detection limit of 4 µg/L and a linear response in the range 0.01 - 10 mg/L at excitation and emission wavelengths of 365 nm and 617 nm, respectively. The fluorescence sensing platform displayed excellent specificity for CLT detection, as evidenced by a high imprinting factor of 3.1. This specificity is primarily attributed to the recognition sites in the molecularly imprinted polymer (MIP) layer. When applied to spiked vegetable samples, the recovery of CLT ranged from 78.9 to 102.0%, with relative standard deviation (RSD) values falling between 2.2 and 6.2%. The quenching mechanism of Eu (BTC)-MPS@MIP toward CLT can be attributed to the inner filter effect (IFE), resulting from the optimal spectral overlap between the absorption spectrum of CLT and the excitation spectra of Eu (BTC)-MPS@MIP. The proposed method has the potential for extension to the detection of other pesticides by replacing the MIP recognition probes.

4.
HPB (Oxford) ; 26(8): 1062-1071, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38830783

RESUMO

BACKGROUND: Postoperative complications are vital factors affecting the prognosis of patients with hepatocellular carcinoma (HCC), especially for complex hepatectomy. The present study aimed to compare perioperative complications between laparoscopic and robotic complex hepatectomy (LCH vs. RCH). METHODS: Patients with solitary HCC after complex hepatectomy were collected from a multicenter database. Propensity score-matched (PSM) analysis was adopted to control confounding bias. Multivariable analysis was performed to determine the prognostic factors. RESULTS: 436 patients were included. After PSM, 43 patients were included in both the LCH and RCH groups. The results showed that compared to LCH, RCH had lower rates of blood loss and transfusion, and lower postoperative 30-day and major morbidity, and post-hepatectomy liver failure (PHLF) (all P < 0.05). Additionally, the length of hospital stay was shorter in the RCH group (P = 0.026). Multivariable analysis showed RCH is an independent protective factor for reducing the 30-day morbidity, major morbidity and PHLF. CONCLUSION: RCH has advantages over LCH in the minimally invasive treatment of complex HCC, as it can reduce the incidence of postoperative morbidity. Therefore, RCH should be considered for patients with HCC who require complex hepatectomy.


Assuntos
Carcinoma Hepatocelular , Hepatectomia , Laparoscopia , Neoplasias Hepáticas , Complicações Pós-Operatórias , Pontuação de Propensão , Procedimentos Cirúrgicos Robóticos , Humanos , Carcinoma Hepatocelular/cirurgia , Hepatectomia/efeitos adversos , Hepatectomia/métodos , Neoplasias Hepáticas/cirurgia , Masculino , Laparoscopia/efeitos adversos , Feminino , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Resultado do Tratamento , Idoso , Bases de Dados Factuais , Tempo de Internação , Fatores de Risco , Fatores de Tempo , Medição de Risco , Adulto
5.
Anal Methods ; 16(16): 2569-2584, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38606427

RESUMO

The affinity sites of cadmium (Cd(II)) when binding to cysteine (Cys) and glutathione (GSH) were studied via thermodynamics and nuclear magnetic resonance (NMR) spectroscopy methods. The results showed that the Cd(II) binding sites of Cys and GSH were -SH (exothermic), -NH2 (endothermic) and -COOH (endothermic). The thermodynamic behaviour of Cd(II) binding to Cys/GSH in boric acid and HEPES buffers differed, with the former being mainly endothermic and the latter mainly exothermic. It could be inferred that, in the boric acid system, the main binding site of Cd(II) with Cys and GSH is changed from -SH in HEPES to -COOH and -NH2 in boric acid. This was confirmed by the results of NMR experiments of Cd(II) with Cys/GSH. 1D 1H-NMR experiments showed that, after the combination of Cd(II) and Cys, the changes in the chemical shifts and peak strengths of protons near the -SH group for the reaction in HEPES were greater than when boric acid buffer was used. Changes in the chemical shift and peak strength of the -NH2 protons due to the binding of Cd(II) to GSH were evident in the boric acid buffer but not in HEPES. The screening of functional monomers is very important in the process of preparation of cadmium ion-imprinted materials. This research provides important theoretical and experimental guidance for the screening of functional monomers.

6.
Sci Total Environ ; 928: 172422, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38614329

RESUMO

The oily wastewater and heavy metal ions have been increasingly discharged into water environment, posting a serious threat to ecosystems and human health. However, it remains challenging to use single separation technology to effectively remove oil and heavy metal ions in oil-water mixtures simultaneously. Herein, novel hydrophobic/hydrophilic composites (HHC) were successfully prepared by using A4 paper-derived hydrophilic cellulose as the modified matrix, modifying the polydopamine layer and in-situ growth nanoscale zero-valent iron as active adsorption materials, combined with oleic acid-modified hydrophobic magnetic hollow carbon microspheres, which were used to efficiently and rapidly adsorb heavy metals and oil in oil-water mixtures. Under the optimal adsorption conditions, the adsorption amounts of As(III), As(V), Pb(II) and Cu(II) were 289.6 mg/g, 341.9 mg/g, 241.2 mg/g and 277.5 mg/g, respectively, and the mass transfer rate of HHC to the target ions is fast. The HHC have efficient separation performance for layered oil-water mixtures and emulsified oil-water mixtures, with separation efficiency of 97 % and 92 %. At the same time, due to the abundant adsorption sites, the HHC also exhibit splendid regeneration performance for the four ions after multiple adsorption utilization. Our work designed a approach to achieving promising oil and heavy metal adsorbents with higher adsorption capacity and better regenerative properties.

7.
Biosens Bioelectron ; 251: 116127, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38382272

RESUMO

Owing to advantage in high sensitivity and fast response, aptamer based electrochemical biosensors have attracted much more attention. However, inappropriate interfacial engineering strategy leads to poor recognition performance, which ascribe to the following factors of immobilized oligonucleotide strand including steric hindrance, interchain entanglement, and unfavorable conformation. In this work, we proposed a DNA tetrahedron based diblock aptamer immobilized strategy for the construction of label-free electrochemical biosensor. The diblock aptamer sequence is composite of T-rich anchor domain and recognition domain, where T-rich domain enabling anchored on the edge of DNA tetrahedron via Hoogsteen hydrogen bond at neutral condition. The DNA tetrahedron scaffold offers an appropriate lateral space for target recognition of diblock aptamer. More importantly, this trivalent aptamer recognition interface can be regenerated by simply adjusting the pH environment to alkaline, resulting in the dissociation of diblock aptamer. Under the optimum condition, proposed electrochemical aptasensor manifested a satisfied sensitivity for aminoglycosides antibiotic, kanamycin with a limit of detection of 0.69 nM, which is 45-fold lower than traditional Au-S immobilization strategy. Moreover, the proposed aptasensor had also successfully been extended to ampicillin detection by changing the sequence of recognition domain in diblock aptamer. This work paves a new way for the rational design of aptamer-based electrochemical sensor.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Antibacterianos , Técnicas Biossensoriais/métodos , Aptâmeros de Nucleotídeos/química , DNA/química , Canamicina , Técnicas Eletroquímicas , Limite de Detecção , Ouro/química
8.
Spectrochim Acta A Mol Biomol Spectrosc ; 309: 123807, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38154306

RESUMO

Due to the threat of lead pollution to health, environmental and food safety, developing simple and fast detection methods is highly required. Whereas, traditional single-mode probe suffers from limited application scenario. In this study, a colorimetric and fluorometric dual-mode probe for Pb2+ determination was constructed by using bifunctional G-quadruplex-hemin complex. In this dual-mode probe, enzyme strand and substrate strand of 8-17 DNAzyme are labeled with G-quadruplex-hemin complex and fluorophore, respectively. In the absence of Pb2+, the self-assembly of enzyme strand and substrate strand inhibits intrinsic mimic peroxidase of G-quadruplex-hemin complex by base-pairing, which also quench the fluorescence via in proximity effect. When the DNAzyme is activated by Pb2+, the quenched fluorescence is restored as well as the inherent peroxidase mimetic activity, leading to dual signal output. Under optimal conditions, this dual-mode probe exhibit a good linear relationship between logarithm of Pb2+ concentration and signal difference within the range from 1.5 nM to 20 nM and 0.5 nM to 10 nM for colorimetric and fluorescence mode, respectively. The detection limits for the corresponding mode were estimated to be 1.29 nM and 0.16 nM, respectively. This dual-mode probe also successfully applied for the spiked river water assay with satisfactory recovery in the range of 93.2 %-115.3 %. This work paves a new way for DNAzyme based dual-mode probe construction.


Assuntos
Técnicas Biossensoriais , DNA Catalítico , Quadruplex G , Hemina , Chumbo , Colorimetria/métodos , Corantes , Peroxidases , Técnicas Biossensoriais/métodos
9.
Asian J Surg ; 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38724372

RESUMO

BACKGROUND AND AIMS: The prognosis of patients with hepatocellular carcinoma (HCC) undergoing hepatectomy is unsatisfactory, especially for those with microvascular invasion (MVI). This study aimed to determine the impact of adjuvant transcatheter arterial chemoembolization (TACE) and Lenvatinib on the prognosis of patients with HCC and MVI after hepatectomy. METHODS: Patients diagnosed with HCC and MVI were reviewed, and stratified into four groups according to adjuvant TACE and/or Lenvatinib. Multivariate Cox regression analyses are used to determine independent risk factors. RESULTS: 346 patients were included, and divided into four groups (Group I, TACE+ Lenvatinib; Group II, Lenvatinib; Group III, TACE; Group IV, without adjuvant therapy). Multivariable analysis showed that compared to Group IV, Group I had the best effect on improving the overall survival (OS, HR 0.321, 95%CI 0.099-0.406, P = 0.001) and recurrence-free survival (RFS, HR 0.319, 95%CI 0.129-0.372, P = 0.001). Additionally, compared with Group II or Group III, Group I also can significantly improve the OS and RFS. There is no significant difference between Group II and Group III in OS and RFS. CONCLUSION: The combination of TACE and Lenvatinib should be considered for anti-recurrence therapy for patients with HCC and MVI after hepatectomy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA