Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Radiat Environ Biophys ; 59(3): 357-387, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32372284

RESUMO

This work presents an overview of the applications of retrospective dosimetry techniques in case of incorporation of radionuclides. The fact that internal exposures are characterized by a spatially inhomogeneous irradiation of the body, which is potentially prolonged over large periods and variable over time, is particularly problematic for biological and electron paramagnetic resonance (EPR) dosimetry methods when compared with external exposures. The paper gives initially specific information about internal dosimetry methods, the most common cytogenetic techniques used in biological dosimetry and EPR dosimetry applied to tooth enamel. Based on real-case scenarios, dose estimates obtained from bioassay data as well as with biological and/or EPR dosimetry are compared and critically discussed. In most of the scenarios presented, concomitant external exposures were responsible for the greater portion of the received dose. As no assay is available which can discriminate between radiation of different types and different LETs on the basis of the type of damage induced, it is not possible to infer from these studies specific conclusions valid for incorporated radionuclides alone. The biological dosimetry assays and EPR techniques proved to be most applicable in cases when the radionuclides are almost homogeneously distributed in the body. No compelling evidence was obtained in other cases of extremely inhomogeneous distribution. Retrospective dosimetry needs to be optimized and further developed in order to be able to deal with real exposure cases, where a mixture of both external and internal exposures will be encountered most of the times.


Assuntos
Radiação Ionizante , Radiometria/métodos , Animais , Espectroscopia de Ressonância de Spin Eletrônica , Humanos , Radioisótopos/farmacocinética
2.
J Radiol Prot ; 35(2): R1-15, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25884230

RESUMO

In the event of a radiation emergency, people close to the site of the incident may be exposed to radiation by external exposure, or as a result of intakes of radioactive material. For these incidents it may be necessary to monitor members of the public both for external and internal contamination. This work reviews currently available equipment for the assessment of internal exposure following an emergency. It concentrates on incidents involving the spread of radioactive material and on contamination by radionuclides which emit penetrating radiation. It is essential that this monitoring is carried out as soon as possible so that people who have been exposed at a level which could have an effect on health can be identified and receive prompt medical assessment. Proposed action levels to identify people who need medical attention are reviewed to determine the required sensitivity of monitoring equipment. For releases containing gamma-ray emitting radionuclides the best means of measuring internal contamination is to use detectors placed close to the body (whole body or partial body monitoring). Laboratory based whole body monitors could be used but these may well be inconveniently located and so equipment which can be deployed to the site of an incident has been developed and these are described. The need for rapid selection and prioritisation of people for monitoring, methods to deal with potentially high numbers of contaminated people and the requirement for a means of rapidly interpreting monitoring information are also discussed.It has been found that for many types of incidents and scenarios, systems based on unshielded high-resolution detectors and hand-held instruments do have the required sensitivity to identify people who require medical assessment.


Assuntos
Serviços Médicos de Emergência/métodos , Lesões por Radiação/diagnóstico , Monitoramento de Radiação/instrumentação , Liberação Nociva de Radioativos , Triagem/métodos , Contagem Corporal Total/instrumentação , Emergências , Desenho de Equipamento , Humanos , Doses de Radiação , Lesões por Radiação/prevenção & controle , Monitoramento de Radiação/métodos , Contagem Corporal Total/métodos
3.
Exp Lung Res ; 37(2): 109-29, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21142810

RESUMO

Retention in the extrathoracic airways, and clearance by nose blowing, of monodisperse indium-111-labeled polystyrene particles were followed for at least 2 days after inhalation by healthy volunteers. Nine volunteers inhaled 3-µm aerodynamic diameter particles while sitting at rest, whereas subgroups of 3 or 4 inhaled 1.5-µm or 6-µm particles at rest, and 3-µm or 6-µm particles while performing light exercise. Retention of the initial extrathoracic deposit (IETD) in the extrathoracic airways was described by 4 components: on average 19% IETD cleared by nose blowing; 15% was swallowed before the first measurement, a few minutes after inhalation; 21% cleared by mucociliary action between the first measurement and about an hour later; and 45% subsequently cleared by mucociliary action. Geometric mean times in which 50% and 90% of IETD cleared were 2.5 and 22 hours. The geometric mean retention fractions at 24 and 48 hours were 7% and 2.4% IETD, respectively. No clear trends were found between parameters describing retention and any related to deposition (e.g., particle size). However, the fraction cleared by nose blowing was related to the frequency of nose blowing and therefore appears to be a characteristic of the individual.


Assuntos
Depuração Mucociliar/fisiologia , Mucosa Nasal/metabolismo , Poliestirenos/farmacocinética , Administração por Inalação , Adulto , Exercício Físico , Feminino , Humanos , Radioisótopos de Índio/química , Masculino , Tamanho da Partícula , Respiração
4.
Exp Lung Res ; 34(6): 287-312, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18600497

RESUMO

The Human Respiratory Tract Model of the International Commission on Radiological Protection assumes that a fraction of particles deposited in the bronchial tree clears slowly, this fraction decreasing with increasing particle geometric diameter. To test this assumption, volunteers inhaled 5-microm aerodynamic diameter 111In-polystyrene and 198Au-gold particles simultaneously, as a 'bolus' at the end of each breath to minimize alveolar deposition. Because of the different densities (1.05 versus 19.3 g cm3), geometric diameters were about 5 and 1.2 microm, respectively, and corresponding predicted slowly cleared fractions were about 10% and 50%. However, lung retention of the 2 particles was similar in each subject. Retention at 24 hours, as a percentage of initial lung deposit (mean +/- SD) was 34 +/- 12 for polystyrene and 31 +/- 11 for the gold particles.


Assuntos
Brônquios/metabolismo , Ouro/farmacocinética , Depuração Mucociliar/fisiologia , Tamanho da Partícula , Poliestirenos/farmacocinética , Administração por Inalação , Adulto , Aerossóis , Feminino , Ouro/administração & dosagem , Radioisótopos de Ouro , Humanos , Radioisótopos de Índio , Pulmão/metabolismo , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Poliestirenos/administração & dosagem
5.
Radiat Prot Dosimetry ; 127(1-4): 374-7, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18003709

RESUMO

In an emergency involving the deliberate or accidental release of radioactive materials, there could potentially be a large number of people who require monitoring for internal contamination. Doses from these measurements will need to be calculated as quickly as possible. Emergency Response Internal Dose Assessment Software (ERIDAS) has been designed for this purpose.


Assuntos
Bioensaio/métodos , Emergências , Modelos Biológicos , Liberação Nociva de Radioativos , Radiometria/métodos , Software , Carga Corporal (Radioterapia) , Simulação por Computador , Humanos , Doses de Radiação , Eficiência Biológica Relativa
6.
Radiat Prot Dosimetry ; 127(1-4): 35-9, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17827135

RESUMO

The ICRP human respiratory tract model (HRTM) assumes that the 'slow-cleared fraction' fs in the bronchial (BB) and bronchiolar (bb) regions decreases with increasing particle geometric diameter dp. To test this assumption, five volunteers inhaled 8-microm aerodynamic diameter, dae, (111)In-polystyrene (PSL) and (198)Au particles simultaneously. The particles were administered at the end of each breath to maximise deposition in BB and bb. Because of the difference in densities (1.05 vs. 19.3 g cm(-3)), corresponding dp values are approximately 8 and 1.8 microm, and fs values are approximately 2 and 50%, respectively. However, lung retention was somewhat greater for PSL than for gold, contrary to the HRTM prediction. Other recent human experimental studies found no difference in retention for particles with the same dae but different dp values. It is concluded that the HRTM model of particle clearance from BB and bb needs revision.


Assuntos
Aerossóis/farmacocinética , Exposição por Inalação/análise , Pulmão/metabolismo , Modelos Biológicos , Radioisótopos/análise , Radioisótopos/farmacocinética , Radiometria/métodos , Aerossóis/análise , Simulação por Computador , Humanos , Taxa de Depuração Metabólica , Especificidade de Órgãos , Tamanho da Partícula , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Appl Radiat Isot ; 64(10-11): 1242-7, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16549359

RESUMO

The National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) for seaweed was developed through an interlaboratory comparison with 24 participants from 16 countries. After evaluating different techniques to calculate certified values for the radionuclides, the median method was found to be the most representative technique. The certified values were provided for 13 radionuclides and information values were given for 15 more radionuclides. Results for the natural decay series showed disequilibrium in both the uranium and thorium series.


Assuntos
Guias como Assunto , Monitoramento de Radiação/normas , Radioisótopos/análise , Radioisótopos/normas , Padrões de Referência , Alga Marinha/química , Poluentes Radioativos da Água/análise , Cooperação Internacional , Doses de Radiação , Monitoramento de Radiação/métodos , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Poluentes Radioativos da Água/normas
8.
Curr Med Chem ; 6(3): 255-70, 1999 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10219102

RESUMO

Solid-phase organic synthesis, particularly when used in conjunction with combinatorial techniques, is emerging as a revolutionary technology in chemistry. Multi-component reaction systems are particularly valued because several elements of diversity can be introduced in a single transformation thereby expanding the diversity of compound libraries. A variety of multi-component reactions have been successfully adapted for solid-phase technology as described in this review.


Assuntos
Química Orgânica/métodos , Tecnologia Farmacêutica/tendências , Ciclização
9.
Talanta ; 48(5): 1203-6, 1999 May.
Artigo em Inglês | MEDLINE | ID: mdl-18967566

RESUMO

Microwave-assisted extraction (MAE) was examined as an alternative to the traditional Soxhlet method of extracting C(60) and C(70) from fullerene soot. MAE of 0.20 g of fullerene soot with 95:5 toluene-acetonitrile yielded greater than 7.8 mg of C(60) and greater than 0.54 mg of C(70) in 4 min with no further increase in yield after 30 min of irradiation. By comparison, exhaustive Soxhlet extraction of the same size sample with the same solvent yielded 7.1 mg of C(60) and 0.58 mg of C(70) in 340 min. Re-extraction by MAE of soot initially extracted by Soxhlet increased the yield of Soxhlet alone. Although MAE was limited to less than 0.5-g sample per extraction vessel, multiple samples were extracted with minimal increased extraction time and no reduction in the amount of material recovered.

10.
Br J Educ Psychol ; 69 ( Pt 2): 159-72, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10405617

RESUMO

BACKGROUND: Of the research that has been undertaken into the relationship between personality and attainment, relatively little exists relating to the 16-19 age range. In a substantive study examining the relationship between academic self-concept, attainment and personality in sixth form students, a first requirement was to design a self-perception instrument. AIMS: The psychometric element of the study aimed to construct a Student Self-Perception Scale (SSPS) that would be effective for students in the FE (further education) context. SAMPLES: The samples comprised a pilot sample of 152 students (aged 16-17 years from two sixth from colleges) and a main sample of 364 students (mean age, 16yrs 10mths, range 16:0 to 18:6 years, from one sixth form college). The main sample included similar numbers of male and female students (46% male, 54% female) and ethnic minority students comprised 14% of this sample. METHOD: An initial item pool of 88 four-point Likert type statements was compiled from comparable existing scales and from responses to a Student Induction Questionnaire. Item analysis was based on oblique factor analysis of the pilot sample responses, followed by cross-validation on the main sample to refine the scale structures. Construct validity was established from the substantive study, especially the Nowicki & Strickland (1973) locus of control results. RESULTS: Exploration of the four- and five-factor structures led to a final specification based on 52 items from five oblique factors. The constituent scales were Passivity (12 items, alpha = .81). Mastery (15 items, alpha = .79), Work Related Inadequacy (11 items, alpha = .72), Extraversion (4 items, alpha = .70) and Social Dependence (10 items, alpha = .66), all statistics compiled from the cross-validation sample. Correlations with Locus of Control ranged from 0.52 for Mastery to -.34 for Work Related Inadequacy. Distribution statistics for Locus of Control matched a comparable American sample. CONCLUSIONS: The five-scale structure exhibits good cross-validation characteristics and supports revealing analyses of relationships within the substantive study. Its 52-item format is suitable for research or exploratory use within its intended FE context.


Assuntos
Logro , Desenvolvimento da Personalidade , Inventário de Personalidade/estatística & dados numéricos , Autoimagem , Estudantes/psicologia , Adolescente , Adulto , Feminino , Humanos , Masculino , Projetos Piloto , Psicometria , Reprodutibilidade dos Testes
11.
Br J Educ Psychol ; 69 ( Pt 2): 173-87, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10405618

RESUMO

BACKGROUND: A related paper (Summerfield & Youngman, 1999) has described the development of a scale, the Student Self-Perception Scale (SSPS) designed to explore the relationship between academic self-concept, attainment and personality in sixth form college students. AIMS: The study aimed to identify groups of students exhibiting varying patterns of relationship using a range of measures including the SSPS. Issues of gender and also examined. SAMPLES: The samples comprised a pilot sample of 152 students (aged 16-17 years from two sixth form colleges) and a main sample of 364 students (mean age, 16 yrs 10 mths range 16:0 to 18:6 years, from one sixth form college). The main sample included similar numbers of male and female students (46% male, 54% female) and ethnic minority students comprised 14% of this sample. METHOD: Data comprised responses to two personality measures (the SSPS, Summerfield, 1995, and the Nowicki-Strickland Locus of Control Scale, Nowicki & Strickland, 1973), various student and tutor estimates of success, and performance data from college records. Students were classified using relocation cluster analysis and cluster differences verified using discriminant function analysis. Thirty outcome models were tested using covariance regression analysis. RESULTS: Eight distinct and interpretable groups, consistent with other research, were identified but the hypothesis of a positive, linear relationship between mastery and academic attainment was not sustained without qualification. Previous attainment was the major determinant of final performance. Gender variations were detected on the personality measures, particularly Confidence of outcomes, Prediction discrepancy, Passivity, Mastery, Dependency and Locus of control, and these were implicated in the cluster characteristics. CONCLUSIONS: The results suggest that a non-linear methodology may be required to isolate relationships between self-concept, personality and attainment, especially where gender effects may exist.


Assuntos
Logro , Identidade de Gênero , Desenvolvimento da Personalidade , Inventário de Personalidade/estatística & dados numéricos , Autoimagem , Estudantes/psicologia , Adolescente , Adulto , Feminino , Humanos , Masculino , Projetos Piloto , Psicometria , Reprodutibilidade dos Testes
12.
Radiat Prot Dosimetry ; 107(4): 259-67, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14756183

RESUMO

A transportable in vivo monitoring system has been constructed and calibrated. The system uses two hyper pure germanium detectors--one for measuring whole body activities, by measuring activity in the torso, and the second for determining activities of radioiodine in the thyroid. The optimum counting geometries have been determined and the system has been calibrated for subjects of different ages and builds. The complete system is transported in two trailers which are pulled by ordinary motor vehicles. The minimum detectable activity (MDA) for 137Cs in whole body for a 10 min counting interval at the 95% confidence level is 200 Bq. The MDA for a count of 131I in thyroid is 20 Bq. The system is capable of detecting activities that are equivalent to a dose of 1 mSv for a wide range of radionuclides.


Assuntos
Exposição Ambiental/análise , Monitorização Fisiológica/instrumentação , Proteção Radiológica/instrumentação , Liberação Nociva de Radioativos , Radiometria/instrumentação , Contagem Corporal Total/instrumentação , Carga Corporal (Radioterapia) , Calibragem/normas , Análise de Falha de Equipamento/métodos , Monitorização Fisiológica/métodos , Monitorização Fisiológica/normas , Doses de Radiação , Proteção Radiológica/normas , Radioisótopos/análise , Radioisótopos/farmacocinética , Radiometria/métodos , Radiometria/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Glândula Tireoide/metabolismo , Meios de Transporte , Contagem Corporal Total/normas
13.
Radiat Prot Dosimetry ; 105(1-4): 473-6, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14527011

RESUMO

In a nuclear weapon accident involving fire or conventional explosion, most of the radiation dose received by people in the immediate vicinity would result from inhalation of 239Pu. This is accompanied by the nuclide 241Am, which is much easier to determine by external counting because of the 60 keV gamma ray emission. In the event of an accident, a priority would be to identify any people who have had intakes of 239Pu which were so large that decorporation therapy should be considered. Direct measurement of lung content provides the most rapid and convenient method for assessing intakes by inhalation. A transportable system has been considered as this could be deployed close to the site of the accident and would allow rapid measurements to be made. The feasibility of a transportable 241Am-in-nose-blow and nasal swab measurement system has also been considered. This would be used to help select people for 241Am-in-lung measurements.


Assuntos
Amerício/análise , Amerício/farmacocinética , Serviços Médicos de Emergência/métodos , Pulmão/metabolismo , Proteção Radiológica/instrumentação , Radiometria/instrumentação , Mucosa Respiratória/metabolismo , Poluentes Radioativos do Ar/análise , Poluentes Radioativos do Ar/farmacocinética , Ambulâncias , Desenho de Equipamento , Estudos de Viabilidade , Humanos , Exposição por Inalação/análise , Monitorização Ambulatorial/instrumentação , Monitorização Ambulatorial/métodos , Mucosa Nasal/metabolismo , Guerra Nuclear , Doses de Radiação , Proteção Radiológica/métodos , Liberação Nociva de Radioativos , Radiometria/métodos , Sensibilidade e Especificidade , Triagem/métodos , Reino Unido
14.
Radiat Prot Dosimetry ; 105(1-4): 115-8, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14526939

RESUMO

The aim of this work was to investigate the biokinetics of thorium dioxide in animals for the purpose of assessing intakes of the compound by workers and the resulting doses. The results imply that measurements of the decay products in the chest or extrapolations from urine analysis data are unlikely to be of value for doses below 20 mSv. Even higher doses should be interpreted with caution as a consequence of uncertainties in particle size distribution and variations in dietary excretion.


Assuntos
Pulmão/metabolismo , Modelos Biológicos , Radiometria/métodos , Dióxido de Tório/análise , Dióxido de Tório/farmacocinética , Absorção , Administração por Inalação , Poluentes Radioativos do Ar/análise , Animais , Lavagem Broncoalveolar , Simulação por Computador , Feminino , Humanos , Exposição por Inalação/análise , Injeções Intravenosas , Taxa de Depuração Metabólica , Exposição Ocupacional/análise , Doses de Radiação , Ratos , Sistema Respiratório/metabolismo , Tórax/metabolismo , Dióxido de Tório/administração & dosagem , Urinálise
15.
Radiat Prot Dosimetry ; 105(1-4): 91-4, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14526934

RESUMO

The absorption kinetics to blood of plutonium and gadolinium after inhalation as nitrate and oxide in humans and animals has been studied. For each material, values describing the time dependence of absorption were derived from the studies in animals and used with the ICRP human respiratory tract model to predict lung retention and cumulative amounts to blood for the volunteers inhaling the same materials. Comparison with the observed behaviour in the volunteers suggests that absorption of plutonium and gadolinium is reasonably species independent, and that data obtained from animal studies can be used to assess their biokinetic behaviour in humans.


Assuntos
Gadolínio/farmacocinética , Pulmão/metabolismo , Modelos Biológicos , Nitratos/farmacocinética , Plutônio/farmacocinética , Radiometria/métodos , Especificidade da Espécie , Absorção , Administração por Inalação , Aerossóis , Animais , Simulação por Computador , Cães , Feminino , Gadolínio/administração & dosagem , Humanos , Nitratos/administração & dosagem , Especificidade de Órgãos , Plutônio/administração & dosagem , Doses de Radiação , Ratos
16.
Radiat Prot Dosimetry ; 144(1-4): 534-9, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21147786

RESUMO

The part played by individual monitoring within the context of the overall response to incidents involving the malevolent use of radiation or radioactive material is discussed. The main objectives of an individual monitoring programme are outlined, and types of malevolent use scenario briefly described. Some major challenges facing those with responsibilities for planning the monitoring response to such an incident are identified and discussed. These include the need for rapid selection and prioritisation of people for individual monitoring by means of an effective triage system; the need for rapid initiation of individual monitoring; problems associated with monitoring large numbers of people; the particular difficulties associated with incidents involving pure-beta and alpha-emitting radionuclides; the need for techniques that can provide retrospective estimates of external radiation exposures rapidly and the need for rapid interpretation of contamination monitoring data. The paper concludes with a brief review of assistance networks and relevant international projects planned or currently underway.


Assuntos
Lesões por Radiação/diagnóstico , Monitoramento de Radiação/métodos , Liberação Nociva de Radioativos , Radiometria/instrumentação , Triagem/métodos , Partículas alfa , Partículas beta , Aberrações Cromossômicas , Serviços Médicos de Emergência , Contaminação de Equipamentos , Desenho de Equipamento , Humanos , Hibridização in Situ Fluorescente , Cooperação Internacional , Cinética , Monitoramento de Radiação/instrumentação , Radiação Ionizante , Radiometria/métodos , Terrorismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA