Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
1.
BMC Psychiatry ; 24(1): 197, 2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38461285

RESUMO

With the increasing global aging population, dementia care has rapidly become a major social problem. Current diagnosis of Behavior and Psychological Symptoms of Dementia (BPSD) relies on clinical interviews, and behavioral rating scales based on a period of behavior observation, but these methods are not suitable for identification of occurrence of BPSD in the daily living, which is necessary for providing appropriate interventions for dementia, though, has been studied by few research groups in the literature. To address these issues, in this study developed a BPSD monitoring system consisting of a Psycho-Cognitive (PsyCo) BPSD model, a Behavior-Physio-Environment (BePhyEn) BPSD model, and an implementation platform. The PsyCo BPSD model provides BPSD assessment support to caregivers and care providers, while the BePhyEn BPSD model provides instantaneous alerts for BPSD enabled by a 24-hour home monitoring platform for early intervention, and thereby alleviation of burden to patients and caregivers. Data for acquiring the models were generated through extensive literature review and regularity determined. A mobile robot was utilized as the implementation platform for improving sensitivity of sensors for home monitoring, and elderly individual following algorithms were investigated. Experiments in a virtual home environment showed that, a virtual BPSD elderly individual can be followed safely by the robot, and BPSD occurrence could be identified accurately, demonstrating the possibility of modeling and identification of BPSD in home environment.


Assuntos
Demência , Humanos , Idoso , Demência/psicologia , Cuidadores/psicologia , Sintomas Comportamentais/psicologia
2.
BMC Oral Health ; 24(1): 388, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38532349

RESUMO

BACKGROUND: The repair of bone defects caused by periodontal diseases is a difficult challenge in clinical treatment. Dental pulp stem cells (DPSCs) are widely studied for alveolar bone repair. The current investigation aimed to examine the specific mechanisms underlying the role of Zinc finger DHHC-type palmitoyl transferases 16 (ZDHHC16) in the process of osteogenic differentiation (OD) of DPSCs. METHODS: The lentiviral vectors ZDHHC16 or si-ZDHHC16 were introduced in the DPSCs and then the cells were induced by an odontogenic medium for 21 days. Subsequently, Quantitate Polymerase Chain Reaction (PCR), immunofluorescent staining, proliferation assay, ethynyl deoxyuridine (EdU) staining, and western blot analysis were used to investigate the specific details of ZDHHC16 contribution in OD of DPSCs. RESULTS: Our findings indicate that ZDHHC16 exhibited a suppressive effect on cellular proliferation and oxidative phosphorylation, while concurrently inducing ferroptosis in DPSCs. Moreover, the inhibition of ZDHHC16 promoted cell development and OD and reduced ferroptosis of DPSCs. The expression of p-CREB was suppressed by ZDHHC16, and immunoprecipitation (IP) analysis revealed that ZDHHC16 protein exhibited interconnection with cAMP-response element binding protein (CREB) of DPSCs. The CREB suppression reduced the impacts of ZDHHC16 on OD and ferroptosis of DPSCs. The activation of CREB also reduced the influences of si-ZDHHC16 on OD and ferroptosis of DPSCs. CONCLUSIONS: These findings provide evidences to support a negative association between ZDHHC16 and OD of DPSCs, which might be mediated by ferroptosis of DPSCs via CREB.


Assuntos
Ferroptose , Osteogênese , Humanos , Proteína de Ligação ao Elemento de Resposta ao AMP Cíclico/metabolismo , Proteína de Ligação ao Elemento de Resposta ao AMP Cíclico/farmacologia , Polpa Dentária , Células-Tronco/metabolismo , Diferenciação Celular , Células Cultivadas , Proliferação de Células , Aciltransferases/metabolismo , Aciltransferases/farmacologia
3.
Sensors (Basel) ; 23(2)2023 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-36679629

RESUMO

To provide a stable surgical view in Minimally Invasive Surgery (MIS), it is necessary for a flexible endoscope applied in MIS to have adjustable stiffness to resist different external loads from surrounding organs and tissues. Pneumatic soft actuators are expected to fulfill this role, since they could feed the endoscope with an internal access channel and adjust their stiffness via an antagonistic mechanism. For that purpose, it is essential to estimate the external load. In this study, we proposed a neural network (NN)-based active load-sensing scheme and stiffness adjustment for a soft actuator for MIS support with antagonistic chambers for three degrees of freedom (DoFs) of control. To deal with the influence of the nonlinearity of the soft actuating system and uncertainty of the interaction between the soft actuator and its environment, an environment exploration strategy was studied for improving the robustness of sensing. Moreover, a NN-based inverse dynamics model for controlling the stiffness of the soft actuator with different flexible endoscopes was proposed too. The results showed that the exploration strategy with different sequence lengths improved the estimation accuracy of external loads in different conditions. The proposed method for external load exploration and inverse dynamics model could be used for in-depth studies of stiffness control of soft actuators for MIS support.


Assuntos
Robótica , Robótica/métodos , Desenho de Equipamento , Procedimentos Cirúrgicos Minimamente Invasivos , Endoscópios , Redes Neurais de Computação
4.
BMC Cancer ; 21(1): 1136, 2021 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-34688269

RESUMO

BACKGROUND: C5aR has been extensively studied in recent years as an essential component of the complement system. However, the role of C5aR in tumors has not been sufficiently investigated and summarized. The aim of this meta-analysis was to investigate the prognostic value of C5aR in solid tumors as well as the correlation between C5aR and clinicopathological features. METHODS: Relevant study collection was performed in PubMed, Embase, Web of Science, BIOSIS Previews, Cochrane Library until July 10, 2021. Pooled hazard ratios (HRs), odds ratios (ORs), and 95% confidence intervals (CIs) were calculated. Sensitivity analyses were performed to assess the robustness of this study, while publication bias was tested by Begg's and Egger's tests. RESULTS: A total of 11 studies involving 1577 patients were included in the study. Our results suggest that the high-level C5aR expression in tumor tissue predicted unsatisfactory overall survival (OS) (HR = 1.92, 95% CI:1.47-2.50, P < 0.001) and recurrence-free survival (RFS) (HR = 2.19, 95% CI:1.47-3.27, P < 0.001). Besides, a higher level of C5aR expression was associated with larger tumor size (OR = 1.58, 95% CI: 1.18-2.10, P = 0.002) and the occurrence of metastases in lymph nodes (OR = 1.99, 95% CI: 1.46-2.72, P<0.001), whereas it was independent of tumor stage, vascular invasion and tumor differentiation. CONCLUSION: In conclusion, C5aR may be a potential biomarker for evaluating tumor prognosis and treatment.


Assuntos
Biomarcadores Tumorais/metabolismo , Receptor da Anafilatoxina C5a/metabolismo , Humanos , Prognóstico
5.
Anticancer Drugs ; 31(3): 223-230, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31789624

RESUMO

Hepatocellular carcinoma (HCC) is a complicated and poor prognosis cancer, necessitating the development of a potential treatment strategy. In this study, we initially revealed that LukS-PV belonged to leukocidin family performs an anti-HCC action. Then, we used liquid chromatography-mass spectrometry (LC/MS) to compare protein expression profiles of the LukS-PV-treated human HCC cell lines HepG2 and the control cells. GO annotations and Kyoto Encyclopedia of Genes and Genomes pathway analysis were carried out of differential expression followed by protein-protein interactome, to explore the underlying cancer suppressor mechanisms of LukS-PV for human HCC. A total of 88 upregulated proteins and 46 downregulated proteins were identified. The top 10 proteins identified by the MCC method are FN1, APP, TIMP1, nucleobindin-1, GOLM1, APLP2, CYR61, CD63, ENG, and CD9. Our observation on protein expression indicated that LukS-PV produces a signature affecting central carbon metabolism in cancer, galactose metabolism, and fructose and mannose metabolism pathways. The results give a functional effects and molecular mechanism insight, following LukS-PV treatment.


Assuntos
Antineoplásicos/farmacologia , Proteínas de Bactérias/farmacologia , Toxinas Bacterianas/farmacologia , Carcinoma Hepatocelular/tratamento farmacológico , Exotoxinas/farmacologia , Leucocidinas/farmacologia , Neoplasias Hepáticas/tratamento farmacológico , Proteômica/métodos , Apoptose/efeitos dos fármacos , Carcinoma Hepatocelular/metabolismo , Células Hep G2 , Humanos , Neoplasias Hepáticas/metabolismo , Redes e Vias Metabólicas/efeitos dos fármacos , Invasividade Neoplásica , Mapas de Interação de Proteínas , Reação em Cadeia da Polimerase em Tempo Real
6.
Sensors (Basel) ; 20(5)2020 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-32182766

RESUMO

Variability in individual pain sensitivity is a major problem in pain assessment. There have been studies reported using pain-event related potential (pain-ERP) for evaluating pain perception. However, none of them has achieved high accuracy in estimating multiple pain perception levels. A major reason lies in the lack of investigation of feature extraction. The goal of this study is to assess four different pain perception levels through classification of pain-ERP, elicited by transcutaneous electrical stimulation on healthy subjects. Nonlinear methods: Higuchi's fractal dimension, Grassberger-Procaccia correlation dimension, with auto-correlation, and moving variance functions were introduced into the feature extraction. Fisher score was used to select the most discriminative channels and features. As a result, the correlation dimension with a moving variance without channel selection achieved the best accuracies of 100% for both the two-level and the three-level classification but degraded to 75% for the four-level classification. The best combined feature group is the variance-based one, which achieved accuracy of 87.5% and 100% for the four-level and three-level classification, respectively. Moreover, the features extracted from less than 20 trials could not achieve sensible accuracy, which makes it difficult for an instantaneous pain perception levels evaluation. These results show strong evidence on the possibility of objective pain assessment using nonlinear feature-based classification of pain-ERP.


Assuntos
Estimulação Elétrica/métodos , Potenciais Evocados/fisiologia , Percepção da Dor/fisiologia , Dor , Adulto , Eletroencefalografia , Feminino , Fractais , Humanos , Masculino , Pessoa de Meia-Idade , Dinâmica não Linear , Dor/classificação , Dor/fisiopatologia , Processamento de Sinais Assistido por Computador , Adulto Jovem
7.
ScientificWorldJournal ; 2014: 280207, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25587560

RESUMO

Our research is focused on the development of an at-home health care biomonitoring mobile robot for the people in demand. Main task of the robot is to detect and track a designated subject while recognizing his/her activity for analysis and to provide warning in an emergency. In order to push forward the system towards its real application, in this study, we tested the robustness of the robot system with several major environment changes, control parameter changes, and subject variation. First, an improved color tracker was analyzed to find out the limitations and constraints of the robot visual tracking considering the suitable illumination values and tracking distance intervals. Then, regarding subject safety and continuous robot based subject tracking, various control parameters were tested on different layouts in a room. Finally, the main objective of the system is to find out walking activities for different patterns for further analysis. Therefore, we proposed a fast, simple, and person specific new activity recognition model by making full use of localization information, which is robust to partial occlusion. The proposed activity recognition algorithm was tested on different walking patterns with different subjects, and the results showed high recognition accuracy.


Assuntos
Monitoramento Ambiental , Reconhecimento Automatizado de Padrão , Robótica/instrumentação , Humanos , Aumento da Imagem , Modelos Teóricos , Robótica/métodos
8.
Infrared Phys Technol ; 66: 160-175, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32288546

RESUMO

The invention of thermography, in the 1950s, posed a formidable problem to the research community: What is the relationship between disease and heat radiation captured with Infrared (IR) cameras? The research community responded with a continuous effort to find this crucial relationship. This effort was aided by advances in processing techniques, improved sensitivity and spatial resolution of thermal sensors. However, despite this progress fundamental issues with this imaging modality still remain. The main problem is that the link between disease and heat radiation is complex and in many cases even non-linear. Furthermore, the change in heat radiation as well as the change in radiation pattern, which indicate disease, is minute. On a technical level, this poses high requirements on image capturing and processing. On a more abstract level, these problems lead to inter-observer variability and on an even more abstract level they lead to a lack of trust in this imaging modality. In this review, we adopt the position that these problems can only be solved through a strict application of scientific principles and objective performance assessment. Computing machinery is inherently objective; this helps us to apply scientific principles in a transparent way and to assess the performance results. As a consequence, we aim to promote thermography based Computer-Aided Diagnosis (CAD) systems. Another benefit of CAD systems comes from the fact that the diagnostic accuracy is linked to the capability of the computing machinery and, in general, computers become ever more potent. We predict that a pervasive application of computers and networking technology in medicine will help us to overcome the shortcomings of any single imaging modality and this will pave the way for integrated health care systems which maximize the quality of patient care.

9.
Front Hum Neurosci ; 18: 1308549, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38708141

RESUMO

The ability to stimulate deep brain regions in a focal manner brings new opportunities for treating brain disorders. Temporal interference (TI) stimulation has been suggested as a method to achieve focused stimulation in deep brain targets. Individual-level knowledge of the interferential currents has permitted personalizing TI montage via subject-specific digital human head models, facilitating the estimation of interferential electric currents in the brain. While this individual approach offers a high degree of personalization, the significant intra-and inter-individual variability among specific head models poses challenges when comparing electric-field doses. Furthermore, MRI acquisition to develop a personalized head model, followed by precise methods for placing the optimized electrode positions, is complex and not always available in various clinical settings. Instead, the registration of individual electric fields into brain templates has offered insights into population-level effects and enabled montage optimization using common scalp landmarks. However, population-level knowledge of the interferential currents remains scarce. This work aimed to investigate the effectiveness of targeting deep brain areas using TI in different populations. The results showed a trade-off between deep stimulation and unwanted cortical neuromodulation, which is target-dependent at the group level. A consistent modulated electric field appeared in the deep brain target when the same montage was applied in different populations. However, the performance in terms of focality and variability varied when the same montage was used among populations. Also, group-level TI exhibited greater focality than tACS, reducing unwanted neuromodulation volume in the cortical part by at least 1.5 times, albeit with higher variability. These results provide valuable population-level insights when considering TI montage selection.

10.
Digit Health ; 10: 20552076241277746, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39247094

RESUMO

Objective: A ballistocardiogram (BCG) is a vibration signal generated by the ejection of the blood in each cardiac cycle. The BCG has significant variability in amplitude, temporal aspects, and the deficiency of waveform components, attributed to individual differences, instantaneous heart rate, and the posture of the person being measured. This variability may make methods of extracting J-waves, the most distinct components of BCG less generalizable so that the J-waves could not be precisely localized, and further analysis is difficult. This study is dedicated to solving the variability of BCG to achieve accurate feature extraction. Methods: Inspired by the generation mechanism of the BCG, we proposed an original method based on a profile of second-order derivative of BCG waveform (2ndD-P) to capture the nature of vibration and solve the variability, thereby accurately localizing the components especially when the J-wave is not prominent. Results: In this study, 51 recordings of resting state and 11 recordings of high-heart-rate from 24 participants were used to validate the algorithm. Each recording lasts about 3 min. For resting state data, the sensitivity and positive predictivity of proposed method are: 98.29% and 98.64%, respectively. For high-heart-rate data, the proposed method achieved a performance comparable to those of low-heart-rate: 97.14% and 99.01% for sensitivity and positive predictivity, respectively. Conclusion: Our proposed method can detect the peaks of the J-wave more accurately than conventional extraction methods, under the presence of different types of variability. Higher performance was achieved for BCG with non-prominent J-waves, in both low- and high-heart-rate cases.

11.
Front Bioeng Biotechnol ; 12: 1334643, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38948382

RESUMO

The simulation-to-reality (sim2real) problem is a common issue when deploying simulation-trained models to real-world scenarios, especially given the extremely high imbalance between simulation and real-world data (scarce real-world data). Although the cycle-consistent generative adversarial network (CycleGAN) has demonstrated promise in addressing some sim2real issues, it encounters limitations in situations of data imbalance due to the lower capacity of the discriminator and the indeterminacy of learned sim2real mapping. To overcome such problems, we proposed the imbalanced Sim2Real scheme (ImbalSim2Real). Differing from CycleGAN, the ImbalSim2Real scheme segments the dataset into paired and unpaired data for two-fold training. The unpaired data incorporated discriminator-enhanced samples to further squash the solution space of the discriminator, for enhancing the discriminator's ability. For paired data, a term targeted regression loss was integrated to ensure specific and quantitative mapping and further minimize the solution space of the generator. The ImbalSim2Real scheme was validated through numerical experiments, demonstrating its superiority over conventional sim2real methods. In addition, as an application of the proposed ImbalSim2Real scheme, we designed a finger joint stiffness self-sensing framework, where the validation loss for estimating real-world finger joint stiffness was reduced by roughly 41% compared to the supervised learning method that was trained with scarce real-world data and by 56% relative to the CycleGAN trained with the imbalanced dataset. Our proposed scheme and framework have potential applicability to bio-signal estimation when facing an imbalanced sim2real problem.

12.
BMC Mol Cell Biol ; 25(1): 19, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39090552

RESUMO

BACKGROUND: Hepatitis B virus (HBV) infection poses a substantial threat to human health, impacting not only infected individuals but also potentially exerting adverse effects on the health of their offspring. The underlying mechanisms driving this phenomenon remain elusive. This study aims to shed light on this issue by examining alterations in paternally imprinted genes within sperm. METHODS: A cohort of 35 individuals with normal semen analysis, comprising 17 hepatitis B surface antigen (HBsAg)-positive and 18 negative individuals, was recruited. Based on the previous research and the Online Mendelian Inheritance in Man database (OMIM, https://www.omim.org/ ), targeted promoter methylation sequencing was employed to investigate 28 paternally imprinted genes associated with various diseases. RESULTS: Bioinformatic analyses revealed 42 differentially methylated sites across 29 CpG islands within 19 genes and four differentially methylated CpG islands within four genes. At the gene level, an increase in methylation of DNMT1 and a decrease in methylation of CUL7, PRKAG2, and TP53 were observed. DNA methylation haplotype analysis identified 51 differentially methylated haplotypes within 36 CpG islands across 22 genes. CONCLUSIONS: This is the first study to explore the effects of HBV infection on sperm DNA methylation and the potential underlying mechanisms of intergenerational influence of paternal HBV infection.


Assuntos
Ilhas de CpG , Metilação de DNA , Impressão Genômica , Vírus da Hepatite B , Hepatite B , Regiões Promotoras Genéticas , Espermatozoides , Humanos , Masculino , Metilação de DNA/genética , Regiões Promotoras Genéticas/genética , Espermatozoides/metabolismo , Ilhas de CpG/genética , Impressão Genômica/genética , Hepatite B/genética , Hepatite B/virologia , Adulto , Vírus da Hepatite B/genética , Haplótipos/genética , Pessoa de Meia-Idade
13.
J Phys Ther Sci ; 25(5): 605-10, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-24259812

RESUMO

[Purpose] In this study, combined training with breathing resistance and sustained physical exertion was carried out to evaluate its physiological effects and its effect on improve endurance capacity. [Subjects and Methods] The subjects were nine healthy adults (mean age 20.4, SD ± 1.7 years). The combined training group (n = 5) carried out 6 weeks of combined training using a cycle ergometer, with exercise load tests and respiratory function tests performed before and after the training. The results of the training were compared to a control group (n = 4) that only performed the cycling exercise without the combined training with breathing resistance. [Results] In the combined training group, ventilatory threshold, maximal load of the cycle ergometer in exercise load tests, and maximal voluntary ventilation increased after training. These increases after training were all significant, but none of these variables changed significantly in the control group. [Conclusion] The results imply that in comparison to conventional training methods, combined training with breathing resistance and sustained physical exertion is beneficial for increasing endurance capacity and respiratory muscle function. This result provides important information regarding the effects of the new training method for improving endurance capacity.

14.
Biomed Phys Eng Express ; 9(5)2023 08 29.
Artigo em Inglês | MEDLINE | ID: mdl-37595567

RESUMO

Simulation in healthcare can help train, improve, and evaluate medical personnel's skills. In the case of needle insertion/manipulation inside the muscle during an nEMG examination, a training simulator Requires estimating the position of the needle to output the electrical muscle activity in real time according to the training plan. External cameras can be used to estimate the needle location; however, different error sources can make its implementation difficult and new medical sensing technologies are needed. This study introduces and demonstrates the feasibility of a conductive phantom that serves as the medium for needle insertion and senses the 3D needle position based on a technique named electro-localization for the first time. The proposed conductive phantom is designed so that different voltage distributions are generated in the phantom using electrodes placed on its borders. The needle is inserted in the phantom, and the recorded voltages are mapped to spatial coordinates using a finite element method (FEM)-based computational model of the conductive phantom to estimate the 3D needle tip position. Experimental and simulation results of phantom voltage distributions agreed. In 2D mapping (no depth consideration), the needle position error was 1.7 mm, which was marginally reduced if only the central area of the phantom was used (1.5 mm). In 3D mapping, the error was 4 mm. This study showed the feasibility of using a conductive muscle phantom as a new embedded sensor that estimates needle position for medical training of nEMG without relying on external sensors.


Assuntos
Músculos , Imagens de Fantasmas , Simulação por Computador , Condutividade Elétrica , Eletrodos
15.
J Magn Reson ; 352: 107463, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37207466

RESUMO

In this paper, a simulator named "MagTetris" is proposed for fast magnetic field (B-field) and force calculation for permanent magnet arrays (PMAs) designs consisting of cuboid and arc-shaped magnets (approximated by cuboids) with arbitrary configurations. The proposed simulator can compute the B-field of a PMA on arbitrary observation planes and the magnetic force acting on any magnet/group of magnets. An accelerated calculation method for B-fields of PMAs is developed based on the current model of permanent magnet, which is further extended to magnetic force calculation. The proposed method and the associated codes were validated with numerical simulation and experimental results. The calculation speed of "MagTetris" is at least 500 times higher than that using finite-element method (FEM)-based software with uncompromised accuracy. Compared with a freeware in Python, Magpylib, "MagTetris" has a calculation acceleration of greater than 50% using the same language. "MagTetris" has a simple data structure, which can be easily migrated to other programming languages maintaining similar performances. This proposed simulator can accelerate a PMA design and/or allow designs with high flexibility considering the B-field and force simultaneously. It can facilitate and accelerate innovations of magnet designs to advance dedicated portable MRI in terms of compactness, weight, and performance.


Assuntos
Imageamento por Ressonância Magnética , Imãs , Desenho de Equipamento , Imageamento por Ressonância Magnética/métodos , Campos Magnéticos , Magnetismo
16.
Front Bioeng Biotechnol ; 11: 1319922, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38164406

RESUMO

Introduction: Minimally Invasive Surgery (MIS) offers targeted surgical access with reduced invasiveness; however, the maneuverability challenges of traditional instruments in this domain underscore the need for innovative solutions. Soft actuators activated by fluids or gases present a promising strategy for augmenting endoscopic capabilities, thereby enhancing the surgical precision in MIS. This study aimed to explore the intricate dynamics of the interactions between soft actuators and endoscopes, with an emphasis on the pivotal role of cross-sectional chamber shapes. While previous studies have touched on the influence of chamber shapes on bending properties, we provide a comprehensive exploration. We explore how these shapes modulate friction forces, which in turn influence the interactions governing bending, response, and stiffness adjustability, all of which are essential for enhancing endoscope maneuverability in MIS contexts. Methods: A novel bilateral symmetrical air chamber design was adopted to investigate various chamber shapes. We employed finite element analysis (FEA) simulations followed by prototype testing to evaluate the interactions driven by these chamber shapes and to discern their impact on actuator properties. Recognizing the pivotal role of friction in these interactions, we conducted dedicated friction experiments. These experiments further deepened our understanding of the relationship between chamber shape and friction, and how this synergy influences the properties of the actuator. Results: Our findings showed that actuators with wider chambers generate larger friction forces, thereby enhancing the interaction and improving the bending, response, and stiffness adjustability. Additionally, the soft actuator significantly improved the maneuverability and bending radius of the endoscope, demonstrating enhanced navigation capabilities in complex environments. Discussion: The shape of a cross-sectional chamber plays a pivotal role in designing soft actuators for MIS applications. Our research emphasizes the importance of this design component, offering key insights for the development of endoscope-supporting soft actuators that can effectively handle intricate actuator-endoscope interactions, thereby enhancing surgical outcomes.

17.
Front Neurorobot ; 17: 1269432, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37614969

RESUMO

[This corrects the article DOI: 10.3389/fnbot.2023.1047493.].

18.
Artigo em Inglês | MEDLINE | ID: mdl-38082583

RESUMO

Electrical properties (EPs) are expected as biomarkers for early cancer detection. Magnetic resonance electrical properties tomography (MREPT) is a technique to non-invasively estimate the EPs of tissues from MRI measurements. While noise sensitivity and artifact problems of MREPT are being solved progressively through recent efforts, the loss of tissue contrast emerges as an obstacle to the clinical applications of MREPT. To solve the problem, we propose a reconstruction error compensation neural network scheme (REC-NN) for a typical analytic MREPT method, Stab-EPT. Two NN structures: one with only ResNet blocks, and the other hybridizing ResNet blocks with an encoder-decoder structure. Results of experiments with digital brain phantoms show that, compared with Stab-EPT, and conventional NN based reconstruction, REC-NN improves both reconstruction accuracy and tissue contrast. It is found that, the encoder-decoder structure could improve the compensation accuracy of EPs in homogeneous region but showed worse reconstruction than only ResNet structure for tumorous tissues unseen in the training samples. Future research is required to address overcompensation problems, optimization of NN structure and application to clinical data.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética , Impedância Elétrica , Imageamento por Ressonância Magnética/métodos , Tomografia/métodos , Espectroscopia de Ressonância Magnética , Redes Neurais de Computação
19.
Front Neurorobot ; 17: 1047493, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36845070

RESUMO

The combination of smart soft composite structure based shape memory alloy (SMA) and exoskeleton technology has the advantages of light weight, energy saving, and great human-exoskeleton interaction. However, there are no relevant studies on the application of SMA-based soft composite structure (SSCS) in hand exoskeletons. The main difficulty is that directional mechanical properties of SSCS need to comply with fingers movement, and SSCS can deliver enough output torque and displacement to the relevant joints. This paper aims to study the application of SSCS for wearable rehabilitation gloves and explore its bionic driving mechanism. This paper proposes a soft wearable glove (Glove-SSCS) for hand rehabilitation actuated by the SSCS, based on finger force analysis under different drive modes. The Glove-SSCS can support five-finger flexion and extension, weighs only 120 g, and adopts modular design. Each drive module adopts a soft composite structure. And the structure integrates actuation, sensing and execution, including an active layer (SMA spring), a passive layer (manganese steel sheet), a sensing layer (bending sensor) and connection layers. To obtain a high-performance SMA actuators, the performance of SMA materials was tested in terms of temperature and voltage, temperature at the shortest length, pre-tensile length and load. And the human-exoskeleton coupling model of Glove-SSCS is established and analyzed from force and motion. The results show that the Glove-SSCS can realize bidirectional movements of fingers flexion and extension, with ranges of motion are 90-110° and 30-40°, and their cycles are 13-19 s and 11-13 s. During the use of Glove-SSCS, the temperature of gloves is from 25 to 67°C, and the surface temperature of hands is from 32 to 36°C. The temperature of Glove-SSCS can be kept at the lowest temperature of SMA operation without much impact on the human body.

20.
J Neuroeng Rehabil ; 9: 33, 2012 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-22682425

RESUMO

BACKGROUND: Prosthetic hand users have to rely extensively on visual feedback, which seems to lead to a high conscious burden for the users, in order to manipulate their prosthetic devices. Indirect methods (electro-cutaneous, vibrotactile, auditory cues) have been used to convey information from the artificial limb to the amputee, but the usability and advantages of these feedback methods were explored mainly by looking at the performance results, not taking into account measurements of the user's mental effort, attention, and emotions. The main objective of this study was to explore the feasibility of using psycho-physiological measurements to assess cognitive effort when manipulating a robot hand with and without the usage of a sensory substitution system based on auditory feedback, and how these psycho-physiological recordings relate to temporal and grasping performance in a static setting. METHODS: 10 male subjects (26+/-years old), participated in this study and were asked to come for 2 consecutive days. On the first day the experiment objective, tasks, and experiment setting was explained. Then, they completed a 30 minutes guided training. On the second day each subject was tested in 3 different modalities: Auditory Feedback only control (AF), Visual Feedback only control (VF), and Audiovisual Feedback control (AVF). For each modality they were asked to perform 10 trials. At the end of each test, the subject had to answer the NASA TLX questionnaire. Also, during the test the subject's EEG, ECG, electro-dermal activity (EDA), and respiration rate were measured. RESULTS: The results show that a higher mental effort is needed when the subjects rely only on their vision, and that this effort seems to be reduced when auditory feedback is added to the human-machine interaction (multimodal feedback). Furthermore, better temporal performance and better grasping performance was obtained in the audiovisual modality. CONCLUSIONS: The performance improvements when using auditory cues, along with vision (multimodal feedback), can be attributed to a reduced attentional demand during the task, which can be attributed to a visual "pop-out" or enhance effect. Also, the NASA TLX, the EEG's Alpha and Beta band, and the Heart Rate could be used to further evaluate sensory feedback systems in prosthetic applications.


Assuntos
Estimulação Acústica/métodos , Membros Artificiais , Retroalimentação Sensorial/fisiologia , Mãos/fisiologia , Psicofisiologia/métodos , Adulto , Cognição/fisiologia , Eletrocardiografia , Eletroencefalografia , Estudos de Viabilidade , Resposta Galvânica da Pele/fisiologia , Força da Mão/fisiologia , Frequência Cardíaca/fisiologia , Humanos , Masculino , Processos Mentais/fisiologia , Desenho de Prótese , Desempenho Psicomotor/fisiologia , Taxa Respiratória/fisiologia , Robótica , Autoavaliação (Psicologia) , Inquéritos e Questionários , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA