Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
BMC Health Serv Res ; 20(1): 468, 2020 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-32456639

RESUMO

BACKGROUND: Accurate diagnosis of anemia by community workers using a point-of-care device is a challenge. The objective of the study was to establish the diagnostic accuracy of point-of-care devices for detecting anemia in community settings. METHODS: It was diagnostic accuracy study with cross-sectional design on adult patients attending the outpatient department of rural/ urban health centres of Medical colleges from India. The index tests were HemoCue, TrueHb, Massimo's device and spectroscopic device, compared against autoanalyzer (gold standard). Accuracy was expressed by sensitivity, specificity, likelihood ratios, predictive values, area under the curve (AUC) and levels of agreement. For the diagnostic accuracy component, 1407 participants were recruited with a minimum of 600 for each device. An additional 200 participants were considered to elucidate the performance of devices in different weather conditions. RESULTS: HemoCue and TrueHb performed better than Massimo and spectroscopic devices. Detection of anemia by technicians was similar between TrueHb and HemoCue (AUC 0.92 v/s 0.90, p > 0.05). Community workers performed better with Hemocue for detecting anemia compared to TrueHb (AUC 0.92 v/s 0.90, p < 0.05). For detection of severe anemia, accuracy of TrueHb was significantly better with technicians (AUC 0.91 v/s 0.70; p < 0.05) and community workers (AUC 0.91 v/s 0.73; p < 0.05). HemoCue showed a bias or mean difference (95%CI) of 0.47 g/dl (0.42, 0.52) for all values, and 0.92 g/dl (0.82, 1.03) for severe anemia. For TrueHb, it was - 0.28 g/dl (- 0.37, - 0.20) for all readings, and 0.06 g/dl (- 0.52, 0.63) for severe anemia. TrueHb appeared to be more consistent across different weather conditions, although it overestimated Hb in extreme cold weather conditions. CONCLUSION: For detection of anemia, True Hb and HemoCue were comparable. For severe anemia, True Hb seemed to be a better and feasible point-of-care device for detecting anemia in the community settings.


Assuntos
Anemia/diagnóstico , Serviços de Saúde Comunitária , Sistemas Automatizados de Assistência Junto ao Leito , Adulto , Estudos Transversais , Feminino , Humanos , Índia , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
2.
J Clin Endocrinol Metab ; 98(10): 4195-202, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23966237

RESUMO

CONTEXT: Questionnaire studies linked symptoms of obstructive sleep apnea (OSA) to the risk of gestational diabetes mellitus (GDM). Whether this association is present when OSA is assessed objectively by polysomnography is not known. OBJECTIVE: The objective of the study was to assess the relationship between pregnancy, OSA, and GDM. DESIGN, SETTING, AND PARTICIPANTS: We conducted observational case-control studies using polysomnography in 15 nonpregnant, nondiabetic women (NP-NGT), 15 pregnant women with normal glucose tolerance (P-NGT), and 15 pregnant women with GDM (P-GDM). The groups were frequency matched for age and race/ethnicity. Pregnant women were studied during the late second to early third trimester. MAIN OUTCOME MEASURES: Comparisons of OSA diagnosis and sleep parameters between NP-NGT and P-NGT to assess the impact of pregnancy and between P-NGT and P-GDM to explore the association between GDM and OSA were measured. RESULTS: Compared with NP-NGT, P-NGT women had a higher apnea hypopnea index (AHI) (median 2.0 vs 0.5, P = .03) and more disrupted sleep as reflected by a higher wake time after sleep onset (median 66 vs 21 min, P < .01) and a higher microarousal index (median 16.4 vs 10.6, P = .01). Among the pregnant women, P-GDM had markedly lower total sleep time (median 397 vs 464 min, P = .02) and a higher AHI (median 8.2 vs 2.0, P = .05) than P-NGT women. OSA was more prevalent in P-GDM than in P-NGT women (73% vs 27%, P = .01). After adjustment for prepregnancy body mass index, the diagnosis of GDM was associated with a diagnosis of OSA [odds ratio 6.60 (95% confidence interval 1.15-37.96)]. In pregnancy, after adjusting for prepregnancy body mass index, higher microarousal index significantly associated with higher hemoglobin A1c and fasting glucose levels. Higher oxygen desaturation index was associated with higher fasting glucose levels. CONCLUSION: Pregnancy is associated with sleep disturbances. Sleep is more disturbed in GDM than in P-NGT women. There is a strong association between GDM and OSA.


Assuntos
Diabetes Gestacional/fisiopatologia , Complicações na Gravidez/fisiopatologia , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/fisiopatologia , Adulto , Glicemia , Índice de Massa Corporal , Estudos de Casos e Controles , Feminino , Humanos , Resistência à Insulina , Obesidade/complicações , Obesidade/fisiopatologia , Gravidez , Terceiro Trimestre da Gravidez
3.
Diabetes Care ; 34(11): 2454-7, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21926292

RESUMO

OBJECTIVE: To explore relationships among sleep disturbances, glucose tolerance, and pregnancy outcomes. RESEARCH DESIGN AND METHODS: Four validated sleep questionnaires were administered to 169 pregnant women at the time of 50-g oral glucose tolerance testing (OGTT) during the second trimester. Pregnancy outcomes were analyzed in 108 women with normal glucose tolerance (NGT). RESULTS: Of the participants, 41% had excessive daytime sleepiness (Epworth Sleepiness Scale [ESS] >8); 64% had poor sleep quality; 25% snored frequently; 29% had increased risk of sleep-disordered breathing (SDB); 52% experienced short sleep (SS); 19% had both increased SDB risk and SS (SDB/SS); and 14% had daytime dysfunction. Reported sleep duration inversely correlated with glucose values from 50-g OGTT (r = -0.21, P < 0.01). Each hour of reduced sleep time was associated with a 4% increase in glucose levels. Increased likelihood of gestational diabetes mellitus (GDM) was found in subjects with increased SDB risk (odds ratio 3.0 [95% CI 1.2-7.4]), SS (2.4 [1.0-5.9]), SDB/SS (3.4 [1.3-8.7]), and frequent snoring (3.4 [1.3-8.8], after adjustment for BMI). Among NGT subjects, preterm delivery was more frequent in those with increased ESS (P = 0.02), poor sleep quality (P = 0.02), and SS (P = 0.03). Neonatal intensive care unit admissions were associated with increased ESS (P = 0.03), SDB/SS (P = 0.03), and daytime dysfunction (P < 0.01) in mothers. CONCLUSIONS: Pregnant women experience significant sleep disturbances that are associated with increased risk of GDM and unfavorable pregnancy outcomes. Pregnant women with increased SDB risk, frequent snoring, and sleep duration of <7 h/night have increased risk of developing GDM.


Assuntos
Glicemia/metabolismo , Diabetes Gestacional/fisiopatologia , Intolerância à Glucose , Resultado da Gravidez , Transtornos do Sono-Vigília/complicações , Adulto , Estudos de Casos e Controles , Diabetes Gestacional/epidemiologia , Feminino , Teste de Tolerância a Glucose , Humanos , Modelos Logísticos , Gravidez , Segundo Trimestre da Gravidez , Fatores de Risco , Inquéritos e Questionários , Fatores de Tempo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA