Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-39135541

RESUMO

PURPOSE: Kinematically aligned total knee arthroplasty (KA TKA), as a pure resurfacing procedure, is based on matching implant thickness with bone cut and kerf thickness, plus cartilage wear. However, the assumption of a consistent 2 mm femoral cartilage thickness remains unproven. This study aimed to systematically review the available literature concerning magnetic resonance imaging (MRI) assessment of femoral cartilage thickness in non-arthritic patients. Our hypothesis was that cartilage thickness values would vary significantly among individuals, thereby challenging the established KA paradigm of 'one-cartilage-fits-all'. METHODS: Systematic literature searches (Pubmed, Scopus and Cochrane Library) followed PRISMA guidelines. English-language studies assessing distal and posterior femoral cartilage thickness using MRI in non-arthritic adults were included. Studies lacking numerical cartilage thickness data, involving post-operative MRI, considering total femoro-tibial cartilage thickness, or failing to specify the compartment of the knee being studied were excluded. RESULTS: Overall, 27 studies comprising 8170 MRIs were analysed. Weighted mean femoral cartilage thicknesses were: 2.05 ± 0.62 mm (mean range 1.06-2.6) for the distal medial condyle, 1.95 ± 0.4 mm (mean range 1.15-2.5) for the distal lateral condyle, 2.44 ± 0.5 mm (mean range 1.37-2.6) for the posterior medial condyle and 2.27 ± 0.38 mm (mean range 1.48-2.5) for the posterior lateral condyle. DISCUSSION: Femoral cartilage thickness varies significantly across patients. In KA TKA, relying on a fixed thickness of 2 mm may jeopardize the accurate restoration of individual anatomy, leading to errors in implant coronal and rotational alignment. An intraoperative assessment of cartilage thickness may be advisable to express the KA philosophy at its full potential. LEVEL OF EVIDENCE: Level IV.

2.
Int Orthop ; 48(8): 1979-1985, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38622366

RESUMO

PURPOSE: In the last decades, there has been a refinement in total hip arthroplasty, which allowed surgeons to achieve the highest performance and better patient outcomes. Preoperative planning in primary hip arthroplasty is an essential step that guides the surgeon in restoring the anatomy and biomechanics of the joint. This study aims to evaluate the accuracy of the 2D digital planning, considering cup sizing, stem sizing, and limb length discrepancy. Additionally, we conducted a multivariable analysis of demographic data and comorbidities to find factors influencing preoperative planning. METHODS: This retrospective study analyzed the planning accuracy in 800 consecutive uncemented primary total hip arthroplasty. We compared the preoperatively planned total hip arthroplasty with postoperative results regarding the planned component size, the implanted size, and the lower limb length restoration. Therefore, we investigated factors influencing planning accuracy: overweight and obesity, sex, age, past medical history, comorbidities, and implant design. All the surgeries were performed in the posterolateral approach by one expert surgeon who did the preoperative planning. The preoperative planning was determined to be (a) exact if the planned and the implanted components were the same size and (b) accurate if exact ± one size. The restoration of postoperative limb length discrepancy was classified into three groups: ± 3 mm, ± 5 mm, and ± 10 mm. This assessment was performed through a digital method 2D based on a standard hip X-ray. RESULTS: This court of 800 implants showed that planning was exact in 60% of the cups and 44% of the stems and was accurate in 94% of the cups and 80% of the stems. The postoperative limb length discrepancy was ± 3 mm in 91% and ± 5 mm in 97%. CONCLUSIONS: This study showed preoperative 2D digital planning great precision and reliability, and we demonstrated that it was accurate in 94% of the cups and 80% of the stems. Therefore, the preoperative limb length discrepancy analysis was essential to guarantee the recovery of the operated limb's correct length.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/métodos , Feminino , Masculino , Estudos Retrospectivos , Idoso , Pessoa de Meia-Idade , Desenho de Prótese , Desigualdade de Membros Inferiores , Idoso de 80 Anos ou mais , Adulto , Cirurgia Assistida por Computador/métodos , Articulação do Quadril/cirurgia , Articulação do Quadril/diagnóstico por imagem
3.
J Funct Morphol Kinesiol ; 9(3)2024 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-39330256

RESUMO

Background: A knee injury in an athlete leads to periods of forced exercise interruption. Myocardial work (MW) assessed by echocardiographic and cardiopulmonary exercise testing (CPET) are two essential methods for evaluating athletes during the period following injury. However, compared to pre-surgery evaluations, the variations in cardiovascular parameters and functional capacity assessed by these methods after surgery remain unclear. Methods: We evaluated 22 non-professional athletes aged 18-52, involved in prevalently aerobic or alternate aerobic/anaerobic sports activities, who were affected by a knee pathology requiring surgical treatment. The evaluation was performed at rest using transthoracic echocardiography, including MW assessment, and during exercise using CPET. Each athlete underwent the following two evaluations: the first before surgery and the second after surgery (specifically at the end of the deconditioning period). Results: Resting heart rate (HR) increased significantly (from 63.3 ± 10.85 to 71.2 ± 12.52 beats per minute, p = 0.041), while resting diastolic and systolic blood pressure, forced vital capacity, and forced expiratory volume in the first second did not show significant changes. Regarding the echocardiographic data, global longitudinal strain decreased from -18.9 ± 1.8 to -19.3 ± 1.75; however, this reduction was not statistically significant (p = 0.161). However, the global work efficiency (GWE) increased significantly (from 93.0% ± 2.9 to 94.8% ± 2.6, p = 0.006) and global wasted work (GWW) reduced significantly (from 141.4 ± 74.07 to 98.0 ± 50.9, p = 0.007). Additionally, the patients were able to perform maximal CPET at both pre- and post-surgery evaluations, as demonstrated by the peak respiratory exchange ratio and HR. However, the improved myocardial contractility (increased GWE and decreased GWW) observed at rest did not translate into significant changes in exercise parameters, such as peak oxygen consumption and the mean ventilation/carbon dioxide slope. Conclusions: After surgery, the athletes were more deconditioned (as indicated by a higher resting HR) but exhibited better resting myocardial contractility (increased GWE and reduced GWW). Interestingly, no significant changes in exercise capacity parameters, as evaluated by CPET, were found after surgery, suggesting that the improved myocardial contractility was offset by a greater degree of muscular deconditioning.

4.
Ann Jt ; 8: 32, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38529243

RESUMO

Background: Total hip arthroplasty (THA) is estimated to grow in the following decades with a consequent increase of THA revisions (rTHA). This systematic review and meta-analysis aims to compare modular and monoblock stem in rTHA surgery, focusing on clinical and radiological outcomes and complication rates. Methods: A literature search was performed using the following search strategy: ((Modular stem) OR (monolithic stem)) AND (hip review) on PubMed, Scopus, and Cochrane. Randomized controlled trials (RCTs) and observational studies (OS) compared clinical and radiological outcomes, and complication rates for monoblock and modular revision femoral stem were included. The risk of bias was assessed through the Methodological Index for Non-Randomized Studies (MINORS) score. The Review Manager (RevMan) software was used for the meta-analysis. The rate of complications was assessed using odds ratio (OR) with 95% confidence intervals (CIs). Results: The authors included 11 OS and one RCT with 3,671 participants (mean age: 68.4 years old). The mean follow-up was 46.9 months. There was no prevalence of subsidence for one type of stem. Mean subsidence was from 0.92 to 10 mm for modular stem and from 1 to 15 mm for monoblock stem. Postoperative Harris Hip Score (HHS) showed better results with modular stems without statistical significance [mean difference (MD) =1.32; 95% CI: -1.62 to 4.27; P=0.38]. No statistically significant difference was found for dislocations (OR =2.48; 95% CI: 0.67 to 9.14; P=0.17), infections (OR =1.07; 95% CI: 0.51 to 2.23; P=0.86), intraoperative fractures (OR =1.62; 95% CI: 0.42 to 6.21; P=0.48), and postoperative fractures (OR =1.60; 95% CI: 0.55 to 4.64; P=0.39). Conclusions: Modular and monoblock stems show comparable and satisfactory clinical and radiological outcomes for rTHA. Both stems are valid and effective options for managing femoral bone deficit in hip revision surgery. The main limitation of this study is the small number and low quality of enclosed studies that compared the two stems. Moreover, the modular stem is usually used for more complex cases with lower quality femoral bone stock.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA