Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Endocr Pract ; 25(5): 477-484, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30865545

RESUMO

Objective: Clinical trial data demonstrates improved glycemic control with hybrid close loop (HCL) insulin delivery systems, yet limited real-world data exists. Data from the inaugural cohort of patients initiating a HCL system (Medtronic MiniMed™ 670G, Medtronic Canada, Brampton, ON) at a university medical center was used to examine real-world utilization and glycemic control following a standardized implementation process. Methods: Data from 34 adult patients with type 1 diabetes were obtained from pump downloads at 4 time points: (1) previous insulin pump, (2) HCL in manual-mode, (3) 2 weeks after HCL auto-mode transition, and (4) 6 to 12 weeks after initiation of HCL. In-person training by certified diabetes educators was performed across 3 sessions with phone and electronic messaging following auto-mode start. Results: Mean self-monitored blood glucose (SMBG) per day increased from 5.15 baseline to 6.49 at 6 to 12 weeks (P<.05) with 3.26 sensor calibrations per day. Time-in-auto-mode was 79.3% at 2 weeks and 72.3% at final follow-up, with 82% of patients spending >50% of time in auto-mode. There were 8.2 auto-mode exits over the final 14-day download. Time-in-target was 67.3% in manual-mode, 73.4% at 2 weeks (P = .09), and 71.7% by 6 to 12 weeks (P = .06). Hemoglobin A1c (HbA1c) decreased by 0.51% (P = .02), while total daily dose and % basal did not change. Patients with HbA1c <7.0% (53 mmol/mol) at baseline spent more time-in-target than those with HbA1c ≥7.0% (53 mmol/mol; 78.0% versus 67.5%) despite spending less time-in-auto-mode (66.5% versus 74.8%). Conclusion: These data illustrate real-world implementation of HCL technology using a structured education program within a major medical center. Overall benefit may vary based on baseline characteristics such as HbA1c. Abbreviations: CDE = certified diabetes educator; HbA1c = hemoglobin A1c; HCL = hybrid closed loop; SMBG = self-monitored blood glucose.


Assuntos
Diabetes Mellitus Tipo 1 , Insulina/metabolismo , Glicemia , Hemoglobinas Glicadas , Humanos , Hipoglicemiantes , Sistemas de Infusão de Insulina
2.
J Diabetes Sci Technol ; : 19322968241234948, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38557128

RESUMO

BACKGROUND: Clinical trials have demonstrated the efficacy and safety of hybrid closed-loop (HCL) systems, yet few studies have compared outcomes in the real-world setting. METHOD: This retrospective study analyzed patients from an academic endocrinology practice between January 1, 2018, and November 18, 2022. The inclusion criteria were diagnosis code for type I diabetes (T1D), >18 years of age, new to any HCL system [Medtronic 670G/770G (MT), Tandem Control IQ (CIQ), or Omnipod 5 (OP5)], and availability of a pump download within three months. The outcomes included %time in range (TIR) of 70 to 180 mg/dL, %time below range (TBR) <70 mg/dL at 90 days, and HbA1c for 91 to 180 days. RESULT: Of the 176 participants, 47 were MT, 74 CIQ, and 55 OP5. Median (25%, 75%) change in HbA1c was -0.1 (-0.8, 0.3), -0.6 (-1.1, -0.15), and -0.55 (-0.98, 0)% for MT, CIQ, and OP5, respectively, (P = .04). TIR was 70 (57, 76), 67 (59, 75), and 68 (60, 76)% (P = .95) at 90 days while TBR was 2 (1, 3), 1 (0, 2), and 1 (0, 1)%, respectively, (P = .002). The %time in automated delivery was associated with TIR and change in HbA1c. After controlling other factors including %time in automated delivery, HCL type was not an independent predictor of change in HbA1c nor TIR but remained a significant predictor of TBR. CONCLUSION: There were significant reductions in HbA1c in CIQ and OP5. TIR was similar across pumps, but TBR was highest with MT. The %time in automated delivery likely explains differences in change in HbA1c but not TBR between HCL systems.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA