Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Radiol Med ; 129(4): 549-557, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38512608

RESUMO

Liver steatosis is the most common chronic liver disease and affects 10-24% of the general population. As the grade of disease can range from fat infiltration to steatohepatitis and cirrhosis, an early diagnosis is needed to set the most appropriate therapy. Innovative noninvasive radiological techniques have been developed through MRI and US. MRI-PDFF is the reference standard, but it is not so widely diffused due to its cost. For this reason, ultrasound tools have been validated to study liver parenchyma. The qualitative assessment of the brightness of liver parenchyma has now been supported by quantitative values of attenuation and scattering to make the analysis objective and reproducible. We aim to demonstrate the reliability of quantitative ultrasound in assessing liver fat and to confirm the inter-operator reliability in different respiratory phases. We enrolled 45 patients examined during normal breathing at rest, peak inspiration, peak expiration, and semi-sitting position. The highest inter-operator agreement in both attenuation and scattering parameters was achieved at peak inspiration and peak expiration, followed by semi-sitting position. In conclusion, this technology also allows to monitor uncompliant patients, as it grants high reliability and reproducibility in different body position and respiratory phases.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Humanos , Hepatopatia Gordurosa não Alcoólica/diagnóstico , Hepatopatia Gordurosa não Alcoólica/patologia , Reprodutibilidade dos Testes , Fígado/diagnóstico por imagem , Ultrassonografia/métodos , Cirrose Hepática/patologia , Imageamento por Ressonância Magnética/métodos
2.
Semin Musculoskelet Radiol ; 27(2): 153-162, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37011616

RESUMO

Anatomical variants of the long head of biceps (LHB) tendon are widely discussed in the literature. As one of the few intra-articular tendons, magnetic resonance arthroscopy can quickly evaluate the proximal part of LHB morphology. It provides good assessment of both intra-articular and extra-articular portions of the tendons. In-depth knowledge about imaging of the anatomical LHB variants discussed in this article is useful preoperatively for orthopaedists and also helps avoid potential diagnostic misinterpretations.


Assuntos
Articulação do Ombro , Tendões , Humanos , Tendões/diagnóstico por imagem , Tendões/anatomia & histologia , Artroscopia , Imageamento por Ressonância Magnética/métodos , Articulação do Ombro/diagnóstico por imagem
3.
Semin Musculoskelet Radiol ; 27(2): 198-205, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37011620

RESUMO

Several anatomical variants have been described in the knee. These variants may involve intra- and extra-articular structures, such as menisci, ligaments, plicae, bony structures, muscles, and tendons. They have a variable prevalence, are generally asymptomatic, and are usually discovered incidentally in knee magnetic resonance imaging examinations. A thorough knowledge of these findings is essential to avoid overestimating and overinvestigating normal findings. This article reviews most anatomical variants around the knee, describing how to avoid misinterpretation.


Assuntos
Traumatismos do Joelho , Articulação do Joelho , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/patologia , Imageamento por Ressonância Magnética/métodos , Tendões/diagnóstico por imagem , Ligamentos , Ligamentos Articulares/diagnóstico por imagem
4.
Radiol Med ; 128(1): 93-102, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36562906

RESUMO

PURPOSE: The aim of this multicentric study was to assess which imaging method has the best inter-reader agreement for glenoid bone loss quantification in anterior shoulder instability. A further aim was to calculate the inter-method agreement comparing bilateral CT with unilateral CT and MR arthrography (MRA) with CT measurements. Finally, calculations were carried out to find the least time-consuming method. METHOD: A retrospective evaluation was performed by 9 readers (or pairs of readers) on a consecutive series of 110 patients with MRA and bilateral shoulder CT. Each reader was asked to calculate the glenoid bone loss of all patients using the following methods: best fit circle area on both MRA and CT images, maximum transverse glenoid width on MRA and CT, CT PICO technique, ratio of the maximum glenoid width to height on MRA and CT, and length of flattening of the anterior glenoid curvature on MRA and CT. Using Pearson's correlation coefficient (PCC), the following agreement values were calculated: the inter-reader for each method, the inter-method for MRA with CT quantifications and the inter-method for CT best-fit circle area and CT PICO. Statistical analysis was carried out to compare the time employed by the readers for each method. RESULTS: Inter-reader agreement PCC mean values were the following: 0.70 for MRA and 0.77 for CT using best fit circle diameter, 0.68 for MRA and 0.72 for CT using best fit circle area, 0.75 for CT PICO, 0.64 for MRA and 0.62 for CT anterior straight line and 0.49 for MRA and 0.43 for CT using length-to-width ratio. CT-MRA inter-modality PCC mean values were 0.9 for best fit circle diameter, 0.9 for best fit circle area, 0.62 for anterior straight line and 0.94 for length-to-width methods. PCC mean value comparing unilateral CT with PICO CT methods was 0.8. MRA best fit circle area method was significantly faster than the same method performed on CT (p = 0.031), while no significant difference was seen between CT and MRA for remaining measurements. CONCLUSIONS: CT PICO is the most reliable imaging method, but both CT and MRA can be reliably used to assess glenoid bone loss. Best fit circle area CT and MRA methods are valuable alternative measurement techniques.


Assuntos
Doenças Ósseas Metabólicas , Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Humanos , Ombro , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Reprodutibilidade dos Testes , Luxação do Ombro/diagnóstico por imagem
5.
Skeletal Radiol ; 51(10): 2017-2025, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35460041

RESUMO

OBJECTIVE: Evaluating humeral head bone profile inside biceps reflection pulley area in order to identify possible anatomical variants and any causes predisposing to tendon's instability of the long head of the biceps. MATERIALS AND METHODS: This retrospective study analyzed 326 patients, 183 males and 143 females (age 15-88 years; average 51.5 years), who underwent MRI examination between 2013 and 2019. Biceps pulley reflection area morphology of 192 right shoulders and 134 left shoulders was assessed analyzing 309 MRI and 17 MR arthrography (MRA) shoulder exams. We investigated age and gender and the frequency of morphological variants among the patient groups. RESULTS: Four possible morphological variants were identified: 95 with convex shape; 127 with flat shape; 77 with spiculated shape; and 12 with mixed morphology. Fifteen humeral bone profiles were not classifiable. CONCLUSIONS: MRI was effective in defining humeral head anatomic variants inside the biceps pulley reflection area. The most frequent variants were flat or convex types.


Assuntos
Instabilidade Articular , Articulação do Ombro , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Cabeça do Úmero/diagnóstico por imagem , Instabilidade Articular/etiologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Articulação do Ombro/anatomia & histologia , Articulação do Ombro/diagnóstico por imagem , Adulto Jovem
6.
Skeletal Radiol ; 50(9): 1863-1871, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33733694

RESUMO

OBJECTIVE: The aim of this work was to evaluate the inter-observer agreement and diagnostic performance values of 7 MRI signs (3 known and 4 new) of long head biceps tendon instability. MATERIALS AND METHODS: MRI of 86 patients were retrospectively evaluated. Inter-observer agreement and diagnostic performance of each diagnostic sign and of all combined signs (with the exception of detour sign) were tested for identification of biceps tendon instability, with arthroscopy as the reference standard. RESULTS: Agreement between expert operators was moderate to good. Sensitivity, specificity, and sign accuracy showed a variation respectively of the following: humeral chondral print 72-80%, 62-68%, and 70-76%; subchondral bone edema 24-31%, 84-97%, and 50%; biceps tendon angle 60-71%, 97-100%, and 74-81%, biceps tendon-groove distance 31-47%, 90-100%, and 56-64%; long head biceps subluxation/dislocation on axial plane 49-53%, 97-100%, and 66-70%; displacement sign 74-80%, 74-100%, and 74-87%; detour sign 51-64%, 58-81%, and 62-64%; and all signs 98-100%, 32-61%, and 75-86%. CONCLUSION: These diagnostic signs, both known and new, individually and/or in combination, provide a valid tool in the MRI diagnosis of long head biceps tendon instability.


Assuntos
Instabilidade Articular , Articulação do Ombro , Artroscopia , Humanos , Instabilidade Articular/diagnóstico por imagem , Imageamento por Ressonância Magnética , Estudos Retrospectivos , Tendões/diagnóstico por imagem
7.
Knee Surg Sports Traumatol Arthrosc ; 29(7): 2348-2355, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33074421

RESUMO

PURPOSE: Unrecognized posterior shoulder dislocation with a concomitant humeral head fracture affects joint function and no consensus exists regarding treatment. The present study analyses clinical and radiographic outcomes of a novel arthroscopic technique for reducing chronic locked posterior shoulder dislocation associated with subscapularis remplissage. METHODS: The study comprises a retrospective analysis of consecutive chronic posterior locked shoulders (CPLS) with minimum 2-years follow-up of patients who had undergone McLaughlin technique arthroscopic modification for the treatment of CPLS with a reverse Hill-Sachs lesion. Active range of motion (ROM), Western Ontario (WOSI) and Constant Score (CS), were evaluated pre- and postoperatively. Plain radiographs and magnetic resonance imaging (MRI) scans were collected pre- and post-operatively, recording bone defect, osteoarthritis, cuff integrity/fatty infiltration, and the grade of filling of the reverse Hill-Sachs. RESULTS: Twelve male patients with a mean follow-up of 37.3 months ± 10.5 (range, 24-58) were included. Mean WOSI and CS scores improved from 41 to 92 and 28 to 94 points, respectively. ROM measurements all had significantly increased at final follow-up, with no significant differences in arm rotation. No defects were left unfilled at final MRI examination. CONCLUSION: The results of this uncontrolled study with a limited number of patients confirm that arthroscopic reduction and subscapularis remplissage is a highly effective and satisfactory treatment method resulting in no shoulder rotation deficits. LEVEL OF EVIDENCE: Level IV.


Assuntos
Artroscopia/métodos , Complicações Pós-Operatórias/epidemiologia , Manguito Rotador/cirurgia , Luxação do Ombro/cirurgia , Adulto , Artroscopia/efeitos adversos , Humanos , Cabeça do Úmero/cirurgia , Instabilidade Articular/cirurgia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Osteoartrite/epidemiologia , Amplitude de Movimento Articular , Estudos Retrospectivos , Rotação , Manguito Rotador/diagnóstico por imagem , Luxação do Ombro/diagnóstico por imagem , Luxação do Ombro/fisiopatologia , Fraturas do Ombro/cirurgia , Articulação do Ombro/fisiopatologia , Articulação do Ombro/cirurgia , Resultado do Tratamento , Adulto Jovem
8.
J Shoulder Elbow Surg ; 30(5): 1107-1116, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32835804

RESUMO

BACKGROUND: The main aim of this study was to evaluate the performance of magnetic resonance imaging (MRI) and interobserver agreement in the identification of the comma sign. The second objective was to look for a correlation between the comma sign and the detachment of the superficial fascia of the subscapularis. MATERIALS AND METHODS: Two radiologists, blinded to the arthroscopic findings, retrospectively assessed the magnetic resonance images of 110 shoulders and were asked to assess the presence of the comma sign and the intact subscapularis fascia. The inter-reader agreement and the MRI performance values for detection of the comma sign were calculated. In addition, the association between the intact superficial subscapularis fascia and the comma sign was evaluated. RESULTS: The agreement between the 2 radiologists was perfect. The following values were obtained: sensitivity, 90.9%; specificity, 98.8%; positive predictive value, 95.2%; negative predictive value, 97.7%; and accuracy, 97.2%. No association between the comma sign and subscapularis fascia lesions was found. CONCLUSION: MRI appears to be a reliable method for preoperative assessment of the comma sign. The comma sign appears not to be formed by the detached subscapularis fascia.


Assuntos
Lesões do Manguito Rotador , Traumatismos dos Tendões , Artroscopia , Humanos , Imageamento por Ressonância Magnética , Estudos Retrospectivos , Manguito Rotador , Lesões do Manguito Rotador/diagnóstico por imagem
9.
Radiol Med ; 126(8): 1106-1116, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34081270

RESUMO

BACKGROUND: The posteromedial meniscal region is gaining interest among orthopedic surgeons, as lesions of this area has been reported to be significantly associated with anterior cruciate ligament tears. The current imaging literature is unclear. PURPOSE: To evaluate the diagnostic performance of MR in the detection of meniscal ramp lesions having arthroscopy as reference standard. MATERIALS AND METHODS: We retrospectively included 56 patients (mean age of 25 ± 7 years; 14 females) from January to November 2017 with a arthroscopically proved ACL tear and posterior meniscocapsular separation. On preoperative MRI, two radiologists with 13 and 2 years' experience in musculoskeletal imaging assessed the presence/absence of ramp lesion, meniscotibial ligament lesion, peripheral meniscal lesion, or their combination, bone bruise. Having arthroscopy as reference standard, diagnostic performance of MRI in the evaluation of ramp area lesions was calculated. Cohen's kappa (k) and Fisher's Exact Test statistics were used. RESULTS: Agreement between radiologists ranged from κ = 0.784 (meniscotibial ligament lesions) to κ = 0.918 red-red meniscal lesion. Sensitivities were 97.4% for ramp lesions, 95.8% for meniscotibial ligament lesion, 94.4% for peripheral meniscal lesions; specificities were 88.9%, 81.3%, and 97.4%, respectively; accuracies were 94.6%, 87.5%, and 96.4%, respectively. Agreement between MR and arthroscopy was almost perfect in identification of ramp lesions (κ = 0.871) and red-red zone meniscal lesions (κ = 0.908). The agreement between the two methods was substantial (κ = 0.751) for meniscotibial lesion. No significant association between tibial plateau bone bruise and the different type of lesions was found (κ ≥ 0.004 and p ≥ 0.08). CONCLUSION: MR has high diagnostic performance in meniscal ramp area lesion assessment, with substantial to almost perfect inter-reader agreement.


Assuntos
Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Artroscopia/métodos , Imageamento por Ressonância Magnética , Lesões do Menisco Tibial/diagnóstico por imagem , Adolescente , Adulto , Feminino , Humanos , Masculino , Padrões de Referência , Estudos Retrospectivos , Adulto Jovem
10.
Eur Radiol ; 30(2): 903-913, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31529252

RESUMO

BACKGROUND: Image-guided interventional procedures around the shoulder are commonly performed in clinical practice, although evidence regarding their effectiveness is scarce. We report the results of a Delphi method review of evidence on literature published on image-guided interventional procedures around the shoulder with a list of clinical indications. METHODS: Forty-five experts in image-guided musculoskeletal procedures from the ESSR participated in a consensus study using the Delphic method. Peer-reviewed papers regarding interventional procedures around the shoulder up to September 2018 were scored according to the Oxford Centre for Evidence-based Medicine levels of evidence. Statements on clinical indications were constructed. Consensus was considered as strong if more than 95% of experts agreed and as broad if more than 80% agreed. RESULTS: A total of 20 statements were drafted, and 5 reached the highest level of evidence. There were 10 statements about tendon procedures, 6 about intra-articular procedures, and 4 about intrabursal injections. Strong consensus was obtained in 16 of them (80%), while 4 received broad consensus (20%). CONCLUSIONS: Literature evidence on image-guided interventional procedures around the shoulder is limited. A strong consensus has been reached for 80% of statements. The ESSR recommends further research to potentially influence treatment options, patient outcomes, and social impact. KEY POINTS: • Expert consensus produced a list of 20 evidence-based statements on clinical indications of image-guided interventional procedures around the shoulder. • The highest level of evidence was reached for five statements. • Strong consensus was obtained for 16 statements (80%), while 4 received broad consensus (20%).


Assuntos
Procedimentos Ortopédicos/métodos , Ombro/cirurgia , Cirurgia Assistida por Computador/métodos , Consenso , Técnica Delphi , Humanos , Sistema Musculoesquelético/cirurgia , Radiografia , Radiologia , Sociedades Médicas
11.
Eur Radiol ; 30(4): 2220-2230, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31844963

RESUMO

BACKGROUND: Although image-guided interventional procedures of the elbow and wrist are routinely performed, there is poor evidence in the literature concerning such treatments. Our aim was to perform a Delphi-based consensus on published evidence on image-guided interventional procedures around the elbow and wrist and provide clinical indications on this topic. METHODS: A board of 45 experts in image-guided interventional musculoskeletal procedures from the European Society of Musculoskeletal Radiology were involved in this Delphi-based consensus study. All panelists reviewed and scored published papers on image-guided interventional procedures around the elbow and wrist updated to September 2018 according to the Oxford Centre for Evidence-based Medicine levels of evidence. Consensus on statements drafted by the panelists about clinical indications was considered as "strong" when more than 95% of panelists agreed and as "broad" if more than 80% agreed. RESULTS: Eighteen statements were drafted, 12 about tendon procedures and 6 about intra-articular procedures. Only statement #15 reached the highest level of evidence (ultrasound-guided steroid wrist injections result in greater pain reduction and greater likelihood of attaining clinically important improvement). Seventeen statements received strong consensus (94%), while one received broad consensus (6%). CONCLUSIONS: There is still poor evidence in published papers on image-guided interventional procedures around the elbow and wrist. A strong consensus has been achieved in 17/18 (94%) statements provided by the panel on clinical indications. Large prospective randomized trials are needed to better define the role of these procedures in clinical practice. KEY POINTS: • The panel provided 18 evidence-based statements on clinical indications of image-guided interventional procedures around the elbow and wrist. • Only statement #15 reached the highest level of evidence: ultrasound-guided steroid wrist injections result in greater pain reduction and greater likelihood of attaining clinically important improvement. • Seventeen statements received strong consensus (94%), while broad consensus was obtained by 1 statement (6%).


Assuntos
Doença de De Quervain/terapia , Tendinopatia do Cotovelo/terapia , Radiografia Intervencionista , Dedo em Gatilho/terapia , Ultrassonografia de Intervenção , Técnica Delphi , Agulhamento Seco , Articulação do Cotovelo , Fluoroscopia , Glucocorticoides/administração & dosagem , Humanos , Ácido Hialurônico/administração & dosagem , Injeções , Injeções Intra-Articulares , Plasma Rico em Plaquetas , Estudos Prospectivos , Radiografia , Tenotomia , Viscossuplementos/administração & dosagem , Articulação do Punho
12.
Eur Radiol ; 30(3): 1498-1506, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31712960

RESUMO

BACKGROUND: Image-guided interventional procedures of the nerves are commonly performed by physicians from different medical specialties, although there is a lack of clinical indications for these types of procedures. This Delphi-based consensus provided a list of indications on image-guided interventional procedures for nerves of the upper limb based on updated published evidence. METHODS: An expert panel of 45 members of the Ultrasound and Interventional Subcommittees of the ESSR participated in this Delphi-based consensus study. After revision of the published papers on image-guided interventional procedures for nerves of the upper limb updated to September 2018, the experts drafted a list of statements according to the Oxford Centre for evidence-based medicine levels of evidence. Consensus on statements regarding clinical indications was considered as strong when more than 95% of experts agreed, and broad if more than 80% agreed. RESULTS: Ten statements were drafted on procedures for nerves of the upper limb. Only two statements reached the highest level of evidence (ultrasound guidance is a safe and effective method for brachial plexus block; ultrasound-guided non-surgical approaches are safe and effective methods to treat carpal tunnel syndrome in the short term, but there is sparse evidence on the mid- and long-term effectiveness of these interventions). Strong consensus was obtained on 6/10 statements (60%), while 4/10 statements reached broad consensus (40%). CONCLUSIONS: This Delphi-based consensus study reported poor evidence on image-guided interventional procedures for nerves of the upper limb. Sixty percent of statements on clinical indications provided by the expert board reached a strong consensus. KEY POINTS: • An expert panel of the ESSR provided 10 evidence-based statements on clinical indications for image-guided interventional procedures for nerves of the upper limb • Two statements reached the highest level of evidence • Strong consensus was obtained on 6/10 statements (60%), while 4/10 statements reached broad consensus (40%).


Assuntos
Consenso , Nervos Periféricos/cirurgia , Radiologia , Sociedades Médicas , Cirurgia Assistida por Computador/métodos , Ultrassonografia/métodos , Extremidade Superior/inervação , Síndrome do Túnel Carpal/diagnóstico , Síndrome do Túnel Carpal/cirurgia , Técnica Delphi , Humanos , Nervos Periféricos/diagnóstico por imagem , Radiografia , Extremidade Superior/diagnóstico por imagem
13.
Semin Musculoskelet Radiol ; 24(2): 167-174, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32438442

RESUMO

The skin, nerves, and tendons are superficial anatomical structures that can easily be investigated with an ultrasound (US) examination in the emergency department (ED). US evaluation is relatively underused in musculoskeletal evaluation when compared with other emergency applications, such as abdominal trauma, possible aortic aneurysm, and in the cardiovascular system. The aim of this article is to revise the main bone and soft tissue conditions that can be assessed using US in the ED.


Assuntos
Serviço Hospitalar de Emergência , Ultrassonografia/métodos , Ferimentos e Lesões/diagnóstico por imagem , Humanos
14.
Hell J Nucl Med ; 23(3): 264-271, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33306757

RESUMO

OBJECTIVE: Whole body low dose computed tomography (WBLDCT) is the first-choice imaging modality to identify bone involvement in multiple myeloma (MM). Because the unenhanced LDCT co-registered to positron emission tomography (PET) (LDCT/PET) has similar technical characteristics to WBLDCT, we aimed to assess its reliability in the detection of bone disease, for employing fluorine-18-fluorodeoxyglucose (18F-FDG) PET/CT as unique multimodality imaging method in MM patients. SUBJECTS AND METHODS: Thirty three consecutive MM patients were prospectively enrolled and evaluated with WBLDCT to assess bone involvement. In addition, patients underwent 18F-FDG PET/CT using a disease-tailored optimized LDCT protocol. To compare both methods, skeletal anatomical regions were identified and a per-region and per-patient analysis were performed using Cohen's k test. Low dose computed tomography/PET sensitivity, specificity and accuracy were also calculated. RESULTS: The two imaging modalities resulted highly concordant considering both patient-based (k=0.841) and region-based analysis; some discrepancies were observed in dorsal spine (k=0.809) and thorax (k=0.756). Low dose computed tomography/PET sensitivity, specificity and accuracy were 89.4%, 98.3% and 93.5%, respectively. CONCLUSION: Low dose computed tomography co-registered PET has comparable performance to WBLDCT. If confirmed on a lager sample, these encouraging results suggest the possibility to use this multimodal hybrid imaging as the only method for MM evaluation, rather than both exams, providing both morphologic and metabolic information in one session with impact on patient compliance, health care spending and especially radiation exposure.


Assuntos
Doenças Ósseas/complicações , Fluordesoxiglucose F18 , Mieloma Múltiplo/complicações , Mieloma Múltiplo/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Doses de Radiação , Imagem Corporal Total , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
15.
J Comput Assist Tomogr ; 43(3): 359-366, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30801564

RESUMO

Several complications may be encountered after rotator cuff (RC) repair. A thorough knowledge of surgical interventions, normal postoperative findings, and postoperative complications is crucial to provide a timely diagnosis, improving the clinical outcome of patients. Postoperative complications may involve RC, implanted device, osteochondral tissue, surgical-site infection, peripheral nerves, soft tissues, and vascular structures. In this review, we discuss the usual and unusual complications detectable after RC repair.


Assuntos
Complicações Pós-Operatórias/classificação , Lesões do Manguito Rotador/cirurgia , Adulto , Idoso , Comorbidade , Diagnóstico Precoce , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Lesões do Manguito Rotador/complicações , Lesões do Manguito Rotador/diagnóstico por imagem , Equipamentos Cirúrgicos/efeitos adversos , Equipamentos Cirúrgicos/microbiologia , Resultado do Tratamento
16.
Clin Anat ; 32(2): 183-195, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30113088

RESUMO

We aimed to establish the prevalence of the musculocutaneous nerve (MCN) variations and the probability of the variation being pure or mixed in the same plexus. We applied the principles of evidence-based anatomy to find, appraise, and synthesize data through a meta-analysis of anatomical studies. The variations were grouped based on the presence and location of the communicating branch with the median nerve and the origin of branches to anterior arm muscles. Forty-three cadaveric studies met the inclusion criteria, providing data from 4124 plexuses. The overall pooled prevalence of plexuses with MCN variations was 20%. Based on the classification applied in our study, the pooled prevalence of variations was 17% in region 1A, 20% in region 1B, 36% in region 2 and 49% in region 3. Importantly, 64.58% of variations in region 1A and 74.14% of variations in region 1B were mixed, that is, associated with a variation in another region. The odds of finding another variation in the presence of a variation in region 2 or 3 were equal 0.37 and 0.52, respectively, demonstrating a significantly lower probability of finding mixed variations involving these regions, when compared with region 1A. Variations of the MCN are most common in the part distal to the exit from within or beneath the coracobrachialis muscle. Proximal variations are more often associated with another variation located along the nerve. These findings can assist health care professionals in the treatment of brachial plexus lesions. Clin. Anat. 32:183-195, 2019. © 2018 Wiley Periodicals, Inc.


Assuntos
Braço/inervação , Músculo Esquelético/inervação , Nervo Musculocutâneo/anatomia & histologia , Cadáver , Feminino , Humanos , Masculino
17.
Radiol Med ; 124(11): 1167-1174, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30840189

RESUMO

Although the diagnosis of arthritis and spondyloarthritis is based on clinical criteria, today the imaging methods are an indispensable aid to the rheumatologist. Imaging has not only the task of helping early diagnosis, but it has also a fundamental role in disease grading and therapeutic monitoring. In this scenario where many publications emphasize the importance of identifying synovitis and erosions at an early stage, it is essential to know the possible pitfalls which can determine both false positives and false negatives. The high variability of the musculoskeletal system anatomy makes it necessary to have a correct knowledge of all anatomical complexes, in order not to confuse them with the pathology. Moreover, the correct and standardized method of the execution and interpretation of the exams, such as ultrasound, is crucial to identifying and correctly monitoring the pathological hallmarks of the arthritis. This paper aims to provide an instrument to radiologists, highlighting the main imaging pitfalls in ultrasound and magnetic resonance which may be encountered in daily practice.


Assuntos
Imageamento por Ressonância Magnética/métodos , Doenças Reumáticas/diagnóstico por imagem , Ultrassonografia/métodos , Diagnóstico Diferencial , Diagnóstico Precoce , Humanos , Doenças Reumáticas/patologia
18.
Radiol Med ; 124(6): 522-538, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30690662

RESUMO

Magnetic resonance imaging (MRI) is a pivotal radiological examination in clinical practice, being widely applied for musculoskeletal examinations. In this setting, strict adherence to standardized protocol is crucial to increase diagnostic performance and minimize variability among different diagnostic centres and readers. The aim of this paper is to provide standardized technical recommendations for musculoskeletal MRI scans proposed by the Italian College of Musculoskeletal Radiology. These recommendations are designed to give a uniform application of MRI protocols over the national territory, to increase reproducibility and improve diagnostic performance.


Assuntos
Protocolos Clínicos , Imageamento por Ressonância Magnética/normas , Sistema Musculoesquelético/diagnóstico por imagem , Meios de Contraste , Humanos , Itália , Reprodutibilidade dos Testes , Sociedades Médicas
19.
Future Oncol ; 14(28): 2945-2955, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29693420

RESUMO

Interventional radiology has experienced an exponential growth in the last years. Nowadays it is possible to treat painful benign lesions or metastases with optimal results in terms of pain management and disease control. Among the benign lesions, osteoid osteoma is the most frequently treated with minimal invasive techniques and the results are excellent. Another lesion, traditionally treated with surgery (osteoblastoma) represent today another field of application. In the oncological field, metastases are, numerically, the most diffuse indications for treatment. Research carried out during the last decades has provided the interventional radiologist with a great variety of techniques of ablation and devices for monitoring the sensitive structures close to the target lesion. New ablation techniques and monitoring devices contribute to the achievement of significantly increasing rates of effectiveness and safety of interventional radiology procedures.


Assuntos
Doenças Ósseas/complicações , Dor/etiologia , Dor/radioterapia , Radiologia Intervencionista , Doenças Ósseas/diagnóstico , Doenças Ósseas/etiologia , Diagnóstico por Imagem/métodos , Gerenciamento Clínico , Humanos , Manejo da Dor/métodos , Radiologia Intervencionista/métodos
20.
Int J Hyperthermia ; 34(3): 321-327, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-28597707

RESUMO

OBJECTIVE: Osteoblastoma (OB) is a painful, rare, benign bone tumour usually observed in young populations, and this condition involves the spine in up to one-third of cases. We sought to focus on the minimally invasive treatment of spinal OB with radiofrequency ablation (RFA) under computed tomography (CT) guidance. When performed near the spinal cord, surgery can lead to instability of the spine, sometimes requiring additional interventions to stabilise the segments involved, and can cause the precocious onset of arthrosis or other degenerative diseases. The results were evaluated both clinically and with the aid of diagnostic imaging techniques during a 5-year follow-up study. MATERIALS AND METHODS: Eleven patients affected by spinal OB were treated in a single session with biopsy and CT-guided RFA. Pre- and post-evaluations of the patients were performed both clinically and with CT and magnetic resonance imaging (MRI). RESULTS: Complete success in terms of pain relief was achieved in all patients. Additional treatments were not required in any patients. There were no complications. During follow-up, neither complications nor pathological findings related to the treatment were observed. CONCLUSIONS: Our experience demonstrates that RFA for spinal OB is safe and effective. One of the main advantages of this technique is represented by its lower grade of invasiveness compared with that for potentially hazardous surgical manoeuvres.


Assuntos
Osteoblastoma/radioterapia , Ablação por Radiofrequência/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoblastoma/patologia , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA