Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
J Electrocardiol ; 78: 44-48, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36758497

RESUMO

BACKGROUND: Cardiac death caused by malignant arrhythmias is very prevalent. Prolongation of the QT interval is a relevant aspect in arrhythmia mechanisms. Prior studies have revealed that the QTc interval could be shortened by cortisone. Moreover, in an animal model of long QT syndrome, cortisone treatment shortens the ventricular action potential duration. The present study investigated the effect of methylprednisolone (MPS) on the QTc interval in cardiovascularly healthy humans. METHODS: Patients who had just been diagnosed with multiple sclerosis receiving MPS therapy were analysed prospectively. Demographic data, laboratory values, anti-arrhythmic medication and baseline and follow-up ECGs were extracted from the patients' medical records. RESULTS: Seventy-eight patients were included. The mean ± standard deviation age was 47 ± 15 years. The values of the electrolytes were normal. All patients were treated with MPS for 3 or 5 days. The heart rate increased at the beginning of MPS therapy and decreased during the subsequent period. ECG measurements showed that the QTc interval was prolonged at the beginning of MPS therapy and shortened over the course of treatment. The longest QTc intervals were obtained by calculation with Bazett's formula. CONCLUSIONS: In humans, cortisone shortens the QTc interval over time. The analysis indicates a cumulative effect of cortisone that lasts longer. The results of our pilot study reveal that cortisone might be added to therapeutic strategies in patients with long QT syndromes. Further clinical studies have to be carried out to analyze potential clinical options.


Assuntos
Cortisona , Síndrome do QT Longo , Humanos , Adulto , Pessoa de Meia-Idade , Eletrocardiografia , Projetos Piloto , Síndrome do QT Longo/induzido quimicamente , Síndrome do QT Longo/diagnóstico , Síndrome do QT Longo/tratamento farmacológico , Arritmias Cardíacas/induzido quimicamente , Arritmias Cardíacas/tratamento farmacológico , Frequência Cardíaca
2.
Pacing Clin Electrophysiol ; 44(12): 1963-1971, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34586643

RESUMO

BACKGROUND: Optimization of cardiac resynchronization therapy (CRT) is often time-consuming and therefore underused in a clinical setting. Novel device-based algorithms aiming to simplify optimization include a dynamic atrioventricular delay (AVD) algorithm (SyncAV, Abbott) and multipoint pacing (MPP, Abbott). This study examines the acute effect of SyncAV and MPP on electrical synchrony in patients with newly and chronically implanted CRT devices. METHODS: Patients with SyncAV and MPP enabled devices were prospectively enrolled during implant or scheduled follow-up. Blinded 12-lead electrocardiographic acute measurements of QRS duration (QRSd) were performed for intrinsic QRSd (Intrinsic), bi-ventricular pacing (BiV), MPP, BiV with SyncAV at default offset 50 ms (BiVSyncAVdef ), BiV with SyncAV at patient-specific optimised offset (BiVSyncAVopt ), MPP with SyncAV at default offset 50 ms (MPPSyncAVdef ), and MPP with SyncAV at patient-specific optimised offset (MPPSyncAVopt ). RESULTS: Thirty-three patients were enrolled. QRSd for Intrinsic, BiV, MPP, BiVSyncAVdef , BiVSyncAVopt , MPPSyncAVdef , MPPSyncAVopt were 160.4 ± 20.6 ms, 141.0 ± 20.5 ms, 130.2 ± 17.2 ms, 121.7 ± 20.9 ms, 117.0 ± 19.0 ms, 121.2 ± 17.1 ms, 108.7 ± 16.5 ms respectively. MPPSyncAVopt led to greatest reduction of QRSd relative to Intrinsic (-31.6 ± 11.1%; p < .001), showed significantly shorter QRSd compared to all other pacing configurations (p < .001) and shortest QRSd in every patient. Shortening of QRSd was not significantly different between newly and chronically implanted devices (-51.6 ± 14.7 ms vs. -52.7 ± 21.9 ms; p = .99). CONCLUSION: SyncAV and MPP improved acute electrical synchrony in CRT. Combining both technologies with patient-specific optimization resulted in greatest improvement, regardless of time since implantation. Whats new Novel device-based algorithms like a dynamic AVD algorithm (SyncAV, Abbott) and multipoint pacing (MPP, Abbott) aim to simplify CRT optimization. Our data show that a combination of patient tailored SyncAV optimization and MPP results in greatest improvement of electrical synchrony in CRT measured by QRS duration, regardless if programmed in newly or chronically implanted devices. This is the first study to our knowledge to examine a combination of these device-based algorithms. The results help understanding the ideal ventricular excitation in heart failure.


Assuntos
Algoritmos , Terapia de Ressincronização Cardíaca/métodos , Cardiomiopatias/terapia , Idoso , Eletrocardiografia , Feminino , Alemanha , Humanos , Masculino , Estudos Prospectivos
3.
Pacing Clin Electrophysiol ; 40(4): 409-416, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28164349

RESUMO

BACKGROUND: The presence of left bundle branch block (LBBB) due to right ventricular pacing represents a particular challenge in properly measuring the QTc interval. In 2014, a new formula for the evaluation of QT interval in patients with LBBB was reported. METHODS: 145 patients with implantable cardioverter defibrillator were included in this prospective multicenter observational study. Inclusion criteria were: no permanent right ventricular stimulation, an intrinsic QRS interval of <120 ms, and reduced left ventricular function. 12-lead electrocardiogram recordings during intrinsic rhythm and during right ventricular threshold testing were performed. After LBBB correction using the reported Bogossian formula, the QTc interval was evaluated with Bazett's formula. The corrected QTc interval was compared in each patient with the QTc interval during intrinsic rhythm. All measurements were performed by an experienced electrophysiologist and a trainee who worked independently and in a blinded manner. RESULTS: 74 patients (65 ± 13 years; male n = 42) with apical and 71 patients (68 ± 11 years; male n = 42) with nonapical right ventricular pacing were included in this study. The mean left ventricular ejection fraction was 40 ± 13%. The QTc interval was determined to be 461 ± 34 ms (modified by Bogossian's formula) in paced and 436 ± 34 ms in intrinsic rhythm. The QTc interval was overestimated by ΔQTc of 25 ± 21 ms (mean deviation 5.7%) when using the Bogossian formula. CONCLUSION: The novel Bogossian formula seems to be a reliable tool for QTc interval evaluation in patients with heart failure and right ventricular pacing. However, a slight overestimation of the QT-interval must be respected.


Assuntos
Estimulação Cardíaca Artificial/efeitos adversos , Diagnóstico por Computador/métodos , Eletrocardiografia/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Síndrome do QT Longo/diagnóstico , Síndrome do QT Longo/etiologia , Idoso , Algoritmos , Feminino , Ventrículos do Coração , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Artigo em Inglês | MEDLINE | ID: mdl-27562181

RESUMO

BACKGROUND: The evaluation of the QT interval in the presence of left bundle branch block (LBBB) is associated with the challenge to discriminate native QT interval from the prolongation due to the increase in QRS duration. The newest formula to evaluate QT interval in the presence of LBBB suggests: modified QT during LBBB = measured QT interval minus 50% of LBBB duration. The purpose of this study is therefore to validate the abovementioned formula in the clinical setting. METHODS: Validation in two separate groups of patients: Patients who alternated between narrow QRS and intermittent LBBB and patients with narrow QRS who developed LBBB after transcatheter aortic valve implantation (TAVI). RESULTS: The acquired mean native QTc intervals and those calculated by the presented formula displayed no significant differences (p > .99 and p > .75). CONCLUSIONS: In this study we proved for the first time the validity and applicability of the experimentally acquired formula for the evaluation of the QT interval in the presence of LBBB in a clinical setting.


Assuntos
Bloqueio de Ramo/fisiopatologia , Eletrocardiografia/métodos , Fascículo Atrioventricular/fisiopatologia , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
5.
Ann Noninvasive Electrocardiol ; 20(6): 609-11, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25631624

RESUMO

Q waves can regularly be observed in the 12-lead electrocardiogram either due to heart axis underlying pathology such as subacute myocardial infarction, myocardial scar, or accessory pathways. Rarely, other entities such as circumscribed hypertrophy can induce significant Q wave and represent an important differential diagnosis especially in younger patients. In the setting of atypical chest pain determination of the correct diagnosis can be challenging. Therefore, circumscribed hypertrophy should be taken into account to avoid unnecessary invasive procedures.


Assuntos
Eletrocardiografia , Hipertrofia Ventricular Esquerda/diagnóstico , Hipertrofia Ventricular Esquerda/etiologia , Adulto , Cicatriz/diagnóstico , Feminino , Humanos , Infarto do Miocárdio/diagnóstico
6.
Ann Noninvasive Electrocardiol ; 20(3): 292-5, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25200520

RESUMO

The main tool for the differentiation of supraventricular tachycardia is the 12-lead electrocardiogram (ECG). Especially differentiating the atrioventricular nodal reentrant tachycardia (AVNRT) from the atrioventricular reentrant tachycardia (AVRT) due to concealed accessory pathway or from an atrial tachycardia (AT) is very important for catheter setting and ablation approach in an electrophysiological study. In our case we saw the occurrence of a U wave during tachycardia-simulating a pseudo P wave. This mimicked a long RP-tachycardia, although it was a common type AVNRT.


Assuntos
Eletrocardiografia , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade
8.
J Clin Med ; 13(4)2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38398357

RESUMO

BACKGROUND: Cephalic vein cutdown (CVC) and subclavian vein puncture (SVP) are the most commonly used access sites for transvenous lead placement of cardiac implantable electronic devices (CIEDs). Limited knowledge exists about the long-term patency of the vascular lumen housing the leads. METHODS: Among the 2703 patients who underwent CIED procedures between 2005 and 2013, we evaluated the phlebographies of 162 patients scheduled for an elective CIED replacement (median of 6.4 years after the first operation). The phlebographies were divided into four stenosis types: Type I = 0%, Type II = 1-69%, Type III = 70-99%, and Type IV = occlusion. Due to the fact that no standardized stenosis categorization exists, experienced physicians in consensus with the involved team made the applied distribution. The primary endpoint was the occurrence of stenosis Type III or IV in the CVC group and in the SVP group. RESULTS: In total, 162 patients with venography were enrolled in this study. The prevalence of high-degree stenosis was significantly lower in the CVC group (7/89, 7.8%) than in the SVP group (15/73, 20.5%, p = 0.023). In the CVC group, venographies showed a lower median stenosis (33%) than in the SVP group (median 42%). CONCLUSIONS: The present study showed that the long-term patency of the subclavian vein is higher after CVC than after SVP for venous access in patients with CIED.

10.
Front Cardiovasc Med ; 10: 1084051, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37139131

RESUMO

Background: In patients with pulmonary hypertension (PH), increased pulmonary vascular resistance (PVR) may lead to increased right ventricular afterload and cardiac remodelling, potentially providing the substrate for ventricular arrhythmias. Studies dealing with long term monitoring of patients with PH are rare. The present study evaluated the incidence and the types of arrhythmias retrospectively recorded by Holter ECG in patients with newly detected PH during a long-term Holter ECG follow-up. Moreover, their impact on patient survival was evaluated. Patients and methods: Medical records were screened for demographic data, aetiology of PH, incidence of coronary heart disease, level of brain natriuretic peptide (BNP), results from Holter ECG monitoring, 6-minute walk test distance, echocardiographic data and hemodynamic data derived from right heart catheterization. Two subgroups were analyzed: 1. patients (n = 65) with PH (group 1 + 4) and derivation of at least 1 Holter ECG within 12 months from initial detection of PH and 2. patients (all PH etiologies, n = 59) with 3 follow-up Holter ECGs. The frequency and complexity of premature ventricular contractions (PVC) was classified into "lower" and "higher" (=non sustained ventricular tachycardia, nsVT) burden. Results: Holter ECG revealed sinus rhythm (SR) in most of the patients (n = 60). Incidence of atrial fibrillation (AFib) was low (n = 4). Patients with premature atrial contractions (PAC) tend to have a shorter period of survival (p = 0.098), PVC were not correlated with significant survival differences. During follow-up PAC and PVC were common in all PH groups. Holter ECG revealed non sustained ventricular tachycardia in 19/59 patients [(32.2%); n = 6 during first Holter-ECG, n = 13 during second/third Holter-ECG]. In all patients suffering from nsVT during follow-up previous Holter ECG revealed multiform/repetitive PVC. PVC burden was not linked to differences in systolic pulmonary arterial pressure, right atrial pressure, brain natriuretic peptide and results of six-minute walk test. Conclusion: Patients with PAC tend to have a shortened survival. None of the evaluated parameters (BNP, TAPSE, sPAP) was correlated with the development of arrhythmias. Patients with multiform/repetitive PVC seem to be at risk for ventricular arrhythmias.

11.
J Interv Card Electrophysiol ; 66(4): 857-863, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35107720

RESUMO

PURPOSE: The cephalic vein cutdown (CVC) and the subclavian puncture (SP) is the most common access for pacemaker implantation. The purpose of this study was to compare the peri-/postoperative complications of these approaches. METHODS: A retrospective analysis of the quality assurance data of the state of North Rhine-Westphalia was performed to evaluate the peri-/postoperative complications of first pacemaker implantation according to the venous access. The primary endpoint was defined as the occurrence of one of the following: asystole, ventricular fibrillation, pneumothorax, hemothorax, pericardial effusion, pocket hematoma, lead dislocation, lead dysfunction, postoperative wound infection or other complication requiring intervention. Descriptive analysis was done via absolute, relative frequencies and Odds Ratio. Fisher's exact test was used for comparison of the both study groups. RESULTS: From 139,176 pacemaker implantations from 2010 to 2014, 15,483 cases were excluded due to other/double access. The median age was 78 years and the access used was CVC for 75,251 cases (60.8%) and SP for 48,442 cases (39.2%). The implanted devices were mainly dual-chamber pacemakers (73.9% in the CVC group and 78.4% in the SP group), followed by single-chamber pacemakers VVI (24.9% and 19.9% in the CVC and SP group respectively). There were significantly fewer peri/postoperative complications in the CVC group compared to the SP group (2.49% vs. 3.64%, p = 0.0001, OR 1.47; 95% CI 1.38-1.57). CONCLUSIONS: CVC as venous access for pacemaker implantation has significantly fewer peri/postoperative complications than SP and appears to be an advantageous technique.


Assuntos
Marca-Passo Artificial , Veia Subclávia , Humanos , Idoso , Venostomia/métodos , Estudos Retrospectivos , Punções
12.
Int J Cardiol Heart Vasc ; 46: 101203, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37091914

RESUMO

Background: With 900'000 coronary angiographies (CA) per year, Germany has the highest annual per capita volume in Europe. Until now there are no prospective clinical data on the degree of guideline-adherence in the use of CA in patients with suspected chronic coronary syndrome (CCS) in Germany. Methods: Between January 2019 and August 2021, 458 patients with suspected CCS were recruited in nine German centres. Guideline-adherence was evaluated according to the current European Society of Cardiology and German guidelines. Pre-test probability (PTP) for CAD was determined using age, gender, and a standardized patient questionnaire to identify symptoms. Data on the diagnostic work-up were obtained from health records. Results: Patients were in mean 66.6 years old, male in 57.3 %, had known CAD in 48.4 % and presented with typical, atypical, non-anginal chest pain or dyspnoea in 35.7 %, 41.3 %, 23.0 % and 25.4 %, respectively. PTP according to the European guidelines was in mean 24.2 % (11.9 %-36.5 % 95 % CI). 20.9 % of the patients received guideline-recommended preceding non-invasive image guided testing. The use of CA was adherent to the European and German guideline recommendations in 20.4 % and 25.4 %, respectively. In multivariate-analysis, arterial hypertension and prior revascularization were predictors of guideline non-adherence. Conclusion: These are the first prospective clinical data which demonstrated an overall low degree of guideline-adherence in the use of CA in patients with suspected CCS in the German health care setting. To improve adherence rates, the availability of and access to non-invasive image guided testing needs to be strengthened. (German Clinical Trials Registry DRKS00015638 - Registration Date: 19.02.2019).

14.
Front Cardiovasc Med ; 9: 981985, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36119735

RESUMO

Introduction: The Electrical storm (ES) subsumes a state of electrical instability of the heart, which manifests itself in repeated and potentially fatal ventricular arrhythmias (VA). We examine the long-term effects of substrate modification with regards to mortality, ventricular tachycardia (VT) recurrences and hospitalization depending on age, gender, heart function, scare location, VT documentation, postprocedural electrical stimulation (PES) and induced VTs. Methods: From 08/2008 and 09/2019 160 consecutive patients admitted for ES ablation via electroanatomical mapping were followed up until 04/2021. Results: 50/160 patients showed VT recurrences after 13.8 ± 21.7 (0.0-80.3) months, with a characteristic steep curve directly after ES and then a rapid decline leading to a plateau (first month 10/50 (20%), first year 35/50 VT recurrences (70%) Mortality rates followed a similar pattern also the initial decline was not as steep. 42 patients died during the observation period (26%) after 16.6 ± 16.1 (0.0-67.9) months after ablation day (first month (n = 7, 16.7%) first year (n = 21, 50%). Gender, age, scare localization, missing VT documentation did not worsen outcome. Induction of >3 VTs and lack of PES due to hemodynamic instability significantly decreased effectiveness. Finding the entry significantly increased long-term effects. Conclusion: Ablation of ES is safe and feasible independent of a variety of factors. Employing more sophisticated tools to understand the reentry mechanism will further improve the long-term outcome.

15.
Clin Res Cardiol ; 111(5): 502-510, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-33770204

RESUMO

BACKGROUND: The short-coupled variant of torsade de pointes (sc-TdP) is a malignant arrhythmia that frequently presents with ventricular fibrillation (VF) electrical storm. Verapamil is considered the first-line therapy of sc-TdP while catheter ablation is not widely adopted. The aim of this study was to determine the origin of sc-TdP and to assess the outcome of catheter ablation using 3D-mapping. METHODS AND RESULTS: We retrospectively analyzed five patients with sc-TdP who underwent 3D-mapping and ablation of sc-TdP at five different institutions. Four patients initially presented with sudden cardiac arrest, one patient experienced recurrent syncope as the first manifestation. All patients demonstrated a monomorphic premature ventricular contraction (PVC) with late transition left bundle branch block pattern, superior axis, and a coupling interval of less than 300 ms. triggering recurrent TdP and VF. In four patients, the culprit PVC was mapped to the free wall insertion of the moderator band (MB) with a preceding Purkinje potential in two patients. Catheter ablation using 3D-mapping and intracardiac echocardiography eliminated sc-TdP in all patients, with no recurrence at mean 2.7 years (range 6 months to 8 years) of follow-up. CONCLUSION: 3D-mapping and intracardiac echocardiography demonstrate that sc-TdP predominantly originates from the MB free wall insertion and its Purkinje network. Catheter ablation of the culprit PVC at the MB free wall junction leads to excellent short- and long-term results and should be considered as first-line therapy in recurrent sc-TdP or electrical storm.


Assuntos
Ablação por Cateter , Torsades de Pointes , Complexos Ventriculares Prematuros , Humanos , Ablação por Cateter/métodos , Proteínas de Ligação a DNA , Eletrocardiografia , Estudos Retrospectivos , Torsades de Pointes/diagnóstico , Torsades de Pointes/etiologia , Fibrilação Ventricular , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
16.
J Interv Card Electrophysiol ; 61(2): 415-419, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32725360

RESUMO

PURPOSE: We sought to establish the technical feasibility of VT-mapping with high-density catheters in patients with Mitraclips, requiring a hemodynamic support. METHODS: A 73-year-old man with ischemic cardiomyopathy and reduced left ventricular ejection fraction (LVEF ~ 20%) was presented due to syncope and adequate shock of his ICD. Due to severe mitral valve regurgitation (MR), two Mitraclips were implanted earlier. The decision for catheter ablation was made in line with current guidelines. Given the increased PAAINESD score, the use of hemodynamic support was required. To employ an Impella pump via the retrograde transaortic approach, LV-mapping and VT-ablation were necessary to be performed via the transseptal approach, which was challenging due to the presence of Mitraclips. The MV passage with the steerable sheath was guided by a quadripolar catheter and 3D transoesophageal echo (TEE). After the 12F steerable sheath had passed the MV, the quadripolar catheter was exchanged by a high-density (HD) Grid® catheter. Hereafter, the Impella pump was placed retrogradely in the LV, and voltage-mapping of the LV and ablation was performed. RESULTS: At the end of the procedure, the Impella pump could be removed in stable hemodynamic conditions. The follow-up after 3, 6, and 12 months showed no new VT episodes. CONCLUSIONS: This case demonstrates the feasibility of the transseptal approach of VT mapping used HD Grid catheter and retrograde hemodynamic support with Impella Pump for VT treatment in patients after Mitraclips implantation. To avoid a damage of the MV and Mitraclips, 3D-TEE is advisable.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Idoso , Catéteres , Hemodinâmica , Humanos , Masculino , Volume Sistólico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento , Função Ventricular Esquerda
17.
J Cardiovasc Electrophysiol ; 21(2): 193-9, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19804547

RESUMO

INTRODUCTION: The right inferior ganglionated plexus (RIGP) selectively innervates the atrioventricular node. Temporary electrical stimulation of this plexus reduces the ventricular rate during atrial fibrillation (AF). We sought to assess the feasibility of chronic parasympathetic stimulation for ventricular rate control during AF with a nonthoracotomy intracardiac neurostimulation approach. METHODS AND RESULTS: In 9 mongrel dogs, the small endocardial area inside the right atrium, which overlies the RIGP, was identified by 20 Hz stimulation over a guiding catheter with integrated electrodes. Once identified, an active-fixation lead was implanted. The lead was connected to a subcutaneous neurostimulator. An additional dual-chamber pacemaker was implanted for AF induction by rapid atrial pacing and ventricular rate monitoring. Continuous neurostimulation was delivered for 1-2 years to decrease the ventricular rate during AF to a range of 100-140 bpm. Implantation of a neurostimulation lead was achieved within 37 +/- 12 min. The latency of the negative dromotropic response after on/offset or modulation of neurostimulation was <1 s. Continuous neurostimulation was effective and well tolerated during a 1-2 year follow-up with a stimulation voltage <5 V. The neurostimulation effect displayed a chronaxie-rheobase behavior (chronaxie time of 0.07 +/- 0.02 ms for a 50% decrease of the ventricular rate during AF). CONCLUSION: Chronic parasympathetic stimulation can be achieved via a cardiac neurostimulator. The approach is safe, effective, and well tolerated in the long term. The atrioventricular nodal selectivity and the opportunity to adjust the negative dromotropic effect within seconds may represent an advantage over pharmacological rate control.


Assuntos
Fibrilação Atrial/prevenção & controle , Fibrilação Atrial/fisiopatologia , Terapia por Estimulação Elétrica/métodos , Gânglios Parassimpáticos/fisiopatologia , Frequência Cardíaca , Ventrículos do Coração/fisiopatologia , Animais , Cães , Estudos de Viabilidade , Masculino , Toracotomia , Resultado do Tratamento
18.
J Thromb Thrombolysis ; 30(1): 90-6, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19921100

RESUMO

To investigate the prevalence of permanent atrial fibrillation (AF), its clinical associated conditions and treatment status in the elderly population in rural Greece. 720 people (46.1% males) older than 65 years (mean age: 72.5 +/- 5.7 years) living in four villages in rural Greece were screened with an electrocardiogram (response rate: 90.5%) for the presence of permanent AF. They underwent a physical examination, including blood pressure (BP) measurement, and body mass index (BMI) calculation, in addition to an interview about their medical history, physical activity, smoking habits, alcohol consumption and medication use. Subjects with AF for whom anticoagulants were contraindicated were identified and stroke risk stratification was performed using the CHADS2 algorithm. The prevalence of permanent AF was 5% (6.6% among men and 3.6% among women) and it increased with age. In the entire population, ECG evidence of myocardial ischaemia and ventricular premature beats were independently associated with the presence of permanent AF (OR 5.266; 95% CI 2.22-12.49, P = 0.0001 and OR 2.61; 95% CI 1.059-6.432, P = 0.037, respectively), while female sex was independently associated with the absence of the AF (OR 0.327; CI 0.147-0.729, P = 0.006). From those patients who were eligible for anticoagulation, 40.6% were treated with anticoagulants, 34.3% were given antiplatelets therapy and the rest received no antithrombotic treatment. This is the first prospective study demonstrating the prevalence, clinical correlates and treatment status of permanent AF in Greece. These results confirm the high prevalence of permanent AF among the elderly and underscore the issue regarding anticoagulants underutilization.


Assuntos
Fibrilação Atrial/epidemiologia , Fatores Etários , Idoso , Anticoagulantes/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Feminino , Grécia/epidemiologia , Humanos , Masculino , Inibidores da Agregação Plaquetária/uso terapêutico , Prevalência , Estudos Prospectivos , População Rural
19.
Herzschrittmacherther Elektrophysiol ; 31(1): 55-63, 2020 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-32060611

RESUMO

The electrical storm (ES) defined as ≥3 sustained episodes of ventricular tachycardia within a 24 h period comprises a wide spectrum of clinical entities. Mostly patients suffer from severe heart insufficiency and comorbidities making an immediate transfer into a heart center with multidisciplinary expertise in the treatment of ES mandatory. As these patients are often traumatized by ongoing tachycardia despite multiple cardioversions, early deep sedation and ß­blockade to break the vicious circle of sympathico-adrenergic hyperactivation is very effective. Multiple ICD discharges suggesting the diagnosis of ES are inadequate in one third of cases. Pharmacological suppression, frequency control or ablation of supraventricular tachycardias (SVT) help in most cases. In some cases "oversensing" demands optimization of ICD programming. Even so not all adequate ICD discharges, however, are necessary. Since every ICD discharge worsens the patient's prognosis, any kind of ICD discharge should be prevented as far as hemodynamically feasible. After clinical stabilization of the patient with simultaneous acquisition of ECG and testing for reversible causes of ES, ES should be terminated by external or internal cardioversion followed by urgent but elective therapy. Some cases of ES, however, may require immediate escalation of therapy with emergency ablation or revascularization sometimes with circulatory support systems. If ES still persists, a further step in escalation may be taken by cardiac sympathetic denervation. Due to the poor prognosis of patients after ES, close monitoring of the patient, preferably with telemedicine, is indicated.


Assuntos
Cardioversão Elétrica , Taquicardia Ventricular , Arritmias Cardíacas , Desfibriladores Implantáveis , Humanos , Incidência
20.
Int J Cardiol Heart Vasc ; 30: 100636, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32995475

RESUMO

Proper measurement of the QT interval on the 12-lead body-surface ECG is challenging in daily practice. Even more difficult is its correct estimation in the presence of repolarization abnormalities, arrhythmias or bundle-branch blocks (BBB). The QT interval results from two parts of the ECG: (1) the QRS complex, describing the excitation of the ventricles and (2) the JT interval, describing the repolarisation of the ventricles. Prolongation of the QRS width - like in the presence of BBB - entails prolongation of the QT interval, making the estimation of the true repolarisation time challenging. The US recommendations for the standardization and interpretation of the ECG suggest focusing on the JT interval in presence of BBB. However, in clinical practice physicians have become more familiar with the interpretation of QT-interval measurements than with the interpretation of the JT Interval. In the last decade, a simple formula for the estimation of the "modified QT interval" in the presence of left or right BBB has been developed and evaluated. In this formula, the modified QT interval is calculated by subtracting 50% of the length of the BBB-QRS from the measured QT interval (QTm = QTBBB - 50% QRSBBB). Subsequently, rate-correction formula should be applied as usual. In this review, we discuss the determination of the QT-interval in the presence of BBB and summarize the origin and application of the modified QT-interval formula.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA