Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Circulation ; 145(22): 1655-1662, 2022 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-35369704

RESUMO

BACKGROUND: Previous studies have shown that quality of life improves after coronary revascularization more so after coronary artery bypass grafting (CABG) than after percutaneous coronary intervention (PCI). This study aimed to evaluate the effect of fractional flow reserve guidance and current generation, zotarolimus drug-eluting stents on quality of life after PCI compared with CABG. METHODS: The FAME 3 trial (Fractional Flow Reserve Versus Angiography for Multivessel Evaluation) is a multicenter, international trial including 1500 patients with 3-vessel coronary artery disease who were randomly assigned to either CABG or fractional flow reserve-guided PCI. Quality of life was measured using the European Quality of Life-5 Dimensions (EQ-5D) questionnaire at baseline and 1 and 12 months. The Canadian Cardiovascular Class angina grade and working status were assessed at the same time points and at 6 months. The primary objective was to compare EQ-5D summary index at 12 months. Secondary end points included angina grade and work status. RESULTS: The EQ-5D summary index at 12 months did not differ between the PCI and CABG groups (difference, 0.001 [95% CI, -0.016 to 0.017]; P=0.946). The trajectory of EQ-5D during the 12 months differed (P<0.001) between PCI and CABG: at 1 month, EQ-5D was 0.063 (95% CI, 0.047 to 0.079) higher in the PCI group. A similar trajectory was found for the EQ (EuroQol) visual analogue scale. The proportion of patients with Canadian Cardiovascular Class 2 or greater angina at 12 months was 6.2% versus 3.1% (odds ratio, 2.5 [95% CI, 0.96-6.8]), respectively, in the PCI group compared with the CABG group. A greater percentage of younger patients (<65 years old) were working at 12 months in the PCI group compared with the CABG group (68% versus 57%; odds ratio, 3.9 [95% CI, 1.7-8.8]). CONCLUSIONS: In the FAME 3 trial, quality of life after fractional flow reserve-guided PCI with current generation drug-eluting stents compared with CABG was similar at 1 year. The rate of significant angina was low in both groups and not significantly different. The trajectory of improvement in quality of life was significantly better after PCI, as was working status in those <65 years old. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02100722.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Idoso , Angina Pectoris , Canadá , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Qualidade de Vida , Resultado do Tratamento
2.
J Interv Cardiol ; 2020: 4603169, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32774184

RESUMO

With the increasing prevalence of aortic stenosis (AS) due to a growing elderly population, a proper understanding of its physiology is paramount to guide therapy and define severity. A better understanding of the microvasculature in AS could improve clinical care by predicting left ventricular remodeling or anticipate the interplay between epicardial stenosis and myocardial dysfunction. In this review, we combine five decades of literature regarding microvascular, coronary, and aortic valve physiology with emerging insights from newly developed invasive tools for quantifying microcirculatory function. Furthermore, we describe the coupling between microcirculation and epicardial stenosis, which is currently under investigation in several randomized trials enrolling subjects with concomitant AS and coronary disease. To clarify the physiology explained previously, we present two instructive cases with invasive pressure measurements quantifying coexisting valve and coronary stenoses. Finally, we pose open clinical and research questions whose answers would further expand our knowledge of microvascular dysfunction in AS. These trials were registered with NCT03042104, NCT03094143, and NCT02436655.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Circulação Coronária , Microcirculação/fisiologia , Idoso , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/terapia , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/terapia , Gerenciamento Clínico , Humanos
3.
Eur Heart J ; 39(28): 2646-2655, 2018 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-29617762

RESUMO

Aims: Echocardiography and tomographic imaging have documented dynamic changes in aortic stenosis (AS) geometry and severity during both the cardiac cycle and stress-induced increases in cardiac output. However, corresponding pressure gradient vs. flow relationships have not been described. Methods and results: We recruited 16 routine transcatheter aortic valve implantations (TAVI's) for graded dobutamine infusions both before and after implantation; 0.014″ pressure wires in the aorta and left ventricle (LV) continuously measured the transvalvular pressure gradient (ΔP) while a pulmonary artery catheter regularly assessed cardiac output by thermodilution. Before TAVI, ΔP did not display a consistent relationship with transvalvular flow (Q). Neither linear resistor (median R2 0.16) nor quadratic orifice (median R2 < 0.01) models at rest predicted stress observations; the severely stenotic valve behaved like a combination. The unitless ratio of aortic to left ventricular pressures during systolic ejection under stress conditions correlated best with post-TAVI flow improvement. After TAVI, a highly linear relationship (median R2 0.96) indicated a valid valve resistance. Conclusion: Pressure loss vs. flow curves offer a fundamental fluid dynamic synthesis for describing aortic valve pathophysiology. Severe AS does not consistently behave like an orifice (as suggested by Gorlin) or a resistor, whereas TAVI devices behave like a pure resistor. During peak dobutamine, the ratio of aortic to left ventricular pressures during systolic ejection provides a 'fractional flow reserve' of the aortic valve that closely approximates the complex, changing fluid dynamics. Because resting assessment cannot reliably predict stress haemodynamics, 'valvular fractional flow' warrants study to explain exertional symptoms in patients with only moderate AS at rest.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/fisiologia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Pressão Sanguínea , Feminino , Humanos , Masculino , Fluxo Sanguíneo Regional , Índice de Gravidade de Doença , Fatores de Tempo
4.
JMIR Mhealth Uhealth ; 12: e53964, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38832585

RESUMO

Background: Due to aging of the population, the prevalence of aortic valve stenosis will increase drastically in upcoming years. Consequently, transcatheter aortic valve implantation (TAVI) procedures will also expand worldwide. Optimal selection of patients who benefit with improved symptoms and prognoses is key, since TAVI is not without its risks. Currently, we are not able to adequately predict functional outcomes after TAVI. Quality of life measurement tools and traditional functional assessment tests do not always agree and can depend on factors unrelated to heart disease. Activity tracking using wearable devices might provide a more comprehensive assessment. Objective: This study aimed to identify objective parameters (eg, change in heart rate) associated with improvement after TAVI for severe aortic stenosis from a wearable device. Methods: In total, 100 patients undergoing routine TAVI wore a Philips Health Watch device for 1 week before and after the procedure. Watch data were analyzed offline-before TAVI for 97 patients and after TAVI for 75 patients. Results: Parameters such as the total number of steps and activity time did not change, in contrast to improvements in the 6-minute walking test (6MWT) and physical limitation domain of the transformed WHOQOL-BREF questionnaire. Conclusions: These findings, in an older TAVI population, show that watch-based parameters, such as the number of steps, do not change after TAVI, unlike traditional 6MWT and QoL assessments. Basic wearable device parameters might be less appropriate for measuring treatment effects from TAVI.


Assuntos
Substituição da Valva Aórtica Transcateter , Dispositivos Eletrônicos Vestíveis , Humanos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Feminino , Estudos Prospectivos , Dispositivos Eletrônicos Vestíveis/estatística & dados numéricos , Dispositivos Eletrônicos Vestíveis/normas , Idoso de 80 Anos ou mais , Idoso , Estenose da Valva Aórtica/cirurgia , Inquéritos e Questionários , Qualidade de Vida/psicologia
7.
BMJ Open ; 12(4): e057305, 2022 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-35383078

RESUMO

OBJECTIVE: To review, inventory and compare available diagnostic tools and investigate which tool has the best performance for prehospital risk assessment in patients suspected of non-ST-segment elevation acute coronary syndrome (NSTE-ACS). METHODS: Systematic review and meta-analysis. Medline and Embase were searched up till 1 April 2021. Prospective studies with patients, suspected of NSTE-ACS, presenting in the primary care setting or by emergency medical services (EMS) were included. The most important exclusion criteria were studies including only patients with ST-elevation myocardial infarction and studies before 1995, the pretroponin era. The primary end point was the final hospital discharge diagnosis of NSTE-ACS or major adverse cardiac events (MACE) within 6 weeks. Risk of bias was evaluated by the Quality Assessment of Diagnostic Accuracy Studies Criteria. MAIN OUTCOME AND MEASURES: Sensitivity, specificity and likelihood ratio of findings for risk stratification in patients suspected of NSTE-ACS. RESULTS: In total, 15 prospective studies were included; these studies reflected in total 26 083 patients. No specific variables related to symptoms, physical examination or risk factors were useful in risk stratification for NSTE-ACS diagnosis. The most useful electrocardiographic finding was ST-segment depression (LR+3.85 (95% CI 2.58 to 5.76)). Point-of-care troponin was found to be a strong predictor for NSTE-ACS in primary care (LR+14.16 (95% CI 4.28 to 46.90) and EMS setting (LR+6.16 (95% CI 5.02 to 7.57)). Combined risk scores were the best for risk assessment in an NSTE-ACS. From the combined risk scores that can be used immediately in a prehospital setting, the PreHEART score, a validated combined risk score for prehospital use, derived from the HEART score (History, ECG, Age, Risk factors, Troponin), was most useful for risk stratification in patients with NSTE-ACS (LR+8.19 (95% CI 5.47 to 12.26)) and for identifying patients without ACS (LR-0.05 (95% CI 0.02 to 0.15)). DISCUSSION: Important study limitations were verification bias and heterogeneity between studies. In the prehospital setting, several diagnostic tools have been reported which could improve risk stratification, triage and early treatment in patients suspected for NSTE-ACS. On-site assessment of troponin and combined risk scores derived from the HEART score are strong predictors. These results support further studies to investigate the impact of these new tools on logistics and clinical outcome. FUNDING: This study is funded by ZonMw, the Dutch Organisation for Health Research and Development. TRIAL REGISTRATION NUMBER: This meta-analysis was published for registration in PROSPERO prior to starting (CRD York, CRD42021254122).


Assuntos
Síndrome Coronariana Aguda , Serviços Médicos de Emergência , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/terapia , Eletrocardiografia/métodos , Serviços Médicos de Emergência/métodos , Humanos , Estudos Prospectivos , Medição de Risco/métodos
8.
Int J Cardiol Heart Vasc ; 41: 101063, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35663622

RESUMO

Background: Moderate aortic valve stenosis occurs twice as often as severe aortic stenosis (AS) and carries a similarly poor prognosis. Current European and American guidelines offer limited insight into moderate AS (MAS) patients with unexplained symptoms. Measuring valve physiology at rest while most patients experience symptoms during exertion might represent a conceptual limitation in the current grading of AS severity. The stress aortic valve index (SAVI) may delineate hemodynamically significant AS among patients with MAS. Objectives: To investigate the diagnostic value of SAVI in symptomatic MAS patients with normal left ventricular ejection fraction (LVEF ≥ 50%): aortic valve area (AVA) > 1 cm2 plus either mean valve gradient (MG) 15-39 mmHg or maximal aortic valve velocity (AOV max) 2.5-3.9 m/s. Short-term objectives include associations with symptom burden, functional capacity, and cardiac biomarkers. Long-term objectives include clinical outcomes. Methods and results: Multicenter, non-blinded, observational cohort. AS severity will be graded invasively (aortic valve pressure measurements with dobutamine stress testing for SAVI) and non-invasively (echocardiography during dobutamine and exercise stress). Computed tomography (CT) of the aortic valve will be scored for calcium, and hemodynamics simulated using computational fluid dynamics. Cardiac biomarkers and functional parameters will be serially monitored. The primary objective is to see how SAVI and conventional measures (MG, AVA and Vmax) correlate with clinical parameters (quality of life survey, 6-minute walk test [6MWT], and biomarkers). Conclusions: The SAVI-AoS study will extensively evaluate patients with unexplained, symptomatic MAS to determine any added value of SAVI versus traditional, resting valve parameters.

9.
J Clin Med ; 11(4)2022 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-35207350

RESUMO

The timely revascularization of an occluded coronary artery is the cornerstone of treatment in patients with ST-elevation myocardial infarction (STEMI). As essential as this treatment is, it can also cause additional damage to cardiomyocytes that were still viable before reperfusion, increasing infarct size. This has been termed "myocardial reperfusion injury". To date, there is still no effective treatment for myocardial reperfusion injury in patients with STEMI. While numerous attempts have been made to overcome this hurdle with various experimental therapies, the common denominator of these therapies is that, although they often work in the preclinical setting, they fail to demonstrate the same results in human trials. Hypothermia is an example of such a therapy. Although promising results were derived from experimental studies, multiple randomized controlled trials failed to do the same. This review includes a discussion of hypothermia as a potential treatment for myocardial reperfusion injury, including lessons learned from previous (negative) trials, advanced techniques and materials in current hypothermic treatment, and the possible future of hypothermia for cardioprotection in patients with STEMI.

10.
Ther Hypothermia Temp Manag ; 12(2): 129-137, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34847796

RESUMO

In acute myocardial infarction (AMI), myocardial reperfusion injury may undo part of the recovery after revascularization of the occluded coronary artery. Selective intracoronary hypothermia is a novel method aimed at reducing myocardial reperfusion injury, but its presumed protective effects in AMI still await further elucidation. This proof-of-concept study assesses the potential protective effects of selective intracoronary hypothermia in an ex-vivo, isolated beating heart model of AMI. In four isolated Langendorff perfused beating pig hearts, an anterior wall myocardial infarction was created by inflating a balloon in the mid segment of the left anterior descending (LAD) artery. After one hour, two hearts were treated with selective intracoronary hypothermia followed by normal reperfusion (cooled hearts). In the other two hearts, the balloon was deflated after one hour, allowing normal reperfusion (control hearts). Biopsies for histologic and electron microscopic evaluation were taken from the myocardium at risk at different time points: before occlusion (t = BO); 5 minutes before reperfusion (t = BR); and 10 minutes after reperfusion (t = AR). Electron microscopic analysis was performed to evaluate the condition of the mitochondria. Histological analyses included evaluation of sarcomeric collapse and intramyocardial hematoma. Electron microscopic analysis revealed intact mitochondria in the hypothermia treated hearts compared to the control hearts where mitochondria were more frequently damaged. No differences in the prespecified histological parameters were observed between cooled and control hearts at t = AR. In the isolated beating porcine heart model of AMI, reperfusion was associated with additional myocardial injury beyond ischemic injury. Selective intracoronary hypothermia preserved mitochondrial integrity compared to nontreated controls.


Assuntos
Hipotermia Induzida , Hipotermia , Infarto do Miocárdio , Traumatismo por Reperfusão Miocárdica , Animais , Hipotermia/terapia , Hipotermia Induzida/métodos , Infarto do Miocárdio/patologia , Infarto do Miocárdio/terapia , Traumatismo por Reperfusão Miocárdica/patologia , Traumatismo por Reperfusão Miocárdica/terapia , Miocárdio/patologia , Suínos
11.
Bioengineering (Basel) ; 8(2)2021 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-33572063

RESUMO

Current prognostic risk scores in cardiac surgery do not benefit yet from machine learning (ML). This research aims to create a machine learning model to predict one-year mortality of a patient after transcatheter aortic valve implantation (TAVI). We adopt a modern gradient boosting on decision trees classifier (GBDTs), specifically designed for categorical features. In combination with a recent technique for model interpretations, we developed a feature analysis and selection stage, enabling the identification of the most important features for the prediction. We base our prediction model on the most relevant features, after interpreting and discussing the feature analysis results with clinical experts. We validated our model on 270 consecutive TAVI cases, reaching a C-statistic of 0.83 with CI [0.82, 0.84]. The model has achieved a positive predictive value ranging from 57% to 64%, suggesting that the patient selection made by the heart team of professionals can be further improved by taking into consideration the clinical data we identified as important and by exploiting ML approaches in the development of clinical risk scores. Our approach has shown promising predictive potential also with respect to widespread prognostic risk scores, such as logistic European system for cardiac operative risk evaluation (EuroSCORE II) and the society of thoracic surgeons (STS) risk score, which are broadly adopted by cardiologists worldwide.

12.
Circ Cardiovasc Interv ; 14(8): e010326, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34266310

RESUMO

Myocardial reperfusion injury-triggered by an inevitable inflammatory response after reperfusion-may undo a considerable part of the myocardial salvage achieved through timely percutaneous coronary intervention in patients with acute myocardial infarction. Because infarct size is strongly correlated to mortality and risk of heart failure, the importance of endeavors for cardioprotective therapies to attenuate myocardial reperfusion injury and decrease infarct size remains undisputed. Myocardial reperfusion injury is the result of several complex nonlinear phenomena, and for a therapy to be effective, it should act on multiple targets involved in this injury. In this regard, hypothermia remains a promising treatment despite a number of negative randomized controlled trials in humans with acute myocardial infarction so far. To turn the tide for hypothermia in patients with acute myocardial infarction, sophisticated solutions for important limitations of systemic hypothermia should continue to be developed. In this review, we provide a comprehensive overview of the pathophysiology and clinical expression of myocardial reperfusion injury and discuss the current status and possible future of hypothermia for cardioprotection in patients with acute myocardial infarction.


Assuntos
Hipotermia Induzida , Hipotermia , Infarto do Miocárdio , Traumatismo por Reperfusão Miocárdica , Intervenção Coronária Percutânea , Humanos , Hipotermia Induzida/efeitos adversos , Infarto do Miocárdio/terapia , Reperfusão Miocárdica/efeitos adversos , Traumatismo por Reperfusão Miocárdica/etiologia , Traumatismo por Reperfusão Miocárdica/prevenção & controle , Intervenção Coronária Percutânea/efeitos adversos
13.
J Cardiovasc Dev Dis ; 8(6)2021 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-34199892

RESUMO

Current prognostic risk scores for transcatheter aortic valve implantation (TAVI) do not benefit yet from modern machine learning techniques, which can improve risk stratification of one-year mortality of patients before TAVI. Despite the advancement of machine learning in healthcare, data sharing regulations are very strict and typically prevent exchanging patient data, without the involvement of ethical committees. A very robust validation approach, including 1300 and 631 patients per center, was performed to validate a machine learning model of one center at the other external center with their data, in a mutual fashion. This was achieved without any data exchange but solely by exchanging the models and the data processing pipelines. A dedicated exchange protocol was designed to evaluate and quantify the model's robustness on the data of the external center. Models developed with the larger dataset offered similar or higher prediction accuracy on the external validation. Logistic regression, random forest and CatBoost lead to areas under curve of the ROC of 0.65, 0.67 and 0.65 for the internal validation and of 0.62, 0.66, 0.68 for the external validation, respectively. We propose a scalable exchange protocol which can be further extended on other TAVI centers, but more generally to any other clinical scenario, that could benefit from this validation approach.

14.
Med Eng Phys ; 90: 66-81, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33781481

RESUMO

Current aortic stenosis severity grading is based mainly on the local properties of the stenotic valve, such as pressure gradient or jet velocity. Success rates of valve replacement therapy are still suboptimal, so alternative grading of AS should be investigated. We suggest the efficiency of power transfer from the left ventricle to the aorta, as it takes into account heart, valve and circulatory system. Left ventricular and circulatory power were estimated using a 0D model, which was optimised to patient data: left ventricular and aortic pressure, aortic flow and diastolic left ventricular volume. Optimisation was performed using a data assimilation method. These data were available in rest as well as chemically induced exercise for twelve patients. Using this limited data set, we showed that aortic valve efficiency is highly heterogeneous between patients, but also often dependent on the haemodynamic load. This indicates that power transfer efficiency is a highly interesting metric for further research in aortic stenosis.


Assuntos
Estenose da Valva Aórtica , Aorta , Valva Aórtica , Ventrículos do Coração , Hemodinâmica , Humanos , Função Ventricular Esquerda
15.
Front Cardiovasc Med ; 8: 787246, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34869698

RESUMO

Background: Machine learning models have been developed for numerous medical prognostic purposes. These models are commonly developed using data from single centers or regional registries. Including data from multiple centers improves robustness and accuracy of prognostic models. However, data sharing between multiple centers is complex, mainly because of regulations and patient privacy issues. Objective: We aim to overcome data sharing impediments by using distributed ML and local learning followed by model integration. We applied these techniques to develop 1-year TAVI mortality estimation models with data from two centers without sharing any data. Methods: A distributed ML technique and local learning followed by model integration was used to develop models to predict 1-year mortality after TAVI. We included two populations with 1,160 (Center A) and 631 (Center B) patients. Five traditional ML algorithms were implemented. The results were compared to models created individually on each center. Results: The combined learning techniques outperformed the mono-center models. For center A, the combined local XGBoost achieved an AUC of 0.67 (compared to a mono-center AUC of 0.65) and, for center B, a distributed neural network achieved an AUC of 0.68 (compared to a mono-center AUC of 0.64). Conclusion: This study shows that distributed ML and combined local models techniques, can overcome data sharing limitations and result in more accurate models for TAVI mortality estimation. We have shown improved prognostic accuracy for both centers and can also be used as an alternative to overcome the problem of limited amounts of data when creating prognostic models.

16.
EuroIntervention ; 17(4): e309-e316, 2021 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-33016881

RESUMO

BACKGROUND: Absolute hyperaemic coronary blood flow (Q, in mL/min) and resistance (R, in Wood units [WU]) can be measured invasively by continuous thermodilution. AIMS: The aim of this study was to assess normal reference values of Q and R. METHODS: In 177 arteries (69 patients: 25 controls, i.e., without identifiable coronary atherosclerosis; 44 patients with mild, non-obstructive atherosclerosis), thermodilution-derived hyperaemic Q and total, epicardial, and microvascular absolute resistances (Rtot, Repi, and Rmicro) were measured. In 20 controls and 29 patients, measurements were obtained in all three major coronary arteries, thus allowing calculations of Q and R for the whole heart. In 15 controls (41 vessels) and 25 patients (71 vessels), vessel-specific myocardial mass was derived from coronary computed tomography angiography. RESULTS: Whole heart hyperaemic Q tended to be higher in controls compared to patients (668±185 vs 582±138 mL/min, p=0.068). In the left anterior descending coronary artery (LAD), hyperaemic Q was significantly higher (293±102 mL/min versus 228±71 mL/min, p=0.004) in controls than in patients. This was driven mainly by a difference in Repi (43±23 vs 83±41 WU, p=0.048), without significant differences in Rmicro. After adjustment for vessel-specific myocardial mass, hyperaemic Q was similar in the three vascular territories (5.9±1.9, 4.9±1.7, and 5.3±2.1 mL/min/g, p=0.44, in the LAD, left circumflex and right coronary artery, respectively). CONCLUSIONS: The present report provides reference values of absolute coronary hyperaemic Q and R. Q was homogeneously distributed in the three major myocardial territories but the large ranges of observed hyperaemic values of flow and of microvascular resistance preclude their clinical use for inter-patient comparison.


Assuntos
Vasos Coronários , Termodiluição , Angiografia Coronária , Circulação Coronária , Vasos Coronários/diagnóstico por imagem , Humanos , Microcirculação , Valores de Referência , Resistência Vascular
17.
Int J Cardiol Heart Vasc ; 28: 100536, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32478166

RESUMO

BACKGROUND: Little is known about survival and quality of life (QoL) of patients treated by transcatheter aortic valve implantation (TAVI) compared to the age- and sex-matched general population. In this study we compared subgroups of the National Heart Registration TAVI cohort to the Dutch age- and sex-matched population at the level of survival and QoL. METHODS AND RESULTS: From the Netherlands Heart Registration (NHR) the TAVI cohort (5489 patients, period 2013-2017) was extracted. These data were compared to the national Dutch population data collected from the national statistics office, Statistics Netherlands (CBS). Subgroups were defined according to sex and age (<65, 65-80 and >80). For QoL analyses the age subgroups <65, 65-75 and >75 were used. Long term survival was significantly higher in the general population compared to the TAVI population. Elderly TAVI patients (>80 years) had the same survival as the age-matched general population (46vs43% at 5 years, respectively). Survival in women was better than in men in both the general population and the TAVI cohort. Patients treated by TAVI, aged 65 years and older had a comparable QoL to that of the general population. CONCLUSIONS: This study shows that TAVI patients aged 80 years and older have a similar long-term survival as an age-matched general population. However, because of lower survival in under 80 TAVI patients, the overall long term survival of all TAVI patients is worse than that of the general population in the Netherlands. This study also suggests that QoL after TAVI treatment is comparable to QoL in the general population.

18.
NPJ Digit Med ; 3: 92, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32665977

RESUMO

Wrist-worn devices with heart rate monitoring have become increasingly popular. Although current guidelines advise to consider clinical symptoms and exercise tolerance during decision-making in heart disease, it remains unknown to which extent wearables can help to determine such functional capacity measures. In clinical settings, the 6-minute walk test has become a standardized diagnostic and prognostic marker. We aimed to explore, whether 6-minute walk distances can be predicted by wrist-worn devices in patients with different stages of mitral and aortic valve disease. A total of n = 107 sensor datasets with 1,019,748 min of recordings were analysed. Based on heart rate recordings and literature information, activity levels were determined and compared to results from a 6-minute walk test. The percentage of time spent in moderate activity was a predictor for the achievement of gender, age and body mass index-specific 6-minute walk distances (p < 0.001; R 2 = 0.48). The uncertainty of these predictions is demonstrated.

19.
Heart ; 106(19): 1489-1494, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32471907

RESUMO

OBJECTIVE: The prognostic importance of a coronary stenosis depends on its functional severity and its depending myocardial mass. Functional severity can be assessed by fractional flow reserve (FFR), estimated non-invasively by a specific validated CT algorithm (FFRCT). Calculation of myocardial mass at risk by that same set of CT data (CTmass), however, has not been prospectively validated so far. The aim of the present study was to compare relative territorial-based CTmass assessment with relative flow distribution, which is closely linked to true myocardial mass. METHODS: In this exploratory study, 35 patients with (near) normal coronary arteries underwent CT scanning for computed flow-based CTmass assessment and underwent invasive myocardial perfusion measurement in all 3 major coronary arteries by continuous thermodilution. Next, the mass and flows were calculated as relative percentages of total mass and perfusion. RESULTS: The mean difference between CTmass per territory and invasively measured myocardial perfusion, both expressed as percentage of total mass and perfusion, was 5.3±6.2% for the left anterior descending territory, -2.0±7.4% for the left circumflex territory and -3.2±3.4% for the right coronary artery territory. The intraclass correlation between the two techniques was 0.90. CONCLUSIONS: Our study shows a close relationship between the relative mass of the perfusion territory calculated by the specific CT algorithm and invasively measured myocardial perfusion. As such, these data support the use of CTmass to estimate territorial myocardium-at-risk in proximal coronary arteries.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Tomografia Computadorizada Multidetectores , Imagem de Perfusão do Miocárdio , Idoso , Algoritmos , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Termodiluição
20.
Int J Cardiol ; 313: 32-34, 2020 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-32380248

RESUMO

AIMS: Pressure loss versus transvalvular flow analysis challenges physiologic models of current aortic valve stenosis. New conceptual frameworks are needed to explain these real-world observations. METHODS AND RESULTS: A patient-specific, 3D-printed, silicon model of a stenotic valve was placed inside an in-vitro haemodynamic model of the circulatory system. Instantaneous pressure and flow in the aorta and left ventricle were simulated according to measured patient specific parameters. Thereafter, a realistic transcatheter aortic valve was implanted (TAVI) in the model. Simulated post-TAVI mean pressure gradients resembled patient observations (3.7 ± 0.7 mmHg vs 6.7 ± 2.3 mmHg), but pre-TAVI measurements underestimated the pressure gradient (35.1 ± 0.6 mmHg vs 45.3 ± 1.5 mmHg). CONCLUSION: Patient-specific 3D-printed stenotic aortic valve models could simulate baseline haemodynamics. A TAVI procedure was successfully performed on the 3D silicone rubber valve in a physiologic in-vitro model. Pre-TAVI haemodynamics in the model underestimated in-patient mean pressure gradient, whereas post TAVI pressure gradient was predicted correctly with the TAVI valve inside the 3D printed model. This study shows that these types of models could be used to study AS hemodynamics with the TAVI valve inside the 3D printed model. Improvements in the 3D-printed model, like addition of calcification and fine-tuning of the haemodynamic model, could further enhance accuracy of the simulation.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Hemodinâmica , Humanos , Impressão Tridimensional , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA