Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Environ Sci (China) ; 114: 391-400, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35459502

RESUMO

The incineration of sacrificial offerings is a significant widely practiced custom that is also a kind of neglected air pollution source in China. Our results showed that the emission factors of particulate matter, SO2, CO, NOx, and VOCs emitted from the incineration of sacrificial offerings with purification systems were reduced by 95%, 19%, 9%, 82%, and 42%, respectively, compared with those without a purification system, revealing a significant effect of the flue gas purification system on reducing particulate matter and gaseous pollutants. The emission level of air pollutants from the incineration of sacrificial offerings remained stable before 2013 and then showed a remarkable decrease after the implementation of China´s Air Pollution Prevention Action Plan in 2013. The emissions of TSP (total suspended particulate), PM10, PM2.5, and NOx in 2009 were 8222, 6106, 5656 and 15,878 ton, respectively, obviously higher than 3434, 2551, 2305 and 8579 ton in 2019. Such trend was affected by both the quantity of incineration and the installation rate of purification systems after the Emission Standard of Air Pollutants for Crematory (GB 13801-2015) issued in China. Distinct spatial distribution of atmospheric pollutants from incineration of sacrificial offerings was found with higher in the east and south of China than the west and north of China, which is proportional to the regional economy and population. The maximum ground-level concentration typically occurred at 0.12-0.2 km from the pollution source, posing potential health risks to people entering and exiting funeral and burial sites and nearby residents.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , Poluentes Ambientais , Poluentes Atmosféricos/análise , Poluição do Ar/prevenção & controle , China , Monitoramento Ambiental , Gases , Humanos , Incineração , Material Particulado/análise
2.
Am J Physiol Endocrinol Metab ; 317(4): E677-E685, 2019 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31408378

RESUMO

Cardiovascular function is impaired and preeclampsia risk elevated in women conceiving by in vitro fertilization (IVF) in the absence of a corpus luteum (CL). Here, we report the serial evaluation of hormones and other circulating factors in women who conceived with (or without) IVF. After a prepregnancy baseline, the study participants (n = 19-24/cohort) were evaluated six times during pregnancy and once postpartum (~1.6 yr). IVF pregnancies were stratified by protocol and CL number, i.e., ovarian stimulation (>1 CL) or hypothalamic-pituitary suppression (0 CL) versus spontaneous conceptions (1 CL). Results include the following: 1) relaxin was undetectable throughout pregnancy (including late gestation) in the 0 CL cohort, but markedly elevated in ~50% of women in the >1 CL cohort; 2) progesterone, plasma renin activity, and aldosterone transiently surged at 5-6 gestational weeks in the >1 CL group; 3) soluble vascular endothelial growth factor-1 (sFLT-1) abruptly increased between 5-6 and 7-9 gestational weeks in all three participant cohorts, producing a marked elevation in sFLT-1/PLGF (placental growth factor) ratio exceeding any other time point during pregnancy; 4) sFLT-1 was higher throughout most of gestation in both IVF cohorts with or without abnormal obstetrical outcomes; 5) during pregnancy, C-reactive protein (CRP) increased in 0 and 1 CL, but not >1 CL cohorts; and 6) plasma protein, but not hemoglobin, was lower in the >1 CL group throughout gestation. The findings highlight that, compared with spontaneously conceived pregnancy, the maternal milieu of IVF pregnancy is not physiologic, and the specific perturbations vary according to IVF protocol and CL status.


Assuntos
Corpo Lúteo/fisiologia , Hormônios Esteroides Gonadais/metabolismo , Sistema Imunitário/fisiologia , Neovascularização Fisiológica/fisiologia , Adulto , Proteína C-Reativa/análise , Estudos de Coortes , Corpo Lúteo/metabolismo , Feminino , Fertilização in vitro , Humanos , Sistema Hipotálamo-Hipofisário/efeitos dos fármacos , Recém-Nascido , Peptídeos e Proteínas de Sinalização Intercelular/sangue , Pessoa de Meia-Idade , Indução da Ovulação , Gravidez , Resultado da Gravidez
3.
SN Appl Sci ; 3(8): 754, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34337325

RESUMO

The promulgation and implementation of the national and Beijing municipal standards for air pollutants emitted from crematoriums has effectively alleviated the problem of "black smoke" in crematoriums, but noticeable odor in crematoriums remains. We determined the level of odor emissions in crematoriums by monitoring the odor concentrations of cremators, incinerators, and cremation workshops in five crematoriums in Beijing. Subsequently, we analyzed the major contributing factors to the odor level and proposed control measures. A high odor concentration in crematoriums was observed; two different mechanisms were proposed to explain this finding. First, poor ventilation conditions in workshops and inadequate airtightness of equipment resulted in dimensionless concentrations of unorganized odor emissions in the workshops ranging from 97 to 732, with an average of 504, which is much higher than the standard level of 20. Second, the postprocessing facilities used in cremation sites produce poor odor removal, which, coupled with fuel usage and unregulated operations, led to high concentrations of organized odor emissions ranging from 231 to 1303 (910 on average) for cremators and incinerators. The odor emissions of cremators and incinerators meet the Integrated Emission Standards of Air Pollutants (DB11-501-2017), which are suitable for industries containing industrial kilns but not for crematoriums. The odor emissions in crematoriums are lower than those emitted from industries, such as fiber manufacturing and activated carbon processing. However, the unique geographical locations of crematoriums, high population density, and high exposure risk to local residents necessitate strengthening the management and control of odor emissions from crematoriums. To further address the problem of odor emissions from crematoriums in Beijing, further clarification and tightening of industry standards for the concentration limits of organized and unorganized odor emissions is recommended. Crematoriums will thus be prompted to increase odor control in workshops and adopt and improve deodorization facilities, including the installation and application of treatment facilities, such as adsorption and biological control.

4.
Hypertension ; 74(3): 705-715, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31352818

RESUMO

Commonly used in vitro fertilization protocols produce pregnancies without a corpus luteum (CL), a major source of reproductive hormones. In vitro fertilization pregnancies without a CL showed deficient gestational increases of central (aortic) arterial compliance during the first trimester and were at increased risk for developing preeclampsia. Here, we investigated whether there was generalized impairment of cardiovascular adaptation in in vitro fertilization pregnancies without a CL compared with pregnancies conceived spontaneously or through ovarian stimulation, which lead to 1 and >1 CL, respectively (n=19-26 participants per cohort). Prototypical maternal cardiovascular adaptations of gestation were serially evaluated noninvasively, initially during the follicular phase before conception, 6× in pregnancy, and then, on average, 1.6 years post-partum. The expected increases of cardiac output, left atrial dimension, peak left ventricular filling velocity in early diastole (E wave velocity), peripheral/central arterial pulse pressure ratio, and global AC, as well as decrease in augmentation index were significantly attenuated or absent during the first trimester in women who conceived without a CL, when compared with the 1 and >1 CL cohorts, which were comparable. Thereafter, these cardiovascular measures showed recovery in the 0 CL group except for E wave velocity, which remained depressed. These results provided strong support for a critical role of CL factor(s) in the transformation of the maternal cardiovascular system in early gestation. Regimens that lead to the development of a CL or replacement of missing CL factor(s) may be indicated to improve cardiovascular function and reduce preeclampsia risk in in vitro fertilization pregnancies.


Assuntos
Doenças Cardiovasculares/etiologia , Sistema Cardiovascular/fisiopatologia , Corpo Lúteo/patologia , Fertilização in vitro/efeitos adversos , Saúde Materna , Adulto , Análise de Variância , Débito Cardíaco/fisiologia , Doenças Cardiovasculares/diagnóstico por imagem , Doenças Cardiovasculares/epidemiologia , Estudos de Coortes , Feminino , Testes de Função Cardíaca , Humanos , Modelos Lineares , Gravidez , Primeiro Trimestre da Gravidez , Estudos Prospectivos , Análise de Onda de Pulso
5.
PLoS One ; 13(5): e0194226, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29718907

RESUMO

The process of corpse cremation generates numerous harmful air pollutants, including particulate matter (PM), sulfur dioxide (SO2), nitrogen oxides (NOx), volatile organic compounds (VOCs), and heavy metals. These pollutants could have severe effects on the surrounding environment and human health. Currently, the awareness of the emission levels of harmful air pollutants from cremators and their emission characteristics is insufficient. In this study, we obtained the emission characteristics of flue gas from cremators in Beijing and determined the localized emission factors and emission levels of harmful air pollutants based on actual monitoring data from nine typical cremators. The results show that the emissions of air pollutants from the cremators that directly discharge flue gas exceed the emission standards of China and Beijing. The installation of a flue gas post-treatment system could effectively reduce gaseous pollutants and the emission levels of PM. After being equipped with a flue gas post-treatment system, the emission concentrations of PM10, PM2.5, CO, SO2 and VOCs from the cremators are reduced by 97.6, 99.2, 19.6, 85.2 and 70.7%, respectively. Moreover, the emission factors of TSP, PM10, PM2.5, CO, SO2 and VOCs are also reduced to 12.5, 9.3, 3.0, 164.1, 8.8 and 19.8 g/body. Although the emission concentration of VOCs from the cremators is not high, they are one of major sources of "odor" in the crematories and demand more attention. Benzene, a chemical that can seriously harm human health, constitutes the largest proportion (~50%) of the chemical components of VOCs in the flue gas from the cremators.


Assuntos
Poluentes Atmosféricos/análise , Cremação , Monitoramento Ambiental , Poluentes Atmosféricos/química , Pequim , Gases/análise , Gases/química , Controle de Qualidade , Compostos Orgânicos Voláteis/análise , Compostos Orgânicos Voláteis/química
6.
Physiol Rep ; 6(24): e13947, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30578623

RESUMO

Profound changes occur in the maternal circulation during pregnancy. Routine measures of arterial function - central systolic pressure (CSP) and augmentation index (AIx) - decline during normal human pregnancy. The objectives of this study were twofold: (1) explore wave reflection indices besides CSP and AIx that are not routinely reported, if at all, during normal human pregnancy; and (2) compare wave reflection indices and global arterial compliance (gAC) obtained from carotid artery pressure waveforms (CAPW) as a surrogate for aortic pressure waveforms (AOPW) versus AOPW synthesized from radial artery pressure waveforms (RAPW) using a generalized transfer function. To our knowledge, a comparison of these two methods has not been previously evaluated in the context of pregnancy. Ten healthy women with normal singleton pregnancies were studied using applanation tonometry (SphygmoCor) at pre-conception, and then during 10-12 and 33-35 gestational weeks. CSP and AIx declined, and gAC increased during pregnancy as previously reported. As a consequence of the rise in gAC, the return of reflected waves of lesser magnitude from peripheral reflection sites to the aorta was delayed that, in turn, reduced systolic duration of reflected waves, augmentation index, central systolic pressure, LV wasted energy due to reflected waves, and increased brachial-central pulse pressure. For several wave reflection indices, those derived from CAPW as a surrogate for AOPW versus RAPW using a generalized transfer function registered greater gestational increases of arterial compliance. This discordance may reflect imprecision of the generalized transfer function for some waveform parameters, though potential divergence of carotid artery and aortic pressure waveforms during pregnancy cannot be excluded.


Assuntos
Aorta/fisiologia , Pressão Sanguínea , Artérias Carótidas/fisiologia , Gravidez/fisiologia , Adulto , Complacência (Medida de Distensibilidade) , Feminino , Humanos , Pulso Arterial , Análise de Onda de Pulso
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA