Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Neurol ; 21(1): 259, 2021 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-34215217

RESUMO

BACKGROUND: The optic nerve sheath diameter (ONSD) and ONSD/eyeball transverse diameter (ETD) ratio have been proven to be correlated with intracranial pressure. This study aimed to evaluate the prognostic roles of ONSD and the ONSD/ETD ratio in comatose patients with supratentorial lesions and to determine the relationship of these two indices with the prognosis of such patients. METHODS: A total of 54 comatose patients with supratentorial lesions and 50 healthy controls were retrospectively included in this study. ONSD and ETD were measured by unenhanced computed tomography (CT). The differences in ONSD and the ONSD/ETD ratio between the two groups were compared. The prognosis of comatose patients was scored using the Glasgow Outcome Scale (GOS) at the 3-month follow-up, and these patients were classified into good (GOS score ≥ 3) and poor (GOS score < 3) prognosis groups. The differences in ONSD and the ONSD/ETD ratio were compared between comatose patients with good prognoses and those with poor prognoses. RESULTS: The ONSD and ONSD/ETD ratios in the comatose patients were 6.30 ± 0.60 mm and 0.27 ± 0.03, respectively, and both were significantly greater than those in the healthy controls (5.10 ± 0.47 mm, t = 11.426, P < 0.0001; 0.22 ± 0.02, t = 11.468, P < 0.0001; respectively). ONSD in patients with poor prognosis was significantly greater than that in patients with good prognosis (6.40 ± 0.56 vs. 6.03 ± 0.61 mm, t = 2.197, P = 0.032). The ONSD/ETD ratio in patients with poor prognosis was significantly greater than that in patients with good prognosis (0.28 ± 0.02 vs. 0.26 ± 0.03, t = 2.622, P = 0.011). The area under the receiver operating characteristic (ROC) curve, used to predict the prognosis of comatose patients, was 0.650 (95% confidence interval (CI): 0.486-0.815, P = 0.078) for ONSD and 0.711 (95% CI: 0.548-0.874, P = 0.014) for the ONSD/ETD ratio. CONCLUSIONS: The ONSD and ONSD/ETD ratios were elevated in comatose patients. The ONSD/ETD ratio might be more valuable than ONSD in predicting the prognoses of comatose patients with supratentorial lesions.


Assuntos
Coma , Nervo Óptico , Neoplasias Supratentoriais , Coma/diagnóstico , Coma/patologia , Escala de Resultado de Glasgow , Humanos , Nervo Óptico/diagnóstico por imagem , Nervo Óptico/patologia , Prognóstico , Estudos Retrospectivos , Neoplasias Supratentoriais/diagnóstico , Neoplasias Supratentoriais/patologia
2.
World J Clin Cases ; 10(33): 12175-12183, 2022 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-36483822

RESUMO

BACKGROUND: Optic nerve sheath diameter (ONSD) measurement is one of the non-invasive methods recommended for increased intracranial pressure (ICP) monitoring. AIM: This study aimed to evaluate the roles of optic nerve sheath diameter (ONSD) and ONSD/eyeball transverse diameter (ETD) ratio in predicting prognosis of death in comatose patients with acute stroke during their hospitalization. METHODS: A total of 67 comatose patients with acute stroke were retrospectively recruited. The ONSD and ETD were measured by cranial computed tomography (CT) scan. All patients underwent cranial CT scan within 24 h after coma onset. Patients were divided into death group and survival group according to their survival status at discharge. The differences of the ONSD and ONSD/ETD ratio between the two groups and their prognostic values were compared. RESULTS: The ONSD and ONSD/ETD ratio were 6.07 ± 0.72 mm and 0.27 ± 0.03 in the comatose patients, respectively. The ONSD was significantly greater in the death group than that in the survival group (6.32 ± 0.67 mm vs 5.65 ± 0.62 mm, t = 4.078, P < 0.0001). The ONSD/ETD ratio was significantly higher in the death group than that in the survival group (0.28 ± 0.03 vs 0.25 ± 0.02, t = 4.625, P < 0.0001). The area under the receiver operating characteristic curve was 0.760 (95%CI: 0.637-0.882, P < 0.0001) for the ONSD and 0.808 (95%CI: 0.696-0.920, P < 0.0001) for the ONSD/ETD ratio. CONCLUSION: The mortality increased in comatose patients with acute stroke when the ONSD was > 5.7 mm or the ONSD/ETD ratio was > 0.25. Both indexes could be used as prognostic tools for comatose patients with acute stroke. The ONSD/ETD ratio was more stable than the ONSD alone, which would be preferred in clinical practice.

3.
Sci Rep ; 12(1): 7136, 2022 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-35505074

RESUMO

The study aimed to evaluate the effectiveness of blood pool and myocardial models made by stereolithography in the diagnosis of different types of congenital heart disease (CHD). Two modeling methods were applied in the diagnosis of 8 cases, and two control groups consisting of experts and students diagnosed the cases using echocardiography with computed tomography, blood pool models, and myocardial models. The importance, suitability, and simulation degree of different models were analyzed. The average diagnostic rate before and after 3D printing was used was 88.75% and 95.9% (P = 0.001) in the expert group and 60% and 91.6% (P = 0.000) in the student group, respectively. 3D printing was considered to be more important for the diagnosis of complex CHDs (very important; average, 87.8%) than simple CHDs (very important; average, 30.8%) (P = 0.000). Myocardial models were considered most realistic regarding the structure of the heart (average, 92.5%). In cases of congenital corrected transposition of great arteries, Williams syndrome, coronary artery fistula, tetralogy of Fallot, patent ductus arteriosus, and coarctation of the aorta, blood pool models were considered more effective (average, 92.1%), while in cases of double outlet right ventricle and ventricular septal defect, myocardial models were considered optimal (average, 80%).


Assuntos
Coartação Aórtica , Cardiopatias Congênitas , Comunicação Interventricular , Ecocardiografia , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Humanos , Impressão Tridimensional
4.
Med Biol Eng Comput ; 60(10): 3029-3040, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36053430

RESUMO

Accurate diagnosis and surgical selection of the double-outlet right ventricle (DORV) is both critical and difficult. Virtual models and three-dimensional (3D) printing have been used to provide morphological copies to doctors as reference. However, the existing methods have shortcomings in visualization of the surgical results, optimal surgical design, and accurate surgical scheme measurements. To overcome this problem, we performed surgical predictions by designing the intraventricular baffle and ventricular septal defect patch to evaluate surgical options and using 3D printing to guide the trimming of the baffle or patch. A complete set of processes including scanning, modeling, designing, 3D printing, and guiding the trimming of the baffle for the diagnosis and surgical planning of DORV was established. Six cases were used to evaluate the feasibility of this method. The average rate of misdiagnosis of the six cases by computed tomography and echocardiography was 42.5%, which was reduced to 4.6% when the diagnosis was established using the virtual models and 3D printing as auxiliary tools. The approach effectively improved diagnostic accuracy, guided the operation, and simplified the process of patch trimming. The proposed method can thus be used for improving the surgical simulation and guiding of the DORV surgery.


Assuntos
Dupla Via de Saída do Ventrículo Direito , Comunicação Interventricular , Dupla Via de Saída do Ventrículo Direito/cirurgia , Ecocardiografia , Estudos de Viabilidade , Comunicação Interventricular/cirurgia , Humanos , Impressão Tridimensional
5.
Acta Radiol ; 51(4): 413-9, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20380604

RESUMO

BACKGROUND: Computed tomographic pulmonary angiography (CTPA) has been established as a first-line test in the acute pulmonary embolism (APE) diagnostic algorithm, but the assessment of the severity of APE by this method remains to be explored. PURPOSE: To retrospectively evaluate right ventricular (RV) dysfunction and severity in patients with APE without underlying cardiopulmonary disease using helical computed tomography (CT). MATERIAL AND METHODS: Seventy-three patients (35 men and 38 women) were divided into two groups according to the clinical findings: severe APE (n=22) and non-severe APE (n=51). Pulmonary artery CT obstruction index was calculated according to the location and degree of clots in the pulmonary arteries. Cardiovascular parameters including RV short axis and left ventricular (LV) short axis, RV short axis to LV short axis (RV/LV) ratio, main pulmonary artery, azygos vein, and superior vena cava diameters were measured. Leftward bowing of the interventricular septum, reflux of contrast medium into the inferior vena cava and azygos vein, and bronchial artery dilatation were also recorded. The results were analyzed by Mann-Whitney U test, chi(2) test, Spearman's rank correlation coefficient, and the area under the receiver operating characteristic curve (A(z)). RESULTS: CT obstruction index in patients with severe APE (median 43%) was higher than that of patients with non-severe APE (median 20%). Comparison of cardiovascular parameters between patients with severe and non-severe pulmonary embolism showed significant differences in RV short axis, LV short axis, RV/LV ratio, RV wall thickness, main pulmonary artery diameter, azygos vein diameter, leftward bowing of the interventricular septum, and bronchial artery dilatation. The correlation between CT obstruction indexes and cardiovascular parameters was significant. Spearman's rank correlation coefficient was highest between RV/LV ratio and CT obstruction index. A(z) values were significantly higher than 0.5 for CT obstruction index, LV short axis, RV/LV ratio, main pulmonary artery diameter, and azygos vein diameter. CONCLUSION: These results suggest that CTPA is a practical and accurate means for evaluating RV dysfunction of pulmonary embolism in patients without any underlying cardiopulmonary disease and can discriminate between severe and non-severe APE.


Assuntos
Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada Espiral/métodos , Disfunção Ventricular Direita/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Distribuição de Qui-Quadrado , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Iohexol , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Índice de Gravidade de Doença , Estatísticas não Paramétricas
6.
Neurosci Bull ; 35(4): 743-755, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30421271

RESUMO

The present study was aimed to evaluate resting-state functional connectivity and topological properties of brain networks in narcolepsy patients compared with healthy controls. Resting-state fMRI was performed in 26 adult narcolepsy patients and 30 matched healthy controls. MRI data were first analyzed by group independent component analysis, then a graph theoretical method was applied to evaluate the topological properties in the whole brain. Small-world network parameters and nodal topological properties were measured. Altered topological properties in brain areas between groups were selected as region-of-interest seeds, then the functional connectivity among these seeds was compared between groups. Partial correlation analysis was performed to evaluate the relationship between the severity of sleepiness and functional connectivity or topological properties in the narcolepsy patients. Twenty-one independent components out of 48 were obtained. Compared with healthy controls, the narcolepsy patients exhibited significantly decreased functional connectivity within the executive and salience networks, along with increased functional connectivity in the bilateral frontal lobes within the executive network. There were no differences in small-world network properties between patients and controls. The altered brain areas in nodal topological properties between groups were mainly in the inferior frontal cortex, basal ganglia, anterior cingulate, sensory cortex, supplementary motor cortex, and visual cortex. In the partial correlation analysis, nodal topological properties in the putamen, anterior cingulate, and sensory cortex as well as functional connectivity between these regions were correlated with the severity of sleepiness (sleep latency, REM sleep latency, and Epworth sleepiness score) among narcolepsy patients. Altered connectivity within the executive and salience networks was found in narcolepsy patients. Functional connection changes between the left frontal cortex and left caudate nucleus may be one of the parameters describing the severity of narcolepsy. Changes in the nodal topological properties in the left putamen and left posterior cingulate, changes in functional connectivity between the left supplementary motor area and right occipital as well as in functional connectivity between the left anterior cingulate gyrus and bilateral postcentral gyrus can be considered as a specific indicator for evaluating the severity of narcolepsy.


Assuntos
Encéfalo/fisiopatologia , Neuroimagem Funcional/métodos , Narcolepsia/fisiopatologia , Adulto , Mapeamento Encefálico , Feminino , Voluntários Saudáveis , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Adulto Jovem
7.
J Neurosurg ; 120(1): 197-206, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23870019

RESUMO

OBJECT: The aim of this study was to evaluate the clinical results and surgical outcomes of cystic vestibular schwannomas (VSs) with fluid-fluid levels. METHODS: Forty-five patients with cystic VSs and 86 with solid VSs were enrolled in the study. The patients in the cystic VSs were further divided into those with and without fluid-fluid levels. The clinical and neuroimaging features, intraoperative findings, and surgical outcomes of the 3 groups were retrospectively compared. RESULTS: Peritumoral adhesion was significantly greater in the fluid-level group (70.8%) than in the nonfluid-level group (28.6%) and the solid group (25.6%; p < 0.0001). Complete removal of the VS occurred significantly less in the fluid-level group (45.8%, 11/24) than in the nonfluid-level group (76.2%, 16/21) and the solid group (75.6%, 65/86; p = 0.015). Postoperative facial nerve function in the fluid-level group was less favorable than in the other 2 groups; good/satisfactory facial nerve function 1 year after surgery was noted in 50.0% cases in the fluid-level group compared with 83.3% cases in the nonfluid-level group (p = 0.038). CONCLUSIONS: Cystic VSs with fluid-fluid levels more frequently adhered to surrounding neurovascular structures and had a less favorable surgical outcome. A possible mechanism of peritumoral adhesion is intratumoral hemorrhage and consequent inflammatory reactions that lead to destruction of the tumor-nerve barrier. These findings may be useful in predicting surgical outcome and planning surgical strategy preoperatively.


Assuntos
Cistos do Sistema Nervoso Central/patologia , Neuroma Acústico/patologia , Adolescente , Adulto , Idoso , Cistos do Sistema Nervoso Central/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neuroma Acústico/cirurgia , Procedimentos Neurocirúrgicos/métodos , Complicações Pós-Operatórias , Período Pós-Operatório , Estudos Retrospectivos , Aderências Teciduais/patologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA