Ultrasonics ; 141: 107332, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38718460

RESUMO

BACKGROUND: Stroke is the second leading cause of death across the globe. Early screening and risk detection could provide early intervention and possibly prevent its incidence. Imaging modalities, including 1D-Transcranial Doppler Ultrasound (1D-TCD) or Transcranial Color-code sonography (TCCS), could only provide low spatial resolution or 2D image information, respectively. Notably, 3D imaging modalities including CT have high radiation exposure, whereas MRI is expensive and cannot be adopted in patients with implanted devices. This study proposes an alternative imaging solution for reconstructing 3D Doppler ultrasound geared towards providing a screening tool for the 3D vessel structure of the brain. METHODS: The system comprises an ultrasound phased array attached to a servo motor, which can rotate 180˚ at a speed of 2˚/s. We extracted the color Doppler ROI from the image before reconstructing it into a 3D view using a customized pixel-based algorithm. Different vascular diameters, flow velocity, and depth were tested using a vascular phantom with a pumped flow to confirm the system for imaging blood flow. These variables were set to mimic the vessel diameter, flow speed, and depth of the Circle of Willis (CoW) during a transcranial screening. RESULTS AND CONCLUSIONS: The lower values of absolute error and ratio were found in the larger vascular channels, and vessel diameter overrepresentation was observed. Under different flow velocities, such diameter overrepresentation in the reconstructed flow did not change much; however, it did change with different depths. Meanwhile, the setting of the velocity scale and the color gain affected the dimension of reconstructed objectives. Moreover, we presented a 3D image of CoW from a subject to demonstrate its potential. The findings of this work can provide a good reference for further studies on the reconstruction of the CoW or other blood vessels using Doppler imaging.


Assuntos
Círculo Arterial do Cérebro , Imageamento Tridimensional , Imagens de Fantasmas , Ultrassonografia Doppler Transcraniana , Círculo Arterial do Cérebro/diagnóstico por imagem , Imageamento Tridimensional/métodos , Ultrassonografia Doppler Transcraniana/métodos , Humanos , Algoritmos , Circulação Cerebrovascular , Velocidade do Fluxo Sanguíneo
2.
Brain Sci ; 14(7)2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-39061380

RESUMO

BACKGROUND: The recovery of locomotion is greatly prioritized, and neuromodulation has been emerging as a promising approach in recent times. STUDY DESIGN: Single-subject research design. SETTINGS: A laboratory at The Hong Kong Polytechnic University. OBJECTIVES: To investigate the effects of augmenting activity-based therapy (ABT) to transcutaneous electrical spinal cord stimulation (TSCS) on enhancing specific lower limb muscle strength and improving locomotor ability in an individual with chronic incomplete spinal cord injury (iSCI). METHODS: An individual with iSCI underwent two phases of treatment, ABT alone followed by combined ABT+TSCS, each for a period of 10 weeks. The TSCS stimulated T10-T11 and T12-L1 segments with a frequency of 30 Hz at an intensity between 105 mA and 130 mA. Manual muscle testing, 6 min walk test (6MWT), and surface electromyography (EMG) responses of specific lower limb muscles were measured. Additionally, spasticity and sensorimotor examinations were conducted every two weeks, while pain tolerance was recorded after each treatment session. RESULTS: After the ABT+TSCS treatment, there was an increase in overall muscle strength grading (from 1.8 ± 0.3 to 2.2 ± 0.6 out of 5.0). The 6MWT showed a greater increase in walking distance (3.5 m to 10 m) after combined treatment than ABT alone. In addition, the EMG response of the anterior rectus femoris, biceps femoris, medial gastrocnemius, and tibialis anterior after ABT+TSCS increased more than after ABT alone. The spasticity grade was reduced (from 0.8 ± 0.7 to 0.5 ± 0.6) whereas the average lower limb motor score increased from 17 to 23 points. No adverse effects were reported. CONCLUSIONS: ABT+TSCS increased the target-specific lower limb muscle strength and walking ability more than ABT alone in an individual with chronic iSCI.

3.
Front Bioeng Biotechnol ; 12: 1372158, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38576448

RESUMO

Background: Trans-spinal electrical stimulation (tsES) to the intact spinal cord poststroke may modulate the cortico-muscular control in stroke survivors with diverse lesions in the brain. This work aimed to investigate the immediate effects of tsES on the cortico-muscular descending patterns during voluntary upper extremity (UE) muscle contractions by analyzing cortico-muscular coherence (CMCoh) and electromyography (EMG) in people with chronic stroke. Methods: Twelve chronic stroke participants were recruited to perform wrist-hand extension and flexion tasks at submaximal levels of voluntary contraction for the corresponding agonist flexors and extensors. During the tasks, the tsES was delivered to the cervical spinal cord with rectangular biphasic pulses. Electroencephalography (EEG) data were collected from the sensorimotor cortex, and the EMG data were recorded from both distal and proximal UE muscles. The CMCoh, laterality index (LI) of the peak CMCoh, and EMG activation level parameters under both non-tsES and tsES conditions were compared to evaluate the immediate effects of tsES on the cortico-muscular descending pathway. Results: The CMCoh and LI of peak CMCoh in the agonist distal muscles showed significant increases (p < 0.05) during the wrist-hand extension and flexion tasks with the application of tsES. The EMG activation levels of the antagonist distal muscle during wrist-hand extension were significantly decreased (p < 0.05) with tsES. Additionally, the proximal UE muscles exhibited significant decreases (p < 0.05) in peak CMCoh and EMG activation levels by applying tsES. There was a significant increase (p < 0.05) in LI of peak CMCoh of proximal UE muscles during tsES. Conclusion: The cervical spinal cord neuromodulation via tsES enhanced the residual descending excitatory control, activated the local inhibitory circuits within the spinal cord, and reduced the cortical and proximal muscular compensatory effects. These results suggested the potential of tsES as a supplementary input for improving UE motor functions in stroke rehabilitation.

4.
J Clin Med ; 13(8)2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38673561

RESUMO

(1) Background: Swallowing is a complex process that comprises well-timed control of oropharyngeal and laryngeal structures to achieve airway protection and swallowing efficiency. To understand its temporality, previous research adopted adherence measures and revealed obligatory pairs in healthy swallows and the effect of aging and bolus type on the variability of event timing and order. This study aimed to (i) propose a systemic conceptualization of swallowing physiology, (ii) apply sequence analyses, a set of information-theoretic and bioinformatic methods, to quantify and characterize swallowing temporality, and (iii) investigate the effect of aging and dysphagia on the quantified variables using sequence analyses measures. (2) Method: Forty-three participants (17 young adults, 15 older adults, and 11 dysphagic adults) underwent B-mode ultrasound swallowing examinations at the mid-sagittal plane of the submental region. The onset, maximum, and offset states of hyoid bone displacement, geniohyoid muscle contraction, and tongue base retraction were identified and sorted to form sequences which were analyzed using an inventory of sequence analytic techniques; namely, overlap coefficients, Shannon entropy, and longest common subsequence algorithms. (3) Results: The concurrency of movement sequence was found to be significantly impacted by aging and dysphagia. Swallowing sequence variability was also found to be reduced with age and the presence of dysphagia (H(2) = 52.253, p < 0.001, η2 = 0.260). Four obligatory sequences were identified, and high adherence was also indicated in two previously reported pairs. These results provided preliminary support for the validity of sequence analyses for quantifying swallowing sequence temporality. (4) Conclusions: A systemic conceptualization of human deglutition permits a multi-level quantitative analysis of swallowing physiology. Sequence analyses are a set of promising quantitative measurement techniques for point-of-care ultrasound (POCUS) swallowing examinations and outcome measures for swallowing rehabilitation and evaluation of associated physiological conditions, such as sarcopenia. Findings in the current study revealed physiological differences among healthy young, healthy older, and dysphagic adults. They also helped lay the groundwork for future AI-assisted dysphagia assessment and outcome measures using POCUSs. Arguably, the proposed conceptualization and analyses are also modality-independent measures that can potentially be generalized for other instrumental swallowing assessment modalities.

5.
Ultrasound Med Biol ; 50(4): 564-570, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38272743

RESUMO

OBJECTIVE: We aimed to assess the reliability of quantifying psoas major (PM) and quadratus lumborum (QL) stiffness with ultrasound shear wave elastography (SWE), and to explore the effects of gender and physical activity on muscle stiffness. METHODS: Fifty-two healthy participants (18-32 y) were recruited. To determine reliability, 29 of them underwent repeated SWE measurements of PM and QL stiffness by an operator on the same day. The intra-class correlation coefficients (ICC3,1), standard error of measurement (SEM) and minimal detectable change with 95% confidence interval (MDC95) were calculated. The rest participants underwent a single measurement. Two-way MANCOVA was conducted for the effects of gender and physical activity on muscle stiffness. RESULTS: The observed reliability for PM (ICC3,1 = 0.89-0.92) and QL (ICC3,1 = 0.79-0.82) were good-to-excellent and good, respectively. The SEM (kPa) was 0.79-1.03 and 1.23-1.28, and the MDC95 (kPa) was 2.20-2.85 and 3.41-3.56 for PM and QL, respectively. After BMI adjustment, both gender (PM: F = 10.15, p = 0.003; QL: F = 18.07, p < 0.001) and activity level (PM: F = 5.90, p = 0.005; QL: F = 6.33, p = 0.004) influenced muscle stiffness. The female and inactive groups exhibited higher stiffness in both muscles. CONCLUSION: SWE is reliable for quantifying the stiffness of PM and QL. Female and physical inactivity may elevate PM and QL stiffness, underscoring the importance of accounting for these factors in muscle stiffness investigations. Larger prospective studies are needed to further elucidate their effects.


Assuntos
Músculos do Dorso , Técnicas de Imagem por Elasticidade , Humanos , Feminino , Reprodutibilidade dos Testes , Músculos Psoas/diagnóstico por imagem , Músculos Psoas/fisiologia , Exercício Físico
6.
IEEE Trans Med Imaging ; 43(7): 2679-2692, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38421850

RESUMO

In medical image analysis, anatomical landmarks usually contain strong prior knowledge of their structural information. In this paper, we propose to promote medical landmark localization by modeling the underlying landmark distribution via normalizing flows. Specifically, we introduce the flow-based landmark distribution prior as a learnable objective function into a regression-based landmark localization framework. Moreover, we employ an integral operation to make the mapping from heatmaps to coordinates differentiable to further enhance heatmap-based localization with the learned distribution prior. Our proposed Normalizing Flow-based Distribution Prior (NFDP) employs a straightforward backbone and non-problem-tailored architecture (i.e., ResNet18), which delivers high-fidelity outputs across three X-ray-based landmark localization datasets. Remarkably, the proposed NFDP can do the job with minimal additional computational burden as the normalizing flows module is detached from the framework on inferencing. As compared to existing techniques, our proposed NFDP provides a superior balance between prediction accuracy and inference speed, making it a highly efficient and effective approach. The source code of this paper is available at https://github.com/jacksonhzx95/NFDP.


Assuntos
Algoritmos , Pontos de Referência Anatômicos , Processamento de Imagem Assistida por Computador , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pontos de Referência Anatômicos/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
7.
Ultrasound Med Biol ; 50(3): 384-393, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38114347

RESUMO

OBJECTIVE: The aim of the work described here was to determine whether 3-D ultrasound can provide results comparable to those of conventional X-ray examination in assessing curve progression in patients with adolescent idiopathic scoliosis (AIS). METHODS: One hundred thirty-six participants with AIS (42 males and 94 females; age range: 10-18 y, mean age: 14.1 ± 1.9 y) with scoliosis of different severity (Cobb angle range: 10º- 85º, mean: of 24.3 ± 14.4º) were included. Each participant underwent biplanar low-dose X-ray EOS and 3-D ultrasound system scanning with the same posture on the same date. Participants underwent the second assessment at routine clinical follow-up. Manual measurements of scoliotic curvature on ultrasound coronal projection images and posterior-anterior radiographs were expressed as the ultrasound curve angle (UCA) and radiographic Cobb angle (RCA), respectively. RCA and UCA increments ≥5º represented a scoliosis progression detected by X-ray assessment and 3-D ultrasound assessment, respectively. RESULTS: The sensitivity and specificity of UCA measurement in detecting scoliosis progression were 0.93 and 0.90, respectively. The negative likelihood ratio of the diagnostic test for scoliosis progression by the 3-D ultrasound imaging system was 0.08. CONCLUSION: The 3-D ultrasound imaging method is a valid technique for detecting coronal curve progression as compared with conventional radiography in follow-up of AIS. Substituting conventional radiography with 3-D ultrasound is effective in reducing the radiation dose to which AIS patients are exposed during their follow-up examinations.


Assuntos
Cifose , Escoliose , Masculino , Feminino , Humanos , Adolescente , Criança , Escoliose/diagnóstico por imagem , Cifose/diagnóstico por imagem , Radiografia , Ultrassonografia , Raios X
8.
Diagnostics (Basel) ; 14(2)2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38248066

RESUMO

Transient elastography (TE), recommended by the WHO, is an established method for characterizing liver fibrosis via liver stiffness measurement (LSM). However, technical barriers remain towards point-of-care application, as conventional TE requires wired connections, possesses a bulky size, and lacks adequate imaging guidance for precise liver localization. In this work, we report the design, phantom validation, and clinical evaluation of a palm-sized TE system that enables simultaneous B-mode imaging and LSM. The performance of this system was validated experimentally using tissue-equivalent reference phantoms (1.45-75 kPa). Comparative studies against other liver elastography techniques, including conventional TE and two-dimensional shear wave elastography (2D-SWE), were performed to evaluate its reliability and validity in adults with various chronic liver diseases. Intra- and inter-operator reliability of LSM were established by an elastography expert and a novice. A good agreement was observed between the Young's modulus reported by the phantom manufacturer and this system (bias: 1.1-8.6%). Among 121 patients, liver stiffness measured by this system and conventional TE were highly correlated (r = 0.975) and strongly agreed with each other (mean difference: -0.77 kPa). Inter-correlation of this system with conventional TE and 2D-SWE was observed. Excellent-to-good operator reliability was demonstrated in 60 patients (ICCs: 0.824-0.913). We demonstrated the feasibility of employing a fully integrated phased array probe for reliable and valid LSM, guided by real-time B-mode imaging of liver anatomy. This system represents the first technical advancement toward point-of-care liver fibrosis assessment. Its small footprint, along with B-mode guidance capability, improves examination efficiency and scales up screening for liver fibrosis.

9.
Biosensors (Basel) ; 13(12)2023 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-38131758

RESUMO

Falls are a prevalent cause of injury among older people. While some wearable inertial measurement unit (IMU) sensor-based systems have been widely investigated for fall risk assessment, their reliability, validity, and identification ability in community-dwelling older people remain unclear. Therefore, this study evaluated the performance of a commercially available IMU sensor-based fall risk assessment system among 20 community-dwelling older recurrent fallers (with a history of ≥2 falls in the past 12 months) and 20 community-dwelling older non-fallers (no history of falls in the past 12 months), together with applying the clinical scale of the Mini-Balance Evaluation Systems Test (Mini-BESTest). The results show that the IMU sensor-based system exhibited a significant moderate to excellent test-retest reliability (ICC = 0.838, p < 0.001), an acceptable level of internal consistency reliability (Spearman's rho = 0.471, p = 0.002), an acceptable convergent validity (Cronbach's α = 0.712), and an area under the curve (AUC) value of 0.590 for the IMU sensor-based receiver-operating characteristic (ROC) curve. The findings suggest that while the evaluated IMU sensor-based system exhibited good reliability and acceptable validity, it might not be able to fully identify the recurrent fallers and non-fallers in a community-dwelling older population. Further system optimization is still needed.


Assuntos
Acidentes por Quedas , Equilíbrio Postural , Humanos , Idoso , Reprodutibilidade dos Testes , Medição de Risco/métodos , Curva ROC