Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Opt Express ; 29(13): 19292-19304, 2021 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-34266041

RESUMO

In the field of electrochemical energy storage systems, the use of in situ detection technology helps to study the mechanism of electrochemical reaction. Our group has previously in situ detected the electrochemical reaction in vanadium flow batteries by total internal reflection (TIR) imaging. In order to further improve the detection resolution, in this study, the weak measurement (WM) method was introduced to in situ detect the electrochemical reaction during the linear sweep voltammetry or the cyclic voltammetry tests with quantitative measurement of the absolute current density, which lays a foundation for replacing the TIR for two-dimensional imaging of electrochemical reactions in vanadium flow batteries, oxygen/hydrogen evolution reaction, surface treatments, electrochemical corrosion and so on.

2.
Anal Chem ; 91(18): 11576-11581, 2019 09 17.
Artigo em Inglês | MEDLINE | ID: mdl-31407571

RESUMO

In this paper, we propose a linear differential detection system based on a frequency domain weak measurement. The system can be used for detecting optical substances. Moreover, we completed an experiment to detect himan serum albumin (HSA) content in a mixture of human serum albumin and l-proline via dialysis. This work also proves the differential function of the system. This experiment can be further extended to detecting protein content in a mixed solution that contains protein macromolecules and various small molecules. It is very important for detecting molecules without photomarking in solutions of complex biological samples. In this paper, the system has an optical resolution of 1.39 × 10-5, and resolution of 4.06 × 10-8 mol/L for himan serum protein solution.


Assuntos
Óptica e Fotônica/métodos , Albumina Sérica Humana/análise , Glucose/química , Humanos , Rotação Ocular , Prolina/química , Teoria Quântica
3.
Appl Opt ; 58(31): 8583-8588, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31873343

RESUMO

The ability to identify L(+)-ascorbic acid from D(-)-isoascorbic acid in medicinal products is of practical interest. Based on the method of frequency domain weak measurement, a set of common optical path sensors for identification of L(+)-ascorbic acid and D(-)-isoascorbic acid is established. By quantificationally analyzing the magnitude and offset direction of the spectral central wavelength, a good identification of the concentration and the optically active forms of ascorbic acid has been achieved. The sensitivity and resolution of the sensor for optical rotation can reach 34.35 nm/° and ${5.53} \times {{10}^{ - 5}}^\circ $5.53×10-5 ∘, respectively. The detection resolution for L(+)-ascorbic acid is ${2.00} \times {{10}^{ - 4}}\;{\rm mol}/{\rm mL}$2.00×10-4mol/mL, and that for D(-)-isoascorbic acid is ${2.73} \times {{10}^{ - 4}}\;{\rm mol}/{\rm mL}$2.73×10-4mol/mL. The potential of the sensor in the detection of transparent but optically inactive impurities has been verified by comparative experiments of sodium chloride solution. The sensor also has been applied to identify medicinal vitamin C tablets, which verified the feasibility of the method in optically active pharmaceutical solutions with water-insoluble, optically inactive impurities. Since the sensor has the advantages of high precision, real-time, high robustness, and being non-destructive, it has a great prospect in the field of drug detection containing chiral molecules.

4.
Sensors (Basel) ; 19(11)2019 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-31151193

RESUMO

Self-reference detection is necessary and important to a biosensor. The linear weak measurement system based on total internal reflection has attracted widespread attention due to its high stability, label-free detection, and easy integration. In this paper, we propose a differential detection method based on the linear total internal reflection weak measurement system. We introduce the half-wave plate (HWP) to convert the H light and the V light to each other, thereby obtaining the difference in phase change of the optical path before and after the HWP. Experiments show that the system can not only achieve differential detection, but also has high stability. The linear differential weak measurement system proposed in this paper not only provides a new differential measurement method for real-time biosensors, but also enriches the types of weak measurement sensors.

5.
Sensors (Basel) ; 18(11)2018 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-30400305

RESUMO

A phase-sensitive fluidic biosensor based on a spectral-domain low-coherence interferometer is presented in this paper. With a fiber optic probe employing the common-path interferometric configuration, subnanometric changes in thickness of the molecular layers can be detected through phase analysis of the acquired interference signal from the sensor surface. Advantages of this biosensor include its picometer-scale thickness sensitivity, 13.9-ms time response, and tolerance to the fluctuation in concentration of the target solution. The capabilities of this biosensor in monitoring specific molecular binding and recognizing specific molecular was successfully demonstrated by using the reactions between the molecules of protein A and IgG. The calculated minimum detectable concentration of IgG is 0.11 µg/mL.

6.
Sensors (Basel) ; 18(11)2018 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-30404143

RESUMO

We propose a self-referential fast detection scheme for a frequency domain weak measurement system for the detection of enantiomeric impurities in chiral molecules. In a transmissive weak measurement system, the optical rotation (OR) is used to modify the pre-selected polarization state and the post-selection polarization state. We obtained the sum and difference of the optical rotations produced by the sample and the standard by rotating the quarter wave plate in the system. Then, we estimate the ratio of chiral molecules to enantiomeric impurities using the ratio of the central wavelength shifts caused by the addition and subtraction states described above. In this paper, our system has an optical resolution of 1.88 × 10-5°. At the same time, we completed the detection of the ratio of the two substances in the mixture of L-proline and D-proline in different proportions, which proved that our system can quickly detect the content of enantiomeric impurities in chiral molecules.

7.
Light Sci Appl ; 12(1): 172, 2023 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-37433801

RESUMO

Structured illumination microscopy (SIM) has become the standard for next-generation wide-field microscopy, offering ultrahigh imaging speed, superresolution, a large field-of-view, and long-term imaging. Over the past decade, SIM hardware and software have flourished, leading to successful applications in various biological questions. However, unlocking the full potential of SIM system hardware requires the development of advanced reconstruction algorithms. Here, we introduce the basic theory of two SIM algorithms, namely, optical sectioning SIM (OS-SIM) and superresolution SIM (SR-SIM), and summarize their implementation modalities. We then provide a brief overview of existing OS-SIM processing algorithms and review the development of SR-SIM reconstruction algorithms, focusing primarily on 2D-SIM, 3D-SIM, and blind-SIM. To showcase the state-of-the-art development of SIM systems and assist users in selecting a commercial SIM system for a specific application, we compare the features of representative off-the-shelf SIM systems. Finally, we provide perspectives on the potential future developments of SIM.

8.
Chem Commun (Camb) ; 59(87): 13038-13041, 2023 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-37843422

RESUMO

Mitochondrial probe SiRPFA was synthesized by attaching a long perfluoroalkyl chain on Si-rhodamine cationic dye. High lipophilicity endowed SiRPFA with mitochondrial membrane potential independent properties. Under stimulated emission depletion microscopy, SiRPFA clearly revealed changes in mitochondrial cristae morphology during autophagy induced by starvation or apoptosis.


Assuntos
Mitocôndrias , Membranas Mitocondriais , Rodaminas/metabolismo , Membranas Mitocondriais/metabolismo , Mitocôndrias/metabolismo , Microscopia de Fluorescência/métodos , Potencial da Membrana Mitocondrial
9.
Transl Vis Sci Technol ; 10(14): 25, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34935910

RESUMO

Purpose: This study investigates the repairing process of rat cornea after surgery of lamellar keratoplasty (LKP) and evaluates the effects of gelatin methacrylate (GelMA) hydrogel. Methods: In the LKP group, the lamellar stroma matrixes of Sprague-Dawley rats were transplanted to enhanced green fluorescent protein rats, whereas those in the GelMA group were also embedded with a GelMA hydrogel during the corneal transplantation. Grafted eyes were harvested on days seven, 30, and 90. Hematoxylin and eosin staining, immunofluorescence staining, scanning electron microscopy, optical coherence tomography, and a slit-lamp microscope were used to study the process of corneal restoration and regeneration. Results: A total of 42 rats were analyzed, including 18 rats in each of the experimental group and six rats in the control group. After three months, the infiltration degree of inflammatory cells differed between the LKP group and the GelMA group (P < 0.001). Moreover, in multiple comparisons in corneal thickness, significant difference was observed between the LKP group and the GelMA group. There was also divergence in the results between the LKP group and the control group (P < 0.001, P < 0.001). At the same time, the expression of α-smooth muscle actin (α-SMA) and transforming growth factor (TGF)-ß1 varied distinctly between the LKP group and the GelMA group (P < 0.05, P < 0.001). Conclusions: Significant differences were demonstrated between the LKP group and the GelMA group in inflammatory cell infiltration, corneal thickness, as well as the expression of α-SMA and TGF-ß1. Those differences indicate the ability of GelMA hydrogel to support alleviation in corneal stroma fibrosis and show the influences of fibrosis in the dysfunction of corneal refractive power. Translational Relevance: Our research provides new ideas for the future development of LKP and tissue-engineered corneas.


Assuntos
Gelatina , Hidrogéis , Animais , Córnea , Metacrilatos , Ratos , Ratos Sprague-Dawley , Regeneração
10.
Biomed Opt Express ; 12(8): 5128-5138, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-34513246

RESUMO

Diabetes is an important public health problem and finding quick testing methods with high accuracy, reliability, and convenience are important to control the blood glucose of diabetic patients. In this study, a sensor based on a weak measurement scheme was developed for the specific detection of glucose for the first time. The detection of glucose using the proposed method was completed by the high sensitivity and resolution of the weak measurement based on optical rotation detection, as well as the change in the optical rotation before and after the specific oxidation of glucose. The resolution of the as-obtained glucose sensor was around 2.71×10-3 g/L (1.50×10-2 mmol/L), and the detection range was 0-11 g/L (0-61 mmol/L).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA