Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 91
Filtrar
1.
Sensors (Basel) ; 24(8)2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38676166

RESUMO

Shoe-based wearable sensor systems are a growing research area in health monitoring, disease diagnosis, rehabilitation, and sports training. These systems-equipped with one or more sensors, either of the same or different types-capture information related to foot movement or pressure maps beneath the foot. This captured information offers an overview of the subject's overall movement, known as the human gait. Beyond sensing, these systems also provide a platform for hosting ambient energy harvesters. They hold the potential to harvest energy from foot movements and operate related low-power devices sustainably. This article proposes two types of strategies (Strategy 1 and Strategy 2) for an energy-autonomous shoe-based system. Strategy 1 uses an accelerometer as a sensor for gait acquisition, which reflects the classical choice. Strategy 2 uses a piezoelectric element for the same, which opens up a new perspective in its implementation. In both strategies, the piezoelectric elements are used to harvest energy from foot activities and operate the system. The article presents a fair comparison between both strategies in terms of power consumption, accuracy, and the extent to which piezoelectric energy harvesters can contribute to overall power management. Moreover, Strategy 2, which uses piezoelectric elements for simultaneous sensing and energy harvesting, is a power-optimized method for an energy-autonomous shoe system.

2.
J Biomech Eng ; 145(1)2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-35864775

RESUMO

The Ross procedure using the inclusion technique with anticommissural plication (ACP) is associated with excellent valve hemodynamics and favorable leaflet kinematics. The objective was to evaluate individual pulmonary cusp's biomechanics and fluttering by including coronary flow in the Ross procedure using an ex vivo three-dimensional-printed heart simulator. Ten porcine and five human pulmonary autografts were harvested from a meat abattoir and heart transplant patients. Five porcine autografts without reinforcement served as controls. The other autografts were prepared using the inclusion technique with and without ACP (ACP and NACP). Hemodynamic and high-speed videography data were measured using the ex vivo heart simulator. Although porcine autografts showed similar leaflet rapid opening and closing mean velocities, human ACP compared to NACP autografts demonstrated lower leaflet rapid opening mean velocity in the right (p = 0.02) and left coronary cusps (p = 0.003). The porcine and human autograft leaflet rapid opening and closing mean velocities were similar in all three cusps. Porcine autografts showed similar leaflet flutter frequencies in the left (p = 0.3) and noncoronary cusps (p = 0.4), but porcine NACP autografts versus controls demonstrated higher leaflet flutter frequency in the right coronary cusp (p = 0.05). The human NACP versus ACP autografts showed higher flutter frequency in the noncoronary cusp (p = 0.02). The leaflet flutter amplitudes were similar in all three cusps in both porcine and human autografts. The ACP compared to NACP autografts in the Ross procedure was associated with more favorable leaflet kinematics. These results may translate to the improved long-term durability of the pulmonary autografts.


Assuntos
Próteses Valvulares Cardíacas , Valva Pulmonar , Animais , Valva Aórtica/cirurgia , Autoenxertos , Fenômenos Biomecânicos , Hemodinâmica , Humanos , Valva Pulmonar/transplante , Suínos , Transplante Autólogo
3.
J Mol Cell Cardiol ; 164: 51-57, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34813842

RESUMO

Ischemic heart disease is a major cause of global morbidity and mortality, affecting over 15 million patients in the United States. Recent advances in research and innovation have greatly broadened clinicians' ability to treatment ischemic heart disease and associated heart failure using various preventive, pharmacologic, and surgical strategies. Specifically, innovative photosynthetic symbiotic systems using Synechococcus elongatus has gained significant attention. S. elongatus is a unicellular cyanobacterium that can carry out oxygenic photosynthesis. Photosynthetic therapies have been developed to rescue ischemic tissue by taking up tissue-derived carbon dioxide and in turn releasing oxygen for sustained aerobic metabolism during ischemia. In this article, we review the application of cyanobacteria, specifically S. elongatus, in the field of biotechnology, ischemic heart disease, and other clinical applications in ischemic diseases. We also address the motivation for innovation and current limitations in the field of S. elongatus photosynthetic therapeutics for ischemic cardiovascular disease.


Assuntos
Doenças Cardiovasculares , Isquemia Miocárdica , Dióxido de Carbono/metabolismo , Doenças Cardiovasculares/terapia , Humanos , Isquemia , Fotossíntese
4.
Transpl Int ; 35: 10176, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35340846

RESUMO

Severe primary graft dysfunction (PGD) is the leading cause of early postoperative mortality following orthotopic heart transplantation (OHT). Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) has been used as salvage therapy. This study aimed to evaluate the outcomes in adult OHT recipients who underwent VA-ECMO for severe PGD. We retrospectively reviewed 899 adult (≥18 years) patients who underwent primary OHT at our institution between 1997 and 2017. Recipients treated with VA-ECMO (19, 2.1%) exhibited a higher incidence of previous cardiac surgery (p = .0220), chronic obstructive pulmonary disease (p = .0352), and treatment with a calcium channel blocker (p = .0018) and amiodarone (p = .0148). Cardiopulmonary bypass (p = .0410) and aortic cross-clamp times (p = .0477) were longer in the VA-ECMO cohort and they were more likely to have received postoperative transfusion (p = .0013); intra-aortic balloon pump (IABP, p < .0001), and reoperation for bleeding or tamponade (p < .0001). The 30-day, 1-year, and overall survival after transplantation of non-ECMO patients were 95.9, 88.8, and 67.4%, respectively, compared to 73.7, 57.9, and 47.4%, respectively in the ECMO cohort. Fourteen (73.7%) of the ECMO patients were weaned after a median of 7 days following OHT (range: 1-12 days). Following OHT, VA-ECMO may be a useful salvage therapy for severe PGD and can potentially support the usage of marginal donor hearts.


Assuntos
Oxigenação por Membrana Extracorpórea , Transplante de Coração , Disfunção Primária do Enxerto , Adulto , Oxigenação por Membrana Extracorpórea/efeitos adversos , Transplante de Coração/efeitos adversos , Humanos , Disfunção Primária do Enxerto/epidemiologia , Disfunção Primária do Enxerto/etiologia , Disfunção Primária do Enxerto/terapia , Estudos Retrospectivos , Doadores de Tecidos
5.
BMC Cardiovasc Disord ; 22(1): 73, 2022 02 26.
Artigo em Inglês | MEDLINE | ID: mdl-35219298

RESUMO

BACKGROUND: Mitral annuloplasty rings restore annular dimensions to increase leaflet coaptation, serving a fundamental component in mitral valve repair. However, biomechanical evaluations of annuloplasty rings are lacking. We aim to biomechanically analyze flexible and rigid annuloplasty rings using an ex vivo mitral annular dilation model. METHODS: Juvenile porcine mitral valves (n = 4) with intercommissural distance of 28 mm were dilated to intercommissural distances of 40 mm using a 3D-printed dilator and were sewn to an elastic mount. Fiber bragg grating sensors were anchored to native chordae to measure chordal forces. The valves were repaired using size 28 rigid and flexible annuloplasty rings in a random order. Hemodynamic data, echocardiography, and chordal force measurements were collected. RESULTS: Mitral annular dilation resulted in decreased leaflet coaptation height and increased mitral regurgitation fraction. Both the flexible and rigid annuloplasty rings effectively increased leaflet coaptation height compared to that post dilation. Rigid ring annuloplasty repair significantly decreased the mitral regurgitation fraction. Flexible annuloplasty ring repair reduced the chordal rate of change of force (7.1 ± 4.4 N/s versus 8.6 ± 5.9 N/s, p = 0.02) and peak force (0.6 ± 0.5 N versus 0.7 ± 0.6 N, p = 0.01) compared to that from post dilation. Rigid annuloplasty ring repair was associated with higher chordal rate of change of force (9.8 ± 5.8 N/s, p = 0.0001) and peak force (0.7 ± 0.5 N, p = 0.01) compared to that after flexible ring annuloplasty repair. CONCLUSIONS: Both rigid and flexible annuloplasty rings are effective in increasing mitral leaflet coaptation height. Although the rigid annuloplasty ring was associated with slightly higher chordal stress compared to that of the flexible annuloplasty ring, it was more effective in mitral regurgitation reduction. This study may help direct the design of an optimal annuloplasty ring to further improve patient outcomes.


Assuntos
Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Animais , Dilatação , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Anuloplastia da Valva Mitral/efeitos adversos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Desenho de Prótese , Suínos
6.
Eur Heart J ; 42(48): 4934-4943, 2021 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-34333595

RESUMO

AIMS: Since 1968, heart transplantation has become the definitive treatment for patients with end-stage heart failure. We aimed to summarize our experience in heart transplantation at Stanford University since the first transplantation performed over 50 years ago. METHODS AND RESULTS: From 6 January 1968 to 30 November 2020, 2671 patients presented to Stanford University for heart transplantation, of which 1958 were adult heart transplantations. Descriptive analyses were performed for patients in 1968-95 (n = 639). Stabilized inverse probability weighting was applied to compare patients in 1996-2006 (n = 356) vs. 2007-19 (n = 515). Follow-up data were updated through 2020. The primary endpoint was all-cause mortality. Prior to weighting, recipients in 2007-19 vs. those in 1996-2006 were older and had heavier burden of chronic diseases. After the application of stabilized inverse probability weighting, the distance organ travelled increased from 84.2 ± 111.1 miles to 159.3 ± 169.9 miles from 1996-2006 to 2007-19. Total allograft ischaemia time also increased over time (199.6 ± 52.7 vs. 225.3 ± 50.0 min). Patients in 2007-19 showed superior survival than those in 1996-2006 with a median survival of 12.1 vs. 11.1 years. CONCLUSION: In this half-century retrospective descriptive study from one of the largest heart transplant programmes in the USA, long-term survival after heart transplantation has improved over time despite increased recipient and donor age, worsening comorbidities, increased technical complexity, and prolonged total allograft ischaemia time. Further investigation is warranted to delineate factors associated with the excellent outcomes observed in this study.


Assuntos
Transplante de Coração , Humanos , Estudos Retrospectivos , Taxa de Sobrevida , Doadores de Tecidos
7.
Circulation ; 142(14): 1361-1373, 2020 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-33017215

RESUMO

BACKGROUND: Many graft configurations are clinically used for valve-sparing aortic root replacement, some specifically focused on recapitulating neosinus geometry. However, the specific impact of such neosinuses on valvular and root biomechanics and the potential influence on long-term durability are unknown. METHODS: Using a custom 3-dimenstional-printed heart simulator with porcine aortic roots (n=5), the anticommissural plication, Stanford modification, straight graft (SG), Uni-Graft, and Valsalva graft configurations were tested in series using an incomplete counterbalanced measures design, with the native root as a control, to mitigate ordering effects. Hemodynamic and videometric data were analyzed using linear models with conduit as the fixed effect of interest and valve as a fixed nuisance effect with post hoc pairwise testing using Tukey's correction. RESULTS: Hemodynamics were clinically similar between grafts and control aortic roots. Regurgitant fraction varied between grafts, with SG and Uni-Graft groups having the lowest regurgitant fractions and anticommissural plication having the highest. Root distensibility was significantly lower in SG versus both control roots and all other grafts aside from the Stanford modification (P≤0.01 for each). All grafts except SG had significantly higher cusp opening velocities versus native roots (P<0.01 for each). Relative cusp opening forces were similar between SG, Uni-Graft, and control groups, whereas anticommissural plication, Stanford modification, and Valsalva grafts had significantly higher opening forces versus controls (P<0.01). Cusp closing velocities were similar between native roots and the SG group, and were significantly lower than observed in the other conduits (P≤0.01 for each). Only SG and Uni-Graft groups experienced relative cusp closing forces approaching that of the native root, whereas relative forces were >5-fold higher in the anticommissural plication, Stanford modification, and Valsalva graft groups. CONCLUSIONS: In this ex vivo modeling system, clinically used valve-sparing aortic root replacement conduit configurations have comparable hemodynamics but differ in biomechanical performance, with the straight graft most closely recapitulating native aortic root biomechanics.


Assuntos
Aorta/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Implante de Prótese Vascular , Prótese Vascular , Modelos Cardiovasculares , Impressão Tridimensional , Animais , Humanos , Suínos
8.
J Card Surg ; 31(9): 572-4, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27405799

RESUMO

Paravalvular leak-related aortic regurgitation after transcatheter aortic valve replacement (TAVR) is a common complication and is associated with increased short- and long-term mortality. However, the impact of isolated central aortic regurgitation is unknown. We report a case of transapical (TA) TAVR with postprocedural central aortic regurgitation, who returned after two years with progression of regurgitation. A reoperative valve-in-valve TA-TAVR was performed.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Reoperação , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Insuficiência da Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Ecocardiografia Transesofagiana , Humanos , Masculino , Resultado do Tratamento
9.
Cardiovasc Eng Technol ; 15(2): 224-231, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38238600

RESUMO

PURPOSE: The valve-sparing aortic root replacement (VSARR) procedure was developed to preserve the aortic valve apparatus to replace aneurysmal aortic roots with synthetic grafts and to eliminate associated aortic regurgitation (AR). However, residual post-repair AR is not uncommon and has been found to be associated with recurrent AR and future reoperation. METHODS: We designed and manufactured a 3D-printed, external adjustable symmetrically extensible (EASE) aortic annuloplasty ring that can symmetrically reduce the aortic annulus diameter via a radial constriction, compliant mechanism. An ex vivo porcine VSARR model with annular dilation and AR was developed (n = 4) and used for hemodynamic, echocardiography, and high-speed videography data collection. RESULTS: After ring annuloplasty repair using the EASE aortic ring, the regurgitant fraction decreased from 23.6 ± 6.9% from the VSARR model to 7.4 ± 5.6% (p = 0.05), which was similar to that measured from baseline with a regurgitant fraction of 10.2 ± 3.9% (p = 0.34). The leaflet coaptation height after annuloplasty repair also significantly increased from that measured in VSARR model (0.4 ± 0.1 cm) to 0.9 ± 0.1 cm (p = 0.0004), a level similar to that measured in baseline (1.1 ± 0.1 cm, p = 0.28). CONCLUSION: Using an ex vivo VSARR model, the EASE ring successfully reduced AR by reducing the annular diameter and improving leaflet coaptation. With its broad applicability and ease of use, this device has the potential to have a significant impact on patients suffering worldwide from AR due to root aneurysms.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica , Anuloplastia da Valva Cardíaca , Próteses Valvulares Cardíacas , Hemodinâmica , Impressão Tridimensional , Desenho de Prótese , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Animais , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Anuloplastia da Valva Cardíaca/instrumentação , Sus scrofa , Implante de Prótese de Valva Cardíaca/instrumentação , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Modelos Animais de Doenças , Modelos Cardiovasculares
10.
Innovations (Phila) ; 19(1): 88-91, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38258625

RESUMO

Heart transplantation utilizing deceased after circulatory death (DCD) donors has expanded the donor pool through the use of ex vivo normothermic perfusion. Compared with brain death donation, the conventional method of performing DCD heart transplantation includes an additional period of warm and cold ischemia. We have developed a beating heart implantation technique that obliviates the need for a second cardioplegic arrest and the associated reperfusion injury. We hypothesize this reproducible method may improve short-term and long-term outcomes to mirror results seen in brain death donors and provide details on how to perform beating heart transplantation.


Assuntos
Morte Encefálica , Transplante de Coração , Humanos , Transplante de Coração/métodos , Doadores de Tecidos , Perfusão/métodos
11.
J Thorac Cardiovasc Surg ; 167(4): e78-e89, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37160219

RESUMO

OBJECTIVE: Estimating neochord lengths during mitral valve repair is challenging, because approximation must be performed largely based on intuition and surgical experience. Little data exist on quantifying the effects of neochord length misestimation. We aimed to evaluate the impact of neochord length on papillary muscle forces and mitral valve hemodynamics, which is especially pertinent because increased forces have been linked to aberrant mitral valve biomechanics. METHODS: Porcine mitral valves (n = 8) were mounted in an ex vivo heart simulator, and papillary muscles were fixed to high-resolution strain gauges while hemodynamic data were recorded. We used an adjustable system to modulate neochord lengths. Optimal length was qualitatively verified by a single experienced operator, and neochordae were randomly lengthened or shortened in 1-mm increments up to ±5 mm from the optimal length. RESULTS: Optimal length neochordae resulted in the lowest peak composite papillary muscle forces (6.94 ± 0.29 N), significantly different from all lengths greater than ±1 mm. Both longer and shorter neochordae increased forces linearly according to difference from optimal length. Both peak papillary muscle forces and mitral regurgitation scaled more aggressively for longer versus shorter neochordae by factors of 1.6 and 6.9, respectively. CONCLUSIONS: Leveraging precision ex vivo heart simulation, we found that millimeter-level neochord length differences can result in significant differences in papillary muscle forces and mitral regurgitation, thereby altering valvular biomechanics. Differences in lengthened versus shortened neochordae scaling of forces and mitral regurgitation may indicate different levels of biomechanical tolerance toward longer and shorter neochordae. Our findings highlight the need for more thorough biomechanical understanding of neochordal mitral valve repair.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Animais , Suínos , Músculos Papilares/cirurgia , Insuficiência da Valva Mitral/cirurgia , Fenômenos Biomecânicos , Cordas Tendinosas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos
12.
Atherosclerosis ; 395: 117518, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38627162

RESUMO

BACKGROUND AND AIMS: There are a limited number of pharmacologic therapies for coronary artery disease, and few rodent models of occlusive coronary atherosclerosis and consequent myocardial infarction with which one can rapidly test new therapeutic approaches. Here, we characterize a novel, fertile, and easy-to-use HDL receptor (SR-B1)-based model of atherogenic diet-inducible, fatal coronary atherosclerosis, the SR-B1ΔCT/LDLR KO mouse. Additionally, we test intramyocardial injection of Stromal Cell-Derived Factor-1 alpha (SDF-1α), a potent angiogenic cytokine, as a possible therapy to rescue cardiac function in this mouse. METHODS: SR-B1ΔCT/LDLR KO mice were fed the Paigen diet or standard chow diet, and we determined the effects of the diets on cardiac function, histology, and survival. After two weeks of feeding either the Paigen diet (n = 24) or standard chow diet (n = 20), the mice received an intramyocardial injection of either SDF-1α or phosphate buffered saline (PBS). Cardiac function and angiogenesis were assessed two weeks later. RESULTS: When six-week-old mice were fed the Paigen diet, they began to die as early as 19 days later and 50% had died by 38 days. None of the mice maintained on the standard chow diet died by day 72. Hearts from mice on the Paigen diet showed evidence of cardiomegaly, myocardial infarction, and occlusive coronary artery disease. For the five mice that survived until day 28 that underwent an intramyocardial injection of PBS on day 15, the average ejection fraction (EF) decreased significantly from day 14 (the day before injection, 52.1 ± 4.3%) to day 28 (13 days after the injection, 30.6 ± 6.8%) (paired t-test, n = 5, p = 0.0008). Of the 11 mice fed the Paigen diet and injected with SDF-1α on day 15, 8 (72.7%) survived to day 28. The average EF for these 8 mice increased significantly from 48.2 ± 7.2% on day 14 to63.6 ± 6.9% on day 28 (Paired t-test, n = 8, p = 0.003). CONCLUSIONS: This new mouse model and treatment with the promising angiogenic cytokine SDF-1α may lead to new therapeutic approaches for ischemic heart disease.


Assuntos
Quimiocina CXCL12 , Doença da Artéria Coronariana , Modelos Animais de Doenças , Camundongos Knockout , Receptores de LDL , Receptores Depuradores Classe B , Animais , Quimiocina CXCL12/metabolismo , Quimiocina CXCL12/genética , Receptores de LDL/genética , Receptores de LDL/deficiência , Receptores Depuradores Classe B/genética , Masculino , Neovascularização Fisiológica/efeitos dos fármacos , Camundongos Endogâmicos C57BL , Dieta Aterogênica , Camundongos , Função Ventricular Esquerda , Miocárdio/patologia , Miocárdio/metabolismo , Dieta Hiperlipídica
13.
Artigo em Inglês | MEDLINE | ID: mdl-39111693

RESUMO

OBJECTIVE: Ex-vivo normothermic perfusion of cardiac allografts has expanded the donor pool. Utilizing a beating heart implantation method avoids the second cardioplegic arrest and subsequent ischemia reperfusion injury typically associated with ex-vivo heart perfusion. We sought to describe our institutional experience with beating heart transplantation. METHODS: This was a single-institution retrospective study of adult patients who underwent heart transplantation utilizing ex-vivo heart perfusion (EVHP) and a beating heart implantation technique between October 2022 and March 2024. Primary outcomes of interest included survival, initiation of mechanical circulatory support, and rejection. A sub-analysis of our institutional series of non-beating DCD heart transplantation was also performed. RESULTS: Twenty-four patients underwent isolated heart transplantation with the use of ex-vivo heart perfusion and beating heart implantation between October 2022 and March 2024; 21 (87.5%) received hearts from DCD donors, and 3 (12.5%) patients received hearts from DBD donors. Median follow-up was 192 days (interquartile range of 124-253.5 days), and 23 out of 24 patients (95.8%) were alive at last follow up. No patients required initiation of mechanical circulatory support. The majority of patients had pathological grade 0 rejection at the time of biopsy (n=16, 66.7%), and the median cell-free DNA percent was 0.04% (interquartile range 0.04-0.09). The rate of mechanical circulatory support initiation in the 22-patient non-beating DCD heart transplant cohort was significantly higher at 36.4% (p<0.005). CONCLUSIONS: A beating heart implantation technique can be used on DCD and DBD hearts on EVHP and is associated with excellent survival and low levels of rejection.

14.
JTCVS Tech ; 25: 1-7, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38899072

RESUMO

Objective: To investigate the effect of graft sizing on valve performance in valve-sparing aortic root replacement for bicuspid aortic valve. Methods: In addition to a diseased control model, 3 representative groups-free-edge length to aortic/graft diameter (FELAD) ratio <1.3, 1.5 to 1.64, and >1.7-were replicated in explanted porcine aortic roots (n = 3) using straight grafts sized respective to the native free-edge length. They were run on a validated ex vivo univentricular system under physiological parameters for 20 cycles. All groups were tested within the same aortic root to minimize inter-root differences. Outcomes included transvalvular gradient, regurgitation fraction, and orifice area. Linear mixed effects model and pairwise comparisons were employed to compare outcomes across groups. Results: The diseased control had mean transvalvular gradient 10.9 ± 6.30 mm Hg, regurgitation fraction 32.5 ± 4.91%, and orifice area 1.52 ± 0.12 cm2. In ex vivo analysis, all repair groups had improved regurgitation compared with control (P < .001). FELAD <1.3 had the greatest amount of regurgitation among the repair groups (P < .001) and 1.5-1.64 the least (P < .001). FELAD <1.3 and >1.7 exhibited greater mean gradient compared with both control and 1.5 to 1.64 (P < .001). Among the repair groups, 1.5 to 1.64 had the largest orifice area, and >1.7 the smallest (P < .001). Conclusions: For a symmetric bicuspid aortic valve, performance after valve-sparing aortic root replacement shows a bimodal distribution across graft size. As the FELAD ratio departs from 1.5 to 1.64 in either direction, significant increases in transvalvular gradient are observed. FELAD <1.3 may also result in suboptimal improvement of baseline regurgitation.

15.
Artigo em Inglês | MEDLINE | ID: mdl-39187122

RESUMO

OBJECTIVE: Combined heart-liver transplantation (CHLT) is a definitive therapy reserved for patients with concomitant heart failure and advanced liver disease. A limited number of centers perform CHLT, and even fewer use the en bloc implantation technique. This study 1) reviews clinical outcomes and immunoprotective effects following CHLT, and 2) describes our institution's experience of over two decades using the en bloc technique. METHODS: All patients who underwent CHLT at our institution between January 2003 and July 2023 were identified. Recipient and donor characteristics, operative details, and clinical outcomes were assessed. Kaplan-Meier analysis was performed to evaluate survival following CHLT. RESULTS: A total of 20 patients underwent CHLT using the en bloc technique at our institution between January 2003 and July 2023. At a median follow-up of 3.8 years for patients who survived the perioperative period (n=18), estimated survival at 1- and 5-years was 94% and 75%, respectively. There was 100% freedom from acute moderate rejection, acute severe rejection, and chronic rejection in all patients. No patients required re-transplantation due to rejection. CONCLUSIONS: CHLT is a definitive therapy reserved for patients with multi-organ dysfunction. At our institution, the en bloc technique is the preferred operative approach, as it minimizes cardiac insult, requires fewer anastomoses, minimizes cold ischemia time, and allows for rapid correction of coagulopathy. Overall survival for this cohort is excellent. Episodes of acute rejection were rarely observed, providing further support that the liver may serve an immunoprotective role in multi-organ transplantation.

16.
Eur J Cardiothorac Surg ; 65(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38258541

RESUMO

OBJECTIVES: Artificial neochordae implantation is commonly used for mitral valve (MV) repair. However, neochordae length estimation can be difficult to perform. The objective was to assess the impact of neochordae length changes on MV haemodynamics and neochordal forces. METHODS: Porcine MVs (n = 6) were implanted in an ex vivo left heart simulator. MV prolapse (MVP) was generated by excising at least 2 native primary chordae supporting the P2 segments from each papillary muscle. Two neochordae anchored on each papillary muscle were placed with 1 tied to the native chord length (exact length) and the other tied with variable lengths from 2× to 0.5× of the native length (variable length). Haemodynamics, neochordal forces and echocardiography data were collected. RESULTS: Neochord implantation repair successfully eliminated mitral regurgitation with repaired regurgitant fractions of approximately 4% regardless of neochord length (P < 0.01). Leaflet coaptation height also significantly improved to a minimum height of 1.3 cm compared with that of MVP (0.9 ± 0.4 cm, P < 0.05). Peak and average forces on exact length neochordae increased as variable length neochordae lengths increased. Peak and average forces on the variable length neochordae increased with shortened lengths. Overall, chordal forces appeared to vary more drastically in variable length neochordae compared with exact length neochordae. CONCLUSIONS: MV regurgitation was eliminated with neochordal repair, regardless of the neochord length. However, chordal forces varied significantly with different neochord lengths, with a preferentially greater impact on the variable length neochord. Further validation studies may be performed before translating to clinical practices.


Assuntos
Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Animais , Suínos , Valva Mitral/cirurgia , Cordas Tendinosas/cirurgia , Desenho de Prótese , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/cirurgia
17.
J Thorac Cardiovasc Surg ; 168(2): 581-592.e4, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38320627

RESUMO

OBJECTIVE: The objective of this study is to evaluate survival for combined heart-lung transplant (HLTx) recipients across 4 decades at a single institution. We aim to summarize our contemporary practice based on more than 271 HLTx procedures over 40 years. METHODS: Data were collected from a departmental database and the United Network for Organ Sharing. Recipients younger than age 18 years, those undergoing redo HLTx, or triple-organ system transplantation were excluded, leaving 271 patients for analysis. The pioneering era was defined by date of transplant between 1981 and 2000 (n = 155), and the modern era between 2001 and 2022 (n = 116). Survival analysis was performed using cardinality matching of populations based on donor and recipient age, donor and recipient sex, ischemic time, and sex matching. RESULTS: Between 1981 and 2022, 271 HLTx were performed at a single institution. Recipients in the modern era were older (age 42 vs 34 y; P < .001) and had shorter waitlist times (78 vs 234 days; P < .001). Allografts from female donors were more common in the modern era (59% vs 39%; P = .002). In the matched survival analysis, 30-day survival (97% vs 84%; P = .005), 1-year survival (89% vs 77%; P = .041), and 10-year survival (53% vs 26%; P = .012) significantly improved in the modern era relative to the pioneering era, respectively. CONCLUSIONS: Long-term survival in HLTx is achievable with institutional experience and may continue to improve in the coming decades. Advances in mechanical circulatory support, improved maintenance immunosuppression, and early recognition and management of acute complications such as primary graft dysfunction and acute rejection have dramatically improved the prognosis for recipients of HLTx in our contemporary institutional experience.


Assuntos
Transplante de Coração-Pulmão , Humanos , Feminino , Transplante de Coração-Pulmão/mortalidade , Transplante de Coração-Pulmão/efeitos adversos , Masculino , Adulto , Pessoa de Meia-Idade , Fatores de Tempo , Estudos Retrospectivos , Sobrevivência de Enxerto , Resultado do Tratamento , Fatores de Risco , Adulto Jovem , Bases de Dados Factuais , Rejeição de Enxerto , Listas de Espera/mortalidade
18.
Circ Cardiovasc Interv ; 17(4): e013196, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38626077

RESUMO

BACKGROUND: Various mitral repair techniques have been described. Though these repair techniques can be highly effective when performed correctly in suitable patients, limited quantitative biomechanical data are available. Validation and thorough biomechanical evaluation of these repair techniques from translational large animal in vivo studies in a standardized, translatable fashion are lacking. We sought to evaluate and validate biomechanical differences among different mitral repair techniques and further optimize repair operations using a large animal mitral valve prolapse model. METHODS: Male Dorset sheep (n=20) had P2 chordae severed to create the mitral valve prolapse model. Fiber Bragg grating force sensors were implanted to measure chordal forces. Ten sheep underwent 3 randomized, paired mitral valve repair operations: neochord repair, nonresectional leaflet remodeling, and triangular resection. The other 10 sheep underwent neochord repair with 2, 4, and 6 neochordae. Data were collected at baseline, mitral valve prolapse, and after each repair. RESULTS: All mitral repair techniques successfully eliminated regurgitation. Compared with mitral valve prolapse (0.54±0.18 N), repair using neochord (0.37±0.20 N; P=0.02) and remodeling techniques (0.30±0.15 N; P=0.001) reduced secondary chordae peak force. Neochord repair further decreased primary chordae peak force (0.21±0.14 N) to baseline levels (0.20±0.17 N; P=0.83), and was associated with lower primary chordae peak force compared with the remodeling (0.34±0.18 N; P=0.02) and triangular resectional techniques (0.36±0.27 N; P=0.03). Specifically, repair using 2 neochordae resulted in higher peak primary chordal forces (0.28±0.21 N) compared with those using 4 (0.22±0.16 N; P=0.02) or 6 neochordae (0.19±0.16 N; P=0.002). No difference in peak primary chordal forces was observed between 4 and 6 neochordae (P=0.05). Peak forces on the neochordae were the lowest using 6 neochordae (0.09±0.11 N) compared with those of 4 neochordae (0.15±0.14 N; P=0.01) and 2 neochordae (0.29±0.18 N; P=0.001). CONCLUSIONS: Significant biomechanical differences were observed underlying different mitral repair techniques in a translational large animal model. Neochord repair was associated with the lowest primary chordae peak force compared to the remodeling and triangular resectional techniques. Additionally, neochord repair using at least 4 neochordae was associated with lower chordal forces on the primary chordae and the neochordae. This study provided key insights about mitral valve repair optimization and may further improve repair durability.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Humanos , Masculino , Animais , Ovinos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Cordas Tendinosas/cirurgia , Resultado do Tratamento
19.
Bioengineering (Basel) ; 10(7)2023 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-37508869

RESUMO

Cardiovascular diseases are the leading cause of morbidity and mortality in the United States. Cardiac tissue engineering is a direction in regenerative medicine that aims to repair various heart defects with the long-term goal of artificially rebuilding a full-scale organ that matches its native structure and function. Three-dimensional (3D) bioprinting offers promising applications through its layer-by-layer biomaterial deposition using different techniques and bio-inks. In this review, we will introduce cardiac tissue engineering, 3D bioprinting processes, bioprinting techniques, bio-ink materials, areas of limitation, and the latest applications of this technology, alongside its future directions for further innovation.

20.
JTCVS Open ; 14: 77-86, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37425479

RESUMO

Objectives: Although bioprosthetic valves have excellent hemodynamic properties and can eliminate the need for lifelong anticoagulation therapy, these devices are associated with high rates of reoperation and limited durability. Although there are many distinct bioprosthesis designs, all bioprosthetic valves have historically featured a trileaflet pattern. This in silico study examines the biomechanical effect of modulating the number of leaflets in a bioprosthetic valve. Methods: Bioprosthetic valves with 2 to 6 leaflets were designed in Fusion 360 using quadratic spline geometry. Leaflets were modeled with standard mechanical parameters for fixed bovine pericardial tissue. A mesh of each design was structurally evaluated using finite element analysis software Abaqus CAE. Maximum von Mises stresses during valve closure were assessed for each leaflet geometry in both the aortic and mitral position. Results: Computational analysis demonstrated that increasing the number of leaflets is associated with reduction in leaflet stresses. Compared with the standard trileaflet design, a quadrileaflet pattern reduces leaflet maximum von Mises stresses by 36% in the aortic position and 38% in the mitral position. Maximum stress was inversely proportional to the square of the leaflet quantity. Surface area increased linearly and central leakage increased quadratically with leaflet quantity. Conclusions: A quadrileaflet pattern was found to reduce leaflet stresses while limiting increases in central leakage and surface area. These findings suggest that modulating the number of leaflets can allow for optimization of the current bioprosthetic valve design, which may translate to more durable valve replacement bioprostheses.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA