J Proteome Res ; 10(2): 907-12, 2011 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-21126090

RESUMO

A "one-pot" alternative method for processing proteins and isolating peptide mixtures from bacterial samples is presented for liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis and data reduction. The conventional in-solution digestion of the protein contents of bacteria is compared to a small disposable filter unit placed inside a centrifuge vial for processing and digestion of bacterial proteins. Each processing stage allows filtration of excess reactants and unwanted byproduct while retaining the proteins. Upon addition of trypsin, the peptide mixture solution is passed through the filter while retaining the trypsin enzyme. The peptide mixture is then analyzed by LC-MS/MS with an in-house BACid algorithm for a comparison of the experimental unique peptides to a constructed proteome database of bacterial genus, specie, and strain entries. The concentration of bacteria was varied from 10 × 10(7) to 3.3 × 10(3) cfu/mL for analysis of the effect of concentration on the ability of the sample processing, LC-MS/MS, and data analysis methods to identify bacteria. The protein processing method and dilution procedure result in reliable identification of pure suspensions and mixtures at high and low bacterial concentrations.


Assuntos
Bactérias/classificação , Proteínas de Bactérias/análise , Filtração/métodos , Fragmentos de Peptídeos/análise , Proteômica/métodos , Espectrometria de Massas em Tandem/métodos , Animais , Bactérias/química , Proteínas de Bactérias/metabolismo , Cromatografia Líquida , Análise por Conglomerados , Bases de Dados de Proteínas , Cavalos , Modelos Estatísticos , Mioglobina/análise , Fragmentos de Peptídeos/metabolismo , Tripsina/metabolismo
2.
J Proteome Res ; 9(7): 3647-55, 2010 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-20486690

RESUMO

Whole cell protein and outer membrane protein (OMP) extracts were compared for their ability to differentiate and delineate the correct database organism to an experimental sample and for the degree of dissimilarity to the nearest neighbor database organism strains. These extracts were isolated from pathogenic and nonpathogenic strains of Yersinia pestis and Escherichia coli using ultracentrifugation and a sarkosyl extraction method followed by protein digestion and analysis using liquid chromatography tandem mass spectrometry (MS). Whole cell protein extracts contain many different types of proteins resident in an organism at a given phase in its growth cycle. OMPs, however, are often associated with virulence in Gram-negative pathogens and could prove to be model biomarkers for strain differentiation among bacteria. The mass spectra of bacterial peptides were searched, using the SEQUEST algorithm, against a constructed proteome database of microorganisms in order to determine the identity and number of unique peptides for each bacterial sample. Data analysis was performed with the in-house BACid software. It calculated the probabilities that a peptide sequence assignment to a product ion mass spectrum was correct and used accepted spectrum-to-sequence matches to generate a sequence-to-bacterium (STB) binary matrix of assignments. Validated peptide sequences, either present or absent in various strains (STB matrices), were visualized as assignment bitmaps and analyzed by the BACid module that used phylogenetic relationships among bacterial species as part of a decision tree process. The bacterial classification and identification algorithm used assignments of organisms to taxonomic groups (phylogenetic classification) based on an organized scheme that begins at the phylum level and follows through the class, order, family, genus, and species to the strain level. For both Gram-negative organisms, the number of unique distinguishing proteins arrived at by the whole cell method was less than that of the OMP method. However, the degree of differentiation measured in linkage distance units on a dendrogram with the OMP extract showed similar or significantly better separation than the whole cell protein extract method between the sample and correct database match compared to the next nearest neighbor. The nonpathogenic Y. pestis A1122 strain used does not have its genome available, and thus, data analysis resulted in an equal similarity index to the nonpathogenic 91001 and pathogenic Antiqua and Nepal 516 strains for both extraction methods. Pathogenic and nonpathogenic strains of E. coli were correctly identified with both protein extraction methods, and the pathogenic Y. pestis CO92 strain was correctly identified with the OMP procedure. Overall, proteomic MS proved useful in the analysis of unique protein assignments for strain differentiation of E. coli and Y. pestis. The power of bacterial protein capture by the whole cell protein and OMP extraction methods was highlighted by the data analysis techniques and revealed differentiation and similarities between the two protein extraction approaches for bacterial delineation capability.


Assuntos
Proteínas da Membrana Bacteriana Externa , Escherichia coli O157/isolamento & purificação , Proteômica/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Yersinia pestis/isolamento & purificação , Proteínas da Membrana Bacteriana Externa/química , Proteínas da Membrana Bacteriana Externa/classificação , Proteínas de Bactérias/química , Proteínas de Bactérias/classificação , Extratos Celulares/química , Análise por Conglomerados , Biologia Computacional/métodos , Bases de Dados de Proteínas , Especificidade da Espécie , Espectrometria de Massas em Tandem/métodos
3.
Appl Environ Microbiol ; 76(11): 3637-44, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20363779

RESUMO

Due to the possibility of a biothreat attack on civilian or military installations, a need exists for technologies that can detect and accurately identify pathogens in a near-real-time approach. One technology potentially capable of meeting these needs is a high-throughput mass spectrometry (MS)-based proteomic approach. This approach utilizes the knowledge of amino acid sequences of peptides derived from the proteolysis of proteins as a basis for reliable bacterial identification. To evaluate this approach, the tryptic digest peptides generated from double-blind biological samples containing either a single bacterium or a mixture of bacteria were analyzed using liquid chromatography-tandem mass spectrometry. Bioinformatic tools that provide bacterial classification were used to evaluate the proteomic approach. Results showed that bacteria in all of the double-blind samples were accurately identified with no false-positive assignment. The MS proteomic approach showed strain-level discrimination for the various bacteria employed. The approach also characterized double-blind bacterial samples to the respective genus, species, and strain levels when the experimental organism was not in the database due to its genome not having been sequenced. One experimental sample did not have its genome sequenced, and the peptide experimental record was added to the virtual bacterial proteome database. A replicate analysis identified the sample to the peptide experimental record stored in the database. The MS proteomic approach proved capable of identifying and classifying organisms within a microbial mixture.


Assuntos
Bactérias/química , Bactérias/classificação , Proteínas de Bactérias/análise , Espectrometria de Massas/métodos , Proteômica/métodos , Proteínas de Bactérias/metabolismo , Biologia Computacional/métodos , Método Duplo-Cego , Sensibilidade e Especificidade , Tripsina/metabolismo
4.
Photochem Photobiol ; 89(1): 127-31, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-22803834

RESUMO

A 2010 study exposed Staphylococcus aureus to ultraviolet (UV) radiation and thermal heating from pulsed xenon flash lamps. The results suggested that disinfection could be caused not only by photochemical changes from UV radiation, but also by photophysical stress damage caused by the disturbance from incoming pulses. The study called for more research in this area. The recent advances in light-emitting diode (LED) technology include the development of LEDs that emit in narrow bands in the ultraviolet-C (UV-C) range (100-280 nm), which is highly effective for UV disinfection of organisms. Further, LEDs would use less power, and allow more flexibility than other sources of UV energy in that the user may select various pulse repetition frequencies (PRFs), pulse irradiances, pulse widths, duty cycles and types of waveform output (e.g. square waves, sine waves, triangular waves, etc.). Our study exposed Escherichia coli samples to square pulses of 272 nm radiation at various PRFs and duty cycles. A statistically significant correlation was found between E. coli's disinfection sensitivity and these parameters. Although our sample size was small, these results show promise and are worthy of further investigation. Comparisons are also made with pulsed disinfection by LEDs emitting at 365 nm, and pulsed disinfection by xenon flash lamps.


Assuntos
Desinfecção/métodos , Escherichia coli/efeitos da radiação , Carga Bacteriana , Escherichia coli/crescimento & desenvolvimento , Dispositivos Ópticos , Raios Ultravioleta
5.
Int J Microbiol ; 2011: 132627, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21792355

RESUMO

Development of a rapid field test is needed capable of determining if field supplies of water are safe to drink by the warfighter during a military operation. The present study sought to assess the effectiveness of handheld assays (HHAs) in detecting ricin and Staphylococcal Enterotoxin B (SEB) in water. Performance of HHAs was evaluated in formulated tap water with and without chlorine, reverse osmosis water (RO) with chlorine, and RO with bromine. Each matrix was prepared, spiked with ricin or SEB at multiple concentrations, and then loaded onto HHAs. HHAs were allowed to develop and then read visually. Limits of detection (LOD) were determined for all HHAs in each water type. Both ricin and SEB were detected by HHAs in formulated tap water at or below the suggested health effect levels of 455 ng/mL and 4.55 ng/mL, respectively. However, in brominated or chlorinated waters, LODs for SEB increased to approximately 2,500 ng/mL. LODs for ricin increased in chlorinated water, but still remained below the suggested health effect level. In brominated water, the LOD for ricin increased to approximately 2,500 ng/mL. In conclusion, the HHAs tested were less effective at detecting ricin and SEB in disinfected water, as currently configured.

6.
Int J Microbiol ; 2010: 412694, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21197430

RESUMO

Protecting civilian and military water supplies has received more attention since the United States began its war on terror in 2001. Both chlorine and bromine are used by branches of the U.S. military for disinfecting water supplies; however, limited data exists as to the effectiveness of these additives when used against viral biowarfare agents. The present study sought to evaluate the survival of selected viral biothreat agents in disinfected water. Disinfected water samples were spiked with vaccinia virus strain WR and Venezuelan equine encephalitis (VEE) virus strain TC-83 each separately to a final concentration of approximately 1 × 10(6) PFU/mL, and survival was assessed by plaque assay. Both viruses were inactivated by 1 mg/L free available chlorine (FAC) and 2mg/L total bromine within one hour. In conclusion, these results demonstrate that both chlorine and bromine are effective disinfectants against vaccinia virus and VEE strain TC-83 at the concentrations tested.

7.
PLoS One ; 5(10): e13181, 2010 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-20949138

RESUMO

BACKGROUND: In 2010 Colony Collapse Disorder (CCD), again devastated honey bee colonies in the USA, indicating that the problem is neither diminishing nor has it been resolved. Many CCD investigations, using sensitive genome-based methods, have found small RNA bee viruses and the microsporidia, Nosema apis and N. ceranae in healthy and collapsing colonies alike with no single pathogen firmly linked to honey bee losses. METHODOLOGY/PRINCIPAL FINDINGS: We used Mass spectrometry-based proteomics (MSP) to identify and quantify thousands of proteins from healthy and collapsing bee colonies. MSP revealed two unreported RNA viruses in North American honey bees, Varroa destructor-1 virus and Kakugo virus, and identified an invertebrate iridescent virus (IIV) (Iridoviridae) associated with CCD colonies. Prevalence of IIV significantly discriminated among strong, failing, and collapsed colonies. In addition, bees in failing colonies contained not only IIV, but also Nosema. Co-occurrence of these microbes consistently marked CCD in (1) bees from commercial apiaries sampled across the U.S. in 2006-2007, (2) bees sequentially sampled as the disorder progressed in an observation hive colony in 2008, and (3) bees from a recurrence of CCD in Florida in 2009. The pathogen pairing was not observed in samples from colonies with no history of CCD, namely bees from Australia and a large, non-migratory beekeeping business in Montana. Laboratory cage trials with a strain of IIV type 6 and Nosema ceranae confirmed that co-infection with these two pathogens was more lethal to bees than either pathogen alone. CONCLUSIONS/SIGNIFICANCE: These findings implicate co-infection by IIV and Nosema with honey bee colony decline, giving credence to older research pointing to IIV, interacting with Nosema and mites, as probable cause of bee losses in the USA, Europe, and Asia. We next need to characterize the IIV and Nosema that we detected and develop management practices to reduce honey bee losses.


Assuntos
Abelhas/virologia , Colapso da Colônia , Iridovirus/patogenicidade , Microsporídios/patogenicidade , Animais , Espectrometria de Massas , Estados Unidos