RESUMO
BACKGROUND: Patients aged ≥80â¯years are often treated with new-generation drug-eluting stents (DES), but data from randomized studies are scarce owing to underrepresentation in most trials. We assessed 1-year clinical outcome of octogenarians treated with new-generation DES versus younger patients. METHODS: We pooled patient-level data of 9,204 participants in the TWENTE, DUTCH PEERS, BIO-RESORT, and BIONYX (TWENTE I-IV) randomized trials. The main clinical end point was target vessel failure (TVF), a composite of cardiac death, target vessel-related myocardial infarction (MI), or clinically indicated target vessel revascularization. RESULTS: The 671 octogenarian trial participants had significantly more comorbidities. TVF was higher in octogenarians than in 8,533 patients <80â¯years (7.3% vs 5.3%, hazard ratio [HR]: 1.36, 95% CI: 1.0-1.83, Pâ¯=â¯.04). The cardiac death rate was higher in octogenarians (3.9% vs 0.8%, Pâ¯<â¯.001). There was no significant between-group difference in target vessel MI (2.3% vs 2.3%, Pâ¯=â¯.88) and repeat target vessel revascularization (1.9% vs 2.8%, Pâ¯=â¯.16). In multivariate analyses, ageâ¯≥â¯80â¯years showed no independent association with TVF (adjusted HR: 1.04, 95% CI: 0.76-1.42), whereas the risk of cardiac death remained higher in octogenarians (adjusted HR: 3.38, 95% CI: 2.07-5.52, Pâ¯<â¯.001). In 6,002 trial participants, in whom data on major bleeding were recorded, octogenarians (nâ¯=â¯459) showed a higher major bleeding risk (5.9% vs 1.9%; HR: 3.08, 95% CI: 2.01-4.74, Pâ¯<â¯.001). CONCLUSIONS: Octogenarian participants in 4 large-scale randomized DES trials had more comorbidities and a higher incidence of the main end point TVF. Cardiac mortality was higher in octogenarians, whereas there was no increase in MI or target vessel revascularization rates. Treatment of octogenarian patients with new-generation DES appears to be safe and effective.
Assuntos
Stents Farmacológicos/classificação , Everolimo/farmacologia , Infarto do Miocárdio , Complicações Pós-Operatórias , Sirolimo/análogos & derivados , Sirolimo/farmacologia , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Feminino , Humanos , Imunossupressores/farmacologia , Masculino , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/mortalidade , Reoperação/métodos , Reoperação/estatística & dados numéricos , Risco Ajustado/métodos , Fatores de Risco , Resultado do TratamentoRESUMO
BACKGROUND: Patients with coronary disease may have unknown diabetes or prediabetes. We evaluated 3-year outcomes after percutaneous coronary intervention (PCI) with contemporary drug-eluting stents (DES) in patients with silent diabetes, prediabetes, and normoglycemia. METHODS: All BIO-RESORT trial (NCT01674803) participants without known diabetes, enrolled at our center, were invited for oral glucose tolerance testing (OGTT) and measurements of fasting plasma glucose and glycated hemoglobin (HbA1c). RESULTS: OGTT detected silent diabetes in 68 (6.9%), prediabetes in 132 (13.4%), and normoglycemia in 788 (79.8%) of all 988 study participants. Follow-up was available in 986 (99.8%) patients. The main endpoint target vessel failure (TVF: cardiac death, target vessel-related myocardial infarction [MI], or target vessel revascularization) differed between groups (14.8, 9.9, and 5.6%; p = .002), driven by MI during the first 48 hr and by cardiac death (p < .001; p = .026). Between 48 hr and 3-years, there was no significant between-group difference in TVF, target vessel MI, and target vessel revascularization. Multivariable analysis demonstrated that silent diabetes was independently associated with TVF (adjusted HR: 2.52, 95%-CI: 1.26-5.03). An alternative diagnostic approach-HbA1c and fasting plasma glucose-detected silent diabetes and prediabetes in 33 (3.3%) and 217 (22.0%) patients, and normoglycemia in 738 (74.7%); TVF rates were 12.1, 7.9, and 6.0% (p = .23). CONCLUSION: In patients without known diabetes, abnormal glucose metabolism by OGTT was independently associated with higher 3-year TVF rates after PCI with contemporary DES. This difference was driven by periprocedural MI and cardiac death. After the first 48 hr, the rates of TVF, target vessel MI, and target vessel revascularization were low and did not differ significantly between metabolic groups.
Assuntos
Glicemia/metabolismo , Doença da Artéria Coronariana/terapia , Diabetes Mellitus/diagnóstico , Stents Farmacológicos , Teste de Tolerância a Glucose , Intervenção Coronária Percutânea/instrumentação , Estado Pré-Diabético/diagnóstico , Idoso , Doenças Assintomáticas , Biomarcadores/sangue , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Diabetes Mellitus/sangue , Diabetes Mellitus/mortalidade , Feminino , Hemoglobinas Glicadas/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estado Pré-Diabético/sangue , Estado Pré-Diabético/mortalidade , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
OBJECTIVE: The objective was to assess the 2-year clinical performance of three drug-eluting stents in all-comer patients with severely calcified coronary lesions. BACKGROUND: Severe lesion calcification increases cardiovascular event risk after coronary stenting, but there is a lack of data on the clinical outcome of all-comers with severely calcified lesions who were treated with more recently introduced drug-eluting stents. METHODS: The BIO-RESORT trial (clinicaltrials.gov: NCT01674803) randomly assigned 3,514 all-comer patients to biodegradable polymer Synergy everolimus-eluting stents (EES) or Orsiro sirolimus-eluting stents (SES), versus durable polymer Resolute Integrity zotarolimus-eluting stents (ZES). In a post hoc analysis, we assessed 783 patients (22.3%) with at least one severely calcified target lesion. RESULTS: At 2-year follow-up (available in 99% of patients), the main composite endpoint target vessel failure occurred in 19/252 (7.6%) of the EES and in 33/265 (12.6%) of the ZES-treated patients (p = .07). Target vessel failure occurred in 24/266 (9.1%) of the SES-treated patients (vs. ZES: p = .21). There was a difference in target vessel revascularization, which was required in EES in 6/252 (2.4%) patients and in ZES in 20/265 (7.7%) patients (p = .01); the target vessel revascularization rate in SES was 9/266 (3.4%, vs. ZES: p = .04). Multivariate analysis showed that implantation of EES, but not SES, was independently associated with lower target vessel revascularization rates than in ZES. CONCLUSIONS: In BIO-RESORT participants with severely calcified target lesions, treatment with EES was associated with a lower 2-year target vessel revascularization rate than treatment with ZES.
Assuntos
Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Calcificação Vascular/terapia , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento , Calcificação Vascular/diagnóstico por imagemRESUMO
BACKGROUND: In patients with coronary artery disease, treated with durable polymer-coated drug-eluting stents, the life-long presence of the polymer might delay arterial healing. Novel very thin strut biodegradable polymer stents, which leave only a bare metal stent after polymer resorption, might improve long-term outcome. We investigated in allcomers the safety and efficacy of three stents eluting either everolimus, sirolimus, or zotarolimus, often clinically used but never compared, of which the biodegradable polymer everolimus-eluting stent was never before assessed in allcomers. METHODS: The large-scale, investigator-initiated, multicentre, assessor and patient blinded, three-arm, randomised, BIO-RESORT non-inferiority trial was done at four clinical sites in the Netherlands. All-comer patients were aged 18 years or older, capable of providing informed consent, and required a percutaneous coronary intervention with drug-eluting stent implantation according to clinical guidelines or the operators' judgment. Exclusion criteria were: participation in another randomised drug or device study before reaching the primary endpoint of that study; planned surgery necessitating interruption of dual antiplatelet therapy within the first 6 months; known intolerance to components of the investigational product or medication required; uncertainty about the adherence to follow-up procedures or an assumed life expectancy of less than 1 year; or known pregnancy. Web-based computer-generated allocation sequences randomly assigned patients (1:1:1) to treatment with very thin strut biodegradable polymer everolimus-eluting or sirolimus-eluting stents (which differ substantially in type, amount, distribution, and resorption speed of their respective coating), or thin strut durable polymer zotarolimus-eluting stents. The primary endpoint was a composite of safety (cardiac death or target vessel-related myocardial infarction) and efficacy (target vessel revascularisation) at 12 months of follow up with a very thin strut biodegradable polymer of either everolimus-eluting or sirolimus-eluting stents, compared with durable polymer zotarolimus-eluting stents, analysed by intention to treat (non-inferiority margin 3·5%). This trial was registered with ClinicalTrials.gov, number NCT01674803. FINDINGS: From Dec 21, 2012, to Aug 24, 2015, 3514 patients were enrolled and analysed, of whom 2449 (70%) had acute coronary syndromes, which included 1073 (31%) ST-elevation myocardial infarctions. 12 month follow-up of 3490 (99%) patients (three lost to follow-up; 21 withdrawals) was available. The primary endpoint was met by 55 (5%) of 1172 patients assigned to everolimus-eluting stents, 55 (5%) of 1169 assigned to sirolimus-eluting stents and 63 (5%) of 1173 assigned to zotarolimus-eluting stents. Non-inferiority of the everolimus-eluting stents and sirolimus-eluting stents compared with zotarolimus-eluting stents was confirmed (both -0·7% absolute risk difference, 95% CI -2·4 to 1·1; upper limit of one sided 95% CI 0·8%, pnon-inferiority<0·0001). Definite stent thrombosis (defined by the Academic Research Consortium) occurred in four (0·3%) of 1172 patients who were allocated to everolimus-eluting stents, four (0·3%) of 1169 patients who were allocated to sirolimus-eluting stents, and three (0·3%) of 1173 patients who were allocated to zotarolimus-eluting stents (log-rank p=0·70 for both comparisons with zotarolimus-eluting stents). INTERPRETATION: At 12 month follow-up, both very thin strut drug-eluting stents with dissimilar biodegradable polymer coatings (eluting either everolimus or sirolimus) were non-inferior to the durable polymer stent (eluting zotarolimus) in treating allcomers with a high proportion of patients with acute coronary syndromes. The absence of a loss of 1 year safety and efficacy with the use of these two biodegradable polymer-coated stents is a prerequisite before assessing their potential longer-term benefits. FUNDING: Biotronik, Boston Scientific, and Medtronic.
Assuntos
Síndrome Coronariana Aguda/cirurgia , Antibacterianos/uso terapêutico , Stents Farmacológicos , Everolimo , Sirolimo/análogos & derivados , Sirolimo/uso terapêutico , Implantes Absorvíveis , Idoso , Antibacterianos/administração & dosagem , Doença das Coronárias/cirurgia , Feminino , Humanos , Imunossupressores/uso terapêutico , Masculino , Pessoa de Meia-Idade , Países Baixos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos , Polímeros , Sirolimo/administração & dosagem , Sirolimo/análise , Resultado do TratamentoRESUMO
BACKGROUND: Third-generation, permanent-polymer-based drug-eluting stents with novel, flexible designs might be more easily delivered than previous generations of stents in complex coronary lesions, but might be less longitudinally stable. We aimed to assess the safety and efficacy in all-comer patients of two third-generation stents that are often used clinically, but that have not yet been compared, and one of which has not previously been assessed in a randomised trial. METHODS: In this investigator-initiated, single-blind, multicentre, randomised, two-arm, non-inferiority trial, patients aged 18 years and older who required a percutaneous coronary intervention with implantation of a drug-eluting stent were recruited from four study sites in the Netherlands. We randomly assigned patients by independently managed computer-generated allocation sequences in a 1:1 ratio to receive either cobalt-chromium-based zotarolimus-eluting stents (Resolute Integrity, Medtronic, Santa Rosa, CA, USA) or platinum-chromium-based everolimus-eluting stents (Promus Element, Boston Scientific, Natick, MA, USA). Patients and analysts were masked to the allocated stent, but treating clinicians were not. The primary endpoint of target-vessel failure was a composite of safety (cardiac death or target-vessel-related myocardial infarction) and efficacy (target-vessel revascularisation) at 12 months, analysed by intention to treat (with a non-inferiority margin of 3·6%). This trial is registered with ClinicalTrials.gov, number NCT01331707. FINDINGS: Between Nov 25, 2010, and May 24, 2012, 1811 eligible all-comer patients, with 2371 target lesions, were enrolled in the study. 370 (20%) patients presented with ST-elevation myocardial infarction and 447 (25%) with non-ST-elevation myocardial infarction. 906 patients were assigned to receive zotarolimus-eluting stents and 905 to receive everolimus-eluting stents. Ease of stent delivery was shown by very low numbers of patients requiring treatment other than their assigned study treatment (six [1%] in the zotarolimus-eluting stent group vs five [1%] in the everolimus-eluting stent group; p=0·22). 12-month follow-up results were available for 1810 patients (one patient in the zotarolimus-eluting stent group withdrew consent). The primary endpoint was met by 55 (6%) of 905 patients in the zotarolimus-eluting stent group and 47 (5%) of 905 in the everolimus-eluting stent group. The zotarolimus-eluting stent was non-inferior to the everolimus-eluting stent (absolute risk difference 0·88%, 95% CI -1·24% to 3·01%; upper limit of one-sided 95% CI 2·69%; non-inferiority p=0·006). We noted no significant between-group differences in individual components of the primary endpoint. Definite stent thrombosis occurred in three (0·3%) patients in the zotarolimus-eluting stent group and six (0·7%) patients in the everolimus-eluting stent group (p=0·34). Longitudinal stent deformation was seen only in the everolimus-eluting stent group (nine [1·0%] of 905 vs 0 of 906, p=0·002; nine of 1591 [0·6%] everolimus-eluting stents implanted became deformed), but was not associated with any adverse events. INTERPRETATION: Both stents were similarly efficacious and safe, and provided excellent clinical outcomes, especially in view of the large number of patients who presented with acute myocardial infarctions. FUNDING: Boston Scientific, Medtronic.
Assuntos
Imunossupressores/administração & dosagem , Infarto do Miocárdio/tratamento farmacológico , Intervenção Coronária Percutânea/métodos , Sirolimo/análogos & derivados , Adulto , Idoso , Idoso de 80 Anos ou mais , Oclusão Coronária/tratamento farmacológico , Morte Súbita Cardíaca/etiologia , Stents Farmacológicos , Everolimo , Feminino , Humanos , Imunossupressores/efeitos adversos , Masculino , Pessoa de Meia-Idade , Método Simples-Cego , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Resultado do Tratamento , Adulto JovemRESUMO
BACKGROUND: Only limited data from large randomized clinical trials have been published on the long-term performance of second-generation drug-eluting stents in bifurcation lesions. METHODS: We investigated in patients in the randomized TWENTE trial the long-term safety and efficacy of treating bifurcation lesions with 2 widely applied second-generation drug-eluting stents, the zotarolimus-eluting Resolute stent (Medtronic Inc, Santa Rosa, CA) and the everolimus-eluting Xience V stent (Abbott Vascular, Santa Clara, CA). Three-year follow-up was available in 99.3%. Patients were categorized into treatment for ≥1 bifurcation lesion versus treatment for nonbifurcation lesions only. RESULTS: Among the 1,391 patients of the TWENTE trial, 362 (26%) were treated for bifurcation lesions. At 3-year follow-up, target-vessel failure did not differ between patients treated for bifurcation versus nonbifurcation lesions (13.1% vs 12.6%; P = .84), whereas the periprocedural myocardial infarction rate was higher in patients with bifurcation lesions (6.9% vs 3.1%; P < .01). Of the 362 patients with bifurcation lesion treatment, 179 (49.4%) were treated with Resolute and 183 (50.6%) with Xience V. There was no significant difference in target-vessel failure between the Resolute and Xience V groups with bifurcation treatment (13.6% vs 12.6%; P = .78), and their incidence of definite-or-probable stent thrombosis was low and similar (1.1% vs 0.5%, respectively; P = .62). CONCLUSION: Despite a significant difference in periprocedural myocardial infarction, 3-year clinical outcome after implantation of second-generation stents was favorable and similar for patients with and without bifurcation lesions. In addition, we observed no difference in long-term clinical outcome after bifurcation lesion treatment with Resolute and Xience V stents.
Assuntos
Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Idoso , Doença da Artéria Coronariana/terapia , Everolimo , Feminino , Humanos , Imunossupressores/administração & dosagem , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Revascularização Miocárdica , Intervenção Coronária Percutânea , Desenho de Prótese , Fatores de Risco , Sirolimo/administração & dosagem , Sirolimo/análogos & derivadosRESUMO
OBJECTIVE: To compare long-term outcome of patients treated for chronic total occlusion (CTO) lesions versus patients treated for non-CTO lesions only. BACKGROUND: Percutaneous coronary interventions (PCI) for CTO lesions generally have a higher adverse event risk than PCI for non-CTO lesions. However, long-term outcome data from prospective studies with second-generation drug-eluting stent (DES) use in CTO lesions is scarce. METHODS: We analyzed in this substudy of the TWENTE trial the data of 674 patients, who had stable angina and were electively treated with second-generation DES (Resolute zotarolimus-eluting or Xience V everolimus-eluting stents). Main outcome parameter was target lesion failure (TLF), a composite of cardiac death, target vessel-related myocardial infarction (MI), or target lesion revascularization (TLR). RESULTS: Patients with CTO lesions (n = 59, 8.8%) were more often treated for lesions in small vessels (94.9% vs. 63.1%, P < 0.001), long lesions (52.5% vs. 17.7%, P < 0.001) and multiple vessels (42.4% vs. 22.4%, P < 0.001), and were less often males (62.7% vs. 74.6%, P < 0.05) than patients with non-CTO lesions (n = 615, 91.2%). J-CTO scores ≥2 were present in 56% of CTO lesions. Despite significant differences in characteristics of patients, lesions, and interventional procedures, the TLF rate at 3-year follow-up was similar for both groups (13.6% vs. 12.9%, P = 0.89). In addition, a patient-oriented composite endpoint (any death, MI or revascularization) did not differ between groups (18.6% vs. 18.8%, P = 0.97). CONCLUSION: Patients treated with second-generation DES for CTO lesions showed at 3-year follow-up an incidence of adverse clinical events that was low and similar to patients with non-CTO lesions only.
Assuntos
Oclusão Coronária/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Idoso , Fármacos Cardiovasculares/administração & dosagem , Doença Crônica , Oclusão Coronária/diagnóstico , Oclusão Coronária/mortalidade , Everolimo/administração & dosagem , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Países Baixos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Sirolimo/administração & dosagem , Sirolimo/análogos & derivados , Fatores de Tempo , Resultado do TratamentoRESUMO
OBJECTIVE: To assess the differences in clinical outcome between complex patients treated with Resolute zotarolimus-eluting stents (ZES) versus Xience V everolimus-eluting stents (EES). BACKGROUND: Nowadays, many complex patients with coronary disease are treated with percutaneous coronary interventions, using drug-eluting stents (DES). METHODS: We analyzed 2-year outcome data of 1,033 complex patients of the TWENTE trial, treated with second-generation Resolute ZES or Xience V EES. Complex patients had at least one of the following characteristics: renal insufficiency (creatinine ≥ 140 µmol/l); ejection fraction < 30%; acute myocardial infarction (MI) within previous 72 hrs; >1 lesion/vessel; >2 vessels treated; lesion length > 27 mm; bifurcation; saphenous vein graft lesion; arterial bypass graft lesion; in-stent restenosis; unprotected left main lesion; lesion with thrombus; or lesion with total occlusion. Target vessel failure (TVF), the primary composite endpoint of the trial, was defined as cardiac death, target vessel-related MI, or target vessel revascularization. RESULTS: Among the 1,033 complex patients, 529 (51%) were treated with Resolute ZES and 504 (49%) with Xience V EES. Patient- and procedure-related characteristics were similar between DES groups. After 2-year follow-up, outcome was also similar between DES groups. TVF occurred in 12.1% of patients treated with Resolute ZES and 12.3% of patients treated with Xience V EES. In addition, DES groups did not differ significantly in cardiac death, MI, or target vessel revascularization-the individual components of TVF. CONCLUSION: Complex patients treated with Resolute ZES and Xience V EES showed similar safety and efficacy during 2-year follow-up. © 2014 Wiley Periodicals, Inc.
Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doença das Coronárias/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Doença das Coronárias/diagnóstico , Doença das Coronárias/mortalidade , Everolimo , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Países Baixos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Fatores de Risco , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND: Women are underrepresented in clinical research, and few data are available from randomized head-to-head comparisons of second-generation drug-eluting stents (DES) in female patients. Aim of this study was to assess safety and efficacy of two second-generation DES in women. In TWENTE-a prospective, randomized, comparative DES trial-"real-world" patients were stratified for gender before randomization for Resolute or Xience V stents. METHODS: Target vessel failure (TVF; cardiac death, target vessel-related myocardial infarction, and clinically indicated target vessel revascularization) after 1 year was the predefined endpoint. RESULTS: Among 1,391 patients, 382 (27.5%) women were randomized to Resolute (n = 192) and Xience V (n = 190). Baseline and procedural characteristics were similar for females in both study arms, except for smaller vessel and stent diameters in Resolute-treated lesions. After 1 year, TVF (8.9 vs. 8.4%; adjusted odds ratio [OR]: 0.95, 95% confidence interval [CI]: 0.41-2.20, P = 0.91) and a patient-oriented composite endpoint (13.0 vs. 12.1%, P = 0.79) did not differ significantly between women in both arms. Women were older than men (P < 0.01) and had more often diabetes mellitus (26.4 vs. 19.8%, P = 0.01) and hypertension (63.6 vs. 52.5%, P < 0.01), but there was no significant gender difference in TVF (adjusted OR: 1.18, 95% CI: 0.73-1.92, P = 0.50). CONCLUSIONS: This gender-stratified TWENTE trial analysis resulted in no significant difference in safety and efficacy outcomes between Resolute- and Xience V-treated females.
Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Fatores Etários , Idoso , Distribuição de Qui-Quadrado , Comorbidade , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Everolimo , Feminino , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Países Baixos , Razão de Chances , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Fatores Sexuais , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND: First- and second-generation drug-eluting stents (DES) differ in coating materials, which may influence the incidence of periprocedural myocardial infarction (PMI). OBJECTIVE: To compare the incidence of PMI between first- and second-generation DES, using the current Academic Research Consortium (ARC) definition of PMI. METHODS: We assessed 800 patients treated with first- (Taxus Liberté or Endeavor) or second-generation DES (Xience V or Resolute). Each DES group consisted of 200 consecutive patients, who were treated during the transition from first- to second-generation DES. Routine peri-interventional assessment of cardiac biomarkers was performed to compare the incidence of PMI between DES groups according to the updated definition by the ARC: 2x upper reference limit of creatine kinase (CK), confirmed by CK-MB elevation. RESULTS: In 800 patients, a total of 1,522 DES (363 Taxus; 385 Endeavor; 382 Xience V; 392 Resolute) were implanted to treat 1,232 lesions. Patient characteristics did not differ between groups. In patients receiving second-generation DES, more multivessel percutaneous coronary interventions were performed (P = 0.01). The overall incidence of PMI was 4.75%. Between first- and second-generation DES, there was no significant difference in PMI (5.5% vs. 4.0%; P = 0.29). In a multivariate analysis, only the total number of stents implanted (P < 0.001) and presentation with acute coronary syndrome (P = 0.02) were independent predictors of PMI. CONCLUSION: Using the revised ARC definition, we found no significant difference in PMI between first- and second-generation DES. Overall, PMI occurred in 4.75%, which is 58% lower than with use of the historical PMI definition.
Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/instrumentação , Idoso , Biomarcadores/sangue , Distribuição de Qui-Quadrado , Creatina Quinase Forma MB/sangue , Feminino , Humanos , Incidência , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/sangue , Países Baixos/epidemiologia , Razão de Chances , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
Importance: Stenting small-vessel lesions has an increased adverse cardiovascular event risk. Very thin-strut or ultrathin-strut drug-eluting stents might reduce this risk, but data are scarce. Objective: To assess the outcome of all-comer patients with small coronary vessel lesions treated with 3 dissimilar types of drug-eluting stents. Design: This is a prespecified substudy of the Comparison of Biodegradable Polymer and Durable Polymer Drug-eluting Stents in an All Comers Population (BIO-RESORT) trial, an investigator-initiated, randomized, patient-blinded comparative clinical drug-eluting stent trial. Patients treated with ultrathin-strut sirolimus-eluting stents, very thin-strut everolimus-eluting stents, or previous-generation thin-strut zotarolimus-eluting stents were enrolled from December 2012 to August 2015. This multicenter trial was conducted in 4 Dutch centers for cardiac intervention. Of all 3514 all-comer BIO-RESORT participants, 1506 patients with treatment in at least 1 small-vessel lesion (reference vessel <2.5 mm) were included. Data were analyzed between September 2018 and February 2019. Main Outcomes and Measures: Target lesion failure at 3-year follow-up, a composite of cardiac death, target vessel-related myocardial infarction, or target lesion revascularization, analyzed by Kaplan-Meier methods. Results: In 1452 of 1506 participants (96.4%) (1057 men [70.2%]; 449 women [29.8%]; mean [SD] age, 64.3 [10.4] years), follow-up was available. Target lesion failure occurred in 36 of 525 patients (7.0%) treated with sirolimus-eluting stents, 46 of 496 (9.5%) with everolimus-eluting stents, and 48 of 485 (10.0%) with zotarolimus-eluting stents (sirolimus-eluting vs zotarolimus-eluting hazard ratio [HR], 0.68; 95% CI, 0.44-1.05; P = .08; everolimus-eluting vs zotarolimus-eluting HR, 0.93; 95% CI, 0.62-1.39; P = .72). There was a difference in target lesion revascularizations between sirolimus-eluting and zotarolimus-eluting stents (2.1% vs 5.3%; HR, 0.40; 95% CI, 0.20-0.81; P = .009) that emerged after the first year of follow-up (1.0% vs 3.7%; P = .006); multivariate analysis showed that sirolimus-eluting stent implantation was independently associated with a lower target lesion revascularization rate at 3-year follow-up (adjusted HR, 0.42; 95% CI, 0.20-0.85; P = .02). In the everolimus-eluting stents, the revascularization rate was 4.0% (vs zotarolimus-eluting, HR, 0.74; 95% CI, 0.41-1.34; P = .31). There was no significant between-stent difference in cardiac death, target vessel myocardial infarction, or stent thrombosis. Conclusions and Relevance: Patients stented in small coronary vessels experienced fewer repeated revascularizations if treated with ultrathin-strut sirolimus-eluting stents vs previous generation thin strut zotarolimus-eluting stents. Further research is required to evaluate the potential effect of particularly thin stent struts. Trial Registration: ClinicalTrials.gov identifier: NCT01674803.
Assuntos
Reestenose Coronária/prevenção & controle , Stents Farmacológicos , Implantes Absorvíveis , Vasos Coronários , Everolimo/administração & dosagem , Feminino , Humanos , Imunossupressores/administração & dosagem , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/prevenção & controle , Intervenção Coronária Percutânea/instrumentação , Desenho de Prótese , Fatores de Risco , Sirolimo/administração & dosagem , Sirolimo/análogos & derivados , Resultado do TratamentoRESUMO
BACKGROUND: The prospective observational CHANGE DAPT study compared clopidogrel versus ticagrelor-based dual antiplatelet (DAPT) regimens in consecutive patients with acute coronary syndrome (ACS), treated with percutaneous coronary intervention (PCI) with contemporary drug-eluting stents (DES). During the ticagrelor period (TP, May 2014-August 2015) there were more major bleedings than during the clopidogrel period (CP, December 2012-April 2014). METHODS AND RESULTS: To evaluate whether the excess of major bleedings during TP may be limited to high bleeding risk (HBR) patients, we performed an explorative analysis of all 2062 CHANGE DAPT participants, of whom 547(26.5%) were classified as HBR (CP, nâ¯=â¯245; TP, nâ¯=â¯302). In HBR and non-HBR patients, we assessed the impact of CP versus TP on propensity score-adjusted rates of major bleeding and a pre-defined ischemic endpoint (composite of cardiac death, myocardial infarction, or stroke) at 1-year follow-up. Among HBR patients, the rate of major bleeding was significantly higher during TP (1.7% vs. 5.0%; HRadjusted 3.70 [95% CI 1.18-11.67], pâ¯=â¯0.03), while there was no significant difference in the ischemic endpoint (6.6% vs. 8.0%, HRadjusted 1.23 [95% CI 0.63-2.42], pâ¯=â¯0.54). In non-HBR patients, the rates of major bleeding (1.1% vs. 1.7%; HRadjusted 2.13 [95% CI 0.84-5.43], pâ¯=â¯0.11) and the ischemic endpoint (2.8% vs. 3.4%, HRadjusted 1.38 [95% CI 0.74-2.57], pâ¯=â¯0.32) were similar between both periods. CONCLUSIONS: Among consecutive ACS patients, the increased risk of major bleeding during ticagrelor-based DAPT was limited to HBR patients. In both HBR and non-HBR patients, ticagrelor-based DAPT did not reduce ischemic outcomes following treatment with contemporary DES implantation.
Assuntos
Síndrome Coronariana Aguda/terapia , Clopidogrel/efeitos adversos , Stents Farmacológicos/efeitos adversos , Hemorragia/induzido quimicamente , Inibidores da Agregação Plaquetária/efeitos adversos , Ticagrelor/efeitos adversos , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Stents Farmacológicos/tendências , Feminino , Seguimentos , Hemorragia/diagnóstico , Hemorragia/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/tendências , Estudos ProspectivosRESUMO
BACKGROUND: Percutaneous coronary intervention (PCI) in patients with previous coronary artery bypass grafting (CABG) is associated with adverse clinical events. Although newer generation drug-eluting stents showed favorable short-term safety profiles, there is a lack of long-term outcome data. We evaluated the impact of previous CABG on 5-year clinical outcomes of patients treated with PCI using newer-generation drug-eluting stents. METHODS AND RESULTS: In this patient-level pooled analysis of the prospective TWENTE (The Real-World Endeavor Resolute versus Xience V Drug-Eluting Stent Study in Twente) trial and nonenrolled TWENTE registry, we assessed a consecutive series of patients who underwent PCI with newer-generation drug-eluting stents for non-ST-segment-elevation acute coronary syndromes or stable angina. Of all 1709 patients, 202 (11.8%) had a history of CABG. Patients with previous CABG had significantly higher 5-year rates of cardiac death (10.4% versus 4.3%; P<0.001) and target vessel revascularization (25.0% versus 8.1%; P<0.001). These differences remained statistically significant after adjustment for differences in baseline characteristics. Landmark analysis revealed that from 1- to 5-year follow-up, the rates of cardiac death (8.1% versus 3.2%; P<0.001) and target vessel revascularization (17.1% versus 5.9%; P<0.001) were significantly higher in patients with previous CABG. Among patients with a history of CABG, PCI of an obstructed vein graft was associated with a higher rate of 5-year target vessel revascularization (P=0.003). CONCLUSIONS: At 5-year follow-up after PCI with newer-generation drug-eluting stents, the risk of cardiac death and target vessel revascularization was significantly higher in patients with previous CABG. The target vessel revascularization rate was highest in patients who underwent PCI of obstructed vein grafts.
Assuntos
Ponte de Artéria Coronária , Doença das Coronárias/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Idoso , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/mortalidade , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/mortalidade , Doença das Coronárias/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Sistema de Registros , Retratamento , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
OBJECTIVES: This study sought to assess the prevalence and clinical impact of silent diabetes and pre-diabetes in "nondiabetic" percutaneous coronary intervention (PCI) all-comers. BACKGROUND: Patients with undetected and thus untreated (silent) diabetes may have higher event risks after PCI with contemporary drug-eluting stents (DES). METHODS: The BIO-RESORT Silent Diabetes study, performed at Thoraxcentrum Twente, is a substudy of the randomized multicenter BIO-RESORT (BIOdegradable Polymer and DuRable Polymer Drug-eluting Stents in an All COmeRs PopulaTion) trial (NCT01674803). Patients underwent oral glucose tolerance testing (OGTT), and assessment of glycosylated hemoglobin with fasting plasma glucose. Primary endpoint was a composite of cardiac death, target vessel-related myocardial infarction, or target vessel revascularization at 1 year. RESULTS: Of the 988 participants, OGTT detected silent diabetes in 68 (6.9%), pre-diabetes in 133 (13.3%), and normal glucose metabolism in 788 (79.8%). Patients with silent diabetes had higher primary endpoint rates (13.2% vs. 7.6% vs. 4.8%; p < 0.001; silent diabetes vs. normal: hazard ratio: 4.2; 95% confidence interval: 1.9 to 9.2). Differences were driven by myocardial infarction (p < 0.001) which occurred mostly <48 h. Based on glycosylated hemoglobin and fasting plasma glucose, silent diabetes was found in 33 (3.3%) patients, pre-diabetes in 217 (22.0%) patients, and normal glucose metabolism in 738 (74.7%) patients; primary endpoint rates were similar to OGTT-based analyses (12.1% vs. 5.5% vs. 3.1%; p = 0.01). Multivariate analyses demonstrated that abnormal glucose metabolism by either diagnostic approach, present in 330 (33.4%) patients, independently predicted adverse event risk (hazard ratio: 2.2; 95% confidence interval: 1.2 to 4.2). CONCLUSIONS: Abnormal glucose metabolism was detected in 1 of 3 "nondiabetic" PCI patients and was independently associated with up to 4-fold higher event risks. Future intervention trials should determine whether meaningful benefits accrue from routine glycemia testing in such patients.
Assuntos
Doença da Artéria Coronariana/cirurgia , Diabetes Mellitus/epidemiologia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Idoso , Doenças Assintomáticas , Biomarcadores/sangue , Glicemia/metabolismo , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Diabetes Mellitus/sangue , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidade , Feminino , Teste de Tolerância a Glucose , Hemoglobinas Glicadas/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estado Pré-Diabético/sangue , Estado Pré-Diabético/diagnóstico , Estado Pré-Diabético/epidemiologia , Prevalência , Estudos Prospectivos , Desenho de Prótese , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
OBJECTIVES: The study sought to evaluate for the first time the 5-year outcomes after treating an all-comers population with newer-generation cobalt chromium-based Resolute Integrity zotarolimus-eluting stents (ZES) (Medtronic, Santa Rosa, California) versus platinum chromium-based PROMUS Element everolimus eluting stents (EES) (Boston Scientific, Natick, Massachusetts). BACKGROUND: The DUTCH PEERS (TWENTE II) (DUrable polymer-based sTent CHallenge of Promus ElemEnt versus ReSolute integrity: TWENTE II) trial is a randomized, multicenter, single-blinded, investigator-initiated all-comers trial that found at its main analysis similar 1-year safety and efficacy for both drug-eluting stents. It is the first randomized trial ever to investigate the Resolute Integrity ZES and the first trial to compare both devices. METHODS: In total, 1,811 patients were 1:1 randomized to ZES versus EES. We performed a pre-specified assessment of the 5-year clinical outcomes in terms of safety and efficacy. The main endpoint target vessel failure (TVF) is a composite of cardiac death, target vessel-related myocardial infarction, or target vessel revascularization. Secondary endpoints included the individual components of TVF, and stent thrombosis. The study was independently monitored, and adverse clinical events were independently adjudicated. RESULTS: Five-year clinical follow-up data was available in 1,798 (99.3%) patients. The ZES and EES groups showed favorable outcomes, with similar 5-year incidence of TVF (13.2% vs. 14.2%; plog-rank = 0.62) and its individual components: cardiac death (4.5% vs. 4.9%; plog-rank = 0.69), target vessel-related myocardial infarction (3.1% vs. 2.6%; plog-rank = 0.47), and target vessel revascularization (7.6% vs. 8.6%; plog-rank = 0.46). The 5-year incidence of definite or probable stent thrombosis was similar (1.5% vs. 1.3%; plog-rank = 0.83). CONCLUSIONS: At 5-year follow-up, the Resolute Integrity ZES and PROMUS Element EES showed similar and sustained results in terms of safety and efficacy for treating a broad population of all-comers.
Assuntos
Síndrome Coronariana Aguda/cirurgia , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Everolimo/administração & dosagem , Infarto do Miocárdio/cirurgia , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/mortalidade , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/etiologia , Trombose Coronária/etiologia , Everolimo/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/mortalidade , Países Baixos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Fatores de Risco , Método Simples-Cego , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do TratamentoRESUMO
Importance: Long-term follow-up after a clinical trial of 2 often-used, newer-generation drug-eluting stents (DESs) in a broad patient population is of interest. Comprehensive long-term outcome of eligible nonenrolled patients has never been reported. Objective: To assess 5-year safety and efficacy of 2 newer-generation DESs in randomized participants with non-ST-elevation acute coronary syndromes or stable angina and to evaluate long-term outcomes of nonenrolled eligible patients treated with the same DESs. Design, Setting, and Participants: The TWENTE (Real-World Endeavor Resolute vs Xience V Drug-Eluting Stent Study in Twente) trial is an investigator-initiated, patient-blinded, randomized, comparative DES trial that enrolled patients from June 18, 2008, to August 26, 2010. Most patients had non-ST-elevation acute coronary syndromes and complex lesions. Of all 1709 eligible patients, 1391 (81.4%) were treated in the TWENTE trial with zotarolimus-eluting (ZES, n = 697) or everolimus-eluting (EES, n = 694) cobalt-chromium stents. The remaining 318 eligible patients (18.6%) were not enrolled but underwent nonrandomized treatment with the same DESs. Data were analyzed from August 26, 2015, to October 11, 2016. Event rates (percentages) were derived from log-rank analysis and may differ from straightforward calculation (nominator/denominator). The 5-year follow-up of the TWENTE participants was prespecified in the trial protocol; that of the nonenrolled participants was ad hoc. Main Outcomes and Measures: Target vessel failure (TVF), a composite of cardiac death, target vessel-related myocardial infarction, or target vessel revascularization. Results: Of 1709 eligible participants, 1233 (72.1%) were men, 476 (27.9%) were women, and mean (SD) age was 64.6 (10.6) years. Among the 1370 of 1391 TWENTE trial participants (98.5% follow-up), TVF was similar between those in the ZES (16.1%) and EES (18.1%) groups (P = .36). Stent thrombosis rates were low: definite (7 of 697 [1.0%] vs 4 of 694 [0.6%]; P = .37) and occurred after more than 1 year in 3 (0.4%) with ZES vs 4 (0.6%) with EES (P = .69). The 318 nonenrolled eligible patients (308 patients [96.9%] of whom were followed up) were older and had more advanced disease than trial participants. Their TVF rate was higher than that of trial participants (71 of 318 [23.3%] vs 233 of 1391 [17.1%]; P = .02), which partly reflects a difference in cardiac mortality (23 of 318 [7.7%] vs 60 of 1391 [4.5%]; P = .03). Similar 5-year rates were found for myocardial infarction (91 of 1391 [6.7%] vs 22 of 318 [7.2%]; P = .80) and target vessel revascularization (129 of 1391 [9.7%] vs 34 of 318 [11.4%]; P = .36) between trial participants and nonenrolled eligible patients. In all eligible patients (ie, trial participants plus nonenrolled eligible patients), the TVF rate was only slightly higher than in trial participants only (18.3% vs 17.1%). Conclusions and Relevance: Long-term outcome data from nonenrolled eligible patients support the validity of the TWENTE trial findings and present, with the trial, a strong case for the long-term safety and efficacy of the newer-generation DESs used. Trial Registration: clinicaltrials.gov Identifier: NCT01066650.
Assuntos
Stents Farmacológicos , Everolimo/farmacologia , Infarto do Miocárdio/cirurgia , Seleção de Pacientes , Intervenção Coronária Percutânea/métodos , Complicações Pós-Operatórias/epidemiologia , Sirolimo/análogos & derivados , Angiografia Coronária , Feminino , Seguimentos , Humanos , Imunossupressores/farmacologia , Incidência , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Desenho de Prótese , Sirolimo/farmacologia , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologiaRESUMO
BACKGROUND: Data on medium-term outcome of patients with acute coronary syndrome (ACS), treated with newer-generation durable polymer drug-eluting stents (DES) in severely calcified coronary lesions, are scarce. We aimed to assess the impact of severe coronary lesion calcification on clinical outcome of patients with ACS, treated with newer-generation DES. METHODS: The TWENTE and DUTCH PEERS randomized trials comprise 1779 ACS patients, who were categorized into patients with versus without severe target lesion calcification. We performed a patient-level pooled analysis to assess 2-year outcome, including target vessel failure (TVF), a composite of cardiac death, target vessel-related myocardial infarction (MI), or target vessel revascularization (TVR). RESULTS: Patients with severe target lesion calcification (n=340, 19.1%) were older (66.8±10.6 years vs. 62.8±11.5 years, p<0.001) and had more often diabetes (22.1% vs. 16.8%, p=0.02) and hypercholesterolemia (51.5% vs. 42.9%, p=0.005) than other patients (n=1439, 79.9%). In addition they showed a higher TVF rate (12.4% vs.7.0%, p=0.001), mainly related to a difference in TVR (6.8% vs. 3.3%, p=0.003). There was a borderline significant between-group difference in cardiac death (3.6% vs. 1.8%, p=0.05), but not in target vessel MI (3.8% vs.2.6%, p=0.23) and definite stent thrombosis (0.9% vs. 0.6%, p=0.71). Multivariate analysis demonstrated that severe lesion calcification was an independent risk factor of TVF (adjusted HR; 1.58, 95% CI: 1.23-2.03; p<0.001). CONCLUSIONS: In patients with ACS, treatment of severely calcified lesions with newer-generation DES was associated with an overall higher clinical event risk - related in particular to a higher TVR rate, while the risk of MI was low.
Assuntos
Síndrome Coronariana Aguda/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea , Índice de Gravidade de Doença , Calcificação Vascular/terapia , Síndrome Coronariana Aguda/mortalidade , Fatores Etários , Idoso , Diabetes Mellitus/epidemiologia , Feminino , Humanos , Hipercolesterolemia/epidemiologia , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/epidemiologia , Intervenção Coronária Percutânea/efeitos adversos , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Trombose/epidemiologiaRESUMO
AIMS: Acute coronary syndrome (ACS) guidelines have been changed, favouring more potent antiplatelet drugs. We aimed to evaluate the safety and efficacy of a ticagrelor- instead of a clopidogrel-based primary dual antiplatelet (DAPT) regimen in ACS patients treated with newer-generation drug-eluting stents (DES). METHODS AND RESULTS: CHANGE DAPT (clinicaltrials.gov: NCT03197298) assessed 2,062 consecutive real-world ACS patients, treated by percutaneous coronary intervention (PCI), the primary composite endpoint being net adverse clinical and cerebral events (NACCE: all-cause death, any myocardial infarction, stroke or major bleeding). In the clopidogrel (CP; December 2012-April 2014) and ticagrelor periods (TP; May 2014-August 2015), 1,009 and 1,053 patients were treated, respectively. TP patients were somewhat older, underwent fewer transfemoral procedures, and received fewer glycoprotein IIb/IIIa inhibitors. In the TP, the one-year NACCE rate was higher (5.1% vs. 7.8%; HR 1.53 [95% CI: 1.08-2.17]; p=0.02). Assessment of non-inferiority (pre-specified margin: 2.7%) was inconclusive (risk difference: 2.64 [95% CI: 0.52-4.77]; pnon-inferiority=0.48). TP patients had more major bleeding (1.2% vs. 2.7%; p=0.02) while there was no benefit in ischaemic endpoints. Propensity score-adjusted multivariate analysis confirmed higher NACCE (adj. HR 1.75 [95% CI: 1.20-2.55]; p=0.003) and major bleeding risks during TP (adj. HR 2.75 [95% CI: 1.34-5.61]; p=0.01). CONCLUSIONS: In this observational study, the guideline-recommended ticagrelor-based primary DAPT regimen was associated with an increased event risk in consecutive ACS patients treated with newer-generation DES.
Assuntos
Síndrome Coronariana Aguda/terapia , Adenosina/análogos & derivados , Stents Farmacológicos/efeitos adversos , Inibidores da Agregação Plaquetária/uso terapêutico , Ticlopidina/análogos & derivados , Adenosina/efeitos adversos , Adenosina/uso terapêutico , Idoso , Idoso de 80 Anos ou mais , Aspirina/uso terapêutico , Clopidogrel , Doença da Artéria Coronariana/terapia , Quimioterapia Combinada/métodos , Feminino , Hemorragia/induzido quimicamente , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/métodos , Ticagrelor , Ticlopidina/efeitos adversos , Ticlopidina/uso terapêuticoRESUMO
AIMS: To keep patients in long-term clinical follow-up programmes after percutaneous coronary intervention (PCI), knowledge of the patient-preferred mode for follow-up assessment is crucial. We systematically assessed patient preference, and explored potential relationships with age and gender. METHODS AND RESULTS: In the prospective, observational PAPAYA study (ClinicalTrials.gov: NCT02189070), 2,566 patients, treated by PCI between June 2008 and May 2012, were invited to participate in a postal survey on the patient-preferred mode (postal questionnaire, telephone or e-mail consultation) and frequency of follow-up assessment. A total of 1,797 (70.0%) patients responded. The vast majority preferred completing postal questionnaires (1,248 [69.9%]) as compared to telephone (240 [13.4%]) or e-mail-based approaches (227 [12.7%]) (p<0.001). With increasing age, there was a gradual decline in preference for e-mail (p<0.001); the youngest patients (≤60 years) preferred e-mail-based follow-up more often than the oldest (21.1% vs. 3.1%). Nevertheless, 79.9% of the youngest preferred to be approached in ways other than by e-mail. Women more often preferred approaches other than e-mail (94.1% vs. 87.3%, p<0.001). CONCLUSIONS: Patients showed a distinct preference for completing postal questionnaires rather than being approached by telephone or e-mail. Younger patients accepted e-mail-based follow-up more often, but the majority of the youngest patients still preferred approaches other than by e-mail.
Assuntos
Doença das Coronárias/terapia , Preferência do Paciente/estatística & dados numéricos , Intervenção Coronária Percutânea , Correio Eletrônico , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Fatores Sexuais , Inquéritos e Questionários , TelefoneRESUMO
AIMS: The SYNTAX score is a tool to quantify the complexity of coronary artery disease. We investigated the relation between the SYNTAX score and the occurrence of a periprocedural myocardial infarction (PMI) according to the historical definition of the World Health Organization (WHO) and the recently updated universal definition of MI. METHODS AND RESULTS: The SYNTAX score was calculated in 1,243 patients enrolled in TWENTE, a randomised trial which assessed second-generation drug-eluting stents. PMI was defined by the WHO definition and the third universal definition of MI. Patients were divided into tertiles of the SYNTAX score: ≤7 (n=430); >7 and <15 (n=390); ≥15 (n=423). PMI according to the WHO definition occurred more frequently in patients in the highest SYNTAX score tertile (7.3% vs. 3.1% vs. 1.6%, p<0.001) compared to the mid and lowest tertile. Similar findings were seen for universal PMI (9.9% vs. 7.7% vs. 3.7%, p<0.01). After multivariate analysis, SYNTAX score was a significant independent correlate of PMI for both definitions: the highest SYNTAX score tertile had an almost five times higher risk for WHO PMI, and a three times higher risk for universal PMI. CONCLUSIONS: In a broad patient population treated with second-generation DES, the SYNTAX score was able to stratify the risk of PMI.